Enercast — at the moment it matters
Home  /  Archive  /  September 2026

Pipeline Notices — September 2026

248 notices recorded this month

248 notices
Columbia Gulf Transmission (CGT)

Golden Meadow & Centerville Compressor Station Maintenance (EL300SEG), September 15-18, 2026

SEV 4/5
Maintenance 0.075 Bcf/d 4 Days

CGT has notified customers of planned maintenance at both Golden Meadow and Centerville Compressor Stations from September 15-18, 2026, reducing backhaul capacity on EL300SEG to 350,000-500,000 Dth/day against a design capacity of 575,000 Dth/day -- a restriction of up to 225,000 Dth/day (0.225 Bcf/d). CGT explicitly warns that curtailments to Interruptible, Secondary Firm, and Primary Firm services are anticipated, a significant escalation beyond typical interruptible-only curtailment language. Live capacity data confirms EL300SEG is already at 100% utilization (0.575 Bcf/d scheduled against 0.575 Bcf/d operating capacity) as of the September 8 timely cycle, corroborating the tightness described in the notice.

CGT maintenance on EL300SEG cuts backhaul capacity by up to 0.225 Bcf/d (midpoint ~0.113 Bcf/d restriction at the 500k Dth floor) for four days starting September 15, with primary firm curtailments explicitly at risk; Columbia Gulf mainline basis, which has traded at an average of -0.247 vs Henry Hub over the five trading days ended September 4 (most recently -0.215 on September 4), is likely to widen further as southbound backhaul tightens and Transco Zone 4 Southeast basis firms in sympathy.
Reroute: Moderate: Texas Eastern (TETCO) and Trunkline (TGC) serve overlapping Gulf Coast northbound corridors and could absorb some displaced volumes, but the explicit primary firm curtailment risk on a Critical notice suggests CGT does not anticipate sufficient system-level flexibility to avoid firm impacts.
View original notice text
TSP Name Columbia Gulf Transmission, LLC
TSP 007854581
Notice Type Description: Maintenance

Notice Stat Desc: Initiate

Prior Notice: 

Critical: Y

Reqrd Rsp Desc: No Response Required
Post

Notice Effective

Notice End



Response
Post Date: 09/08/26

09/08/26

10/08/26
Subject: Subject: Golden Meadow & Centerville Compressor Station Maintenance (EL300SEG), September 15-18, 2026
Author: Author: Dillon Schoolcraft
Notice Text
Columbia Gulf Transmission LLC (CGT) reminds customers of upcoming maintenance at both Golden Meadow and Centerville Compressor Stations, beginning on Tuesday, September 15, 2026, through Friday, September 18, 2026. As a result, the Backhaul capacity through EL300SEG will be reduced to a level between 350,000 and 500,000 Dth effective Timely Cycle for Gas Day Tuesday, September 15, 2026. 

CGT anticipates this restriction may result in curtailments to Interruptible, Secondary Firm, and Primary Firm services. Please see the details provided below for more information.

EL300SEG

·       Estimated Capacity Setting: 350,000 - 500,000 Dth 

·       Design Capacity: 575,000 Dth

·       Posted Percentage: 61-87%

Due to the potential impact to firm service, CGT encourages customers to monitor the scheduled volumes on the Operationally Available Capacity screen on Informational Postings, as nominations can fluctuate based on market conditions. 

Reservation Charge Credits (RCCs) will be determined per the process set forth in the General Terms and Conditions, Section 40 of CGT’s FERC Gas Tariff (Tariff). By means of this notice, CGT is establishing the 7-day Average Usage Quantity to be the period of September 1-7, 2026, pursuant to the provisions in the Tariff. 

Please contact your Customer Services Representative with any questions.
Rockies Express

[FORCE MAJEURE] REX CHANDLERSVILLE COMPRESSOR STATION (SEG 380) FORCE MAJEURE

SEV 4/5
Force Majeure 2.772 Bcf/d

REX declared force majeure at Chandlersville Compressor Station (Segment 380) on September 7, 2026, limiting eastbound-to-westbound capacity to 2,835 MDth/d (2.835 Bcf/d) for the ID3 cycle on Gas Day September 7, and 2,772 MDth/d (2.772 Bcf/d) from the Evening Cycle of Gas Day September 8 until further notice. Primary firm, secondary firm, and AOR/ITS service are all explicitly at risk of not being scheduled, indicating curtailments across all service classes. No restoration timeline has been provided.

REX force majeure at Chandlersville CS (Seg 380) limits east-to-west capacity to 2.772 Bcf/d until further notice with all firm service classes at risk; REX Zone 3 basis was -0.250 vs Henry Hub as of 2026-09-04 and is subject to further pressure as westbound Appalachian-origin receipts back up at the Lebanon Hub while downstream Midwest and Ohio Valley markets tighten -- expect bullish Zone 3 and Lebanon Hub basis and bearish pressure on any westbound receipt points unable to schedule.
Reroute: Moderate: REX Zone 3 westbound Appalachian volumes have partial alternatives via Rover Pipeline, TETCO M2, and TCO for Midwest and Ohio Valley markets, but these pipes serve different downstream points and cannot fully replace REX westbound throughput at this scale; no single alternative approaches 2.772 Bcf/d of replacement capacity on short notice.
View original notice text
Pipeline: Rockies Express
Notice ID: 14070
Notice Type: Critical notice
Sub-Type: FORCE MAJEURE
Subject: REX CHANDLERSVILLE COMPRESSOR STATION (SEG 380) FORCE MAJEURE
Posted: 9/7/2026 3:53:07 PM
Effective: 9/7/2026 3:53:07 PM
End Date: 12/31/9000

REX CHANDLERSVILLE COMPRESSOR STATION (SEG 380) FORCE MAJEURE
On Monday, September 7, 2026, Rockies Express Pipeline LLC (“REX”) experienced a Force Majeure
event (as defined in Section 21 of the GT&C of the Tariff) at its Chandlersville Compressor Station
(Segment 380).
Operating capacity will be limited to the following capacities on the following Days and Cycles in the East
to West direction:
• ID3 Cycle, Gas Day Monday, September 7, 2026: 2,835 MDth/d
• Evening Cycle, Gas Day Tuesday, September 8, 2026 and until further notice: 2,772 MDth/d
Primary and secondary firm quantities, as well as AOR/ITS are at risk of not being scheduled.
REX is continuing to monitor progress across the system and will post updates as more information
becomes available.
For questions, please call your Account Director or Scheduling Hotline at 303-763-2906.
Nautilus Pipeline Company

09/03/2026- Nautilus Force Majeure - Unplanned Outage at Enterprise Neptune plant - Update

SEV 4/5
Force Majeure

Nautilus Pipeline has declared force majeure following an unplanned outage at the Enterprise Neptune offshore processing plant, effective September 3, 2026. The plant continues troubleshooting with no estimated restart timeline, and Nautilus is reducing all scheduled quantities to EPSQ (Elapsed Prorata Scheduled Quantity) for the Intraday 3 cycle on the September 3 gas day. No restoration ETA has been provided, and the notice end date extends to December 2, 2026, suggesting a potentially prolonged constraint.

Nautilus force majeure with no restart ETA removes offshore GoM supply volumes from the onshore market indefinitely; bullish for Henry Hub spot and Gulf Coast basis with duration risk extending into Q4 2026.
Reroute: None: Nautilus is an offshore gathering pipeline serving the Enterprise Neptune plant directly; there is no alternative routing for production shut in at this offshore facility.
View original notice text
TSP Name: Nautilus Pipeline Company, L.L.C.
Subject: Nautilus Force Majeure - Unplanned Outage at Enterprise Neptune plant - Update
Notice Type: Force Majeure
Critical Notice Description: Critical notice
Notice Status Description: Initiate
Notice Effective Date: 09/03/2026
Notice End Date: 12/02/2026
Posting Date: 09/03/2026
Notice Identifier: 182546
Required Response Indicator Description: No response required

Notice Text:
Nautilus has been informed that the Enterprise Neptune plant continues troubleshooting the issue with no ETA for a restart. Nautilus will be reducing all scheduled quantities to EPSQ for the Intraday 3 cycle for the September 3, 2026 Gas Day.
Updates will be posted as they become available.
This event constitutes a Force Majeure, pursuant to section 25 of the General Terms and Conditions of Nautilus' FERC Gas Tariff.
For questions concerning this notice, please contact your Enbridge Offshore account rep at 713-627-6204.
CPL

Anticipated Cove Point Restrictions Update

SEV 4/5
Capacity Constraint Until Further Notice

CPL has posted a Critical PPO (Planned Planned Outage) notice effective 2026-09-19 14:00 flagging anticipated restrictions at the Cove Point LNG export terminal in Maryland. No specific capacity volume or restoration date is stated in the notice text. As of the 2026-09-03 gas day (one day lag), COVE POINT PLANT delivery was running at 94.5% utilization (0.869 Bcf/d scheduled against 0.920 Bcf/d operating capacity), leaving only 0.051 Bcf/d of headroom -- confirming the system is already running tight ahead of the restriction.

Cove Point LNG feedgas restriction beginning 2026-09-19 removes demand from the Appalachian supply stack, bearish for Appalachian basin basis -- Eastern Gas South regional proxy was most recently -1.265 vs Henry Hub (2026-09-03) and has averaged -1.130 over the prior five trading days; further softening in that regional read and the export arb is likely if the restriction proves material, with no offsetting bullish signal for Henry Hub.
Reroute: None: Cove Point LNG is the sole LNG export terminal served by CPL; feedgas volumes that cannot be nominated to the plant have no alternative export outlet and will back into the Appalachian pipeline network.
View original notice text
Pipeline: CPL
Notice ID: 1011353
Subject: Anticipated Cove Point Restrictions Update
Notice Type: Notices
Posted: 2026-09-04T17:47:54.408
Effective: 2026-09-19T14:00:00
naesbNoticeTypeDescription: Capacity Constraint
subcategory: Critical
tspDefinedNoticeTypeDescription: PPO
Columbia Gulf Transmission (CGT)

UPDATE: Hampshire Compressor Station Maintenance

SEV 4/5
Maintenance 0.391 Bcf/d Until Further Notice 77 Days

CGT has updated its Hampshire Compressor Station maintenance notice, revising the lower bound of the backhaul capacity restriction downward to 2,150,000 Dth/d (from the prior 2,200,000 Dth/d floor), against a design capacity of 2,540,656 Dth/d -- a reduction of up to 0.391 Bcf/d versus design. The maintenance window remains September 9 through November 25, 2026 (77 days). Critically, the prior posting explicitly warned of potential curtailments to Interruptible, Secondary Firm, and Primary Firm services, an escalation trigger that elevates severity; the updated notice widens the capacity reduction range modestly on the downside and removes the explicit firm-service curtailment language, but the prior notice established that risk and it has not been formally withdrawn. Live capacity data for HampSEG (TD4 cycle, timely) shows 2.15 Bcf/d scheduled against 2.54 Bcf/d operating capacity at 84.8% utilization today, consistent with pre-event conditions ahead of the September 9 effective date.

CGT Hampshire maintenance removes up to 0.391 Bcf/d of backhaul capacity on HampSEG from September 9 through November 25, representing roughly 15% of the segment's design capacity; with Columbia Gulf mainline basis most recently at -0.215 vs Henry Hub (2026-09-03) against a 5-day trailing average of -0.254, expect this basis to tighten (move less negative or flip positive) as northbound backhaul tightens through Kentucky and into TETCO/Adair Co. interconnects, which is already showing only 3.6% headroom at 0.200 Bcf/d scheduled.
Reroute: Moderate: Texas Eastern (TETCO) and Trunkline (TGC) serve overlapping Gulf Coast northbound corridors and provide partial reroute options, but the multi-month duration and the prior notice's warning of firm service curtailments suggest the constraint exceeds what parallel capacity can fully absorb without basis widening.
View original notice text
TSP Name Columbia Gulf Transmission, LLC
TSP 007854581
Notice Type Description: Maintenance

Notice Stat Desc: Supersede

Prior Notice: 26210020

Critical: Y

Reqrd Rsp Desc: No Response Required
Post

Notice Effective

Notice End



Response
Post Date: 09/04/26

09/04/26

10/04/26
Subject: Subject: UPDATE: Hampshire Compressor Station Maintenance
Author: Author: Tyler King
Notice Text
Columbia Gulf Transmission, LLC (CGT) notifies customers that based on updated logistics involving the upcoming maintenance at Hampshire Compressor Station, the backhaul capacity will be reduced to a level between 2,150,000 Dth and 2,350,000 Dth effective Timely Cycle for Gas Day Wednesday, September 9, 2026. 

CGT encourages customers to monitor the Daily Capacity Posting each day of the maintenance for the specific capacity setting through HampSEG. 

HampSEG

·       Estimated Capacity Setting: 2,150,000 - 2,350,000 Dth

·       Design Capacity: 2,540,656

·       Posted Percentage: 85-92%





Reservation Charge Credits (RCCs) will be determined per the process set forth in the General Terms and Conditions, Section 40 of CGT’s FERC Gas Tariff (Tariff). 

Please contact your Customer Services Representative with any questions.

  

***Previous Posting***





Columbia Gulf Transmission LLC (CGT) notifies customers of upcoming maintenance at Hampshire Compressor Station scheduled for Wednesday, September 9, 2026, through Wednesday, November 25, 2026. As a result, the backhaul capacity through HampSEG will be reduced to a level between 2,200,000 and 2,350,000 Dth effective Timely Cycle for Gas Day Wednesday, September 9, 2026.

CGT anticipates this restriction may result in curtailments to Interruptible, Secondary Firm, and Primary Firm services. Please see the details provided below for more information.

 HampSEG

·       Estimated Capacity Setting: 2,200,000 - 2,350,000 Dth

·       Design Capacity: 2,540,656

·       Posted Percentage: 87-92%

Due to the potential impact to firm service, CGT encourages customers to monitor the scheduled volumes on the Operationally Available Capacity screen on Informational Postings, as nominations can fluctuate based on market conditions.

Reservation Charge Credits (RCCs) will be determined per the process set forth in the General Terms and Conditions, Section 40 of CGT’s FERC Gas Tariff (Tariff). By means of this notice, CGT is establishing the 7-day Average Usage Quantity to be the period of August 20-26, 2026, pursuant to the provisions in the Tariff.

Please contact your Customer Services Representative with any questions.
El Paso Natural Gas (EPNG)

[FORCE MAJEURE] Force Majeure – Line No. 1103

SEV 4/5
Force Majeure 0.159 Bcf/d 1 Days

EPNG has declared force majeure on Line No. 1103 between Pecos River and Guadalupe in Culberson County, Texas, following discovery of safety and integrity anomalies downstream of Pecos River Compressor Station. Effective September 5, 2026 Timely Cycle, operational capacity through the PECOS constraint is reduced by 0.159 Bcf/d and through the GUADLUP constraint by 0.136 Bcf/d, with a pressure restriction and isolation required to facilitate repairs. The stated end date is September 5, 2026 at 9:00 AM, making this a short-duration but formally declared force majeure event on a key Permian outbound segment.

EPNG force majeure on Line 1103 removes up to 0.159 Bcf/d of Permian outbound takeaway capacity; expect bearish pressure at Waha as basin gas backs up, with mild bullish pressure at SoCal Border and Arizona delivery points -- though the one-day duration limits sustained market impact.
Reroute: Moderate: Transwestern Pipeline (TW) serves overlapping SoCal border and Arizona markets and is the primary alternative to EPNG for westbound Permian volumes; however, available TW spare capacity on any given day is uncertain and partial reroute is the realistic outcome for the affected 0.159 Bcf/d.
View original notice text
Pipeline: El Paso Natural Gas (EPNG)
Notice Type: FORCE MAJEURE
Subject: Force Majeure – Line No. 1103
Posted: 09/04/2026 10:49:35AM
Effective: 09/04/2026 10:49:35AM
End Date: 09/05/2026 9:00:00AM

TSP/TSP Name:  8001703-EL PASO NATURAL GAS CO. L.L.C. Critical: Y
Notice Type Desc (1):  FORCE MAJEURE Notice Type Desc (2):  FORCE MAJEURE
Notice Eff Date/Time:  09/04/2026 10:49:35AM Notice End Date/Time:  09/05/2026 9:00:00am
Post Date/Time:  9/4/2026 10:49:35 AM Notice ID: 629537
Reqrd Rsp:  5 Rsp Date/Time: 
Notice Stat Desc:  INITIATE Prior Notice: 
Subject:  Force Majeure – Line No. 1103
Notice Text:
Force Majeure – Line No. 1103 – Pecos River to Guadalupe
 
El Paso Natural Gas Company, L.L.C. (EPNG) has identified anomalies on Line No. 1103 downstream of its Pecos River Compressor Station in Culberson County, Texas, that affect the safety and integrity of the line and require immediate attention. Accordingly, Line No. 1103 between Pecos River and Guadalupe will be subject to a pressure restriction and isolation to facilitate the necessary repairs.
As a result, the operational capacity through the PECOS constraint will be reduced by 158,838 dekatherms per day (Dth/d) effective September 5, 2026, Timely Cycle (Cycle 1).
 
The operational capacity through the GUADLUP constraint will be reduced by 136,461 dekatherms per day (Dth/d) effective September 5, 2026, Timely Cycle (Cycle 1).
EPNG will be posting an updated maintenance notice to reflect the total impact through the PECOS and GUADLUP constraints.
EPNG will provide updates as more information becomes available.
This incident constitutes an event of Force Majeure under Section 11.3 of the General Terms and Conditions of EPNG's FERC Gas Tariff.
For scheduling questions, please call your scheduling representative at (800) 238-3764.
For operational and capacity information, please call Russ Pyeatt at (719) 520-3729, Dan English at (719) 520-4722, Morgan McCasland at (719) 520-4339 or John Althoff at (719) 667-7750.
For media inquiries, please contact media relations at media_relations@kindermorgan.com.
Tallgrass Energy

[Tallgrass Interstate Gas Transmission (TIGT)] [OPERATIONAL ALERT] SEGMENT 520 OPERATIONAL ISSUE

SEV 4/5
Capacity Constraint

TIGT has declared an operational alert on Segment 520 from Otis to Stockton due to an ongoing pipeline integrity issue requiring section replacement, effective Gas Day August 25, 2026 (ID1 Cycle), and the outage is expected to last longer than originally anticipated with no restoration date given. Primary firm, secondary firm, and interruptible/as-available service quantities are all at risk of not being scheduled on this segment. TIGT is working with affected customers on alternative connections but cannot guarantee full scheduling of nominations.

TIGT Segment 520 (Otis to Stockton) is offline indefinitely with firm service at risk; Cheyenne Hub regional basis has averaged -0.442 vs Henry Hub over the five trading days ended 2026-09-02 (most recently -0.410 on 2026-09-02) and further bearish pressure on Rockies/Midcontinent regional basis is likely until a restoration timeline is established -- no capacity volume is quantified in the notice.
Reroute: Limited: TIGT serves the Rockies-to-Midcontinent corridor, and while PEPL and Southern Star serve overlapping Midcontinent markets, the integrity-driven segment outage with no restoration timeline makes full volume displacement uncertain; affected customers are being worked individually for alternative connections per the notice.
View original notice text
Pipeline: Tallgrass Interstate Gas Transmission (TIGT)
Notice ID: 14067
Notice Type: Critical notice
Sub-Type: OPERATIONAL ALERT
Subject: SEGMENT 520 OPERATIONAL ISSUE
Posted: 9/3/2026 3:23:47 PM
Effective: 9/3/2026 3:23:47 PM
End Date: 12/31/9000

SEGMENT 520 OPERATIONAL ISSUE
TIGT is posting notice of an Operational Issue after identifying an ongoing integrity issue on a section of
pipeline being replaced, as communicated to affected customers.
As a result, Segment 520 from Otis to Stockton will be out of service longer than anticipated. This
operational notice is effective from ID1 Cycle, Gas Day Tuesday, August 25, 2026, until further notice.
With the above line out of service, primary and secondary firm quantities, as well as ITS/AOR are at risk
of not being scheduled. TIGT continues to work on alternative connections with affected customers to
facilitate scheduling of nominations.
TIGT will post updates as they become available.
For questions, please call your Account Director or Scheduling Representative at 303-763-2906.
Trunkline Gas Company

[Trunkline Gas Company] [Force Majeure] TGC Force Majeure REINSTATED: Kountze Station Additional Power Outages

SEV 4/5
Force Majeure Until Further Notice

Trunkline Gas Company has reinstated a force majeure at Kountze Compressor Station (MP -73.7) due to continued unexpected power outages caused by the landfall of Tropical Storm Edouard. The prior notification lifting the force majeure was rescinded effective immediately on 2026-09-03. Scheduling reductions are in effect with no end date specified, and updates will be posted as conditions develop.

TGC force majeure reinstatement at Kountze CS eliminates any relief priced into the prior FM lift notice -- expect bullish pressure at Trunkline ELA and tightening Gulf Coast-to-Midwest basis with no restoration timeline disclosed; no specific capacity volume stated but compressor outage on a major Gulf Coast northbound corridor carries meaningful flow reduction risk.
Reroute: Moderate: TETCO, ANR, and Southern Natural serve overlapping Gulf Coast-to-Midwest corridors and can absorb some displaced TGC volumes, though simultaneous storm-related stress on Gulf Coast infrastructure may limit available spare capacity on competing pipes.
View original notice text
Pipeline: Trunkline Gas Company
Notice ID: 68318
Notice Type: Force Majeure
Subject: TGC Force Majeure REINSTATED: Kountze Station Additional Power Outages
Posted: 2026-09-03 09:31:00.0
Effective: 2026-09-03 09:31:00.0
End Date: 

Notice ID: 68318
Notice Type: MAJ
Critical: Y
Reqrd Rsp Desc: No Response Required
Posting Date/Time: 2026-09-03 09:31:00.0
Subject: TGC Force Majeure REINSTATED: Kountze Station Additional Power Outages
Notice Effective Date/Time: 2026-09-03 09:31:00.0
Notice End Date/Time: 2200-01-01 00:00:00.0
Notice Text: 09/03/2026 TGC Force Majeure REINSTATED: Kountze Station Additional Power Outages Please disregard the earlier notification that the Trunkline Force Majeure was lifted. As of this time, this is to notify all contracted parties of Trunkline Gas Company that pursuant to Section 19 of the Trunkline FERC Gas Tariff, Trunkline has reinstated the Force Majeure event due to the continuation of the unexpected power outages at the Kountze Compressor Station (MP -73.7) related to the landfall of Tropical Storm Edouard. Effective Immediately and throughout the duration of this power outage, scheduling reductions will occur to reduce imbalances and maintain the safety and integrity of operations on the pipe. Updates will be posted as they become available. If you have any questions, please contact your Customer Service or Marketing Representative.
Tallgrass Energy

[Trailblazer Pipeline (TPC)] [FORCE MAJEURE] HEARTWELL LOCATION FORCE MAJEURE LOCATION (60487)

SEV 4/5
Force Majeure 0.008 Bcf/d

Trailblazer Pipeline declared a force majeure at its Heartwell Location (Location 60487) on Gas Day September 2, 2026, caused by electrical storms. Effective the ID2 cycle on September 2 and the Timely cycle on September 3, operating capacity at Heartwell is scheduled to 0 MDth/d until further notice. Primary and secondary firm quantities as well as ITS/AOR are explicitly stated to be at risk of not being scheduled.

Trailblazer FM at Heartwell zeros 0.008 Bcf/d of local capacity at Location 60487 with firm service at risk and no restoration timeline; while the isolated location impact is small, the force majeure declaration with 'until further notice' duration and primary firm curtailment language warrants monitoring -- Cheyenne Hub regional basis was already at -0.465 vs HH as of 2026-09-01 and any escalation to mainline throughput would pressure that spread further.
Reroute: None: Trailblazer shares Bertrand Compressor Station with REX, making REX a correlated rather than independent reroute option; the specific Heartwell location serves local delivery points with no identified bypass.
View original notice text
Pipeline: Trailblazer Pipeline (TPC)
Notice ID: 14063
Notice Type: Critical notice
Sub-Type: FORCE MAJEURE
Subject: HEARTWELL LOCATION FORCE MAJEURE LOCATION (60487)
Posted: 9/2/2026 4:08:05 PM
Effective: 9/2/2026 4:08:05 PM
End Date: 12/31/9000

HEARTWELL LOCATION FORCE MAJEURE LOCATION (60487)
On Gas Day Wednesday, September 2, 2026, Trailblazer Pipeline Company (“TPC”) experienced a Force
Majeure event (as defined in Section 22 of the GT&C of the Tariff) at its Heartwell Location as a result of
electrical storms in the vicinity. Effective ID2 cycle, Gas Day Wednesday, September 2, 2026, and Timely
cycle, Gas Day Thursday, September 3, 2026, and until further notice, the operating capacity at the
Heartwell Location (Location 60487) will be scheduled to 0 MDth/d.
At this capacity level, primary and secondary firm quantities as well as ITS/AOR may be at risk of not
being scheduled. Trailblazer will post updates as they are available.
For questions, please call your Account Director or Scheduling Representative at 303-763-2906.
Columbia Gulf Transmission (CGT)

Hampshire Compressor Station Maintenance (HampSEG), September 9 – November 25, 2026

SEV 4/5
Maintenance 0.340 Bcf/d 78 Days

CGT is scheduling maintenance at Hampshire Compressor Station (HampSEG) from September 9 through November 25, 2026 -- 78 calendar days. Backhaul capacity through HampSEG will be restricted to 2.200-2.350 Bcf/d against a design capacity of 2.541 Bcf/d, a reduction of approximately 0.190-0.340 Bcf/d (87-92% of design). CGT explicitly warns that Primary Firm, Secondary Firm, and Interruptible services are all at risk of curtailment, and Reservation Charge Credits have been triggered -- a firm-service curtailment notice, not merely an informational posting.

CGT HampSEG maintenance removes up to 0.340 Bcf/d of backhaul capacity from September 9 through November 25, with explicit risk of Primary Firm curtailments; Columbia Gulf mainline basis has been trading near -0.285 to -0.288 vs Henry Hub as of September 1 -- expect that spread to widen further as northbound backhaul capacity is squeezed during the shoulder/early-winter period, with modest bullish support for Transco Zone 4 and Gulf Coast downstream markets receiving less northbound competition for Gulf Coast gas.
Reroute: Moderate: Texas Eastern (TETCO) and Trunkline (TGC) serve overlapping Gulf Coast northbound corridors and provide partial backhaul alternatives; however, the 78-day duration and explicit firm curtailment risk mean alternative paths may face significant competition for remaining capacity, limiting full offset.
View original notice text
TSP Name Columbia Gulf Transmission, LLC
TSP 007854581
Notice Type Description: Maintenance

Notice Stat Desc: Initiate

Prior Notice: 

Critical: Y

Reqrd Rsp Desc: No Response Required
Post

Notice Effective

Notice End



Response
Post Date: 09/02/26

09/02/26

10/02/26
Subject: Subject: Hampshire Compressor Station Maintenance (HampSEG), September 9 – November 25, 2026
Author: Author: Dillon Schoolcraft
Notice Text
Columbia Gulf Transmission LLC (CGT) notifies customers of upcoming maintenance at Hampshire Compressor Station scheduled for Wednesday, September 9, 2026, through Wednesday, November 25, 2026. As a result, the backhaul capacity through HampSEG will be reduced to a level between 2,200,000 and 2,350,000 Dth effective Timely Cycle for Gas Day Wednesday, September 9, 2026.

CGT anticipates this restriction may result in curtailments to Interruptible, Secondary Firm, and Primary Firm services. Please see the details provided below for more information.

 HampSEG

·       Estimated Capacity Setting: 2,200,000 - 2,350,000 Dth

·       Design Capacity: 2,540,656

·       Posted Percentage: 87-92%

Due to the potential impact to firm service, CGT encourages customers to monitor the scheduled volumes on the Operationally Available Capacity screen on Informational Postings, as nominations can fluctuate based on market conditions.

Reservation Charge Credits (RCCs) will be determined per the process set forth in the General Terms and Conditions, Section 40 of CGT’s FERC Gas Tariff (Tariff). By means of this notice, CGT is establishing the 7-day Average Usage Quantity to be the period of August 20-26, 2026, pursuant to the provisions in the Tariff.

Please contact your Customer Services Representative with any questions.
Trunkline Gas Company

[Trunkline Gas Company] [Force Majeure] TGC Force Majeure: Kountze Station Power Outage

SEV 4/5
Force Majeure Until Further Notice

Trunkline Gas Company declared force majeure effective 2026-09-02 due to an unexpected power outage at the Kountze Compressor Station (MP -73.7) caused by Tropical Storm Edouard landfall. Scheduling reductions are being implemented immediately to reduce imbalances and maintain system integrity. No end date has been provided; duration is indeterminate pending power restoration.

TGC force majeure at Kountze CS removes northbound Gulf Coast-to-Midwest capacity with no stated restoration timeline; expect bullish pressure at Trunkline ELA and Henry Hub with possible widening at downstream Midwest delivery points as scheduled volumes are cut, with no concrete capacity figure available to quantify the reduction.
Reroute: Moderate: Texas Eastern (TETCO), Southern Natural (EGT), and ANR serve overlapping Gulf Coast northbound corridors, but tropical storm-related conditions affecting the broader Gulf Coast region may simultaneously limit alternative pipeline headroom.
View original notice text
Pipeline: Trunkline Gas Company
Notice ID: 68277
Notice Type: Force Majeure
Subject: TGC Force Majeure: Kountze Station Power Outage
Posted: 2026-09-02 09:37:00.0
Effective: 2026-09-02 09:37:00.0
End Date: 

Notice ID: 68277
Notice Type: MAJ
Critical: Y
Reqrd Rsp Desc: No Response Required
Posting Date/Time: 2026-09-02 09:37:00.0
Subject: TGC Force Majeure: Kountze Station Power Outage
Notice Effective Date/Time: 2026-09-02 09:37:00.0
Notice End Date/Time: 2200-01-01 00:00:00.0
Notice Text: 09/02/2026 TGC Force Majeure: Kountze Station Power Outage This is to notify all contracted parties of Trunkline Gas Company that pursuant to Section 19 of the Trunkline FERC Gas Tariff, Trunkline has declared a Force Majeure event due to an unexpected power outage at the Kountze Compressor Station (MP -73.7) related to the landfall of Tropical Storm Edouard. Effective Immediately and throughout the duration of this power outage, scheduling reductions will occur to reduce imbalances and maintain the safety and integrity of operations on the pipe. Updates will be posted as they become available. If you have any questions, please contact your Customer Service or Marketing Representative.
Rockies Express

[OPERATIONAL ALERT] BERTRAND COMPRESSOR STATION OPERATIONAL ISSUE - UPDATE #17

SEV 4/5
Capacity Constraint 1.085 Bcf/d

Rockies Express is restricting Segment 250 capacity to 1.085 Bcf/d westbound-to-eastbound (West to East direction) effective timely cycle Gas Day September 3, 2026, until further notice, due to an ongoing operational issue at Bertrand Compressor Station (Update #17). At this restriction level, primary firm, secondary firm, and ITS/AOR service classes are all explicitly at risk of curtailment. No restoration timeline has been provided.

REX Segment 250 restricted to 1.085 Bcf/d eastbound with primary firm at risk -- a multi-week unresolved constraint with no end date; REX Zone 3 delivered basis has averaged -0.313 vs HH over the five trading days ended 2026-09-01 (most recently -0.285 on 2026-09-01) and should widen further bearish as eastbound throughput remains capped, while Rockies/Cheyenne Hub faces bearish pressure from trapped westbound supply; Trailblazer shares Bertrand CS and is not an independent reroute.
Reroute: None: Trailblazer Pipeline (TPC) shares Bertrand Compressor Station with REX and is simultaneously constrained by the same facility -- the two are not independent reroutes for each other. The REX/TPC SALINE and TPC/REX LONE TREE WELD REC interconnects are both shown at 100% utilization (0.642 Bcf/d and 0.579 Bcf/d respectively, zero headroom) in current capacity data, corroborating the constraint.
View original notice text
Pipeline: Rockies Express
Notice ID: 14056
Notice Type: Critical notice
Sub-Type: OPERATIONAL ALERT
Subject: BERTRAND COMPRESSOR STATION OPERATIONAL ISSUE - UPDATE #17
Posted: 9/2/2026 9:25:29 AM
Effective: 9/2/2026 9:25:29 AM
End Date: 12/31/9000

BERTRAND COMPRESSOR STATION OPERATIONAL ISSUE – UPDATE #17
Effective Timely cycle, Gas Day Thursday, September 3, 2026, until further notice, the capacity in
Segment 250 is being restricted to 1,085 MDth/d in the West to East direction.
At this capacity level, primary and secondary firm quantities as well as ITS/AOR may be at risk of not
being scheduled. REX will post updates as they are available.
For questions, please call your Account Director or Scheduling Representative at 303-763-2906.
East Tennessee Natural Gas

09/09/2026- ETNG Pipeline Conditions for 09/10/2026

SEV 3/5
Informational

Pre-screen severity 3 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name: East Tennessee Natural Gas, LLC
Subject: ETNG Pipeline Conditions for 09/10/2026
Notice Type: Capacity Constraint
Critical Notice Description: Critical notice
Notice Status Description: Initiate
Notice Effective Date: 09/10/2026
Notice End Date: 09/11/2026
Posting Date: 09/09/2026
Notice Identifier: 182786
Required Response Indicator Description: No response required

For Gas Day September 10, 2026, East Tennessee Natural Gas (ETNG) has approved and scheduled nominations at each pipeline segment and meter station up to ETNG's operational capacity. The following locations have been restricted due to requested nominations exceeding ETNG's operational capacity:
Restricted Locations
Scheduled and Sealed
Priority % Restricted
Notes
Deliveries To Texas Eastern
100%
100%
Topside South
100%
100%
80%
Fordtown West - Westbound
100%
49%
Flatwoods East - Westbound
Yes
OFO / Imbalance Notice
OFO
---
Customer Specific OFO
---
Hourly Customer Specific OFO
---
Action Alert
---
Imbalances Warnings
Stay Balanced
Systemwide Notes:
ETNG requires any imbalance payback be coordinated through your Operations Account Representative.
If necessary, ETNG will utilize any provision of its tariff to ensure system integrity including the issuance of customer specific or system wide OFOs.
Effective October 1, 2025, MR 59200 - SNG Whitfield will be restricted to 0 Dth / d until further notice due to SNG pressures being lower than ETNG's typical operating pressure. Also, effective October 1, 2025, MR 59311 - SNG Bradley will be limited to its meter capacity of 31,000 Dth/d.
Customers are advised that capacity may become available as the nomination and confirmation process continues throughout the day.
Please contact your Operations Account Representative should you have any questions.
Algonquin Gas Transmission

09/09/2026- AGT Pipeline Conditions for 09/10/2026

SEV 3/5
Informational

Pre-screen severity 3 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name: Algonquin Gas Transmission, LLC
Subject: AGT Pipeline Conditions for 09/10/2026
Notice Type: Capacity Constraint
Critical Notice Description: Critical notice
Notice Status Description: Initiate
Notice Effective Date: 09/10/2026
Notice End Date: 09/11/2026
Posting Date: 09/09/2026
Notice Identifier: 182804
Required Response Indicator Description: No response required

For Gas Day September 10, 2026, Algonquin Gas Transmission (AGT) has approved and scheduled nominations at each pipeline segment and meter station up to AGT's operational capacity. The following locations have been restricted due to requested nominations exceeding AGT's operational capacity:
Restricted Locations
Scheduled and Sealed
Priority % Restricted
Notes
Stony Point
100%
100%
100%
100%
100%
100%
100%
10%
Planned Outage
Cromwell
100%
100%
49%
Burrillville
100%
100%
50%
Weymouth
100%
100%
62%
Iroquois Deliveries
100%
100%
46%
Iroquois Receipts
Yes
Hanover West
Yes
Mendon Receipts
100%
100%
100%
100%
100%
58%
Lincoln Receipts
Yes
Lincoln Deliveries
Yes
G System
100%
100%
16%
C System
Yes
Centerville-Transco Receipts (1)
100%
100%
15%
I-8 West to East
Yes
No-Notice Restrictions
---
OFO / Imbalance Notice
System Wide OFO
---
Customer Specific OFO
---
Meter Specific OFO
---
Customer Specific Hourly OFO
---
Imbalances Warnings
Stay Balanced
FERC Order 698
Yes
Systemwide Notes:
(1) AGT has scheduled Transco Centerville receipts to the design meter capacity of 222,526 Dth/d.
AGT requests that customers/point operators on AGT be aware of the impact non-ratable hourly takes from the system may have in causing delivery pressures reaching lower than desired levels.
AGT's system is not designed to sustain delivery pressures above contract levels while making non-ratable/accelerated deliveries above scheduled quantities for more than 6 consecutive hours, to be followed by flows below scheduled quantity for the balance of any 24-hour period. If customers/point operators don't manage hourly takes from the system, 1) delivery pressures will be impacted and /or 2) AGT may be required to impose further restrictions or courses of action in order to maintain the operational integrity of the system.
AGT may be required to issue system specific, meter specific and/or hourly OFO's pursuant to General Terms and Conditions Section 26.7(d) to impose further restrictions in order to maintain the operational integrity of the system.
Customers are advised that capacity may become available as the nomination and confirmation process continues throughout the day.
Please contact your Operations Account Representative should you have any questions.
Columbia Gas Transmission (TCO)

Operational Alert – Potential Critical Days & Receipt Point OFO, Effective September 12, 2026

SEV 3/5
Informational Until Further Notice

Pre-screen severity 3 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name Columbia Gas Transmission, LLC
TSP 054748041
Notice Type Description: Operational Alert

Notice Stat Desc: Initiate

Prior Notice: 

Critical: Y

Reqrd Rsp Desc: No Response Required
Post

Notice Effective

Notice End



Response
Post Date: 09/09/26

09/09/26

10/09/26
Subject: Subject: Operational Alert – Potential Critical Days & Receipt Point OFO, Effective September 12, 2026
Author: Author: Jonah Skiles
Notice Text
In an effort to communicate current operating conditions to customers, Columbia Gas Transmission, LLC (TCO) is issuing the following Operational Alert effective Saturday, September 12, 2026, and continuing until further notice. 

 

Potential Critical Day for Storage Injections: 

It may become necessary for TCO to limit storage injections to firm quantities only, which would constitute a Critical Day in storage, as early as Gas Day Saturday, September 12, 2026. The potential for a Storage Critical Day is due primarily to forecasted mild weather, higher storage and line pack levels, and reduced market demand resulting in increased daily injections into customer’s storage accounts. Customers can assist TCO operations and reduce the potential need for a Critical Day by not exceeding their Maximum Daily Injection Quantities and keeping supplies and markets balanced. 

Firm Storage Service (FSS) shippers are reminded that, per section 3(c) of the FSS Rate Schedule, the Maximum Monthly Injection Quantity (MMIQ) for September is 13% of the Storage Contract Quantity (SCQ), and the Maximum Daily Injection Quantity (MDIQ) is 1/25th of the MMIQ. 

 

Pre OFO – Receipt Points in Market Areas 26, 30, 35, 41, 42:

TCO notifies all Shippers under all Transportation Rate Schedules within its FERC Gas Tariff, and Meter Operators in Market Areas 26, 30, 35, 41, and 42, that the issuance of an Operational Flow Order (OFO) may become necessary beginning as early as September 12, 2026, to preserve system integrity and protect the operating performance of TCO’s pipeline system.

Pursuant to Section 17.1(d) of the General Terms and Conditions of its Tariff, TCO is providing advanced warning of the operational variables that may in the future give rise to the issuance of an OFO. The operational variables that may require issuance of an OFO in the future are the following.

 

Due to forecasted mild weather and the anticipated lower market demand, TCO has experienced excess receipts during a time when storage and line pack levels are high. TCO has limited operational flexibility for positive imbalances and cannot allow actual receipts to exceed scheduled receipts.

 

In order to avoid the issuance of an OFO, receipt points must be balanced such that actual receipts into Market Areas 26, 30, 35, 41, and 42 are equal to or less than the scheduled receipt quantities in these Areas. Any excess receipts can threaten the operational integrity of TCO’s system and TCO’s ability to maintain its firm obligations. An OFO may also be avoided if Shippers and Meter Operators adjust nominations to align with flowing supplies during each nomination cycle. 

 

In the event TCO is forced to issue an OFO, Shippers who do not comply will be subject to penalties in accordance with Section 19.3 of TCO’s Tariff.

Imbalances and AutoPAL:

As noted above, TCO has limited operational flexibility for positive imbalances, including positive AutoPAL balances. Physical flows must match scheduled quantities to prevent further action. As a reminder, the intent of the AutoPAL service is to utilize nominal quantities to resolve minor pool imbalances that result from small upstream or downstream reductions during the cycles of the Gas Day. These quantities are then paid back the next cycle of the Gas Day. 

TCO will monitor AutoPAL activity and reserves the right to adjust the current AutoPAL limits, make AutoPAL unavailable, or declare an OFO to prevent abuse.  

TCO encourages customers to monitor critical notices, including the Daily Capacity Posting, for updates. Please contact your Customer Services or Marketing Representative with any questions.
El Paso Natural Gas (EPNG)

[OPERATIONAL FLOW ORDER] SOC Declaration- Location Specific DRAFT

SEV 3/5
Informational

Pre-screen severity 3 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Pipeline: El Paso Natural Gas (EPNG)
Notice Type: OPERATIONAL FLOW ORDER
Subject: SOC Declaration- Location Specific DRAFT
Posted: 09/09/2026 8:23:21AM
Effective: 09/09/2026 8:23:21AM
End Date: 09/10/2026 9:00:00AM

TSP/TSP Name:  8001703-EL PASO NATURAL GAS CO. L.L.C. Critical: Y
Notice Type Desc (1):  OPERATIONAL FLOW ORDER Notice Type Desc (2):  OFO
Notice Eff Date/Time:  09/09/2026 8:23:21AM Notice End Date/Time:  09/10/2026 9:00:00am
Post Date/Time:  9/9/2026 8:23:21 AM Notice ID: 629586
Reqrd Rsp:  5 Rsp Date/Time: 
Notice Stat Desc:  INITIATE Prior Notice: 
Subject:  SOC Declaration- Location Specific DRAFT
Notice Text:
STRAINED OPERATING CONDITION (SOC) Declaration – Location Specific DRAFT
EFFECTIVE DATE: September 9, 2026.
IMBALANCE TOLERANCE: 5%
DURATION:  Until Further Notice
AFFECTED AREAS/LOCATIONS:  Specific to the following locations:
DAPS PHX (300777)
IBLYTHE (314980)
DTEP S78 (301149)
OPERATING CONDITION SUMMARY:   The EPNG system linepack level starts Gas Day September 9, 2026, at 7,510 MMcf which is decrease of 127 MMcf compared to the start of Gas Day September 8, 2026.  The locations listed above continue to draft the system and undermine our ability to maintain linepack within acceptable levels.
Deliveries in excess of scheduled quantities.
CUSTOMER ACTION REQUIRED:  Immediate action is required to ensure that system pressure remain at a level capable of meeting scheduled deliveries off the system.
EPNG RESPONSE:
- Washington Ranch is available for withdrawal.
- IHSW Service will be suspended.
REFERENCE INFORMATION:
For scheduling questions, please call your scheduling representative at (800) 238-3764.
For operational and capacity questions, please call Russ Pyeatt at (719) 520-3729, John Althoff at (719) 667-7750, Dan English at (719) 520-4722, or Morgan McCasland at (719) 520-4339.
For media inquiries, please contact media relations at newsroom@kindermorgan.com.
Transwestern Pipeline

[Transwestern Pipeline] [Operational Alert] CRITICAL NOTICE - SAME DAY - OVERAGE ALERT - PHOENIX AREA

SEV 3/5
Informational

Pre-screen severity 3 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Pipeline: Transwestern Pipeline
Notice ID: 120502
Notice Type: Operational Alert
Subject: CRITICAL NOTICE - SAME DAY - OVERAGE ALERT - PHOENIX AREA
Posted: Sep 9 2026 7:44AM
Effective: Sep 9 2026 7:43AM
End Date: Sep 10 2026 8:59AM

Notice Type Description: Operational Alert
Notice Identifier: 120502
Critical Notice Description: Critical notice
Posting Date/Time: Sep 9 2026 7:44AM
Notice Status Description: Initiate
Required Response Indicator Description: No response required
TSP: 7933047
TSP Name: TRANSWESTERN PIPELINE COMPANY, LLC
Subject: CRITICAL NOTICE - SAME DAY - OVERAGE ALERT - PHOENIX AREA
Notice Effective Date/Time: Sep 9 2026 7:43AM
Notice End Date/Time: Sep 10 2026 8:59AM
Notice Text: CRITICAL NOTICE - SAME DAY - OVERAGE ALERT - PHOENIX AREASeptember 9, 2026Due to low line pack in the Phoenix Area, Transwestern is declaring a Same Day Overage Alert in the Phoenix Area for the current gas day, September 9, 2026.Any Operator of a delivery point in the Phoenix Area at which actual quantities exceed scheduled quantities on this Alert Day shall be subject to Alert Day charges in accordance with Section 22.4 of the General Terms and Conditions of Transwestern's FERC Gas Tariff.Based upon current operating conditions, Transwestern anticipates that this low line pack condition will continue at least for the entire current gas day. Transwestern will provide additional information concerning this Alert Day condition as necessary.
Transco

Updated - Market and Production Constraints

SEV 3/5
Informational Until Further Notice

Pre-screen severity 3 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Pipeline: Transco
Notice: Updated - Market and Production Constraints
Posted: 09/09/2026 07:00:06 CDT
Notice ID: 17254758

TRANSCONTINENTAL GAS PIPE LINE COMPANY, LLC

Critical:
 Y

Notice Eff Date:
 09/09/2026

Notice Eff Time:
 07:00:06 CDT

Notice End Date:
 

Notice End Time:
 

Notice ID:
 17254758

Notice Stat Desc:
 Supersede

Notice Type Desc:
 Constraint

Post Date:
 09/09/2026

Post Time:
 07:00:06 CDT

Prior Notice:
 17251448

Reqrd Rsp Desc:
 No response required

Rsp Date:
 

Rsp Time:
 

TSP:
 007933021

TSP Name:
 TRANSCONTINENTAL GAS PIPE LINE COMPANY, LLC

Notice Text: 
Subject: 
Updated - Market and Production Constraints
The available capacity listed below in each section will become effective 
September 10, 2026
. Changes from the previous gas day are highlighted in 
bold
.
The following chart reflects the quantity of available transportation capacity including Primary, Non-Secondary Reverse Path (NSRP), Secondary Firm, and Interruptible at various Throughput Section Boundary (TSB) locations or segment constraints. These TSBs are identified as receipt or delivery based.
 
Maintenance TSB Constraints
Loc ID
Location Name
ZN
Del/Rec
Type of TSB
Available Capacity Mdt/d
Highest Priority Included*
Flow Dir
Job #
9010778
Central Penn Line South N to S MP 1.0
6
Del
M-L
2,000
PRIMARY
N-S
355854
 
9013363
 
COMPRESSOR STATION W 50 MP
517.23
 
3
Del
M-L
OPEN
 Primary
 S-N
361708
 
9012483
 
Sta 80 MP 740.501
 
4
Del
M-L
2,351
 Primary
S-N
596608
 *The priority listed in addition to all lower priorities will be subject to the Available Capacity. If the priority listed references “Only”, only the priority listed will be allowed and subject to the Available Capacity; All lower priorities will not be allowed.
 
System TSB Constraints
Loc ID
Location Name
ZN
Del/Rec
Type of TSB
Available Capacity Mdt/d
Highest Priority Included*
Flow Dir
9011140
Mainline MP 438.84
 2
 Rec
 L
709
PRIMARY
S to N
9000000
Compressor Station 60 MP 588.62
3
Rec
Loc
0
NSRP
S to N
9011460
SWLA Lat N to S MP 1.0
 2
 Del
 L
40
NSRP
N to S
9011260
SELA N to S MP 85.93
 3
 Rec
 L
0
PRIMARY
N to S
9011261
SELA S to N MP 85.94
 3
  Rec
 L
0
PRIMARY
S to N
9001620
Mobile Bay Lat South Asc MP 20
 4A
  Del
 L
25
NSRP
N to S
5000048
TSB MP 1412.98 to MP 1369.45
 5
  Del
 S
0
NSRP
N to S
1001280
S Virginia Lat Sta 167 MP 69.12
 5
  Del
 L
0
SECONDARY
N to S
5000033
TSB MP 1413.00 to MP 1519.92
 5
  Del
 S
200
NSRP
N to S
5000039
TSB MP 1519.93 to MP 1586.30
 5
 Del
S
200
NSRP
N to S
5000040
TSB MP 1586.30 to 1674.56
 5,6
 Del
S
200
NSRP
N to S
9010778
Central Penn South N to S TSB MP 1.00
 6
 Del
L
0
SECONDARY
N to S
9008342
Marcus Hook Lateral TSB MP 1.10
 6
 Del
L
200
SECONDARY
N to S
9012063
Marcus Hook Lateral TSB MP 18.71
 6
 Del
L
OPEN
 
N to S
9008343
Trenton Woodbury Lateral TSB MP 1.00
 6
 Del
L
200
SECONDARY
N to S
9007422
Station 207 Lower Bay Lateral MP 8.57
 6
 Del
L
447
SECONDARY
W to E
9008482
NY Bay Lateral MP 35.00
 6
 Del
L
0
SECONDARY
W to E
9008866
Mainline Milltown MP 1790.85
 6
 Del
L
0
NSRP
S to N
1001300
Linden MP 1808.191
 6
 Del
L
50
NSRP
S to N
9010838
Rivervale Lat. North NJ Ext. MP 19.0
 6
 Rec
L
0
SECONDARY
N to S
9007462
Leidy Station 517 W MP 127.949
 6
 Del
L
400
NSRP
E to W
9007463
Leidy Station 520 W MP 170.389
 6
 Del
L
400
NSRP
E to W
9008462
Leidy Line West End MP 205.00
 6
 Del
L
400
NSRP
E to W
*The priority listed in addition to all lower priorities will be subject to the Available Capacity. If the priority listed references “Only”, only the priority listed will be allowed and subject to the Available Capacity; All lower priorities will not be allowed.
 
Location TSB (L); Segment TSB (S); Maintenance Location TSB (M-L)
The following chart reflects the quantity of available High Burn Limit Value (HBLV) no-notice swing service including Non-Traditional (NT Swing), Secondary (Sec Swing) and Interruptible (IT Swing) at various location or segment HBLV constraints.
Loc/Seg ID
HBLV Location/Segment Constraint
Zone
Type of HBLV
Available Swing Mdt/d
Highest Priority Included
5000027
Zone 1 Segment
1
S
1
Secondary
5000028
Zone 2 Segment
2
S
0
Secondary
5000029
Zone 3 Segment
3
S
0
Secondary
5000030
Zone 4 Segment
4
S
0
Secondary
5000031
Zone 5 Segment
5
S
0
Secondary
5000032
Zone 6 Segment
6
S
0
Secondary
Location (L); Segment (S)
The following chart reflects the quantity of available High Burn Limit Value (HBLV) no-notice swing service including Non-Traditional (NT Swing), Secondary (Sec Swing) and Interruptible (IT Swing) at various location or segment HBLV constraints.
Loc ID
Location Name
Zone
Del/Rec
Single Point or Group
Available Capacity Mdt/d
9003442
Pine Prairie Stg
 3
 Rec
 L
900
9003442
Pine Prairie Stg
 3
 Del
 L
***
9010378
TOD Leidy West Aggregate Receipt MP 101.00
 6
 Rec
 G
OPEN
9010379
TOD Leidy East Aggregate Receipt MP 101.00
 6
 Rec
 G
OPEN
9007682
Leidy Line Aggregate Receipt MP 101.00
 6
 Rec
 G
OPEN
9001342
Martins Creek #3
 6
 Rec
 L
43
1006561
Algonquin - Ctr M4402
 6
 Del
 L
135**
9007962
Raceland I/C
 3
 Del
 L
40
1004123
Terrebonne Sta 62 I/C
 3
 Del
 L
85
1006304
Vinton FGT Meter 4381
 2
 Del
 L
0
9002300
POOLE ROAD
1 
 Del
 L
80
Location (L); Aggregate of Locations (G)
Leidy Aggregate Receipts consist of: Puddlefield, Carverton and Chapin
Markham Aggregate Deliveries consist of:  Markham Channel, Markham Valero, Markham SW #1, and Poole Road
TOD Leidy West consists of: Puddlefield, Carverton and Chapin
TOD Leidy East consists of: Puddlefield, Carverton and Chapin
** Non-Traditional and Lower Priorities
*** Delivery qty. available only by displacement of scheduled receipt qty.
To the extent that the total nominated quantities or requested HBLV quantities exceed the available capacity/swing in the charts identified above, Transco will adjust these quantities based on its priority of service, in accordance with the General Terms and Conditions of Transco's FERC Gas Tariff.
This information is provided as a summary of significant information that coincides with information currently available under Transco's Operational Capacity report and is intended to provide customers with an easy reference source. Transco may be required to institute capacity restrictions at locations or in segments other than those identified above if operational conditions dictate. As operational conditions change, Transco will provide notice, via 1Line, of any additional segments or locations where transportation services or HBLVs may be limited and of any changes in available capacity in any of the identified areas.
If you have any questions, please contact your Commercial Services Representative.
East Tennessee Natural Gas

09/08/2026- ETNG Pipeline Conditions for 9/9/2026

SEV 3/5
Informational

Pre-screen severity 3 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name: East Tennessee Natural Gas, LLC
Subject: ETNG Pipeline Conditions for 9/9/2026
Notice Type: Capacity Constraint
Critical Notice Description: Critical notice
Notice Status Description: Initiate
Notice Effective Date: 09/09/2026
Notice End Date: 09/10/2026
Posting Date: 09/08/2026
Notice Identifier: 182722
Required Response Indicator Description: No response required

For Gas Day September 9, 2026, East Tennessee Natural Gas (ETNG) has approved and scheduled nominations at each pipeline segment and meter station up to ETNG's operational capacity. The following locations have been restricted due to requested nominations exceeding ETNG's operational capacity:
Restricted Locations
Scheduled and Sealed
Priority % Restricted
Notes
Deliveries To Texas Eastern
100%
100%
Topside South
100%
100%
80%
Fordtown West - Westbound
Yes
Flatwoods East - Westbound
Yes
OFO / Imbalance Notice
OFO
---
Customer Specific OFO
---
Hourly Customer Specific OFO
---
Action Alert
---
Imbalances Warnings
Stay Balanced
Systemwide Notes:
ETNG requires any imbalance payback be coordinated through your Operations Account Representative.
If necessary, ETNG will utilize any provision of its tariff to ensure system integrity including the issuance of customer specific or system wide OFOs.
Effective October 1, 2025, MR 59200 - SNG Whitfield will be restricted to 0 Dth / d until further notice due to SNG pressures being lower than ETNG's typical operating pressure. Also, effective October 1, 2025, MR 59311 - SNG Bradley will be limited to its meter capacity of 31,000 Dth/d.
Customers are advised that capacity may become available as the nomination and confirmation process continues throughout the day.
Please contact your Operations Account Representative should you have any questions.
Texas Eastern Transmission (TETCO)

09/08/2026- TE Pipeline Conditions for 9/9/2026

SEV 3/5
Informational

Pre-screen severity 3 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name: Texas Eastern Transmission, LP
Subject: TE Pipeline Conditions for 9/9/2026
Notice Type: Capacity Constraint
Critical Notice Description: Critical notice
Notice Status Description: Initiate
Notice Effective Date: 09/09/2026
Notice End Date: 09/10/2026
Posting Date: 09/08/2026
Notice Identifier: 182703
Required Response Indicator Description: No response required

For Gas Day September 9, 2026, Texas Eastern (TE) has approved and scheduled nominations at each pipeline segment and meter station up to TE's operational capacity. The following locations have been restricted due to requested nominations exceeding TE's operational capacity:
Restricted Locations
Scheduled and Sealed
Priority % Restricted
Notes
TABS
North of Berne
Meter 75919 Deliveries
N/A
100%
100%
85%
Rec from AGT & Del West of Lambertville
100%
100%
100%
TE/AGT Lease
Yes
To Lease Capacity
Nexus/TE Leased Meters
Yes
To Lease Capacity
30" South of Berne
Berne - Southbound
N/A
100%
100%
Danville - Southbound
N/A
100%
100%
Tompkinsville - Southbound
N/A
100%
100%
Barton - Southbound
N/A
100%
100%
24"
Sarahsville - Southbound
N/A
100%
99%
Five Points - Southbound
N/A
100%
75%
Lebanon
N/A
100%
70%
Lebanon Lateral
N/A
100%
96%
Batesville - Southbound
N/A
100%
38%
Meter 74215 Deliveries
Yes
Access Area
Union Church - Southbound
N/A
100%
90%
New Roads South - Southbound
N/A
100%
95%
White Castle - Southbound
N/A
100%
95%
Longview - Northbound
N/A
100%
32%
Huntsville - Northbound
Yes
Speaks - Southbound
N/A
100%
81%
Angleton West - Northbound
N/A
100%
82%
Vidor East - Northbound
N/A
100%
13%
Deliveries to BIG
N/A
100%
100%
100%
100%
59%
Planned Outage
Gillis - Northbound
N/A
100%
51%
TABS Pool Restrictions - Tolerances
ETX
STX
WLA
ELA
M1-24"
M1-30"
M2-24"
M2-30"
TABS Pool - Length
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
TABS Pool - Short
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
No-Notice Restrictions
OFO / Imbalance Notice
OFO
---
Action Alert
---
Customer Specific OFO
---
Imbalance Warnings
Stay Balanced - Access Area, M1-24, M1-30,M2-24, M2-30, and M3
FERC Order 698
M2-24, M2-30 and M3
Gas Quality:
Due to gas quality issues, meter 76609 has been shut in and physical receipts at the meter will be unavailable until further notice.  Beginning during the Timely cycle for Gas Day December 6, 2025, and until further notice, TE will restrict receipt nominations at Meter 76609 to -0- Dth/d.
Systemwide Notes:
Shippers in all Texas Eastern's Access Area Zones and Market Area Zones M1-30, M2-30 and M3 are required to coordinate any imbalance payback through TE's account representative and actual payback quantities may be limited depending on system operations and conditions. If customers do not adhere to imbalance requirements stated above, TE will utilize any provision of its tariff to ensure system integrity including the issuance of customer specific or system wide OFOs.
Please contact your Operations Account Representative should you have any questions.
Millennium Pipeline (MPC)

Highland CS Maintenance September 15th

SEV 3/5
Informational Until Further Notice

Pre-screen severity 3 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name Millennium Pipeline Company, L.L.C.
TSP 607821050
Notice Type Description: Maintenance

Notice Stat Desc: Initiate

Prior Notice: 

Critical: Y

Reqrd Rsp Desc: No Response Required
Post

Notice Effective

Notice End



Response
Post Date: 09/08/26

09/08/26

10/08/26
Subject: Subject: Highland CS Maintenance September 15th
Author: Author: Ulises Osorio
Notice Text
Millennium Pipeline Company (MPC) would like to remind customers of the upcoming maintenance at the Highland Compressor Station beginning with the Timely cycle for Gas Day Tuesday, September 15, 2026.  

Please note, this includes reduced segment capacity, as listed below: 

Wagoner (WAGONERW) will be restricted as follows:

Total Capacity                          1,065,000

Point(s) Restriction(s)

There are no point specific restrictions necessary for this outage. 

AutoPAL Availability

At this time, AutoPAL remains available.

As a reminder to customers, the intent of the AutoPAL service is to utilize nominal quantities to resolve minor pool imbalances that result from small upstream or downstream reductions during the Gas Day. These quantities are then paid back the next cycle of the Gas Day.

MPC will monitor AutoPAL activity and reserves the right to make AutoPAL unavailable.

RCC’s

Reservation Charge Credits will be determined per the process set forth in Section 15 of MPC’s FERC Gas tariff.

Questions

If you have questions, please contact Customer Services at 866-581-6487.

Please continue to monitor our Critical Notices for updates on progress as well.
Northern Border Pipeline (NBPL)

Northern Border High Inventory OFO Watch September 8, 2026

SEV 3/5
Informational Until Further Notice

Pre-screen severity 3 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name Northern Border Pipeline Company
TSP 021632583
Notice Type Description: Operational Flow Order

Notice Stat Desc: Initiate

Prior Notice: 

Critical: Y

Reqrd Rsp Desc: No Response Required
Post

Notice Effective

Notice End



Response
Post Date: 09/08/26

09/08/26

10/08/26
Subject: Subject: Northern Border High Inventory OFO Watch September 8, 2026
Author: Author: Micah Harp
Notice Text
Northern Border Pipeline is issuing an OFO Watch, effective immediately. Northern Border is concerned about the operational integrity of its system as a result of high line pressure. The OFO watch is in effect until further notice. 

 

In order to allow for the Northern Border pipeline system to maintain its operational integrity. Northern Border has limited flexibility to manage imbalances and strongly encourages all shippers to manage their system requirements to ensure the matching of receipts and deliveries daily. All operators should contact NBPL Gas Control for any imbalance payback until further notice.

 

Absent voluntary imbalance management by shippers to ensure daily balancing, Northern Border may be required to take further action, including the immediate issuance of an imbalance Operational Flow Order. If further action is required, it may be necessary for that action to become effective immediately, with no additional prior notice available.

 

This posting will be updated as more information becomes available.

 

Please contact your Northern Border Customer Service Representative with any questions regarding nominations or scheduling at (866) 581-6487.
Transco

Updated - Market and Production Constraints

SEV 3/5
Informational Until Further Notice

Pre-screen severity 3 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Pipeline: Transco
Notice: Updated - Market and Production Constraints
Posted: 09/08/2026 07:18:55 CDT
Notice ID: 17251448

TRANSCONTINENTAL GAS PIPE LINE COMPANY, LLC

Critical:
 Y

Notice Eff Date:
 09/08/2026

Notice Eff Time:
 07:18:55 CDT

Notice End Date:
 

Notice End Time:
 

Notice ID:
 17251448

Notice Stat Desc:
 Supersede

Notice Type Desc:
 Constraint

Post Date:
 09/08/2026

Post Time:
 07:18:55 CDT

Prior Notice:
 17224055

Reqrd Rsp Desc:
 No response required

Rsp Date:
 

Rsp Time:
 

TSP:
 007933021

TSP Name:
 TRANSCONTINENTAL GAS PIPE LINE COMPANY, LLC

Notice Text: 
Subject: 
Updated - Market and Production Constraints
The available capacity listed below in each section will become effective 
September 9, 2026
. Changes from the previous gas day are highlighted in 
bold
.
The following chart reflects the quantity of available transportation capacity including Primary, Non-Secondary Reverse Path (NSRP), Secondary Firm, and Interruptible at various Throughput Section Boundary (TSB) locations or segment constraints. These TSBs are identified as receipt or delivery based.
 
Maintenance TSB Constraints
Loc ID
Location Name
ZN
Del/Rec
Type of TSB
Available Capacity Mdt/d
Highest Priority Included*
Flow Dir
Job #
9010778
Central Penn Line South N to S MP 1.0
6
Del
M-L
2,000
PRIMARY
N-S
355854
 
9013363
 
COMPRESSOR STATION W 50 MP
517.23
 
3
Del
M-L
1,435
 Primary
 S-N
361708
 
9012483
 
Sta 80 MP 740.501
 
4
Del
M-L
2,351
 Primary
S-N
596608
 *The priority listed in addition to all lower priorities will be subject to the Available Capacity. If the priority listed references “Only”, only the priority listed will be allowed and subject to the Available Capacity; All lower priorities will not be allowed.
 
System TSB Constraints
Loc ID
Location Name
ZN
Del/Rec
Type of TSB
Available Capacity Mdt/d
Highest Priority Included*
Flow Dir
9011140
Mainline MP 438.84
 2
 Rec
 L
709
PRIMARY
S to N
9000000
Compressor Station 60 MP 588.62
3
Rec
Loc
0
NSRP
S to N
9011460
SWLA Lat N to S MP 1.0
 2
 Del
 L
40
NSRP
N to S
9011260
SELA N to S MP 85.93
 3
 Rec
 L
0
PRIMARY
N to S
9011261
SELA S to N MP 85.94
 3
  Rec
 L
0
PRIMARY
S to N
9001620
Mobile Bay Lat South Asc MP 20
 4A
  Del
 L
25
NSRP
N to S
5000048
TSB MP 1412.98 to MP 1369.45
 5
  Del
 S
0
NSRP
N to S
1001280
S Virginia Lat Sta 167 MP 69.12
 5
  Del
 L
0
SECONDARY
N to S
5000033
TSB MP 1413.00 to MP 1519.92
 5
  Del
 S
200
NSRP
N to S
5000039
TSB MP 1519.93 to MP 1586.30
 5
 Del
S
200
NSRP
N to S
5000040
TSB MP 1586.30 to 1674.56
 5,6
 Del
S
200
NSRP
N to S
9010778
Central Penn South N to S TSB MP 1.00
 6
 Del
L
0
SECONDARY
N to S
9008342
Marcus Hook Lateral TSB MP 1.10
 6
 Del
L
200
SECONDARY
N to S
9012063
Marcus Hook Lateral TSB MP 18.71
 6
 Del
L
OPEN
 
N to S
9008343
Trenton Woodbury Lateral TSB MP 1.00
 6
 Del
L
200
SECONDARY
N to S
9007422
Station 207 Lower Bay Lateral MP 8.57
 6
 Del
L
447
SECONDARY
W to E
9008482
NY Bay Lateral MP 35.00
 6
 Del
L
0
SECONDARY
W to E
9008866
Mainline Milltown MP 1790.85
 6
 Del
L
0
NSRP
S to N
1001300
Linden MP 1808.191
 6
 Del
L
50
NSRP
S to N
9010838
Rivervale Lat. North NJ Ext. MP 19.0
 6
 Rec
L
0
SECONDARY
N to S
9007462
Leidy Station 517 W MP 127.949
 6
 Del
L
400
NSRP
E to W
9007463
Leidy Station 520 W MP 170.389
 6
 Del
L
400
NSRP
E to W
9008462
Leidy Line West End MP 205.00
 6
 Del
L
400
NSRP
E to W
*The priority listed in addition to all lower priorities will be subject to the Available Capacity. If the priority listed references “Only”, only the priority listed will be allowed and subject to the Available Capacity; All lower priorities will not be allowed.
 
Location TSB (L); Segment TSB (S); Maintenance Location TSB (M-L)
The following chart reflects the quantity of available High Burn Limit Value (HBLV) no-notice swing service including Non-Traditional (NT Swing), Secondary (Sec Swing) and Interruptible (IT Swing) at various location or segment HBLV constraints.
Loc/Seg ID
HBLV Location/Segment Constraint
Zone
Type of HBLV
Available Swing Mdt/d
Highest Priority Included
5000027
Zone 1 Segment
1
S
1
Secondary
5000028
Zone 2 Segment
2
S
0
Secondary
5000029
Zone 3 Segment
3
S
0
Secondary
5000030
Zone 4 Segment
4
S
0
Secondary
5000031
Zone 5 Segment
5
S
0
Secondary
5000032
Zone 6 Segment
6
S
0
Secondary
Location (L); Segment (S)
The following chart reflects the quantity of available High Burn Limit Value (HBLV) no-notice swing service including Non-Traditional (NT Swing), Secondary (Sec Swing) and Interruptible (IT Swing) at various location or segment HBLV constraints.
Loc ID
Location Name
Zone
Del/Rec
Single Point or Group
Available Capacity Mdt/d
9003442
Pine Prairie Stg
 3
 Rec
 L
900
9003442
Pine Prairie Stg
 3
 Del
 L
***
9010378
TOD Leidy West Aggregate Receipt MP 101.00
 6
 Rec
 G
OPEN
9010379
TOD Leidy East Aggregate Receipt MP 101.00
 6
 Rec
 G
OPEN
9007682
Leidy Line Aggregate Receipt MP 101.00
 6
 Rec
 G
OPEN
9001342
Martins Creek #3
 6
 Rec
 L
43
1006561
Algonquin - Ctr M4402
 6
 Del
 L
135**
9007962
Raceland I/C
 3
 Del
 L
40
1004123
Terrebonne Sta 62 I/C
 3
 Del
 L
85
1006304
Vinton FGT Meter 4381
 2
 Del
 L
0
9002300
POOLE ROAD
1 
 Del
 L
80
Location (L); Aggregate of Locations (G)
Leidy Aggregate Receipts consist of: Puddlefield, Carverton and Chapin
Markham Aggregate Deliveries consist of:  Markham Channel, Markham Valero, Markham SW #1, and Poole Road
TOD Leidy West consists of: Puddlefield, Carverton and Chapin
TOD Leidy East consists of: Puddlefield, Carverton and Chapin
** Non-Traditional and Lower Priorities
*** Delivery qty. available only by displacement of scheduled receipt qty.
To the extent that the total nominated quantities or requested HBLV quantities exceed the available capacity/swing in the charts identified above, Transco will adjust these quantities based on its priority of service, in accordance with the General Terms and Conditions of Transco's FERC Gas Tariff.
This information is provided as a summary of significant information that coincides with information currently available under Transco's Operational Capacity report and is intended to provide customers with an easy reference source. Transco may be required to institute capacity restrictions at locations or in segments other than those identified above if operational conditions dictate. As operational conditions change, Transco will provide notice, via 1Line, of any additional segments or locations where transportation services or HBLVs may be limited and of any changes in available capacity in any of the identified areas.
If you have any questions, please contact your Commercial Services Representative.
Transwestern Pipeline

[Transwestern Pipeline] [Operational Alert] CRITICAL NOTICE - SAME DAY - OVERAGE ALERT - PHOENIX AREA

SEV 3/5
Informational

Pre-screen severity 3 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Pipeline: Transwestern Pipeline
Notice ID: 120487
Notice Type: Operational Alert
Subject: CRITICAL NOTICE - SAME DAY - OVERAGE ALERT - PHOENIX AREA
Posted: Sep 8 2026 7:03AM
Effective: Sep 8 2026 7:01AM
End Date: Sep 9 2026 8:59AM

Notice Type Description: Operational Alert
Notice Identifier: 120487
Critical Notice Description: Critical notice
Posting Date/Time: Sep 8 2026 7:03AM
Notice Status Description: Initiate
Required Response Indicator Description: No response required
TSP: 7933047
TSP Name: TRANSWESTERN PIPELINE COMPANY, LLC
Subject: CRITICAL NOTICE - SAME DAY - OVERAGE ALERT - PHOENIX AREA
Notice Effective Date/Time: Sep 8 2026 7:01AM
Notice End Date/Time: Sep 9 2026 8:59AM
Notice Text: CRITICAL NOTICE - SAME DAY - OVERAGE ALERT - PHOENIX AREASeptember 8, 2026Due to low line pack in the Phoenix Area, Transwestern is declaring a Same Day Overage Alert in the Phoenix Area for the current gas day, September 8, 2026.Any Operator of a delivery point in the Phoenix Area at which actual quantities exceed scheduled quantities on this Alert Day shall be subject to Alert Day charges in accordance with Section 22.4 of the General Terms and Conditions of Transwestern's FERC Gas Tariff.Based upon current operating conditions, Transwestern anticipates that this low line pack condition will continue at least for the entire current gas day. Transwestern will provide additional information concerning this Alert Day condition as necessary.
NEXUS Gas Transmission (U.S.)

09/07/2026- NEXUS Pipeline Conditions for 09/08/2026

SEV 3/5
Informational

Pre-screen severity 3 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name: NEXUS Gas Transmission, LLC (U.S.)
Subject: NEXUS Pipeline Conditions for 09/08/2026
Notice Type: Capacity Constraint
Critical Notice Description: Critical notice
Notice Status Description: Initiate
Notice Effective Date: 09/08/2026
Notice End Date: 09/09/2026
Posting Date: 09/07/2026
Notice Identifier: 182657
Required Response Indicator Description: No response required

For Gas Day September 8, 2026, Nexus Gas Transmission, LLC (NEXUS) has approved and scheduled nominations at each pipeline segment and meter station up to NEXUS's operational capacity. The following locations have been restricted due to requested nominations exceeding NEXUS's operational capacity:
Restricted Locations
Scheduled and Sealed
Priority % Restricted
Notes
TABS
Belle River
N/A
100%
100%
100%
100%
100%
100%
41%
Due to DTE Posted Outage
Ypsilanti
N/A
100%
100%
100%
100%
100%
100%
38%
Due to DTE Posted Outage
OFO / Imbalance Notice
OFO
---
Customer Specific OFO
No DP - issued 8/20/2026. 2% / 500 Dth/d Tolerance
Imbalances Warnings
Stay Balanced
Systemwide Notes:
Customers are advised that capacity may become available as the nomination and confirmation process continues throughout the day.
Please contact your Operations Account Representative should you have any questions.
Algonquin Gas Transmission

09/07/2026- AGT Pipeline Conditions for 09/08/2026

SEV 3/5
Informational

Pre-screen severity 3 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name: Algonquin Gas Transmission, LLC
Subject: AGT Pipeline Conditions for 09/08/2026
Notice Type: Capacity Constraint
Critical Notice Description: Critical notice
Notice Status Description: Initiate
Notice Effective Date: 09/08/2026
Notice End Date: 09/09/2026
Posting Date: 09/07/2026
Notice Identifier: 182681
Required Response Indicator Description: No response required

For Gas Day September 8, 2026, Algonquin Gas Transmission (AGT) has approved and scheduled nominations at each pipeline segment and meter station up to AGT's operational capacity. The following locations have been restricted due to requested nominations exceeding AGT's operational capacity:
Restricted Locations
Scheduled and Sealed
Priority % Restricted
Notes
Stony Point
100%
100%
100%
100%
100%
100%
100%
Planned Outage
Cromwell
100%
100%
97%
Burrillville
100%
100%
60%
Weymouth
100%
100%
94%
Iroquois Deliveries
100%
100%
Iroquois Receipts
100%
100%
41%
Hanover West
100%
100%
87%
Mendon Receipts
100%
100%
100%
100%
100%
27%
Lincoln Receipts
100%
100%
31%
Lincoln Deliveries
Yes
G System
100%
100%
47%
C System
Yes
Centerville-Transco Receipts (1)
100%
100%
12%
I-8 West to East
Yes
No-Notice Restrictions
---
OFO / Imbalance Notice
System Wide OFO
---
Customer Specific OFO
---
Meter Specific OFO
---
Customer Specific Hourly OFO
---
Imbalances Warnings
Stay Balanced
FERC Order 698
Yes
Systemwide Notes:
(1) AGT has scheduled Transco Centerville receipts to the design meter capacity of 222,526 Dth/d.
AGT requests that customers/point operators on AGT be aware of the impact non-ratable hourly takes from the system may have in causing delivery pressures reaching lower than desired levels.
AGT's system is not designed to sustain delivery pressures above contract levels while making non-ratable/accelerated deliveries above scheduled quantities for more than 6 consecutive hours, to be followed by flows below scheduled quantity for the balance of any 24-hour period. If customers/point operators don't manage hourly takes from the system, 1) delivery pressures will be impacted and /or 2) AGT may be required to impose further restrictions or courses of action in order to maintain the operational integrity of the system.
AGT may be required to issue system specific, meter specific and/or hourly OFO's pursuant to General Terms and Conditions Section 26.7(d) to impose further restrictions in order to maintain the operational integrity of the system.
Customers are advised that capacity may become available as the nomination and confirmation process continues throughout the day.
Please contact your Operations Account Representative should you have any questions.
Iroquois Gas Transmission

Capacity Constraint

SEV 3/5
Informational Until Further Notice

Pre-screen severity 3 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Critical Notice Effective Timely Cycle, Gas Day September 8, 2026, Iroquois nominations are at capacity and sealed from all increases for the following location(s): - Brookfield Interconnect with Algonquin Gas Transmission. In addition, the following capacity has been reduced: - Park and Interruptible receipt nominations at the Brookfield Interconnect are reduced by 100% and Secondary receipt nominations at the Brookfield Interconnect are reduced by 95%. Customers will be advised if further capacity becomes available during the day as volumes are nominated and confirmed. Please contact your account representative or Gas Control for further information. End date 09/09/2026 09:00 CCT
Transwestern Pipeline

[Transwestern Pipeline] [Operational Alert] CRITICAL NOTICE - SAME DAY - OVERAGE ALERT - PHOENIX AREA

SEV 3/5
Informational

Pre-screen severity 3 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Pipeline: Transwestern Pipeline
Notice ID: 120473
Notice Type: Operational Alert
Subject: CRITICAL NOTICE - SAME DAY - OVERAGE ALERT - PHOENIX AREA
Posted: Sep 7 2026 7:34AM
Effective: Sep 7 2026 7:12AM
End Date: Sep 8 2026 8:59AM

Notice Type Description: Operational Alert
Notice Identifier: 120473
Critical Notice Description: Critical notice
Posting Date/Time: Sep 7 2026 7:34AM
Notice Status Description: Initiate
Required Response Indicator Description: No response required
TSP: 7933047
TSP Name: TRANSWESTERN PIPELINE COMPANY, LLC
Subject: CRITICAL NOTICE - SAME DAY - OVERAGE ALERT - PHOENIX AREA
Notice Effective Date/Time: Sep 7 2026 7:12AM
Notice End Date/Time: Sep 8 2026 8:59AM
Notice Text: CRITICAL NOTICE - SAME DAY - OVERAGE ALERT - PHOENIX AREASeptember 7, 2026Due to low line pack in the Phoenix Area, Transwestern is declaring a Same Day Overage Alert in the Phoenix Area for the current gas day, September 7, 2026.Any Operator of a delivery point in the Phoenix Area at which actual quantities exceed scheduled quantities on this Alert Day shall be subject to Alert Day charges in accordance with Section 22.4 of the General Terms and Conditions of Transwestern's FERC Gas Tariff.Based upon current operating conditions, Transwestern anticipates that this low line pack condition will continue at least for the entire current gas day. Transwestern will provide additional information concerning this Alert Day condition as necessary.
NEXUS Gas Transmission (U.S.)

09/06/2026- NEXUS Pipeline Conditions for 09/07/2026

SEV 3/5
Informational

Pre-screen severity 3 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name: NEXUS Gas Transmission, LLC (U.S.)
Subject: NEXUS Pipeline Conditions for 09/07/2026
Notice Type: Capacity Constraint
Critical Notice Description: Critical notice
Notice Status Description: Initiate
Notice Effective Date: 09/07/2026
Notice End Date: 09/08/2026
Posting Date: 09/06/2026
Notice Identifier: 182626
Required Response Indicator Description: No response required

For Gas Day September 7, 2026, Nexus Gas Transmission, LLC (NEXUS) has approved and scheduled nominations at each pipeline segment and meter station up to NEXUS's operational capacity. The following locations have been restricted due to requested nominations exceeding NEXUS's operational capacity:
Restricted Locations
Scheduled and Sealed
Priority % Restricted
Notes
TABS
Belle River
N/A
100%
100%
100%
100%
100%
100%
42%
Due to DTE Posted Outage
Ypsilanti
N/A
100%
100%
100%
100%
100%
100%
37%
Due to DTE Posted Outage
OFO / Imbalance Notice
OFO
---
Customer Specific OFO
No DP - issued 8/20/2026. 2% / 500 Dth/d Tolerance
Imbalances Warnings
Stay Balanced
Systemwide Notes:
Customers are advised that capacity may become available as the nomination and confirmation process continues throughout the day.
Please contact your Operations Account Representative should you have any questions.
Algonquin Gas Transmission

09/06/2026- AGT Pipeline Conditions for 09/07/2026

SEV 3/5
Informational

Pre-screen severity 3 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name: Algonquin Gas Transmission, LLC
Subject: AGT Pipeline Conditions for 09/07/2026
Notice Type: Capacity Constraint
Critical Notice Description: Critical notice
Notice Status Description: Initiate
Notice Effective Date: 09/07/2026
Notice End Date: 09/08/2026
Posting Date: 09/06/2026
Notice Identifier: 182636
Required Response Indicator Description: No response required

For Gas Day September 7, 2026, Algonquin Gas Transmission (AGT) has approved and scheduled nominations at each pipeline segment and meter station up to AGT's operational capacity. The following locations have been restricted due to requested nominations exceeding AGT's operational capacity:
Restricted Locations
Scheduled and Sealed
Priority % Restricted
Notes
Stony Point
100%
100%
55%
Cromwell
100%
100%
52%
Burrillville
100%
100%
28%
Weymouth
100%
100%
99%
Iroquois Deliveries
100%
100%
56%
Iroquois Receipts
100%
100%
42%
Hanover West
100%
100%
22%
Mendon Receipts
100%
100%
100%
100%
82%
Lincoln Receipts
100%
100%
31%
Lincoln Deliveries
Yes
G System
100%
100%
29%
C System
Yes
Centerville-Transco Receipts (1)
100%
100%
I-8 West to East
Yes
No-Notice Restrictions
---
OFO / Imbalance Notice
System Wide OFO
No DS - System Wide issued 9/05/26. 500 Dth / 5% Tolerance
Customer Specific OFO
---
Meter Specific OFO
---
Customer Specific Hourly OFO
---
Imbalances Warnings
---
FERC Order 698
Yes
Systemwide Notes:
(1) AGT has scheduled Transco Centerville receipts to the design meter capacity of 222,526 Dth/d.
AGT requests that customers/point operators on AGT be aware of the impact non-ratable hourly takes from the system may have in causing delivery pressures reaching lower than desired levels.
AGT's system is not designed to sustain delivery pressures above contract levels while making non-ratable/accelerated deliveries above scheduled quantities for more than 6 consecutive hours, to be followed by flows below scheduled quantity for the balance of any 24-hour period. If customers/point operators don't manage hourly takes from the system, 1) delivery pressures will be impacted and /or 2) AGT may be required to impose further restrictions or courses of action in order to maintain the operational integrity of the system.
AGT may be required to issue system specific, meter specific and/or hourly OFO's pursuant to General Terms and Conditions Section 26.7(d) to impose further restrictions in order to maintain the operational integrity of the system.
Customers are advised that capacity may become available as the nomination and confirmation process continues throughout the day.
Please contact your Operations Account Representative should you have any questions.
Transwestern Pipeline

[Transwestern Pipeline] [Operational Alert] CRITICAL NOTICE - SAME DAY - OVERAGE ALERT - PHOENIX AREA

SEV 3/5
Informational

Pre-screen severity 3 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Pipeline: Transwestern Pipeline
Notice ID: 120445
Notice Type: Operational Alert
Subject: CRITICAL NOTICE - SAME DAY - OVERAGE ALERT - PHOENIX AREA
Posted: Sep 6 2026 7:29AM
Effective: Sep 6 2026 7:28AM
End Date: Sep 7 2026 8:59AM

Notice Type Description: Operational Alert
Notice Identifier: 120445
Critical Notice Description: Critical notice
Posting Date/Time: Sep 6 2026 7:29AM
Notice Status Description: Initiate
Required Response Indicator Description: No response required
TSP: 7933047
TSP Name: TRANSWESTERN PIPELINE COMPANY, LLC
Subject: CRITICAL NOTICE - SAME DAY - OVERAGE ALERT - PHOENIX AREA
Notice Effective Date/Time: Sep 6 2026 7:28AM
Notice End Date/Time: Sep 7 2026 8:59AM
Notice Text: CRITICAL NOTICE - SAME DAY - OVERAGE ALERT - PHOENIX AREASeptember 6, 2026Due to low line pack in the Phoenix Area, Transwestern is declaring a Same Day Overage Alert in the Phoenix Area for the current gas day, September 6, 2026.Any Operator of a delivery point in the Phoenix Area at which actual quantities exceed scheduled quantities on this Alert Day shall be subject to Alert Day charges in accordance with Section 22.4 of the General Terms and Conditions of Transwestern's FERC Gas Tariff.Based upon current operating conditions, Transwestern anticipates that this low line pack condition will continue at least for the entire current gas day. Transwestern will provide additional information concerning this Alert Day condition as necessary.
NEXUS Gas Transmission (U.S.)

09/05/2026- NEXUS Pipeline Conditions for 09/06/2026

SEV 3/5
Informational

Pre-screen severity 3 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name: NEXUS Gas Transmission, LLC (U.S.)
Subject: NEXUS Pipeline Conditions for 09/06/2026
Notice Type: Capacity Constraint
Critical Notice Description: Critical notice
Notice Status Description: Initiate
Notice Effective Date: 09/06/2026
Notice End Date: 09/07/2026
Posting Date: 09/05/2026
Notice Identifier: 182597
Required Response Indicator Description: No response required

For Gas Day September 6, 2026, Nexus Gas Transmission, LLC (NEXUS) has approved and scheduled nominations at each pipeline segment and meter station up to NEXUS's operational capacity. The following locations have been restricted due to requested nominations exceeding NEXUS's operational capacity:
Restricted Locations
Scheduled and Sealed
Priority % Restricted
Notes
TABS
Belle River
N/A
100%
100%
100%
100%
100%
100%
40%
Due to DTE Posted Outage
Ypsilanti
N/A
100%
100%
100%
100%
100%
100%
38%
Due to DTE Posted Outage
Salinville
Yes
OFO / Imbalance Notice
OFO
---
Customer Specific OFO
No DP - issued 8/20/2026. 2% / 500 Dth/d Tolerance
Imbalances Warnings
Stay Balanced
Systemwide Notes:
Customers are advised that capacity may become available as the nomination and confirmation process continues throughout the day.
Please contact your Operations Account Representative should you have any questions.
Algonquin Gas Transmission

09/05/2026- AGT Pipeline Conditions for 09/06/2026

SEV 3/5
Informational

Pre-screen severity 3 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name: Algonquin Gas Transmission, LLC
Subject: AGT Pipeline Conditions for 09/06/2026
Notice Type: Capacity Constraint
Critical Notice Description: Critical notice
Notice Status Description: Initiate
Notice Effective Date: 09/06/2026
Notice End Date: 09/07/2026
Posting Date: 09/05/2026
Notice Identifier: 182607
Required Response Indicator Description: No response required

For Gas Day September 6, 2026, Algonquin Gas Transmission (AGT) has approved and scheduled nominations at each pipeline segment and meter station up to AGT's operational capacity. The following locations have been restricted due to requested nominations exceeding AGT's operational capacity:
Restricted Locations
Scheduled and Sealed
Priority % Restricted
Notes
Stony Point
100%
100%
55%
Cromwell
100%
100%
52%
Burrillville
100%
100%
29%
Weymouth
100%
100%
99%
Iroquois Deliveries
100%
100%
56%
Iroquois Receipts
100%
100%
42%
Hanover West
100%
100%
22%
Mendon Receipts
100%
100%
100%
100%
82%
Lincoln Receipts
100%
100%
31%
Lincoln Deliveries
Yes
G System
100%
100%
30%
C System
Yes
Centerville-Transco Receipts (1)
100%
100%
I-8 West to East
Yes
No-Notice Restrictions
---
OFO / Imbalance Notice
System Wide OFO
No DS - System Wide issued 9/05/26. 500 Dth / 5% Tolerance
Customer Specific OFO
---
Meter Specific OFO
---
Customer Specific Hourly OFO
---
Imbalances Warnings
---
FERC Order 698
Yes
Systemwide Notes:
(1) AGT has scheduled Transco Centerville receipts to the design meter capacity of 222,526 Dth/d.
AGT requests that customers/point operators on AGT be aware of the impact non-ratable hourly takes from the system may have in causing delivery pressures reaching lower than desired levels.
AGT's system is not designed to sustain delivery pressures above contract levels while making non-ratable/accelerated deliveries above scheduled quantities for more than 6 consecutive hours, to be followed by flows below scheduled quantity for the balance of any 24-hour period. If customers/point operators don't manage hourly takes from the system, 1) delivery pressures will be impacted and /or 2) AGT may be required to impose further restrictions or courses of action in order to maintain the operational integrity of the system.
AGT may be required to issue system specific, meter specific and/or hourly OFO's pursuant to General Terms and Conditions Section 26.7(d) to impose further restrictions in order to maintain the operational integrity of the system.
Customers are advised that capacity may become available as the nomination and confirmation process continues throughout the day.
Please contact your Operations Account Representative should you have any questions.
El Paso Natural Gas (EPNG)

[OPERATIONAL FLOW ORDER] SOC Declaration - System Wide DRAFT

SEV 3/5
Operational Alert

EPNG has declared a system-wide Strained Operating Condition (SOC) effective September 5, 2026 with duration 'Until Further Notice,' citing linepack at 7,377 MMcf -- a 14 MMcf draw driven by deliveries exceeding scheduled volumes. EPNG has activated Washington Ranch storage withdrawal, suspended imbalance payback and IHSW service, and imposed a 5% imbalance tolerance. No specific capacity volume is quantified in the notice.

EPNG delivery-end SOC tightens westbound delivery schedules toward SoCal Border and Arizona, bullish those basis points; Waha/Permian is neutral as Permian receipts are unaffected and Washington Ranch withdrawal is adding system supply to offset the linepack deficit.
Reroute: Moderate: Transwestern Pipeline (TW) serves overlapping SoCal border and Arizona markets as the primary competing alternative to EPNG, though a simultaneous TW constraint would eliminate California reroute options entirely.
View original notice text
Pipeline: El Paso Natural Gas (EPNG)
Notice Type: OPERATIONAL FLOW ORDER
Subject: SOC Declaration - System Wide DRAFT
Posted: 09/05/2026 9:27:58AM
Effective: 09/05/2026 9:27:58AM
End Date: 09/06/2026 9:00:00AM

TSP/TSP Name:  8001703-EL PASO NATURAL GAS CO. L.L.C. Critical: Y
Notice Type Desc (1):  OPERATIONAL FLOW ORDER Notice Type Desc (2):  OFO
Notice Eff Date/Time:  09/05/2026 9:27:58AM Notice End Date/Time:  09/06/2026 9:00:00am
Post Date/Time:  9/5/2026 9:27:58 AM Notice ID: 629548
Reqrd Rsp:  5 Rsp Date/Time: 
Notice Stat Desc:  INITIATE Prior Notice: 
Subject:  SOC Declaration - System Wide DRAFT
Notice Text:
STRAINED OPERATING CONDITION (SOC) Declaration - System Wide DRAFT
 
EFFECTIVE DATE:  September 5, 2026
IMBALANCE TOLERANCE: 5%
 
DURATION:  Until Further Notice
 
AFFECTED AREAS/LOCATIONS:  System-wide
 
OPERATING CONDITION SUMMARY:  The EPNG system linepack is currently at 7,377 MMcf which is a decrease of 14 MMcf compared to the start of Gas Day September 4, 2026.  The linepack draft is primarily due to deliveries in excess of scheduled volumes.  
 
CUSTOMER ACTION REQUIRED:  Customers are strongly encouraged to review their transport to ensure that their deliveries are in balance with their supplies and to ensure their scheduled supplies are performing as expected.
 
EPNG RESPONSE:
Washington Ranch is on withdrawal.
Imbalance payback off the system, such as Payback (Imbalance Payback from TSP), will be denied due to operational concerns related to maintaining adequate linepack.
IHSW Service will be suspended.
 
REFERENCE INFORMATION:
 
For scheduling questions, please call your scheduling representative at (800) 238-3764.
 
For operational and capacity questions, please call Russ Pyeatt at (719) 520-3729, Dan English at (719) 520-4722, Morgan McCasland at (719) 520-4339, or John Althoff at (719) 667-7750.
 
For media inquiries, please contact media relations at newsroom@kindermorgan.com.
Transwestern Pipeline

[Transwestern Pipeline] [Operational Alert] CRITICAL NOTICE - SAME DAY - OVERAGE ALERT - PHOENIX AREA

SEV 3/5
Informational

Pre-screen severity 3 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Pipeline: Transwestern Pipeline
Notice ID: 120423
Notice Type: Operational Alert
Subject: CRITICAL NOTICE - SAME DAY - OVERAGE ALERT - PHOENIX AREA
Posted: Sep 5 2026 7:54AM
Effective: Sep 5 2026 7:53AM
End Date: Sep 6 2026 8:59AM

Notice Type Description: Operational Alert
Notice Identifier: 120423
Critical Notice Description: Critical notice
Posting Date/Time: Sep 5 2026 7:54AM
Notice Status Description: Initiate
Required Response Indicator Description: No response required
TSP: 7933047
TSP Name: TRANSWESTERN PIPELINE COMPANY, LLC
Subject: CRITICAL NOTICE - SAME DAY - OVERAGE ALERT - PHOENIX AREA
Notice Effective Date/Time: Sep 5 2026 7:53AM
Notice End Date/Time: Sep 6 2026 8:59AM
Notice Text: CRITICAL NOTICE - SAME DAY - OVERAGE ALERT - PHOENIX AREASeptember 5, 2026Due to low line pack in the Phoenix Area, Transwestern is declaring a Same Day Overage Alert in the Phoenix Area for the current gas day, September 5, 2026.Any Operator of a delivery point in the Phoenix Area at which actual quantities exceed scheduled quantities on this Alert Day shall be subject to Alert Day charges in accordance with Section 22.4 of the General Terms and Conditions of Transwestern's FERC Gas Tariff.Based upon current operating conditions, Transwestern anticipates that this low line pack condition will continue at least for the entire current gas day. Transwestern will provide additional information concerning this Alert Day condition as necessary.
Panhandle Eastern Pipe Line

[Panhandle Eastern Pipe Line] [Maintenance] PEPL Sooner Line Outage

SEV 3/5
Maintenance Until Further Notice

Panhandle Eastern posted a Critical maintenance notice on 2026-09-04 for an outage on the PEPL Sooner Line, affecting seven Oklahoma receipt locations including Dover Hennessey Gas Plant, OGT Hennesey, Lincoln Plant, Reeding Plant, Chisholm Plant, DCP Kingfisher, and Taggart Greenhouse. No end date is specified in the notice (nominal end date of 2200-01-01 indicates open-ended duration), meaning the outage timeline is indeterminate. No specific capacity volume is stated, but the affected meters collectively represent meaningful Midcontinent/Oklahoma receipt points on PEPL.

Open-ended Sooner Line outage restricts Oklahoma receipt volumes on PEPL; Panhandle Tx.-Okla. basis was -0.380 on 2026-09-04 (most recently) and averaged -0.414 over the prior five trading days -- watch for further weakening at that hub vs Henry Hub if the outage duration extends, with mild bullish bias for downstream Midwest markets (Indiana, Michigan) as throughput from affected Oklahoma plants is reduced.
Reroute: Moderate: ANR, TGT, and Southern Star Central serve overlapping Midcontinent/Oklahoma supply corridors and may absorb some stranded volumes, though the Sooner Line serves specific Oklahoma gathering plant receipt points that may have limited physical alternatives at the plant level.
View original notice text
Pipeline: Panhandle Eastern Pipe Line
Notice ID: 68394
Notice Type: Maintenance
Subject: PEPL Sooner Line Outage
Posted: 2026-09-04 09:58:00.0
Effective: 2026-09-04 09:58:00.0
End Date: 

Notice ID: 68394
Notice Type: MAI
Critical: Y
Reqrd Rsp Desc: No Response Required
Posting Date/Time: 2026-09-04 09:58:00.0
Subject: PEPL Sooner Line Outage
Notice Effective Date/Time: 2026-09-04 09:58:00.0
Notice End Date/Time: 2200-01-01 00:00:00.0
Location #: Location Name
02384: Dover Hennessey Gas Plant - Mustang
05238: Taggart Greenhouse
12800: OGT Hennesey
41434: Lincoln Plant
41447: Reeding Plant
41433: Chisholm Plant
10632: DCP Kingfisher
Nautilus Pipeline Company

09/03/2026- Nautilus - Unplanned Outage at Enterprise Neptune plant

SEV 3/5
Informational

Pre-screen severity 3 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name: Nautilus Pipeline Company, L.L.C.
Subject: Nautilus - Unplanned Outage at Enterprise Neptune plant
Notice Type: Operational Alert
Critical Notice Description: Critical notice
Notice Status Description: Initiate
Notice Effective Date: 09/03/2026
Notice End Date: 12/02/2026
Posting Date: 09/03/2026
Notice Identifier: 182513
Required Response Indicator Description: No response required

Notice Text:
Nautilus has been informed that the Enterprise Neptune plant is currently shut in due to power outages in the area with an unknown ETA on restart. Shippers will likely see higher than normal system pressures until gas processing can resume.
Updates will be posted as they become available.
Nautilus Pipeline Company

09/03/2026- Nautilus - Unplanned Outage at Enterprise Neptune plant - Update

SEV 3/5
Informational

Pre-screen severity 3 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name: Nautilus Pipeline Company, L.L.C.
Subject: Nautilus - Unplanned Outage at Enterprise Neptune plant - Update
Notice Type: Operational Alert
Critical Notice Description: Critical notice
Notice Status Description: Supersede
Notice Effective Date: 09/03/2026
Notice End Date: 12/02/2026
Posting Date: 09/03/2026
Notice Identifier: 182516
Prior Notice Identifier: 182513
Required Response Indicator Description: No response required

Notice Text:
Nautilus has been informed that the Enterprise Neptune plant has regained commercial power but is still troubleshooting issues in order to return online. Shippers are likely beginning to see higher than normal system pressures on the upstream pipelines.
Updates will be posted as they become available.
NEXUS Gas Transmission (U.S.)

09/04/2026- NEXUS Pipeline Conditions for 9/5/2026

SEV 3/5
Informational

Pre-screen severity 3 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name: NEXUS Gas Transmission, LLC (U.S.)
Subject: NEXUS Pipeline Conditions for 9/5/2026
Notice Type: Capacity Constraint
Critical Notice Description: Critical notice
Notice Status Description: Initiate
Notice Effective Date: 09/05/2026
Notice End Date: 09/06/2026
Posting Date: 09/04/2026
Notice Identifier: 182565
Required Response Indicator Description: No response required

For Gas Day September 5, 2026, Nexus Gas Transmission, LLC (NEXUS) has approved and scheduled nominations at each pipeline segment and meter station up to NEXUS's operational capacity. The following locations have been restricted due to requested nominations exceeding NEXUS's operational capacity:
Restricted Locations
Scheduled and Sealed
Priority % Restricted
Notes
TABS
Belle River
N/A
100%
100%
100%
100%
100%
100%
40%
Due to DTE Posted Outage
Ypsilanti
N/A
100%
100%
100%
100%
100%
100%
38%
Due to DTE Posted Outage
Salinville
Yes
OFO / Imbalance Notice
OFO
---
Customer Specific OFO
No DP - issued 8/20/2026. 2% / 500 Dth/d Tolerance
Imbalances Warnings
Stay Balanced
Systemwide Notes:
Customers are advised that capacity may become available as the nomination and confirmation process continues throughout the day.
Please contact your Operations Account Representative should you have any questions.
ANR Pipeline (TC Energy)

UPDATED: CAPACITY REDUCTION Southwest Area

SEV 3/5
Informational Until Further Notice

Pre-screen severity 3 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name ANR Pipeline Company
TSP 006958581
Notice Type Description: Planned Service Outage

Notice Stat Desc: Supersede

Prior Notice: 26155053

Critical: Y

Reqrd Rsp Desc: No Response Required
Post

Notice Effective

Notice End



Response
Post Date: 09/04/26

09/04/26

09/29/26
Subject: Subject: UPDATED: CAPACITY REDUCTION Southwest Area
Author: Author: T0000106
Notice Text
Since the last posting, ANR has revised the dates for the maintenance in the Southwest Area at the Palo Duro meter station located in Wheeler County, Texas. As a result, capacity will be reduced as follows:

9/21 – 9/28 (previously 9/13 – 9/18) Palo Duro (LOC #438677): 92 MMcf/d (leaving 0 MMcf/d)

ANR anticipates this posting may result in Firm Primary, Firm Secondary and Interruptible curtailments. Estimated impact to Firm Primary as follows:

100% - Based on the Current Net Shipper Nominations

           100% - Based on the Current Contracted MDQ

           

Any reservation charge credits (RCCs) will be determined per the process set forth in the General Terms and Conditions, Section 6.36 of ANR’s FERC Gas Tariff (“Tariff”). However, ANR will only issue RCCs if ANR is unable to schedule or deliver primary firm nominated capacity as a result of the outage. In the event RCCs are issued as set forth in the Tariff, shippers will receive RCCs based on its 7-day Non-Force Majeure Average Usage Quantity, as defined in Section 6.36.2 of ANR’s Tariff, less any scheduled quantities on the contract. 

Please direct any questions to your Account Coordinator, Customer Service Representative, or the Nominations and Scheduling hotline @ 800-827-5267.
ANR Pipeline (TC Energy)

UPDATED: CAPACITY REDUCTION Southwest Area

SEV 3/5
Informational Until Further Notice

Pre-screen severity 3 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name ANR Pipeline Company
TSP 006958581
Notice Type Description: Planned Service Outage

Notice Stat Desc: Supersede

Prior Notice: 26155054

Critical: Y

Reqrd Rsp Desc: No Response Required
Post

Notice Effective

Notice End



Response
Post Date: 09/04/26

09/04/26

09/29/26
Subject: Subject: UPDATED: CAPACITY REDUCTION Southwest Area
Author: Author: T0000106
Notice Text
Since the last posting, ANR has revised the dates for the maintenance in the Southwest Area at the Wheeler Hidetown meter station located in Wheeler County, Texas. As a result, capacity will be reduced as follows:

9/21 – 9/28 (previously 9/13 – 9/18) Wheeler Hidetown (LOC #523099): 480 MMcf/d (leaving 0 MMcf/d)

ANR anticipates this posting may result in Firm Primary, Firm Secondary and Interruptible curtailments. Estimated impact to Firm Primary as follows:

100% - Based on the Current Net Shipper Nominations

           100% - Based on the Current Contracted MDQ

           

Any reservation charge credits (RCCs) will be determined per the process set forth in the General Terms and Conditions, Section 6.36 of ANR’s FERC Gas Tariff (“Tariff”). However, ANR will only issue RCCs if ANR is unable to schedule or deliver primary firm nominated capacity as a result of the outage. In the event RCCs are issued as set forth in the Tariff, shippers will receive RCCs based on its 7-day Non-Force Majeure Average Usage Quantity, as defined in Section 6.36.2 of ANR’s Tariff, less any scheduled quantities on the contract. 

Please direct any questions to your Account Coordinator, Customer Service Representative, or the Nominations and Scheduling hotline @ 800-827-5267.
ANR Pipeline (TC Energy)

UPDATED: CAPACITY REDUCTION Michigan Leg North – Bridgman Northbound

SEV 3/5
Informational Until Further Notice

Pre-screen severity 3 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name ANR Pipeline Company
TSP 006958581
Notice Type Description: Planned Service Outage

Notice Stat Desc: Supersede

Prior Notice: 26202031

Critical: Y

Reqrd Rsp Desc: No Response Required
Post

Notice Effective

Notice End



Response
Post Date: 09/04/26

09/04/26

11/06/26
Subject: Subject: UPDATED: CAPACITY REDUCTION Michigan Leg North – Bridgman Northbound
Author: Author: T0001375
Notice Text
Since the last posting, ANR has revised the dates and impacted locations for the Hamilton compressor station maintenance in the Michigan Leg North area located in Allegan County, Michigan. ANR anticipates this posting may result in Firm Primary, Firm Secondary and Interruptible curtailments. As a result, capacity will be reduced as follows:

9/21 – 11/5 (previously 9/14 – 10/13) Bridgman Northbound (LOC #FPBRGMNB): 728 MMcf/d (leaving 894 MMcf/d)

Estimated impact to Firm Primary as follows:

               0% - Based on the Current Net Shipper Nominations

              38% - Based on the Current Contracted MDQ

9/21 – 11/5 Rabbit River (LOC #523093): 83 MMcf/d (leaving 0 MMcf/d)

Estimated impact to Firm Primary as follows:

               100% - Based on the Current Net Shipper Nominations

              100% - Based on the Current Contracted MDQ

Any reservation charge credits (RCCs) will be determined per the process set forth in the General Terms and Conditions, Section 6.36 of ANR’s FERC Gas Tariff (“Tariff”). However, ANR will only issue RCCs if ANR is unable to schedule or deliver primary firm nominated capacity as a result of the outage. In the event RCCs are issued as set forth in the Tariff, shippers will receive RCCs based on its 7-day Non-Force Majeure Average Usage Quantity, as defined in Section 6.36.2 of ANR’s Tariff, less any scheduled quantities on the contract.
Transwestern Pipeline

[Transwestern Pipeline] [Operational Alert] CRITICAL NOTICE - SAME DAY - OVERAGE ALERT - PHOENIX AREA

SEV 3/5
Informational

Pre-screen severity 3 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Pipeline: Transwestern Pipeline
Notice ID: 120403
Notice Type: Operational Alert
Subject: CRITICAL NOTICE - SAME DAY - OVERAGE ALERT - PHOENIX AREA
Posted: Sep 4 2026 7:39AM
Effective: Sep 4 2026 7:37AM
End Date: Sep 5 2026 8:59AM

Notice Type Description: Operational Alert
Notice Identifier: 120403
Critical Notice Description: Critical notice
Posting Date/Time: Sep 4 2026 7:39AM
Notice Status Description: Initiate
Required Response Indicator Description: No response required
TSP: 7933047
TSP Name: TRANSWESTERN PIPELINE COMPANY, LLC
Subject: CRITICAL NOTICE - SAME DAY - OVERAGE ALERT - PHOENIX AREA
Notice Effective Date/Time: Sep 4 2026 7:37AM
Notice End Date/Time: Sep 5 2026 8:59AM
Notice Text: CRITICAL NOTICE - SAME DAY - OVERAGE ALERT - PHOENIX AREASeptember 4, 2026Due to low line pack in the Phoenix Area, Transwestern is declaring a Same Day Overage Alert in the Phoenix Area for the current gas day, September 4, 2026.Any Operator of a delivery point in the Phoenix Area at which actual quantities exceed scheduled quantities on this Alert Day shall be subject to Alert Day charges in accordance with Section 22.4 of the General Terms and Conditions of Transwestern's FERC Gas Tariff.Based upon current operating conditions, Transwestern anticipates that this low line pack condition will continue at least for the entire current gas day. Transwestern will provide additional information concerningthis Alert Day condition as necessary.
Columbia Gas Transmission (TCO)

OFO – Receipt Points in Market Areas 26, 30, 35, 41, 42, Effective September 5, 2026

SEV 3/5
Operational Alert Until Further Notice

TCO has issued a formal OFO effective Gas Day September 5, 2026, requiring shippers with receipts in Market Areas 26, 30, 35, 41, and 42 to align physical receipts at or below scheduled quantities. The OFO is driven by mild weather, reduced market demand, and elevated storage and linepack levels causing excess Appalachian production to threaten system integrity. The order runs until further notice, with penalties up to three times the Columbia Gas Appalachia spot price for non-compliant shippers.

TCO receipt-side OFO across five Appalachian market areas caps physical injections and forces upstream producers to curtail flows into the basin, adding bearish pressure to Columbia Gas Appalachia basis, which was already at -1.265 vs Henry Hub on 2026-09-03 (five-day average -1.122); no volume cap is stated, but the open-ended duration and system-wide geographic scope across MAs 26, 30, 35, 41, and 42 keeps downward pressure on Dominion South and TETCO M2 as excess supply is trapped in the Appalachian basin.
Reroute: Limited: the OFO restricts the receipt side of TCO's Appalachian network; affected producers have few near-term alternatives as TETCO (monitored) and TCO are the two dominant Appalachian takeaway pipes, and any TCO receipt constraint that backs gas up in the basin similarly pressures available TETCO capacity at M2 points. Some modest diversion to Rover or REX Zone 3 is possible but unlikely to absorb material volumes given the broad market-area scope of the OFO.
View original notice text
TSP Name Columbia Gas Transmission, LLC
TSP 054748041
Notice Type Description: Operational Flow Order

Notice Stat Desc: Initiate

Prior Notice: 

Critical: Y

Reqrd Rsp Desc: No Response Required
Post

Notice Effective

Notice End



Response
Post Date: 09/04/26

09/04/26

10/04/26
Subject: Subject: OFO – Receipt Points in Market Areas 26, 30, 35, 41, 42, Effective September 5, 2026
Author: Author: Tyler King
Notice Text
Pursuant to the provisions of Section 17 of the General Terms and Conditions of its FERC Gas Tariff, Columbia Gas Transmission, LLC (TCO) is issuing an Operational Flow Order ("OFO") to Shippers under all transportation rate schedules with receipts in Market Areas 26, 30, 35, 41, and 42 to protect the operational integrity of TCO’s system and its ability to meet its firm service obligations.  

 

As explained in Pre OFO (Notice ID 26205016), due to mild weather forecasts, anticipated lower market demand, higher storage and line pack levels, and the level of production received in Market Areas 26, 30, 35, 41, and 42, physical receipts must be equal to or less than scheduled receipts in order to maintain system integrity and provide reliable firm service. Consequently, TCO cannot allow excess receipts at any receipt point in these Market Areas.

 

Therefore, TCO is issuing the following Operational Flow Order (OFO): 

  

1. The Time and Date of Issuance of this OFO is Friday, September 4, 2026, at 8:05 AM ET. 

 

2. The OFO will become effective for Gas Day Saturday, September 5, 2026. 

 

3. This OFO will continue in duration until TCO issues further notice of termination of this OFO. 

 

4. The Shippers impacted by this OFO are those scheduling receipts of gas in Market Areas 26, 30, 35, 41, and 42 whose physical receipts are not less than or equal to their scheduled receipts during a Gas Day.  

 

5. Pursuant to the OFO, the following actions must be taken:  

During the period this OFO is in effect, impacted shippers must align scheduled quantities with physical quantities in Market Areas 26, 30, 35, 41, and 42, which may require communication with upstream operators. Shippers must remain in balance at the start of, and throughout, each Gas Day, beginning Saturday, September 5, 2026, and continuing until further notice. Receipt points must be balanced such that actual receipts into Market Areas 26, 30, 35, 41, and 42 must be less than or equal to the scheduled receipt quantities into these areas unless otherwise mutually agreed on a nondiscriminatory basis.  

 

6. The justification for issuing the OFO is as set forth above. 

 

7. Additional information: Shippers who do not comply will be subject to penalties in accordance with Section 19.3 of TCO’s FERC Gas Tariff. Shippers are encouraged to stay coordinated with upstream suppliers regarding changes in physical flow for the duration of the OFO. 

 

If a penalty is assessed, the penalty will be based on all quantities in aggregate in violation of the OFO in excess of a tolerance of 5% of scheduled receipt quantities or 5,000 Dth whichever is higher. This tolerance will be in effect during the OFO unless revised through an update to this notice.   Penalties will be based on the shipper’s prorated share of the total excess quantities above the tolerance at the receipt point for that day at the higher of: (i) a price per Dth equal to three times the midpoint of the range of prices reported for "Columbia Gas, Appalachia" as published in Platts Gas Daily price survey for the days on which the OFO is issued, or (ii) a price per Dth equal to 150 percent of the highest midpoint posting for either: Mich Con City-gate, Transco, Zone 6 Non-N.Y., or Texas Eastern, M-2 Receipts as published in Platts Gas Daily price survey for the days on which the OFO is issued. Penalties under Section 19.3 (ii) will only be assessed on days in which the daily spot price of gas exceeds three times the midpoint of the range of prices reported for "Columbia Gas, Appalachia."  

 

Please contact your Customer Services Representative with any questions.
Texas Eastern Transmission (TETCO)

09/03/2026- TE Operational Flow Order -- EFF 9/5

SEV 3/5
Informational

Pre-screen severity 3 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name: Texas Eastern Transmission, LP
Subject: TE Operational Flow Order -- EFF 9/5
Notice Type: Operational Flow Order
Critical Notice Description: Critical notice
Notice Status Description: Initiate
Notice Effective Date: 09/05/2026
Notice End Date: 09/08/2026
Posting Date: 09/03/2026
Notice Identifier: 182506
Required Response Indicator Description: No response required

Zone
Gas Day September 2 - September 3
Gas Day September 4
Gas Day September 5 - September 7
Gas Day September 8 and until further notice
M1-24"
No Action Alert or OFO
No Action Alert or OFO
OFO In Effect: No Due Shipper 5% / 500
No Action Alert or OFO
M1-30"
No Action Alert or OFO
No Action Alert or OFO
OFO In Effect: No Due Shipper 5% / 500
No Action Alert or OFO
M2-24"
Action Alert In Effect: No Due Pipe 10% / 500
No Action Alert or OFO
OFO In Effect: No Due Shipper 5% / 500
No Action Alert or OFO
M2-30"
Action Alert In Effect: No Due Pipe 10% / 500
No Action Alert or OFO
OFO In Effect: No Due Shipper 5% / 500
No Action Alert or OFO
Action Alert In Effect: No Due Pipe 10% / 500
No Action Alert or OFO
OFO In Effect: No Due Shipper 5% / 500
No Action Alert or OFO
ETX
No Action Alert or OFO
No Action Alert or OFO
No Action Alert or OFO
No Action Alert or OFO
STX
No Action Alert or OFO
No Action Alert or OFO
No Action Alert or OFO
No Action Alert or OFO
WLA
No Action Alert or OFO
No Action Alert or OFO
No Action Alert or OFO
No Action Alert or OFO
ELA
No Action Alert or OFO
No Action Alert or OFO
No Action Alert or OFO
No Action Alert or OFO
Customer Specific
No OFO*
No OFO*
No OFO*
No OFO*
Texas Eastern Transmission (TETCO)

09/03/2026- TE Pipeline Conditions for 09/04/2026

SEV 3/5
Informational

Pre-screen severity 3 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name: Texas Eastern Transmission, LP
Subject: TE Pipeline Conditions for 09/04/2026
Notice Type: Capacity Constraint
Critical Notice Description: Critical notice
Notice Status Description: Initiate
Notice Effective Date: 09/04/2026
Notice End Date: 09/05/2026
Posting Date: 09/03/2026
Notice Identifier: 182528
Required Response Indicator Description: No response required

For Gas Day September 4, 2026, Texas Eastern (TE) has approved and scheduled nominations at each pipeline segment and meter station up to TE's operational capacity. The following locations have been restricted due to requested nominations exceeding TE's operational capacity:
Restricted Locations
Scheduled and Sealed
Priority % Restricted
Notes
TABS
North of Berne
Meter 75919 Deliveries
N/A
100%
100%
87%
Rec from AGT & Del West of Lambertville
100%
100%
100%
TE/AGT Lease
Yes
To Lease Capacity
Nexus/TE Leased Meters
Yes
To Lease Capacity
30" South of Berne
Berne - Southbound
N/A
100%
100%
Danville - Southbound
N/A
100%
100%
Tompkinsville - Southbound
N/A
100%
100%
Barton - Southbound
N/A
100%
100%
24"
Sarahsville - Southbound
N/A
100%
100%
100%
100%
Unplanned Outage
Five Points - Southbound
N/A
100%
71%
Unplanned Outage
Lebanon
N/A
100%
59%
Unplanned Outage
Lebanon Lateral
N/A
100%
94%
Batesville - Southbound
N/A
100%
40%
Meter 74215 Deliveries
Yes
Access Area
Union Church - Southbound
N/A
100%
27%
New Roads South - Southbound
N/A
100%
95%
White Castle - Southbound
N/A
100%
94%
Longview - Northbound
N/A
100%
34%
Huntsville - Northbound
N/A
100%
Speaks - Southbound
N/A
100%
81%
Angleton West - Northbound
N/A
100%
49%
Vidor East - Northbound
Yes
Gillis - Northbound
N/A
100%
54%
TABS Pool Restrictions - Tolerances
ETX
STX
WLA
ELA
M1-24"
M1-30"
M2-24"
M2-30"
TABS Pool - Length
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
TABS Pool - Short
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
No-Notice Restrictions
OFO / Imbalance Notice
OFO
---
Action Alert
---
Customer Specific OFO
---
Imbalance Warnings
Stay Balanced - Access Area, M1-24, M1-30, M2-24, M2-30 and M3.
FERC Order 698
M2-24, M2-30 and M3
Gas Quality:
The gas quality entering TE's system from meters 73915, 73713, 73733, and 73714 continues to improve. As a result, the prior notification regarding partial flow reductions beginning September 9, 2026, has been rescinded for these meters. TE will continue to monitor gas entering its system to ensure compliance with TE's gas quality standards in its GT&C. If continued and sustained improvement is not demonstrated, meter operators may be subject to future flow reductions.
Due to gas quality issues, meter 76609 has been shut in and physical receipts at the meter will be unavailable until further notice.  Beginning during the Timely cycle for Gas Day December 6, 2025, and until further notice, TE will restrict receipt nominations at Meter 76609 to -0- Dth/d.
Systemwide Notes:
Shippers in all Texas Eastern's Access Area Zones and Market Area Zones M1-30, M2-30 and M3 are required to coordinate any imbalance payback through TE's account representative and actual payback quantities may be limited depending on system operations and conditions. If customers do not adhere to imbalance requirements stated above, TE will utilize any provision of its tariff to ensure system integrity including the issuance of customer specific or system wide OFOs.
Please contact your Operations Account Representative should you have any questions.
East Tennessee Natural Gas

09/03/2026- ETNG Pipeline Conditions for 9/4/2026

SEV 3/5
Informational

Pre-screen severity 3 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name: East Tennessee Natural Gas, LLC
Subject: ETNG Pipeline Conditions for 9/4/2026
Notice Type: Capacity Constraint
Critical Notice Description: Critical notice
Notice Status Description: Initiate
Notice Effective Date: 09/04/2026
Notice End Date: 09/05/2026
Posting Date: 09/03/2026
Notice Identifier: 182519
Required Response Indicator Description: No response required

For Gas Day September 4, 2026, East Tennessee Natural Gas (ETNG) has approved and scheduled nominations at each pipeline segment and meter station up to ETNG's operational capacity. The following locations have been restricted due to requested nominations exceeding ETNG's operational capacity:
Restricted Locations
Scheduled and Sealed
Priority % Restricted
Notes
Deliveries To Texas Eastern
100%
100%
Topside South
100%
100%
80%
Fordtown West - Westbound
Yes
Flatwoods East - Westbound
Yes
OFO / Imbalance Notice
OFO
---
Customer Specific OFO
---
Hourly Customer Specific OFO
---
Action Alert
---
Imbalances Warnings
Stay Balanced
Systemwide Notes:
ETNG requires any imbalance payback be coordinated through your Operations Account Representative.
If necessary, ETNG will utilize any provision of its tariff to ensure system integrity including the issuance of customer specific or system wide OFOs.
Effective October 1, 2025, MR 59200 - SNG Whitfield will be restricted to 0 Dth / d until further notice due to SNG pressures being lower than ETNG's typical operating pressure. Also, effective October 1, 2025, MR 59311 - SNG Bradley will be limited to its meter capacity of 31,000 Dth/d.
Customers are advised that capacity may become available as the nomination and confirmation process continues throughout the day.
Please contact your Operations Account Representative should you have any questions.
Algonquin Gas Transmission

09/03/2026- AGT Operational Flow Order -- EFF 9/5

SEV 3/5
Informational

Pre-screen severity 3 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name: Algonquin Gas Transmission, LLC
Subject: AGT Operational Flow Order -- EFF 9/5
Notice Type: Operational Flow Order
Critical Notice Description: Critical notice
Notice Status Description: Initiate
Notice Effective Date: 09/05/2026
Notice End Date: 12/02/2026
Posting Date: 09/03/2026
Notice Identifier: 182514
Required Response Indicator Description: No response required

Operational Area
Gas Day September 3 - September 4
Gas Day September 5 - September 7
Gas Day September 8 and until further notice
System Wide - All Customers
No OFO*
OFO In Effect: No DS 5% / 500
No Due Pipe Imbalance Warning in Effect
Customer Specific
No OFO*
No OFO*
No OFO*
Hourly Customer Specific
No OFO*
No OFO*
No OFO*
ANR Pipeline (TC Energy)

UPDATED: CAPACITY REDUCTION Michigan Leg South - St. John Eastbound

SEV 3/5
Informational Until Further Notice

Pre-screen severity 3 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name ANR Pipeline Company
TSP 006958581
Notice Type Description: Maintenance

Notice Stat Desc: Supersede

Prior Notice: 26125012

Critical: Y

Reqrd Rsp Desc: No Response Required
Post

Notice Effective

Notice End



Response
Post Date: 09/03/26

09/03/26

09/10/26
Subject: Subject: UPDATED: CAPACITY REDUCTION Michigan Leg South - St. John Eastbound
Author: Author: T0000106
Notice Text
Since the last posting, ANR has extended pipeline maintenance in the Michigan Leg South area. As a result, capacity will be reduced as follows:

9/1 – 9/9 (previously 9/3) St. John Eastbound (LOC #FPSTJNEB): 750 MMcf/d (leaving 575 MMcf/d)

 

ANR anticipates this posting may result in Firm Primary, Firm Secondary and Interruptible curtailments. Estimated impact to Firm Primary as follows:

      

25% - Based on the Current Net Shipper Nominations

59% - Based on the Current Contracted MDQ

Any reservation charge credits (RCCs) will be determined per the process set forth in the General Terms and Conditions, Section 6.36 of ANR’s FERC Gas Tariff (“Tariff”). However, ANR will only issue RCCs if ANR is unable to schedule or deliver primary firm nominated capacity as a result of the outage. In the event RCCs are issued as set forth in the Tariff, shippers will receive RCCs based on its 7-day Non-Force Majeure Average Usage Quantity, as defined in Section 6.36.2 of ANR’s Tariff, less any scheduled quantities on the contract. 

 

Please direct any questions to your Account Coordinator, Customer Service Representative, or the Nominations and Scheduling hotline @ 800-827-5267
Transwestern Pipeline

[Transwestern Pipeline] [Operational Alert] CRITICAL NOTICE - SAME DAY - UNDERAGE ALERT - PHOENIX AREA

SEV 3/5
Informational

Pre-screen severity 3 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Pipeline: Transwestern Pipeline
Notice ID: 120380
Notice Type: Operational Alert
Subject: CRITICAL NOTICE - SAME DAY - UNDERAGE ALERT - PHOENIX AREA
Posted: Sep 3 2026 8:00AM
Effective: Sep 3 2026 8:00AM
End Date: Sep 4 2026 8:59AM

Notice Type Description: Operational Alert
Notice Identifier: 120380
Critical Notice Description: Critical notice
Posting Date/Time: Sep 3 2026 8:00AM
Notice Status Description: Initiate
Required Response Indicator Description: No response required
TSP: 7933047
TSP Name: TRANSWESTERN PIPELINE COMPANY, LLC
Subject: CRITICAL NOTICE - SAME DAY - UNDERAGE ALERT - PHOENIX AREA
Notice Effective Date/Time: Sep 3 2026 8:00AM
Notice End Date/Time: Sep 4 2026 8:59AM
Notice Text: CRITICAL NOTICE - SAME DAY - UNDERAGE ALERT - PHOENIX AREASeptember 3, 2026Due to high line pack in the Phoenix Area, Transwestern is declaring a Same Day Underage Alert for the Phoenix Area for gas day, September 3, 2026. Any Operator of a delivery point in the Phoenix Area at which actual quantities are less than scheduled quantities on this Alert Day shall be subject to Alert Day charges in accordance with Section 22.4 of the General Terms and Conditions of Transwestern's FERC Gas Tariff.Based upon current operating conditions, Transwestern anticipates that this high line pack condition will continue at least for the entire gas day. Transwestern will provide additional information concerning this Alert Day condition as necessary.Please contact Gas Control or your marketing representative with any questions
Texas Eastern Transmission (TETCO)

09/02/2026- TE Pipeline Conditions for 9/3/2026

SEV 3/5
Informational

Pre-screen severity 3 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name: Texas Eastern Transmission, LP
Subject: TE Pipeline Conditions for 9/3/2026
Notice Type: Capacity Constraint
Critical Notice Description: Critical notice
Notice Status Description: Initiate
Notice Effective Date: 09/03/2026
Notice End Date: 09/04/2026
Posting Date: 09/02/2026
Notice Identifier: 182496
Required Response Indicator Description: No response required

For Gas Day September 3, 2026, Texas Eastern (TE) has approved and scheduled nominations at each pipeline segment and meter station up to TE's operational capacity. The following locations have been restricted due to requested nominations exceeding TE's operational capacity:
Restricted Locations
Scheduled and Sealed
Priority % Restricted
Notes
TABS
North of Berne
Meter 75919 Deliveries
N/A
100%
100%
87%
Rec from AGT & Del West of Lambertville
100%
100%
100%
TE/AGT Lease
Yes
To Lease Capacity
Nexus/TE Leased Meters
Yes
To Lease Capacity
30" South of Berne
Berne - Southbound
N/A
100%
100%
Danville - Southbound
N/A
100%
100%
Tompkinsville - Southbound
N/A
100%
100%
Barton - Southbound
N/A
100%
100%
24"
Sarahsville - Southbound
N/A
100%
100%
100%
100%
100%
Unplanned Outage
Five Points - Southbound
N/A
100%
30%
Unplanned Outage
Lebanon
N/A
100%
23%
Unplanned Outage
Lebanon Lateral
N/A
100%
78%
Batesville - Southbound
N/A
100%
63%
Meter 74215 Deliveries
Yes
Access Area
Union Church - Southbound
N/A
100%
23%
New Roads South - Southbound
N/A
100%
95%
White Castle - Southbound
N/A
100%
94%
Longview - Northbound
N/A
100%
31%
Huntsville - Northbound
N/A
55%
Speaks - Southbound
N/A
100%
82%
Angleton West - Northbound
N/A
100%
45%
Vidor East - Northbound
Yes
Gillis - Northbound
N/A
100%
52%
TABS Pool Restrictions - Tolerances
ETX
STX
WLA
ELA
M1-24"
M1-30"
M2-24"
M2-30"
TABS Pool - Length
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
TABS Pool - Short
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
No-Notice Restrictions
OFO / Imbalance Notice
OFO
---
Action Alert
No DP - M2-24, M2-30 and M3 issued 9/2/2026. 10% / 500 Dth/d Tolerance
Customer Specific OFO
---
Imbalance Warnings
Stay Balanced - Access Area, M1-24 and M1-30.
FERC Order 698
M2-24, M2-30 and M3
Gas Quality:
Due to ongoing gas quality issues at meters 73915, 73713,73733 and 73714, TE will require a partial reduction of flow beginning as soon as September 9, 2026, if gas quality issues are not corrected by that date. These meter operators will remain at a reduced flow, and will be subject to further reductions, until the gas entering TE's system is compliant with TE's gas quality standards in its GT&C. The upstream point operators are required to ensure nominations are commensurate with the physical flow, or non-performance confirmation reductions may be required.
Due to gas quality issues, meter 76609 has been shut in and physical receipts at the meter will be unavailable until further notice.  Beginning during the Timely cycle for Gas Day December 6, 2025, and until further notice, TE will restrict receipt nominations at Meter 76609 to -0- Dth/d.
Systemwide Notes:
Shippers in all Texas Eastern's Access Area Zones and Market Area Zones M1-30, M2-30 and M3 are required to coordinate any imbalance payback through TE's account representative and actual payback quantities may be limited depending on system operations and conditions. If customers do not adhere to imbalance requirements stated above, TE will utilize any provision of its tariff to ensure system integrity including the issuance of customer specific or system wide OFOs.
Please contact your Operations Account Representative should you have any questions.
NEXUS Gas Transmission (U.S.)

09/02/2026- NEXUS Pipeline Conditions for 09/03/2026

SEV 3/5
Informational

Pre-screen severity 3 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name: NEXUS Gas Transmission, LLC (U.S.)
Subject: NEXUS Pipeline Conditions for 09/03/2026
Notice Type: Capacity Constraint
Critical Notice Description: Critical notice
Notice Status Description: Initiate
Notice Effective Date: 09/03/2026
Notice End Date: 09/04/2026
Posting Date: 09/02/2026
Notice Identifier: 182472
Required Response Indicator Description: No response required

For Gas Day September 3, 2026, Nexus Gas Transmission, LLC (NEXUS) has approved and scheduled nominations at each pipeline segment and meter station up to NEXUS's operational capacity. The following locations have been restricted due to requested nominations exceeding NEXUS's operational capacity:
Restricted Locations
Scheduled and Sealed
Priority % Restricted
Notes
TABS
Belle River
N/A
100%
100%
100%
100%
100%
100%
42%
Due to DTE Posted Outage
Ypsilanti
N/A
100%
100%
100%
100%
100%
100%
38%
Due to DTE Posted Outage
Salinville
Yes
OFO / Imbalance Notice
OFO
---
Customer Specific OFO
No DP - issued 8/20/2026. 2% / 500 Dth/d Tolerance
Imbalances Warnings
Stay Balanced
Gas Quality:
NEXUS has been informed by TETCO of ongoing gas quality issues at meters N4714, N4733, N4915. TE/NEXUS will require a partial reduction of flow beginning as soon as September 9, 2026, if gas quality issues are not corrected by that date. These meter operators will remain at a reduced flow, and will be subject to further reductions, until the gas entering TE's system is compliant with TE's gas quality standards in its GT&C. The upstream point operators are required to ensure nominations are commensurate with the physical flow, or non-performance confirmation reductions may be required.
Systemwide Notes:
Customers are advised that capacity may become available as the nomination and confirmation process continues throughout the day.
Please contact your Operations Account Representative should you have any questions.
East Tennessee Natural Gas

09/02/2026- ETNG Pipeline Conditions for 09/03/2026

SEV 3/5
Informational

Pre-screen severity 3 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name: East Tennessee Natural Gas, LLC
Subject: ETNG Pipeline Conditions for 09/03/2026
Notice Type: Capacity Constraint
Critical Notice Description: Critical notice
Notice Status Description: Initiate
Notice Effective Date: 09/03/2026
Notice End Date: 09/04/2026
Posting Date: 09/02/2026
Notice Identifier: 182479
Required Response Indicator Description: No response required

For Gas Day September 3, 2026, East Tennessee Natural Gas (ETNG) has approved and scheduled nominations at each pipeline segment and meter station up to ETNG's operational capacity. The following locations have been restricted due to requested nominations exceeding ETNG's operational capacity:
Restricted Locations
Scheduled and Sealed
Priority % Restricted
Notes
Deliveries To Texas Eastern
100%
100%
Topside South
100%
100%
88%
Boyds Creek - Westbound
100%
100%
96%
Fordtown West - Westbound
Yes
Flatwoods East - Westbound
Yes
OFO / Imbalance Notice
OFO
---
Customer Specific OFO
---
Hourly Customer Specific OFO
---
Action Alert
---
Imbalances Warnings
Stay Balanced
Systemwide Notes:
ETNG requires any imbalance payback be coordinated through your Operations Account Representative.
If necessary, ETNG will utilize any provision of its tariff to ensure system integrity including the issuance of customer specific or system wide OFOs.
Effective October 1, 2025, MR 59200 - SNG Whitfield will be restricted to 0 Dth / d until further notice due to SNG pressures being lower than ETNG's typical operating pressure. Also, effective October 1, 2025, MR 59311 - SNG Bradley will be limited to its meter capacity of 31,000 Dth/d.
Customers are advised that capacity may become available as the nomination and confirmation process continues throughout the day.
Please contact your Operations Account Representative should you have any questions.
Algonquin Gas Transmission

09/02/2026- AGT Pipeline Conditions for 09/03/2026

SEV 3/5
Informational

Pre-screen severity 3 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name: Algonquin Gas Transmission, LLC
Subject: AGT Pipeline Conditions for 09/03/2026
Notice Type: Capacity Constraint
Critical Notice Description: Critical notice
Notice Status Description: Initiate
Notice Effective Date: 09/03/2026
Notice End Date: 09/04/2026
Posting Date: 09/02/2026
Notice Identifier: 182497
Required Response Indicator Description: No response required

For Gas Day September 3, 2026, Algonquin Gas Transmission (AGT) has approved and scheduled nominations at each pipeline segment and meter station up to AGT's operational capacity. The following locations have been restricted due to requested nominations exceeding AGT's operational capacity:
Restricted Locations
Scheduled and Sealed
Priority % Restricted
Notes
Stony Point
100%
100%
58%
Cromwell
100%
100%
56%
Burrillville
100%
100%
34%
Weymouth
100%
100%
99%
Iroquois Deliveries
100%
100%
79%
Iroquois Receipts
100%
100%
50%
Hanover West
100%
100%
21%
Mendon Receipts
100%
100%
100%
100%
81%
Lincoln Receipts
100%
100%
33%
Lincoln Deliveries
Yes
G System
100%
100%
40%
C System
Yes
Centerville-Transco Receipts (1)
100%
100%
14%
I-8 West to East
Yes
No-Notice Restrictions
---
OFO / Imbalance Notice
System Wide OFO
---
Customer Specific OFO
---
Meter Specific OFO
---
Customer Specific Hourly OFO
---
Imbalances Warnings
Stay Balanced
FERC Order 698
Yes
Systemwide Notes:
(1) AGT has scheduled Transco Centerville receipts to the design meter capacity of 222,526 Dth/d.
AGT requests that customers/point operators on AGT be aware of the impact non-ratable hourly takes from the system may have in causing delivery pressures reaching lower than desired levels.
AGT's system is not designed to sustain delivery pressures above contract levels while making non-ratable/accelerated deliveries above scheduled quantities for more than 6 consecutive hours, to be followed by flows below scheduled quantity for the balance of any 24-hour period. If customers/point operators don't manage hourly takes from the system, 1) delivery pressures will be impacted and /or 2) AGT may be required to impose further restrictions or courses of action in order to maintain the operational integrity of the system.
AGT may be required to issue system specific, meter specific and/or hourly OFO's pursuant to General Terms and Conditions Section 26.7(d) to impose further restrictions in order to maintain the operational integrity of the system.
Customers are advised that capacity may become available as the nomination and confirmation process continues throughout the day.
Please contact your Operations Account Representative should you have any questions.
Columbia Gulf Transmission (CGT)

Alexandria Compressor Station Maintenance (AlexSEG), September 9, 2026

SEV 3/5
Informational Until Further Notice

Pre-screen severity 3 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name Columbia Gulf Transmission, LLC
TSP 007854581
Notice Type Description: Maintenance

Notice Stat Desc: Initiate

Prior Notice: 

Critical: Y

Reqrd Rsp Desc: No Response Required
Post

Notice Effective

Notice End



Response
Post Date: 09/02/26

09/02/26

10/02/26
Subject: Subject: Alexandria Compressor Station Maintenance (AlexSEG), September 9, 2026
Author: Author: Dillon Schoolcraft
Notice Text
Columbia Gulf Transmission LLC (CGT) notifies customers of upcoming at Alexandria Compressor Station on Wednesday, September 9, 20266. As a result, the backhaul capacity through AlexSEG will be reduced to 2,450,000 Dth effective Timely Cycle for Gas Day Wednesday, September 9, 2026.

CGT anticipates this restriction may result in curtailments to Interruptible, Secondary Firm, and Primary Firm services. Please see the details provided below for more information.

AlexSEG

·       Estimated Capacity Setting: 2,450,000 Dth

·       Design Capacity: 2,683,256 Dth

·       Posted Percentage: 91%

Due to the potential impact to firm service, CGT encourages customers to monitor the scheduled volumes on the Operationally Available Capacity screen on Informational Postings, as nominations can fluctuate based on market conditions. 

Reservation Charge Credits (RCCs) will be determined per the process set forth in the General Terms and Conditions, Section 40 of CGT’s FERC Gas Tariff (Tariff). By means of this notice, CGT is establishing the 7-day Average Usage Quantity to be the period of August 20-26, 2026, pursuant to the provisions in the Tariff. 

Please contact your Customer Services Representative with any questions.
Columbia Gulf Transmission (CGT)

Hartsville Compressor Station Maintenance (HartSEG), September 9-30, 2026

SEV 3/5
Maintenance 0.245 Bcf/d 22 Days

CGT has issued a planned maintenance notice for Hartsville Compressor Station (HartSEG) from September 9 through September 30, 2026, reducing backhaul capacity to 2,300,000-2,400,000 Dth/d versus the design capacity of 2,544,656 Dth/d -- a restriction of roughly 144,656-244,656 Dth/d (0.145-0.245 Bcf/d). CGT explicitly warns this may result in curtailments to Interruptible, Secondary Firm, and Primary Firm services. The HartSEG capacity table as of the 2026-09-02 timely cycle shows the segment running at approximately 84.6% utilization at 2.15 Bcf/d scheduled against 2.54 Bcf/d operating capacity, suggesting the upcoming restriction will bite into current headroom and create genuine firm-service curtailment risk.

CGT HartSEG planned maintenance removes approximately 0.145-0.245 Bcf/d of backhaul capacity starting September 9, elevating firm curtailment risk on a corridor that was already at ~85% utilization as of the 2026-09-02 timely cycle; Columbia Gulf mainline basis has been trading around -0.285 to -0.288 vs Henry Hub over the five trading days ended 2026-09-01, and tighter backhaul capacity through HartSEG is bullish for Transco Zone 4 and downstream Southeast markets while adding marginal bearish pressure to Gulf Coast/Haynesville supply points that rely on CGT northbound flow.
Reroute: Moderate: Texas Eastern (TETCO), Trunkline (TGC), and ANR serve overlapping Gulf Coast northbound corridors, but the explicit firm-service curtailment warning from CGT suggests HartSEG is already a critical constraint point with limited slack; affected shippers should pursue alternate paths early as September 9 approaches.
View original notice text
TSP Name Columbia Gulf Transmission, LLC
TSP 007854581
Notice Type Description: Maintenance

Notice Stat Desc: Initiate

Prior Notice: 

Critical: Y

Reqrd Rsp Desc: No Response Required
Post

Notice Effective

Notice End



Response
Post Date: 09/02/26

09/02/26

10/02/26
Subject: Subject: Hartsville Compressor Station Maintenance (HartSEG), September 9-30, 2026
Author: Author: Dillon Schoolcraft
Notice Text
Columbia Gulf Transmission LLC (CGT) notifies customers of upcoming maintenance at Hartsville Compressor Station beginning on Wednesday, September 9, 2026, through Wednesday, September 30, 2026. As a result, the backhaul capacity through HartSEG will be reduced to a level between 2,300,000 – 2,400,000 Dth effective Timely Cycle for Gas Day Wednesday, September 9, 2026. 

CGT anticipates this restriction may result in curtailments to Interruptible, Secondary Firm, and Primary Firm services. Please see the details provided below for more information.

HartSEG

·       Estimated Capacity Setting: 2,300,000 – 2,400,000 Dth 

·       Design Capacity: 2,544,656 Dth

·       Posted Percentage: 90-94%

Due to the potential impact to firm service, CGT encourages customers to monitor the scheduled volumes on the Operationally Available Capacity screen on Informational Postings, as nominations can fluctuate based on market conditions. 

Reservation Charge Credits (RCCs) will be determined per the process set forth in the General Terms and Conditions, Section 40 of CGT’s FERC Gas Tariff (Tariff). By means of this notice, CGT is establishing the 7-day Average Usage Quantity to be the period of August 20-26, 2026, pursuant to the provisions in the Tariff. 

Please contact your Customer Services Representative with any questions.
Gulf South Pipeline

Gulf South Inability to Take Confirmed Quantities on Index 296

SEV 3/5
Informational Until Further Notice

Pre-screen severity 3 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Pipeline: Gulf South Pipeline
Notice ID: 5038661
Notice Type: Over-Under Performance
Status: Initiate
Posted: 2026-09-02T12:04:00+00:00
Effective: 2026-09-02T12:05:00+00:00
End: 
Subject: Gulf South Inability to Take Confirmed Quantities on Index 296 

Gulf South Pipeline Notice 5038661
Source Link
All information here is provided as a service and information is not guaranteed to be accurate. PipeRiv is not responsible for any incorrect information.
TSP Name :
Gulf South Pipeline Company, LLC
Category :
Critical
Notice Type Desc :
Over-Under Performance
Notice Stat Desc :
Initiate
Notice ID :
5038661
Prior Notice :
Reqrd Rsp Desc :
No response required
Subject :
Gulf South Inability to Take Confirmed Quantities on Index
TSP :
078444247
Post Date/Time :
09/02/2026 12:04:00 PM
Notice Effective Date/Time :
09/02/2026 12:05:00 PM
Notice End Date/Time :
Response Date/Time :
Critical :
Notice Text :
Gulf South Pipeline Company, LLC (“Gulf South”) has limited operational receipt flexibility on
Index 296 related to the "Unplanned Index 296 Pipeline Maintenance" (Notice I.D. 5038650).
As a result, effective ID1, September 2, 2026, the "Index 296 Receipts" scheduling group will be
reduced to 25,000 Dth/day until further notice. The following locations are included in the
"Index 296 Receipts" scheduling group and will be impacted:
• Discovery (SLN 21805)
• Louisiana Delta Farms (SLN 22537)
• Bully Camp (SLN 9154)
• Golden Meadow (SLN 45)
• Bully Camp (SLN 9694)
If you have any questions, please contact your customer service representative.
Notice
Page 1 of 1
09/02/2026 12:05:10 PM
Notice
TSP Name :
Gulf South Pipeline Company, LLC
TSP :
078444247
Category :
Critical
Post Date/Time :
09/02/2026 12:04:00 PM
Notice Type Desc :
Over-Under Performance
Notice Effective Date/Time :
09/02/2026 12:05:00 PM
Notice Stat Desc :
Initiate
Notice End Date/Time :
Notice ID :
5038661
Response Date/Time :
Prior Notice :
Critical :
Reqrd Rsp Desc :
No response required
Subject :
Gulf South Inability to Take Confirmed Quantities on Index
Notice Text :
Gulf South Pipeline Company, LLC (“Gulf South”) has limited operational receipt flexibility on
Index 296 related to the "Unplanned Index 296 Pipeline Maintenance" (Notice I.D. 5038650).
As a result, effective ID1, September 2, 2026, the "Index 296 Receipts" scheduling group will be
reduced to 25,000 Dth/day until further notice. The following locations are included in the
"Index 296 Receipts" scheduling group and will be impacted:
• Discovery (SLN 21805)
• Louisiana Delta Farms (SLN 22537)
• Bully Camp (SLN 9154)
• Golden Meadow (SLN 45)
• Bully Camp (SLN 9694)
If you have any questions, please contact your customer service representative.
09/02/2026 12:05:10 PM
Page 1 of 1
Columbia Gas Transmission (TCO)

Operational Alert – Potential Critical Days & Receipt Point OFO, Effective September 5, 2026

SEV 3/5
Informational Until Further Notice

Pre-screen severity 3 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name Columbia Gas Transmission, LLC
TSP 054748041
Notice Type Description: Operational Alert

Notice Stat Desc: Initiate

Prior Notice: 

Critical: Y

Reqrd Rsp Desc: No Response Required
Post

Notice Effective

Notice End



Response
Post Date: 09/02/26

09/02/26

10/02/26
Subject: Subject: Operational Alert – Potential Critical Days & Receipt Point OFO, Effective September 5, 2026
Author: Author: Jonah Skiles
Notice Text
In an effort to communicate current operating conditions to customers, Columbia Gas Transmission, LLC (TCO) is anticipating it may be necessary to implement as early as issuing the following Operational Alert effective Saturday, September 5, 2026, and continuing until further notice.  

Potential Critical Day for Storage Injections: 

It may become necessary for TCO to limit storage injections to firm quantities only, which would constitute a Critical Day in storage, as early as Gas Day Saturday, September 5, 2026. The potential for a Storage Critical Day is due primarily to forecasted mild weather, higher storage and line pack levels, and reduced market demand resulting in increased daily injections into customer’s storage accounts. Customers can assist TCO operations and reduce the potential need for a Critical Day by not exceeding their Maximum Daily Injection Quantities and keeping supplies and markets balanced. 

Firm Storage Service (FSS) shippers are reminded that, per section 3(c) of the FSS Rate Schedule, the Maximum Monthly Injection Quantity (MMIQ) for September is 13% of the Storage Contract Quantity (SCQ), and the Maximum Daily Injection Quantity (MDIQ) is 1/25th of the MMIQ.  

Pre OFO – Receipt Points in Market Areas 26, 30, 35, 41, 42:

TCO notifies all Shippers under all Transportation Rate Schedules within its FERC Gas Tariff, and Meter Operators in Market Areas 26, 30, 35, 41, and 42, that the issuance of an Operational Flow Order (OFO) may become necessary beginning as early as September 5, 2026, to preserve system integrity and protect the operating performance of TCO’s pipeline system.

Pursuant to Section 17.1(d) of the General Terms and Conditions of its Tariff, TCO is providing advanced warning of the operational variables that may in the future give rise to the issuance of an OFO. The operational variables that may require issuance of an OFO in the future are the following.

 

Due to forecasted mild weather and the anticipated lower market demand, TCO has experienced excess receipts during a time when storage and line pack levels are high. TCO has limited operational flexibility for positive imbalances and cannot allow actual receipts to exceed scheduled receipts.

 

In order to avoid the issuance of an OFO, receipt points must be balanced such that actual receipts into Market Areas 26, 30, 35, 41, and 42 are equal to or less than the scheduled receipt quantities in these Areas. Any excess receipts can threaten the operational integrity of TCO’s system and TCO’s ability to maintain its firm obligations. An OFO may also be avoided if Shippers and Meter Operators adjust nominations to align with flowing supplies during each nomination cycle. 

 

In the event TCO is forced to issue an OFO, Shippers who do not comply will be subject to penalties in accordance with Section 19.3 of TCO’s Tariff.

Imbalances and AutoPAL:

As noted above, TCO has limited operational flexibility for positive imbalances, including positive AutoPAL balances. Physical flows must match scheduled quantities to prevent further action. As a reminder, the intent of the AutoPAL service is to utilize nominal quantities to resolve minor pool imbalances that result from small upstream or downstream reductions during the cycles of the Gas Day. These quantities are then paid back the next cycle of the Gas Day. 

TCO will monitor AutoPAL activity and reserves the right to adjust the current AutoPAL limits, make AutoPAL unavailable, or declare an OFO to prevent abuse.

  

TCO encourages customers to monitor critical notices, including the Daily Capacity Posting, for updates. Please contact your Customer Services or Marketing Representative with any questions.
Panhandle Eastern Pipe Line

[Panhandle Eastern Pipe Line] [Maintenance] PEPL Sunray Outage Update #1

SEV 3/5
Informational Until Further Notice

Pre-screen severity 3 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Pipeline: Panhandle Eastern Pipe Line
Notice ID: 68273
Notice Type: Maintenance
Subject: PEPL Sunray Outage Update #1
Posted: 2026-09-02 07:15:00.0
Effective: 2026-09-02 07:15:00.0
End Date: 

Notice ID: 68273
Notice Type: MAI
Critical: Y
Reqrd Rsp Desc: No Response Required
Posting Date/Time: 2026-09-02 07:15:00.0
Subject: PEPL Sunray Outage Update #1
Notice Effective Date/Time: 2026-09-02 07:15:00.0
Notice End Date/Time: 2200-01-01 00:00:00.0
Location #: Location Name
40524: Sunray Gas Plant
Panhandle Eastern Pipe Line

[Panhandle Eastern Pipe Line] [Maintenance] PEPL Chisolm Plant Outage

SEV 3/5
Informational Until Further Notice

Pre-screen severity 3 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Pipeline: Panhandle Eastern Pipe Line
Notice ID: 68275
Notice Type: Maintenance
Subject: PEPL Chisolm Plant Outage
Posted: 2026-09-02 07:42:00.0
Effective: 2026-09-02 07:42:00.0
End Date: 

Notice ID: 68275
Notice Type: MAI
Critical: Y
Reqrd Rsp Desc: No Response Required
Posting Date/Time: 2026-09-02 07:42:00.0
Subject: PEPL Chisolm Plant Outage
Notice Effective Date/Time: 2026-09-02 07:42:00.0
Notice End Date/Time: 2200-01-01 00:00:00.0
Location #: Location Name
41433: Chisholm Plant
Transwestern Pipeline

[Transwestern Pipeline] [Operational Alert] CRITICAL NOTICE - SAME DAY - UNDERAGE ALERT - PHOENIX AREA

SEV 3/5
Informational

Pre-screen severity 3 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Pipeline: Transwestern Pipeline
Notice ID: 120364
Notice Type: Operational Alert
Subject: CRITICAL NOTICE - SAME DAY - UNDERAGE ALERT - PHOENIX AREA
Posted: Sep 2 2026 7:41AM
Effective: Sep 2 2026 7:40AM
End Date: Sep 3 2026 8:59AM

Notice Type Description: Operational Alert
Notice Identifier: 120364
Critical Notice Description: Critical notice
Posting Date/Time: Sep 2 2026 7:41AM
Notice Status Description: Initiate
Required Response Indicator Description: No response required
TSP: 7933047
TSP Name: TRANSWESTERN PIPELINE COMPANY, LLC
Subject: CRITICAL NOTICE - SAME DAY - UNDERAGE ALERT - PHOENIX AREA
Notice Effective Date/Time: Sep 2 2026 7:40AM
Notice End Date/Time: Sep 3 2026 8:59AM
Notice Text: CRITICAL NOTICE - SAME DAY - UNDERAGE ALERT - PHOENIX AREASeptember 2, 2026Due to high line pack in the Phoenix Area, Transwestern is declaring a Same Day Underage Alert for the Phoenix Area for gas day, September 2, 2026. Any Operator of a delivery point in the Phoenix Area at which actual quantities are less than scheduled quantities on this Alert Day shall be subject to Alert Day charges in accordance with Section 22.4 of the General Terms and Conditions of Transwestern's FERC Gas Tariff.Based upon current operating conditions, Transwestern anticipates that this high line pack condition will continue at least for the entire gas day. Transwestern will provide additional information concerning this Alert Day condition as necessary.Please contact Gas Control or your marketing representative with any questions
Florida Gas Transmission

[Florida Gas Transmission] [Operational Alert] Overage Alert Day 15% Tolerance

SEV 3/5
Operational Alert 1 Days

FGT has declared an Overage Alert Day at 15% tolerance for gas day September 2, 2026, effective 9:00 AM through September 3, 2026 9:00 AM. The notice cites 90-degree temperatures forecast across Florida over the next several days with FGT linepack already below target levels, creating demand-side pressure on the system. FGT will not interrupt previously scheduled Market Area ITS-1 service below elapsed prorated scheduled quantities but is warning customers to closely monitor actual burn versus scheduled volumes.

FGT overage alert tightens Florida supply with linepack below target during a heat event; Florida Gas Zone 3 basis was already at +2.315 vs Henry Hub on 2026-09-01 (trailing 5-day avg +2.013), and sustained 90-degree Florida temperatures with sub-target linepack create further upside basis risk with no reroute available to offset any supply shortfall.
Reroute: None: FGT is the sole large-diameter interstate pipeline serving the Florida peninsula; no bypass exists and no alternative pipeline can replace FGT deliveries into the Florida market.
View original notice text
Pipeline: Florida Gas Transmission
Notice ID: 68272
Notice Type: Operational Alert
Subject: Overage Alert Day 15% Tolerance
Posted: Sep 2 2026 6:51 AM
Effective: Sep 2 2026 9:00 AM
End Date: Sep 3 2026 9:00 AM

Notice ID: 68272
Notice Type: Operational Alert
Critical: Y
Notice Status Description: Initiate
Reqrd Rsp Desc: No Response Required
Posting Date/Time: Sep 2 2026 6:51 AM
Subject: Overage Alert Day 15% Tolerance
Notice Effective Date/Time: Sep 2 2026 9:00 AM
Notice End Date/Time: Sep 3 2026 9:00 AM
Notice Text: 90-degree temperatures are forecasted in Florida over the next several days and FGT linepack is below target levels; therefore, for the gas day of September 2, 2026, FGT would like to notify their customers in the FGT Market Area that it is issuing an Overage Alert Day at 15% (Fifteen Percent) tolerance.For the gas day of September 2, 2026, FGT will not interrupt previously scheduled Market Area ITS-1 service below the elapsed prorated scheduled quantity.FGT will continue to monitor hourly and daily takes. Please closely monitor your scheduled point quantities versus actual burn point quantities.
Texas Eastern Transmission (TETCO)

09/01/2026- TE Pipeline Conditions for 9/2/2026

SEV 3/5
Informational

Pre-screen severity 3 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name: Texas Eastern Transmission, LP
Subject: TE Pipeline Conditions for 9/2/2026
Notice Type: Capacity Constraint
Critical Notice Description: Critical notice
Notice Status Description: Initiate
Notice Effective Date: 09/02/2026
Notice End Date: 09/03/2026
Posting Date: 09/01/2026
Notice Identifier: 182465
Required Response Indicator Description: No response required

For Gas Day September 2, 2026, Texas Eastern (TE) has approved and scheduled nominations at each pipeline segment and meter station up to TE's operational capacity. The following locations have been restricted due to requested nominations exceeding TE's operational capacity:
Restricted Locations
Scheduled and Sealed
Priority % Restricted
Notes
TABS
North of Berne
Meter 75919 Deliveries
N/A
100%
100%
86%
Rec from AGT & Del West of Lambertville
100%
100%
100%
TE/AGT Lease
Yes
To Lease Capacity
Nexus/TE Leased Meters
Yes
To Lease Capacity
30" South of Berne
Berne - Southbound
N/A
100%
100%
Danville - Southbound
N/A
100%
100%
Tompkinsville - Southbound
N/A
100%
100%
Barton - Southbound
N/A
100%
100%
24"
Sarahsville - Southbound
N/A
100%
100%
100%
28%
Unplanned Outage
Five Points - Southbound
N/A
100%
73%
Unplanned Outage
Lebanon
N/A
100%
60%
Unplanned Outage
Lebanon Lateral
N/A
100%
93%
Batesville - Southbound
N/A
100%
50%
Meter 74215 Deliveries
Yes
Access Area
Union Church - Southbound
N/A
100%
New Roads South - Southbound
N/A
100%
95%
White Castle - Southbound
N/A
100%
93%
Longview - Northbound
N/A
100%
31%
Huntsville - Northbound
Yes
Speaks - Southbound
N/A
100%
81%
Angleton West - Northbound
N/A
100%
54%
Vidor East - Northbound
Yes
Gillis - Northbound
N/A
100%
56%
TABS Pool Restrictions - Tolerances
ETX
STX
WLA
ELA
M1-24"
M1-30"
M2-24"
M2-30"
TABS Pool - Length
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
TABS Pool - Short
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
No-Notice Restrictions
OFO / Imbalance Notice
OFO
---
Action Alert
No DP - M2-24, M2-30 and M3 issued 9/2/2026. 10% / 500 Dth/d Tolerance
Customer Specific OFO
---
Imbalance Warnings
Stay Balanced - Access Area, M1-24 and M1-30.
FERC Order 698
M2-24, M2-30 and M3
Gas Quality:
Due to ongoing gas quality issues at meters 73915, 73713,73733 and 73714, TE will require a partial reduction of flow beginning as soon as September 9, 2026, if gas quality issues are not corrected by that date. These meter operators will remain at a reduced flow, and will be subject to further reductions, until the gas entering TE's system is compliant with TE's gas quality standards in its GT&C. The upstream point operators are required to ensure nominations are commensurate with the physical flow, or non-performance confirmation reductions may be required.
Due to gas quality issues, meter 76609 has been shut in and physical receipts at the meter will be unavailable until further notice.  Beginning during the Timely cycle for Gas Day December 6, 2025, and until further notice, TE will restrict receipt nominations at Meter 76609 to -0- Dth/d.
Systemwide Notes:
Shippers in all Texas Eastern's Access Area Zones and Market Area Zones M1-30, M2-30 and M3 are required to coordinate any imbalance payback through TE's account representative and actual payback quantities may be limited depending on system operations and conditions. If customers do not adhere to imbalance requirements stated above, TE will utilize any provision of its tariff to ensure system integrity including the issuance of customer specific or system wide OFOs.
Please contact your Operations Account Representative should you have any questions.
East Tennessee Natural Gas

09/01/2026- ETNG Pipeline Conditions for 9/2/2026

SEV 3/5
Informational

Pre-screen severity 3 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name: East Tennessee Natural Gas, LLC
Subject: ETNG Pipeline Conditions for 9/2/2026
Notice Type: Capacity Constraint
Critical Notice Description: Critical notice
Notice Status Description: Initiate
Notice Effective Date: 09/02/2026
Notice End Date: 09/03/2026
Posting Date: 09/01/2026
Notice Identifier: 182442
Required Response Indicator Description: No response required

For Gas Day September 2, 2026, East Tennessee Natural Gas (ETNG) has approved and scheduled nominations at each pipeline segment and meter station up to ETNG's operational capacity. The following locations have been restricted due to requested nominations exceeding ETNG's operational capacity:
Restricted Locations
Scheduled and Sealed
Priority % Restricted
Notes
Deliveries To Texas Eastern
100%
100%
Topside South
100%
100%
85%
Boyds Creek - Westbound
100%
100%
100%
Fordtown West - Westbound
Yes
Flatwoods East - Westbound
Yes
OFO / Imbalance Notice
OFO
---
Customer Specific OFO
---
Hourly Customer Specific OFO
---
Action Alert
---
Imbalances Warnings
Stay Balanced
Systemwide Notes:
ETNG requires any imbalance payback be coordinated through your Operations Account Representative.
If necessary, ETNG will utilize any provision of its tariff to ensure system integrity including the issuance of customer specific or system wide OFOs.
Effective October 1, 2025, MR 59200 - SNG Whitfield will be restricted to 0 Dth / d until further notice due to SNG pressures being lower than ETNG's typical operating pressure. Also, effective October 1, 2025, MR 59311 - SNG Bradley will be limited to its meter capacity of 31,000 Dth/d.
Customers are advised that capacity may become available as the nomination and confirmation process continues throughout the day.
Please contact your Operations Account Representative should you have any questions.
Algonquin Gas Transmission

09/01/2026- Algonquin Operational Notice

SEV 3/5
Informational

Pre-screen severity 3 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name: Algonquin Gas Transmission, LLC
Subject: Algonquin Operational Notice
Notice Type: Capacity Constraint
Critical Notice Description: Critical notice
Notice Status Description: Initiate
Notice Effective Date: 09/01/2026
Notice End Date: 11/30/2026
Posting Date: 09/01/2026
Notice Identifier: 182423
Required Response Indicator Description: No response required

00011
TAUNTON (BRISTOL, MA)
00012
RHODE ISLAND ENERGY - WARREN (BRISTOL, RI)
00013
RHODE ISLAND ENERGY- PORTSMOUTH (NEWPORT, RI)
00015
FREETOWN (BRISTOL, MA)
00016
NEW ENGLAND GAS COMPANY FALL RIVER (BRISTOL, MA)
00017
NEW BEDFORD (BRISTOL, MA)
00018
BOURNE STATION RELOCATION (MAINLAND BOURNE)
00019
PLYMOUTH (PLYMOUTH, MA)
00029
MIDDLEBORO (PLYMOUTH, MA)
00033
RHODE ISLAND ENERGY - TIVERTON (NEWPORT, RI)
00049
NEW ENGLAND GAS COMPANY WESTPORT (BRISTOL, MA)
00051
SAGAMORE STATION RELOCATION (MAINLAND SAGAMORE)
00064
RHODE ISLAND ENERGY-BARRINGTON (PROVIDENCE, RI)
00071
NEW ENGLAND GAS COMPANY SWANSEA (BRISTOL, MA)
00093
DARTMOUTH POWER (NORFOLK, MA)
00806
CANAL GENERATING
00812
TMPL (BRISTOL, MA)
00813
NATIONAL GRID-ROCHESTER (PLYMOUTH, MA)
00815
DIGHTON POWER LLC BRISTOL MA (BRISTOL, MA)
00816
REVERE POWER (PROVIDENCE, RI)
00821
PINEHILLS METER - (PLYMOUTH, MA)
00824
NEW ENGLAND GAS COMPANY FALL RIVER GAS-NORTH FALL RIVER STA-(BRIST
00829
NATIONAL GRID-SANDWICH (BARNSTABLE, MA)
00839
NSTAR - ASSONET, BRISTOL CO, MA
80003
INTERCONNECT AGT G-10 LAT & CLEARY LATERAL
80004
INTERCONNECT AGT G-SYS BOURNE, MA & CANAL LATERAL
80047
LATERAL G SYSTEM CANAL MAINLINE
80049
LATERAL G SYSTEM CLEARY MAINLINE
80806
G-24 MAINLINE HEAD OF LATERAL
99825
FALL RIVER GAS
00020
MILFORD (WORCESTER, MA)
00021
NATIONAL GRID- NORWOOD (NORFOLK, MA)
00022
WESTWOOD (NORFOLK, MA)
00023
NATIONAL GRID- EAST BRAINTREE (NORFOLK, MA)
00024
BROCKTON (PLYMOUTH, MA)
00025
HOPEDALE (NORFOLK, MA)
00027
NATIONAL GRID- EVERETT (MIDDLESEX, MA)
00028
BROOKFORD ST (MIDDLESEX, MA)
00032
NATIONAL GRID-WALTHAM (MIDDLESEX, MA)
00036
WEST MEDWAY (NORFOLK, MA)
00038
CHARLES RIVER RD (NORFOLK, MA)
00043
ASHLAND (MIDDLESEX, MA)
00052
NATIONAL GRID-PONKAPOAG (NORFOLK, MA)
00057
NATIONAL GRID-WESTON (MIDDLESEX, MA)
00058
CANTON (NORFOLK, MA)
00061
WOODLAND RD (NORFOLK, MA)
00074
NATIONAL GRID-WELLESLEY (NORFOLK, MA)
00080
NATIONAL GRID-POLAROID (MIDDLESEX, MA)
00081
NATIONAL GRID-POTTER ST. (NORFOLK, MA)
00089
NATIONAL GRID-MEDFORD (MIDDLESEX, MA)
00094
BELLINGHAM (NORFOLK, MA)
00206
LINCOLN (MIDDLESEX, MA)
00215
SALEM ESSEX CO., MA (ESSEX, MA)
00230
MARATHON (MIDDLESEX, MA)
00271
EVERETT INT. (MIDDLESEX, MA)
00620
EXCELERATE ENERGY LP - EXCELERATE MS - (ESSEX, MA)
00621
EXCELERATE ENERGY LP - EXCELLENCE MS - (ESSEX, MA)
00622
EXCELERATE ENERGY LP - NE GATEWAY-EXPLORER (ESSEX, MA)
00624
EXCELERATE ENERGY LP - EXQUISITE (ESSEX, MA)
00625
EXCELERATE ENERGY LP - EXPEDIENT (ESSEX, MA)
00626
EXCELERATE ENERGY LP - EXEMPLAR (ESSEX, MA)
00630
SUEZ NEPTUNE LNG - (ESSEX, MA)
00631
SUEZ CAPE ANN, LNG - (ESSEX, MA)
00801
MILFORD POWER
00803
FORE RIVER (NORFOLK, MA)
00814
ANP BELLINGHAM ENERGY COMPANY (NORFOLK, MA)
00823
SHARON STATION- (NORFOLK, MA)
00826
MYSTIC (MIDDLESEX, MA)
00827
NATIONAL GRID-WEYMOUTH (NORFOLK, MA)
00830
MARATHON (MIDDLESEX, MA)
00832
NORFOLK METER STATION (NORFOLK, MA)
00834
BELD - BRAINTREE ELECTRIC LIGHT (NORFOLK, MA)
00837
SALEM HARBOR STATION
00838
NATIONAL GRID - WEST ROXBURY
00844
EXELON/CONSTELLATION ENERGY, NORFOLK CO., MA
01215
SALEM ESSEX CO., MA NORTH (ESSEX, MA)
02630
NEPTUNE LNG - (ESSEX, MA)
80012
LATERAL Y SYSTEM
80013
LATERAL Y SYSTEM MAINLINE
80022
LATERAL T SYSTEM
80023
LATERAL T SYSTEM MAINLINE
80042
Q-1 EXTENSION MAINLINE
80060
G-24 LATERAL HEAD OF LATERAL
80094
J-2 SYSTEM
80095
J-2 SYSTEM MAINLINE
80104
WEST ROXBURY LATERAL
80105
WEST ROXBURY LATERAL (MAINLINE)
80106
SALEM LATERAL (MAINLINE)
80107
SALEM LATERAL
80108
LINCOLN LATERAL (MAINLINE)
80109
LINCOLN LATERAL
88202
INTERCONNECTION BETWEEN NORTHEAST GATEWAY AND HUBLINE MAINLINE
88203
INTERCONNECTION BETWEEN NORTHEAST GATEWAY AND HUBLINE
88271
DISTRIGAS - EVERETT
89847
NORTHEAST GATEWAY DEEP WATER PORT (DWP1)
89848
INTERCONNECT BETWEEN SUEZ NEPTUNE AND HUBLINE
99817
EVERSOURCE GAS COMPANY OF MA
99818
BOS GAS CO D
99822
NSTAR
99837
DISTRIGAS LDC
99855
SALEM LATERAL CUSTODY TRANSFER POINT
99857
EAST BRAINTREE CUSTODY TRANSFER POINT
Algonquin Gas Transmission

09/01/2026- Algonquin Operational Notice - UPDATE

SEV 3/5
Informational

Pre-screen severity 3 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name: Algonquin Gas Transmission, LLC
Subject: Algonquin Operational Notice - UPDATE
Notice Type: Capacity Constraint
Critical Notice Description: Critical notice
Notice Status Description: Supersede
Notice Effective Date: 09/01/2026
Notice End Date: 11/30/2026
Posting Date: 09/01/2026
Notice Identifier: 182434
Prior Notice Identifier: 182423
Required Response Indicator Description: No response required

00011
TAUNTON (BRISTOL, MA)
00013
RHODE ISLAND ENERGY- PORTSMOUTH (NEWPORT, RI)
00015
FREETOWN (BRISTOL, MA)
00016
NEW ENGLAND GAS COMPANY FALL RIVER (BRISTOL, MA)
00017
NEW BEDFORD (BRISTOL, MA)
00018
BOURNE STATION RELOCATION (MAINLAND BOURNE)
00019
PLYMOUTH (PLYMOUTH, MA)
00029
MIDDLEBORO (PLYMOUTH, MA)
00033
RHODE ISLAND ENERGY - TIVERTON (NEWPORT, RI)
00049
NEW ENGLAND GAS COMPANY WESTPORT (BRISTOL, MA)
00051
SAGAMORE STATION RELOCATION (MAINLAND SAGAMORE)
00093
DARTMOUTH POWER (NORFOLK, MA)
00806
CANAL GENERATING
00812
TMPL (BRISTOL, MA)
00813
NATIONAL GRID-ROCHESTER (PLYMOUTH, MA)
00815
DIGHTON POWER LLC BRISTOL MA (BRISTOL, MA)
00816
REVERE POWER (PROVIDENCE, RI)
00821
PINEHILLS METER - (PLYMOUTH, MA)
00824
NEW ENGLAND GAS COMPANY FALL RIVER GAS-NORTH FALL RIVER STA-(BRIST
00829
NATIONAL GRID-SANDWICH (BARNSTABLE, MA)
00839
NSTAR - ASSONET, BRISTOL CO, MA
80003
INTERCONNECT AGT G-10 LAT & CLEARY LATERAL
80004
INTERCONNECT AGT G-SYS BOURNE, MA & CANAL LATERAL
80047
LATERAL G SYSTEM CANAL MAINLINE
80049
LATERAL G SYSTEM CLEARY MAINLINE
80806
G-24 MAINLINE HEAD OF LATERAL
99825
FALL RIVER GAS
00020
MILFORD (WORCESTER, MA)
00021
NATIONAL GRID- NORWOOD (NORFOLK, MA)
00022
WESTWOOD (NORFOLK, MA)
00023
NATIONAL GRID- EAST BRAINTREE (NORFOLK, MA)
00024
BROCKTON (PLYMOUTH, MA)
00025
HOPEDALE (NORFOLK, MA)
00027
NATIONAL GRID- EVERETT (MIDDLESEX, MA)
00028
BROOKFORD ST (MIDDLESEX, MA)
00032
NATIONAL GRID-WALTHAM (MIDDLESEX, MA)
00036
WEST MEDWAY (NORFOLK, MA)
00038
CHARLES RIVER RD (NORFOLK, MA)
00043
ASHLAND (MIDDLESEX, MA)
00052
NATIONAL GRID-PONKAPOAG (NORFOLK, MA)
00057
NATIONAL GRID-WESTON (MIDDLESEX, MA)
00058
CANTON (NORFOLK, MA)
00061
WOODLAND RD (NORFOLK, MA)
00074
NATIONAL GRID-WELLESLEY (NORFOLK, MA)
00080
NATIONAL GRID-POLAROID (MIDDLESEX, MA)
00081
NATIONAL GRID-POTTER ST. (NORFOLK, MA)
00089
NATIONAL GRID-MEDFORD (MIDDLESEX, MA)
00094
BELLINGHAM (NORFOLK, MA)
00206
LINCOLN (MIDDLESEX, MA)
00215
SALEM ESSEX CO., MA (ESSEX, MA)
00230
MARATHON (MIDDLESEX, MA)
00271
EVERETT INT. (MIDDLESEX, MA)
00620
EXCELERATE ENERGY LP - EXCELERATE MS - (ESSEX, MA)
00621
EXCELERATE ENERGY LP - EXCELLENCE MS - (ESSEX, MA)
00622
EXCELERATE ENERGY LP - NE GATEWAY-EXPLORER (ESSEX, MA)
00624
EXCELERATE ENERGY LP - EXQUISITE (ESSEX, MA)
00625
EXCELERATE ENERGY LP - EXPEDIENT (ESSEX, MA)
00626
EXCELERATE ENERGY LP - EXEMPLAR (ESSEX, MA)
00630
SUEZ NEPTUNE LNG - (ESSEX, MA)
00631
SUEZ CAPE ANN, LNG - (ESSEX, MA)
00801
MILFORD POWER
00803
FORE RIVER (NORFOLK, MA)
00814
ANP BELLINGHAM ENERGY COMPANY (NORFOLK, MA)
00823
SHARON STATION- (NORFOLK, MA)
00826
MYSTIC (MIDDLESEX, MA)
00827
NATIONAL GRID-WEYMOUTH (NORFOLK, MA)
00830
MARATHON (MIDDLESEX, MA)
00832
NORFOLK METER STATION (NORFOLK, MA)
00834
BELD - BRAINTREE ELECTRIC LIGHT (NORFOLK, MA)
00837
SALEM HARBOR STATION
00838
NATIONAL GRID - WEST ROXBURY
00844
EXELON/CONSTELLATION ENERGY, NORFOLK CO., MA
01215
SALEM ESSEX CO., MA NORTH (ESSEX, MA)
02630
NEPTUNE LNG - (ESSEX, MA)
80012
LATERAL Y SYSTEM
80013
LATERAL Y SYSTEM MAINLINE
80022
LATERAL T SYSTEM
80023
LATERAL T SYSTEM MAINLINE
80042
Q-1 EXTENSION MAINLINE
80060
G-24 LATERAL HEAD OF LATERAL
80094
J-2 SYSTEM
80095
J-2 SYSTEM MAINLINE
80104
WEST ROXBURY LATERAL
80105
WEST ROXBURY LATERAL (MAINLINE)
80106
SALEM LATERAL (MAINLINE)
80107
SALEM LATERAL
80108
LINCOLN LATERAL (MAINLINE)
80109
LINCOLN LATERAL
88202
INTERCONNECTION BETWEEN NORTHEAST GATEWAY AND HUBLINE MAINLINE
88203
INTERCONNECTION BETWEEN NORTHEAST GATEWAY AND HUBLINE
88271
DISTRIGAS - EVERETT
89847
NORTHEAST GATEWAY DEEP WATER PORT (DWP1)
89848
INTERCONNECT BETWEEN SUEZ NEPTUNE AND HUBLINE
99817
EVERSOURCE GAS COMPANY OF MA
99818
BOS GAS CO D
99822
NSTAR
99837
DISTRIGAS LDC
99855
SALEM LATERAL CUSTODY TRANSFER POINT
99857
EAST BRAINTREE CUSTODY TRANSFER POINT
Algonquin Gas Transmission

09/01/2026- Algonquin Operational Notice - UPDATE

SEV 3/5
Informational

Pre-screen severity 3 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name: Algonquin Gas Transmission, LLC
Subject: Algonquin Operational Notice - UPDATE
Notice Type: Capacity Constraint
Critical Notice Description: Critical notice
Notice Status Description: Supersede
Notice Effective Date: 09/01/2026
Notice End Date: 11/30/2026
Posting Date: 09/01/2026
Notice Identifier: 182435
Prior Notice Identifier: 182434
Required Response Indicator Description: No response required

00011
TAUNTON (BRISTOL, MA)
00013
RHODE ISLAND ENERGY- PORTSMOUTH (NEWPORT, RI)
00015
FREETOWN (BRISTOL, MA)
00016
NEW ENGLAND GAS COMPANY FALL RIVER (BRISTOL, MA)
00017
NEW BEDFORD (BRISTOL, MA)
00018
BOURNE STATION RELOCATION (MAINLAND BOURNE)
00019
PLYMOUTH (PLYMOUTH, MA)
00029
MIDDLEBORO (PLYMOUTH, MA)
00033
RHODE ISLAND ENERGY - TIVERTON (NEWPORT, RI)
00049
NEW ENGLAND GAS COMPANY WESTPORT (BRISTOL, MA)
00051
SAGAMORE STATION RELOCATION (MAINLAND SAGAMORE)
00093
DARTMOUTH POWER (NORFOLK, MA)
00806
CANAL GENERATING
00812
TMPL (BRISTOL, MA)
00813
NATIONAL GRID-ROCHESTER (PLYMOUTH, MA)
00815
DIGHTON POWER LLC BRISTOL MA (BRISTOL, MA)
00816
REVERE POWER (PROVIDENCE, RI)
00821
PINEHILLS METER - (PLYMOUTH, MA)
00824
NEW ENGLAND GAS COMPANY FALL RIVER GAS-NORTH FALL RIVER STA-(BRIST
00829
NATIONAL GRID-SANDWICH (BARNSTABLE, MA)
00839
NSTAR - ASSONET, BRISTOL CO, MA
80003
INTERCONNECT AGT G-10 LAT & CLEARY LATERAL
80004
INTERCONNECT AGT G-SYS BOURNE, MA & CANAL LATERAL
80047
LATERAL G SYSTEM CANAL MAINLINE
80049
LATERAL G SYSTEM CLEARY MAINLINE
80806
G-24 MAINLINE HEAD OF LATERAL
99825
FALL RIVER GAS
00020
MILFORD (WORCESTER, MA)
00021
NATIONAL GRID- NORWOOD (NORFOLK, MA)
00022
WESTWOOD (NORFOLK, MA)
00023
NATIONAL GRID- EAST BRAINTREE (NORFOLK, MA)
00024
BROCKTON (PLYMOUTH, MA)
00025
HOPEDALE (NORFOLK, MA)
00027
NATIONAL GRID- EVERETT (MIDDLESEX, MA)
00028
BROOKFORD ST (MIDDLESEX, MA)
00032
NATIONAL GRID-WALTHAM (MIDDLESEX, MA)
00036
WEST MEDWAY (NORFOLK, MA)
00038
CHARLES RIVER RD (NORFOLK, MA)
00043
ASHLAND (MIDDLESEX, MA)
00052
NATIONAL GRID-PONKAPOAG (NORFOLK, MA)
00057
NATIONAL GRID-WESTON (MIDDLESEX, MA)
00058
CANTON (NORFOLK, MA)
00061
WOODLAND RD (NORFOLK, MA)
00074
NATIONAL GRID-WELLESLEY (NORFOLK, MA)
00080
NATIONAL GRID-POLAROID (MIDDLESEX, MA)
00081
NATIONAL GRID-POTTER ST. (NORFOLK, MA)
00089
NATIONAL GRID-MEDFORD (MIDDLESEX, MA)
00094
BELLINGHAM (NORFOLK, MA)
00206
LINCOLN (MIDDLESEX, MA)
00215
SALEM ESSEX CO., MA (ESSEX, MA)
00230
MARATHON (MIDDLESEX, MA)
00271
EVERETT INT. (MIDDLESEX, MA)
00620
EXCELERATE ENERGY LP - EXCELERATE MS - (ESSEX, MA)
00621
EXCELERATE ENERGY LP - EXCELLENCE MS - (ESSEX, MA)
00622
EXCELERATE ENERGY LP - NE GATEWAY-EXPLORER (ESSEX, MA)
00624
EXCELERATE ENERGY LP - EXQUISITE (ESSEX, MA)
00625
EXCELERATE ENERGY LP - EXPEDIENT (ESSEX, MA)
00626
EXCELERATE ENERGY LP - EXEMPLAR (ESSEX, MA)
00630
SUEZ NEPTUNE LNG - (ESSEX, MA)
00631
SUEZ CAPE ANN, LNG - (ESSEX, MA)
00801
MILFORD POWER
00803
FORE RIVER (NORFOLK, MA)
00814
ANP BELLINGHAM ENERGY COMPANY (NORFOLK, MA)
00823
SHARON STATION- (NORFOLK, MA)
00826
MYSTIC (MIDDLESEX, MA)
00827
NATIONAL GRID-WEYMOUTH (NORFOLK, MA)
00830
MARATHON (MIDDLESEX, MA)
00832
NORFOLK METER STATION (NORFOLK, MA)
00834
BELD - BRAINTREE ELECTRIC LIGHT (NORFOLK, MA)
00837
SALEM HARBOR STATION
00838
NATIONAL GRID - WEST ROXBURY
00844
EXELON/CONSTELLATION ENERGY, NORFOLK CO., MA
01215
SALEM ESSEX CO., MA NORTH (ESSEX, MA)
02630
NEPTUNE LNG - (ESSEX, MA)
80012
LATERAL Y SYSTEM
80013
LATERAL Y SYSTEM MAINLINE
80022
LATERAL T SYSTEM
80023
LATERAL T SYSTEM MAINLINE
80042
Q-1 EXTENSION MAINLINE
80060
G-24 LATERAL HEAD OF LATERAL
80094
J-2 SYSTEM
80095
J-2 SYSTEM MAINLINE
80104
WEST ROXBURY LATERAL
80105
WEST ROXBURY LATERAL (MAINLINE)
80106
SALEM LATERAL (MAINLINE)
80107
SALEM LATERAL
80108
LINCOLN LATERAL (MAINLINE)
80109
LINCOLN LATERAL
88202
INTERCONNECTION BETWEEN NORTHEAST GATEWAY AND HUBLINE MAINLINE
88203
INTERCONNECTION BETWEEN NORTHEAST GATEWAY AND HUBLINE
88271
DISTRIGAS - EVERETT
89847
NORTHEAST GATEWAY DEEP WATER PORT (DWP1)
89848
INTERCONNECT BETWEEN SUEZ NEPTUNE AND HUBLINE
99817
EVERSOURCE GAS COMPANY OF MA
99818
BOS GAS CO D
99822
NSTAR
99837
DISTRIGAS LDC
99855
SALEM LATERAL CUSTODY TRANSFER POINT
99857
EAST BRAINTREE CUSTODY TRANSFER POINT
ANR Pipeline (TC Energy)

CAPACITY REDUCTION - Southeast Area – Patterson Compressor Station

SEV 3/5
Informational Until Further Notice

Pre-screen severity 3 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name ANR Pipeline Company
TSP 006958581
Notice Type Description: Maintenance

Notice Stat Desc: Initiate

Prior Notice: 

Critical: Y

Reqrd Rsp Desc: No Response Required
Post

Notice Effective

Notice End



Response
Post Date: 09/01/26

09/01/26

09/04/26
Subject: Subject: CAPACITY REDUCTION - Southeast Area – Patterson Compressor Station
Author: Author: Bryan Turner
Notice Text
ANR has maintenance in the Southeast Area at the Patterson Compressor Station located in Acadia Parish, Louisiana. As a result, capacity will be reduced as follows: 

 

9/3 – 9/3:

 

Patterson/Trunkline (LOC #40317): 82 MMcf/d (leaving 12 MMcf/d)

Patterson to Col Gulf (LOC #43613): 143 MMcf/d (leaving 0 MMcf/d)

Riverway (To Bridgeline) (LOC #42593): 70 MMcf/d (leaving 100 MMcf/d)

Avalon (LOC #38295): 85 MMcf/d (leaving 25 MMcf/d)

Shadyside/Sonat (Del) (LOC #10369): 281 MMcf/d (leaving 200 MMcf/d)

Shadyside/TGP (Del) (LOC #467240): 443 MMcf/d (leaving 30 MMcf/d)

St. Landry/FL Int (LOC #322625): 39 MMcf/d (leaving 60 MMcf/d)

Weeks ISLA/LIG PL (LOC #233620): 260 MMcf/d (leaving 50 MMcf/d)

 

ANR anticipates this posting may result in Firm Primary, Firm Secondary and Interruptible curtailments.

 

Any reservation charge credits (RCCs) will be determined per the process set forth in the General Terms and Conditions, Section 6.36 of ANR’s FERC Gas Tariff (“Tariff”). However, ANR will only issue RCCs if ANR is unable to schedule or deliver primary firm nominated capacity as a result of the outage. In the event RCCs are issued as set forth in the Tariff, shippers will receive RCCs based on its 7-day Non-Force Majeure Average Usage Quantity, as defined in Section 6.36.2 of ANR’s Tariff, less any scheduled quantities on the contract. By means of this notice, ANR is establishing which specific Gas Days will be included when determining a shipper’s 7-day Non-Force Majeure Average Usage Quantity pursuant to Section 6.36.2(b) of the Tariff.

 

Please direct any questions to your Account Coordinator, Customer Service Representative, or the Nominations and Scheduling hotline @ 800-827-5267
Kern River Gas Transmission

Kern River - Warning - Line Pack is Trending Low

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name: KERN RIVER GAS TRANSMISSION COMPANY
TSP DUNS: 621617372
Notice Identifier: 20260452
Prior Notice Identifier: 20260449
Notice Type:  Pipe Cond
Notice Status: 3
Posting Date: 09/05/2026 07:42
Notice Effective Date: 09/05/2026 07:42
Notice End Date: 09/20/2026 07:42
Subject: Kern River - Warning - Line Pack is Trending Low

Notice Text:
Services Portal > Informational Postings > Notices > Critical Skip to main content // // Menu Informational Postings Informational Postings Capacity Operationally Available Unsubscribed Capacity Allocation Log Gas Quality Gas Quality Report Gas Quality Methodology Gas Quality Tariff Provisions Biomethane Operating Policy Mojave Gas Quality Interconnect Party Gas Quality Index of Customers Locations Pooling Locations Notices Critical Non-Critical Planned Service Outage Request to Purchase Releasable Capacity Waste Heat Capacity Release Indices Posted Imbalances Regulatory Standards of Conduct Affiliate Names & Addresses Affiliate Tariff Waivers Chief Compliance Officer Employee Transfers Implementation Procedures Information Disclosure Job Titles & Descriptions Potential Mergers Shared Facilities Voluntary Consent Tariff Title Sheet/Section Table of Contents Preliminary Statement Map Currently Effective Rates Rate Schedules General Terms and Conditions Form of Service Agreement Entire Tariff Sheet/Section Index Transactional Reporting Firm Interruptible Capacity Release Maps System Map High Desert Lateral Wyoming Receipts Nevada Deliveries California Deliveries Utah Deliveries Downloads Search Customer Activities Site Map Customer Activities Nominations Nomination Confirmation Scheduled Quantity -Scheduled Quantity for Shipper -Scheduled Quantity for Operator -View Scheduling Results Flowing Gas Pre-determined Allocation Allocation -Shipper Imbalance -Allocation for Operator Imbalance -TSA Imbalance History -OBA Imbalance History -Shipper Imbalance Measurement -Measurement Information Netting and Trading -Net Imbal -Auth to Post Imbal -Post Imbal Dwnld -Imbal Trd Invoicing Invoice Payment Remittance Statement of Account Negotiated Rate Details Park and Loan Imbalance Rate Case Reports Capacity Release Offers Bids Awards Pre-approved Bidders List Recall Reput Contracts Agreement Request Contract Maintenance Pooling Contracts Transportation Sales Support -Contact Manager -Fuel and L&U Matrix -Hist Fuel and L&U Rates -Capacity Release Log -Contact Us -Notices -Tariff -Rapids Tips & Tricks Rapids Setup -New Customer Setup Form -Rapids Installation -Firewall Settings Informational Postings Site Map Transportation Sales News Announcements Presentations Customer Information Agreements and Forms FERC 809/NAESB 3.0 Info Miscellaneous Info Contact Us Contact List //PRN 15119 KevinH Refactor how the menu works, apply IE PDF preview overlay fix (function($){ $(document).ready(function(){ $('.accordion').each(function(index,value){ var parent = $(value).parent(); var parentId = index; if (!!parent.attr('id')) parentId = parent.attr('id').split('-')[2]; $(value).parent().attr('id','acc-parent-' + parentId); $(value).find('> .accordion-toggle' ).attr('data-target','#acc-body-' + index); $(value).find('> .accordion-body').attr('data-parent','#acc-parent-' + parentId).attr('href','#acc-body-' + index); }); $('.nav .accordion-toggle').on('click', function(event){ var target = $(event.target), parent = target.parent().parent(), parentId = parent.attr('id'); $('[data-parent*="#' + parentId + '"]').each(function(index,value){ if ( $(value).hasClass('in') ) { $(value).collapse('toggle'); } }); $('[href="' + target.attr('data-target') + '"]').collapse('toggle'); if (target.hasClass('collapsed')) { parent.find('.collapsed').removeClass('collapsed'); parent.find('.in').prev().addClass('collapsed'); } else { parent.find('.collapsed').removeClass('collapsed'); parent.find('.in').prev().addClass('collapsed'); target.addClass('collapsed'); } return false; }); if (window.navigator.userAgent.indexOf("MSIE ") > 0 || !!navigator.userAgent.match(/Trident.*rv\:11\./) && ($('.objectPDF').length > 0) ) { $('#navdttg').addClass('ie-pdf-fix'); $('.nav > .accordion').each(function(index,value){ $(value).append(' '); }); $('.nav > .accordion > .accordion-toggle').on('click', function (event) { var target = $(event.target); $('.ie-accordion-fix').removeClass('ie-accordion-fix'); if (target.hasClass('collapsed')) { $('.ie-accordion-fix').removeClass('ie-accordion-fix'); target.parent().addClass('ie-accordion-fix'); } else $('.ie-accordion-fix').removeClass('ie-accordion-fix'); }); function adjustHeight(event) { $('.ie-accordion-fix').height(function(){ return parseInt($('.ie-accordion-fix > .accordion-body').height()) + 20; }); $('html').animate({ scrollTop: 1 },20); } $('.accordion-toggle').on('click', function (event) { $('.ie-accordion-fix').off('shown'); $('.ie-accordion-fix .accordion').off('shown'); $('.ie-accordion-fix').on('shown', adjustHeight); $('.ie-accordion-fix .accordion').on('shown', adjustHeight); }); } }); })(jQuery); Launch Rapids A critical error has occurred. Please check the Event Viewer for further details. ©2026 Kern River Gas Transmission Company. All rights reserved.
North Baja Pipeline

MAINTENANCE SCHEDULE for North Baja (Posted: 9/3/26)

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Notice Category: Planned Service Outage
Notice Type: Plnd Outage
Notice Status: Supersede
Posting Date/Time: 09/03/2026 14:05
Notice Eff Date/Time: 09/03/2026 14:05
Prior Notice ID: 724

Subject: MAINTENANCE SCHEDULE for North Baja (Posted: 9/3/26)
Gas Transmission Northwest

MAINTENANCE SCHEDULE for Gas Transmission Northwest (Posted: 9/3/26)

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Notice Category: Planned Service Outage
Notice Type: Plnd Outage
Notice Status: Supersede
Posting Date/Time: 09/03/2026 14:00
Notice Eff Date/Time: 09/03/2026 14:00
Prior Notice ID: 1624

Subject: MAINTENANCE SCHEDULE for Gas Transmission Northwest (Posted: 9/3/26)
El Paso Natural Gas (EPNG)

[CAPACITY CONSTRAINT] Location Performance Update

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Pipeline: El Paso Natural Gas (EPNG)
Notice Type: CAPACITY CONSTRAINT
Subject: Location Performance Update
Posted: 09/09/2026 6:31:25PM
Effective: 09/09/2026 6:31:25PM
End Date: 09/10/2026 9:00:00AM

TSP/TSP Name:  8001703-EL PASO NATURAL GAS CO. L.L.C. Critical: Y
Notice Type Desc (1):  CAPACITY CONSTRAINT Notice Type Desc (2):  SEGMENTS
Notice Eff Date/Time:  09/09/2026 6:31:25PM Notice End Date/Time:  09/10/2026 9:00:00am
Post Date/Time:  9/9/2026 6:31:25 PM Notice ID: 629591
Reqrd Rsp:  1 Rsp Date/Time:  9/9/2026 12:00:00 AM
Notice Stat Desc:  SUPERSEDE Prior Notice:  629590
Subject:  Location Performance Update
Notice Text:
NOTICE TO CUSTOMERS
September 9, 2026
Location Performance Update
 
El Paso Natural Gas (EPNG) is concerned about the performance of the following location(s).  The following performance cap(s) will be placed:
Loc
 
Loc Name
 
Flow Dir
 
Zone
 
Segment
 
Pooling Area
 
County/State
 
Action
314548
 
IABBOTTD
 
Delivery
 
AZ-N
 
2020
 
PINAL,AZ
 
Cap C1 - 09/09/26 limit to 2,109 dths
This could result in underperformance (LOR) reductions to shipper and/or pooler nominations conducting business at this location(s).
 
The following location(s) have shown sufficient improvement and, therefore, will not have a performance cap for today's gas day.
Loc
 
Loc Name
 
Flow Dir
 
Zone
 
Segment
 
Pooling Area
 
County/State
 
Action
49444
 
IPELSPRI
 
Receipt
 
TX-P
 
940
 
WAHA
 
REEVES,TX
 
Watchlist Lift
 
 
For scheduling questions, call the Nominations and Scheduling representative or the Scheduling Hotline at 1-800-238-3764.
For Marketing assistance, call your Marketing representative.
 
Freddie Salas, Manager
Nominations and Scheduling
(719) 520-4238
Freddie_salas@kindermorgan.com
Texas Eastern Transmission (TETCO)

09/09/2026- TE Pipeline Conditions for 9/10/2026

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name: Texas Eastern Transmission, LP
Subject: TE Pipeline Conditions for 9/10/2026
Notice Type: Capacity Constraint
Critical Notice Description: Critical notice
Notice Status Description: Initiate
Notice Effective Date: 09/10/2026
Notice End Date: 09/11/2026
Posting Date: 09/09/2026
Notice Identifier: 182802
Required Response Indicator Description: No response required

For Gas Day September 10, 2026, Texas Eastern (TE) has approved and scheduled nominations at each pipeline segment and meter station up to TE's operational capacity. The following locations have been restricted due to requested nominations exceeding TE's operational capacity:
Restricted Locations
Scheduled and Sealed
Priority % Restricted
Notes
TABS
North of Berne
Meter 75919 Deliveries
N/A
100%
100%
83%
Rec from AGT & Del West of Lambertville
100%
100%
100%
Meter 73907 & 73706 Receipts
N/A
100%
100%
100%
62%
Planned Outage
TE/AGT Lease
Yes
To Lease Capacity
Nexus/TE Leased Meters
Yes
To Lease Capacity
30" South of Berne
Berne - Southbound
N/A
100%
100%
Danville - Southbound
N/A
100%
100%
Tompkinsville - Southbound
N/A
100%
100%
Barton - Southbound
N/A
100%
100%
24"
Sarahsville - Southbound
N/A
100%
100%
100%
100%
100%
Five Points - Southbound
N/A
100%
78%
Lebanon
N/A
100%
71%
Lebanon Lateral
N/A
100%
75%
Batesville - Southbound
N/A
100%
39%
Meter 74215 Deliveries
Yes
Access Area
Union Church - Southbound
N/A
100%
90%
New Roads South - Southbound
N/A
100%
95%
White Castle - Southbound
N/A
100%
95%
Longview - Northbound
N/A
100%
31%
Huntsville - Northbound
N/A
100%
Speaks - Southbound
N/A
100%
81%
Angleton West - Northbound
N/A
100%
46%
Vidor East - Northbound
Yes
Gillis - Northbound
N/A
100%
55%
TABS Pool Restrictions - Tolerances
ETX
STX
WLA
ELA
M1-24"
M1-30"
M2-24"
M2-30"
TABS Pool - Length
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
TABS Pool - Short
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
No-Notice Restrictions
OFO / Imbalance Notice
OFO
---
Action Alert
---
Customer Specific OFO
---
Imbalance Warnings
Stay Balanced - Access Area, M1-24, M1-30,M2-24, M2-30, and M3
FERC Order 698
M2-24, M2-30 and M3
Gas Quality:
Due to gas quality issues, meter 76609 has been shut in and physical receipts at the meter will be unavailable until further notice.  Beginning during the Timely cycle for Gas Day December 6, 2025, and until further notice, TE will restrict receipt nominations at Meter 76609 to -0- Dth/d.
Systemwide Notes:
Shippers in all Texas Eastern's Access Area Zones and Market Area Zones M1-30, M2-30 and M3 are required to coordinate any imbalance payback through TE's account representative and actual payback quantities may be limited depending on system operations and conditions. If customers do not adhere to imbalance requirements stated above, TE will utilize any provision of its tariff to ensure system integrity including the issuance of customer specific or system wide OFOs.
Please contact your Operations Account Representative should you have any questions.
Steckman Ridge

09/09/2026- SR Storage Conditions for 9/10/2026

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name: Steckman Ridge, LP
Subject: SR Storage Conditions for 9/10/2026
Notice Type: Capacity Constraint
Critical Notice Description: Critical notice
Notice Status Description: Initiate
Notice Effective Date: 09/10/2026
Notice End Date: 09/11/2026
Posting Date: 09/09/2026
Notice Identifier: 182808
Required Response Indicator Description: No response required

Notice Text:
The following restriction will be in place on the Steckman Ridge system for Gas Day September 10, 2026:
Steckman Ridge has restricted a portion of excess injections. No increases in injections will be accepted except to comply with NAESB bump guidelines.
Customers are advised that capacity may become available as the nomination and confirmation process continues throughout the day.
Please contact your Operations Account Representative if you have any questions.
NEXUS Gas Transmission (U.S.)

09/09/2026- NEXUS Pipeline Conditions for 9/10/2026

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name: NEXUS Gas Transmission, LLC (U.S.)
Subject: NEXUS Pipeline Conditions for 9/10/2026
Notice Type: Capacity Constraint
Critical Notice Description: Critical notice
Notice Status Description: Initiate
Notice Effective Date: 09/10/2026
Notice End Date: 09/11/2026
Posting Date: 09/09/2026
Notice Identifier: 182807
Required Response Indicator Description: No response required

For Gas Day September 10, 2026, Nexus Gas Transmission, LLC (NEXUS) has approved and scheduled nominations at each pipeline segment and meter station up to NEXUS's operational capacity. The following locations have been restricted due to requested nominations exceeding NEXUS's operational capacity:
Restricted Locations
Scheduled and Sealed
Priority % Restricted
Notes
TABS
Belle River
N/A
100%
100%
100%
100%
100%
100%
40%
Due to DTE Posted Outage
Ypsilanti
N/A
100%
100%
100%
100%
100%
100%
41%
Due to DTE Posted Outage
N4706 Receipts
N/A
100%
100%
100%
100%
100%
100%
18%
TE Planned Outage
OFO / Imbalance Notice
OFO
---
Customer Specific OFO
---
Imbalances Warnings
Stay Balanced
Systemwide Notes:
Customers are advised that capacity may become available as the nomination and confirmation process continues throughout the day.
Please contact your Operations Account Representative should you have any questions.
Egan Hub Storage

09/09/2026- Egan Storage Conditions for 9/10/2026

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name: Egan Hub Storage, LLC
Subject: Egan Storage Conditions for 9/10/2026
Notice Type: Capacity Constraint
Critical Notice Description: Critical notice
Notice Status Description: Initiate
Notice Effective Date: 09/10/2026
Notice End Date: 09/11/2026
Posting Date: 09/09/2026
Notice Identifier: 182809
Required Response Indicator Description: No response required

Notice Text:
Due to the previously posted planned outage, the following restriction will be in place on the Egan Hub Storage (Egan) system for Gas Day September 10, 2026:
Egan has scheduled and sealed injection nominations as well as IWS activity.  No increases in injections will be accepted except to comply with NAESB bump guidelines.
Egan has scheduled and sealed withdrawal nominations as well as IWS activity.  No increases in withdrawals will be accepted except to comply with NAESB bump guidelines.
Customers are advised that capacity may become available as the nomination and confirmation process continues throughout the day.
Please contact your Operations Account Representative if you have any questions.
Southeast Supply Header

09/09/2026- SESH Pipeline Conditions for 09/10/2026

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name: Southeast Supply Header, LLC
Subject: SESH Pipeline Conditions for 09/10/2026
Notice Type: Capacity Constraint
Critical Notice Description: Critical notice
Notice Status Description: Initiate
Notice Effective Date: 09/10/2026
Notice End Date: 09/11/2026
Posting Date: 09/09/2026
Notice Identifier: 182782
Required Response Indicator Description: No response required

For Gas Day September 10, 2026, Southeast Supply Header (SESH) has approved and scheduled nominations at each pipeline segment and meter station up to SESH's operational capacity. The following locations have been restricted due to requested nominations exceeding SESH's operational capacity:
Restricted Locations
Scheduled and Sealed
Priority % Restricted
Notes
Gwinville
100%
Gwinville East
100%
OFO / Imbalance Notice
OFO
---
Customer Specific OFO
---
Imbalances Warnings
No DP - System Wide
Systemwide Notes:
SESH has limited operational flexibility to manage imbalances. As a result, SESH requires all delivery point operators to keep actual daily takes out of the system equal to or less than scheduled quantities regardless of their cumulative imbalance position unless otherwise coordinated with your operations account representative.
Customers are advised that capacity may become available as the nomination and confirmation process continues throughout the day.
Please contact your Operations Account Representative should you have any questions.
Iroquois Gas Transmission

Capacity Constraint

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Critical Notice Effective Timely Cycle, Gas Day September 10, 2026, Iroquois nominations are at capacity and sealed from all increases for the following location(s): -       Brookfield Interconnect with Algonquin Gas Transmission. In addition, the following capacity has been reduced: -       Park, Interruptible and Secondary receipt nominations at the Brookfield Interconnect are reduced by 100%. Customers will be advised if further capacity becomes available during the day as volumes are nominated and confirmed. Please contact your account representative or Gas Control for further information. End date 09/11/2026 09:00 CCT
Gulf South Pipeline

Unplanned Index 296 Pipeline Maintenance

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Pipeline: Gulf South Pipeline
Notice ID: 5038659
Notice Type: Maintenance
Status: Supersede
Posted: 2026-09-02T11:57:00+00:00
Effective: 2026-09-02T12:00:00+00:00
End: 
Subject: Unplanned Index 296 Pipeline Maintenance
Gulf South Pipeline

Gulf South Inability to Take Confirmed Quantities on Index 296

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Pipeline: Gulf South Pipeline
Notice ID: 5038660
Notice Type: Over-Under Performance
Status: Initiate
Posted: 2026-09-02T12:04:00+00:00
Effective: 2026-09-02T12:05:00+00:00
End: 
Subject: Gulf South Inability to Take Confirmed Quantities on Index 296
Gulf South Pipeline

Posted Maintenance Events for 09/04/2026 - 09/10/2026

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Pipeline: Gulf South Pipeline
Notice ID: 5038658
Notice Type: Maintenance
Status: Initiate
Posted: 2026-09-02T11:05:00+00:00
Effective: 2026-09-04T09:00:00+00:00
End: 2026-09-11T09:00:00+00:00
Subject: Posted Maintenance Events for 09/04/2026 - 09/10/2026
Texas Gas Transmission

Maintenance - YVE

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Pipeline: Texas Gas Transmission
Notice ID: 5038655
Notice Type: Maintenance
Status: Initiate
Posted: 2026-09-02T10:30:00+00:00
Effective: 2026-09-09T09:00:00+00:00
End: 2026-09-17T09:00:00+00:00
Subject: Maintenance - YVE
Gulf South Pipeline

Gulf South Inability to Take Confirmed Quantities on Index 296

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Pipeline: Gulf South Pipeline
Notice ID: 5038687
Notice Type: Over-Under Performance
Status: Terminate
Posted: 2026-09-09T10:25:00+00:00
Effective: 2026-09-09T10:30:00+00:00
End: 2026-09-09T11:00:00+00:00
Subject: Gulf South Inability to Take Confirmed Quantities on Index 296 

Gulf South Pipeline Notice 5038687
Source Link
All information here is provided as a service and information is not guaranteed to be accurate. PipeRiv is not responsible for any incorrect information.
TSP Name :
Gulf South Pipeline Company, LLC
Category :
Critical
Notice Type Desc :
Over-Under Performance
Notice Stat Desc :
Terminate
Notice ID :
5038687
Prior Notice :
5038661
Reqrd Rsp Desc :
No response required
Subject :
Gulf South Inability to Take Confirmed Quantities on Index
TSP :
078444247
Post Date/Time :
09/09/2026 10:25:00 AM
Notice Effective Date/Time :
09/09/2026 10:30:00 AM
Notice End Date/Time :
09/09/2026 11:00:00 AM
Response Date/Time :
Critical :
Notice Text :
Gulf South Pipeline Company, LLC (“Gulf South”) has limited operational receipt flexibility on
Index 296 related to the "Unplanned Index 296 Pipeline Maintenance" (Notice I.D. 5038650).
As a result, effective ID1, September 2, 2026, the "Index 296 Receipts" scheduling group will be
reduced to 25,000 Dth/day until further notice. The following locations are included in the
"Index 296 Receipts" scheduling group and will be impacted:
• Discovery (SLN 21805)
• Louisiana Delta Farms (SLN 22537)
• Bully Camp (SLN 9154)
• Golden Meadow (SLN 45)
• Bully Camp (SLN 9694)
If you have any questions, please contact your customer service representative.
Notice
Page 1 of 1
09/09/2026 10:25:26 AM
Notice
TSP Name :
Gulf South Pipeline Company, LLC
TSP :
078444247
Category :
Critical
Post Date/Time :
09/09/2026 10:25:00 AM
Notice Type Desc :
Over-Under Performance
Notice Effective Date/Time :
09/09/2026 10:30:00 AM
Notice Stat Desc :
Terminate
Notice End Date/Time :
09/09/2026 11:00:00 AM
Notice ID :
5038687
Response Date/Time :
Prior Notice :
5038661
Critical :
Reqrd Rsp Desc :
No response required
Subject :
Gulf South Inability to Take Confirmed Quantities on Index
Notice Text :
Gulf South Pipeline Company, LLC (“Gulf South”) has limited operational receipt flexibility on
Index 296 related to the "Unplanned Index 296 Pipeline Maintenance" (Notice I.D. 5038650).
As a result, effective ID1, September 2, 2026, the "Index 296 Receipts" scheduling group will be
reduced to 25,000 Dth/day until further notice. The following locations are included in the
"Index 296 Receipts" scheduling group and will be impacted:
• Discovery (SLN 21805)
• Louisiana Delta Farms (SLN 22537)
• Bully Camp (SLN 9154)
• Golden Meadow (SLN 45)
• Bully Camp (SLN 9694)
If you have any questions, please contact your customer service representative.
09/09/2026 10:25:26 AM
Page 1 of 1
El Paso Natural Gas (EPNG)

[MAINTENANCE] Updated September 2026 Maintenance

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Pipeline: El Paso Natural Gas (EPNG)
Notice Type: MAINTENANCE
Subject: Updated September 2026 Maintenance
Posted: 09/09/2026 8:31:20AM
Effective: 09/09/2026 8:31:20AM
End Date: 09/10/2026 9:00:00AM

TSP/TSP Name:  8001703-EL PASO NATURAL GAS CO. L.L.C. Critical: Y
Notice Type Desc (1):  MAINTENANCE Notice Type Desc (2):  MAINTENANCE
Notice Eff Date/Time:  09/09/2026 8:31:20AM Notice End Date/Time:  09/10/2026 9:00:00am
Post Date/Time:  9/9/2026 8:31:20 AM Notice ID: 629587
Reqrd Rsp:  5 Rsp Date/Time: 
Notice Stat Desc:  SUPERSEDE Prior Notice:  629538
Subject:  Updated September 2026 Maintenance
Notice Text:
EPNG Maintenance Calendar
September 2026
Seg Area
 
Seg Nbr
 
Flow Dir
 
Location
 
Base Capacity (MDth)
 
Tue
1
 
Wed
2
 
Thu
3
 
Fri
4
 
Sat
5
 
Sun
6
 
Mon
7
 
Tue
8
 
Wed
9
 
Thu
10
 
Fri
11
 
Sat
12
 
Sun
13
 
Mon
14
 
Tue
15
 
Wed
16
 
Thu
17
 
Fri
18
 
Sat
19
 
Sun
20
 
Mon
21
 
Tue
22
 
Wed
23
 
Thu
24
 
Fri
25
 
Sat
26
 
Sun
27
 
Mon
28
 
Tue
29
 
Wed
30
Anadarko
 
690
 
F
 
PLAIN ST
 
756
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
 
 
 
 
 
% Seg Avail
 
756
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
Anadarko
 
715
 
B
 
PLAINS N
 
312
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
 
 
 
 
 
% Seg Avail
 
312
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
Anadarko
 
740
 
B
 
AMAR N
 
292
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
 
 
 
 
 
% Seg Avail
 
292
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
Anadarko
 
740
 
F
 
AMAR S
 
309
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
 
 
 
 
 
% Seg Avail
 
309
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
Anadarko
 
760
 
F
 
DUMAS S
 
310
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
37
 
37
 
37
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
% Seg Avail
 
310
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
88%
 
88%
 
88%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
Anadarko
 
780
 
B
 
DUMAS E
 
170
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
63
 
63
 
63
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
% Seg Avail
 
170
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
63%
 
63%
 
63%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
Lincoln Crossover
 
640
 
B
 
CAPROCK N
 
612
 
163
 
163
 
163
 
68
 
68
 
68
 
68
 
68
 
68
 
68
 
68
 
68
 
68
 
68
 
230
 
230
 
230
 
230
 
68
 
68
 
68
 
68
 
68
 
68
 
68
 
68
 
68
 
68
 
115
 
115
 
 
 
 
 
 
% Seg Avail
 
612
 
73%
 
73%
 
73%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
62%
 
62%
 
62%
 
62%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
81%
 
81%
Lincoln Crossover
 
645
 
B
 
LUSK
 
284
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
 
 
 
 
 
% Seg Avail
 
284
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
Line 1903
 
3000
 
F
 
MOJTHRU
 
463
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
117
 
117
 
117
 
117
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
% Seg Avail
 
463
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
75%
 
75%
 
75%
 
75%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
Mojave Seamless
 
3040
 
F
 
MOJAVE
 
400
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
54
 
54
 
54
 
54
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
% Seg Avail
 
400
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
87%
 
87%
 
87%
 
87%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
North Mainline
 
200
 
F
 
NORTH ML
 
2244
 
820
 
983
 
649
 
649
 
649
 
649
 
649
 
649
 
649
 
649
 
649
 
649
 
649
 
649
 
649
 
649
 
649
 
649
 
649
 
649
 
649
 
961
 
961
 
961
 
961
 
961
 
961
 
961
 
961
 
961
 
 
 
 
 
 
% Seg Avail
 
2244
 
63%
 
56%
 
71%
 
71%
 
71%
 
71%
 
71%
 
71%
 
71%
 
71%
 
71%
 
71%
 
71%
 
71%
 
71%
 
71%
 
71%
 
71%
 
71%
 
71%
 
71%
 
57%
 
57%
 
57%
 
57%
 
57%
 
57%
 
57%
 
57%
 
57%
Permian Virtual Segment
 
940
 
F
 
GUADLUP
 
1168
 
 
 
 
 
 
 
 
 
136
 
136
 
136
 
272
 
272
 
272
 
272
 
136
 
136
 
136
 
136
 
136
 
136
 
136
 
136
 
136
 
136
 
136
 
136
 
136
 
136
 
136
 
136
 
136
 
136
 
136
Permian Virtual Segment
 
940
 
F
 
KEYST ST
 
781
 
229
 
229
 
229
 
229
 
229
 
229
 
229
 
229
 
229
 
229
 
229
 
229
 
229
 
229
 
558
 
558
 
558
 
558
 
229
 
229
 
229
 
229
 
229
 
229
 
229
 
229
 
229
 
229
 
229
 
229
Permian Virtual Segment
 
940
 
F
 
KEYSTAFL
 
750
 
198
 
198
 
198
 
198
 
198
 
198
 
198
 
198
 
198
 
198
 
198
 
198
 
198
 
198
 
527
 
527
 
527
 
527
 
198
 
198
 
198
 
198
 
198
 
198
 
198
 
198
 
198
 
198
 
198
 
198
Permian Virtual Segment
 
940
 
F
 
L2000
 
608
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
130
 
130
 
0
 
0
 
0
 
0
 
0
 
0
 
0
Permian Virtual Segment
 
940
 
F
 
PECOS
 
1195
 
 
 
 
 
 
 
 
 
158
 
158
 
158
 
295
 
295
 
295
 
295
 
158
 
158
 
158
 
158
 
158
 
158
 
158
 
158
 
158
 
158
 
158
 
158
 
158
 
158
 
158
 
158
 
158
 
158
 
158
Permian Virtual Segment
 
940
 
F
 
PUC WAHA
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
Permian Virtual Segment
 
940
 
F
 
WA2CORN
 
734
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Permian Virtual Segment
 
940
 
 
 
314598 (IWARMONU)
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
 
 
 
 
 
% Seg Avail
 
85
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
Permian Virtual Segment
 
940
 
 
 
377034 (ITEXNEUN)
 
76
 
76
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
% Seg Avail
 
76
 
0%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
South Mainline
 
1600
 
F
 
CORN HPW
 
586
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
South Mainline
 
1600
 
F
 
CORN LPW
 
1175
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
191
 
191
South Mainline
 
1600
 
F
 
CORNL2K
 
581
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
106
 
106
 
0
 
0
 
0
 
0
 
0
 
0
 
0
South Mainline
 
1600
 
F
 
CORNTRN
 
150
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
% Seg Avail
 
2492
 
97%
 
97%
 
97%
 
97%
 
97%
 
97%
 
97%
 
97%
 
97%
 
97%
 
97%
 
97%
 
97%
 
97%
 
97%
 
97%
 
97%
 
97%
 
97%
 
97%
 
97%
 
93%
 
93%
 
97%
 
97%
 
97%
 
97%
 
97%
 
89%
 
89%
South Mainline
 
1675
 
F
 
EL PASO
 
1243
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
South Mainline
 
1675
 
F
 
ELPASO C
 
584
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
South Mainline
 
1675
 
F
 
ELPASO E
 
578
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
 
 
 
 
 
% Seg Avail
 
2405
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
South Mainline
 
1760
 
F
 
LORDS B
 
580
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
South Mainline
 
1760
 
F
 
LORDS C
 
574
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
103
 
103
 
0
 
0
 
0
 
0
 
0
 
0
 
0
South Mainline
 
1760
 
F
 
LORDSBRG
 
977
 
202
 
202
 
202
 
202
 
202
 
202
 
202
 
202
 
202
 
202
 
507
 
507
 
507
 
507
 
507
 
507
 
507
 
507
 
507
 
507
 
507
 
507
 
466
 
466
 
466
 
466
 
466
 
466
 
466
 
466
 
 
 
 
 
 
% Seg Avail
 
2131
 
87%
 
87%
 
87%
 
87%
 
87%
 
87%
 
87%
 
87%
 
87%
 
87%
 
73%
 
73%
 
73%
 
73%
 
73%
 
73%
 
73%
 
73%
 
73%
 
73%
 
73%
 
68%
 
70%
 
75%
 
75%
 
75%
 
75%
 
75%
 
75%
 
75%
South Mainline
 
1760
 
 
 
314563 (IPYRAMID)
 
50
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
50
 
50
 
50
 
50
 
50
 
50
 
50
 
50
 
50
 
50
 
50
 
50
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
% Seg Avail
 
50
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
South Mainline
 
1800
 
F
 
BOWIE
 
579
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
South Mainline
 
1800
 
F
 
CIMARRON
 
572
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
101
 
101
 
0
 
0
 
0
 
0
 
0
 
0
 
0
South Mainline
 
1800
 
F
 
DRAGOON
 
710
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
198
 
198
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
% Seg Avail
 
1861
 
96%
 
96%
 
96%
 
96%
 
96%
 
96%
 
96%
 
96%
 
96%
 
96%
 
96%
 
96%
 
96%
 
96%
 
96%
 
96%
 
96%
 
96%
 
96%
 
96%
 
96%
 
91%
 
91%
 
85%
 
85%
 
96%
 
96%
 
96%
 
96%
 
96%
Start Date
 
End Date
 
Region
 
Scheduling Location
 
Maintenance List
 
Base Capacity Dthd
 
Total Reduction Dthd
 
PLM Reduction Dthd
 
FMJ Reduction Dthd
 
Net Dthd
 
Update
09/01/26
 
09/01/26
 
NM
 
NORTH ML
 
Line 1201 pipeline remediation Window Rock to Navajo - Delayed
Williams C Station maintenance - Revised Capacity Impact Dth/d
Seligman C Station equipment failure repair - FMJ Reduction
 
                         2,244,804
 
                                 820,096
 
                                699,391
 
                               120,705
 
    1,424,708
 
09/02/26
 
09/02/26
 
NM
 
NORTH ML
 
Leupp Station maintenance - Revised Capacity Impact Dth/d
Line 1201 pipeline remediation Window Rock to Navajo - Delayed
Williams C Station maintenance - Revised Capacity Impact Dth/d
Seligman C Station equipment failure repair - FMJ Reduction
 
                         2,244,804
 
                                 983,554
 
                                862,849
 
                               120,705
 
    1,261,250
 
09/03/26
 
09/04/26
 
NM
 
NORTH ML
 
Line 1201 pipeline remediation Window Rock to Navajo - Delayed
Williams C Station maintenance - Revised Capacity Impact Dth/d
Seligman C Station equipment failure repair - Completed
 
                         2,244,804
 
                                 649,575
 
                                649,575
 
                                             -
 
    1,595,229
 
09/05/26
 
09/07/26
 
NM
 
NORTH ML
 
Williams C Station maintenance - Revised Capacity Impact Dth/d
 
                         2,244,804
 
                                 649,575
 
                                649,575
 
                                             -
 
    1,595,229
 
09/08/26
 
09/10/26
 
NM
 
NORTH ML
 
Line 1201 pipeline remediation Window Rock to Navajo - Delayed
Leupp 4A inspection
Williams C Station maintenance - Revised Capacity Impact Dth/d
 
                         2,244,804
 
                                 649,575
 
                                649,575
 
                                             -
 
    1,595,229
 
09/11/26
 
09/11/26
 
NM
 
NORTH ML
 
Line 1201 pipeline remediation Window Rock to Navajo - Delayed
Williams C Station maintenance - Revised Capacity Impact Dth/d
 
                         2,244,804
 
                                 649,575
 
                                649,575
 
                                             -
 
    1,595,229
 
09/12/26
 
09/21/26
 
NM
 
NORTH ML
 
Williams C Station maintenance - Revised Capacity Impact Dth/d
 
                         2,244,804
 
                                 649,575
 
                                649,575
 
                                             -
 
    1,595,229
 
09/22/26
 
09/28/26
 
NM
 
NORTH ML
 
Line 1201 pipeline remediation Window Rock to Navajo
Williams C Station maintenance - Revised Capacity Impact Dth/d
 
                         2,244,804
 
                                 961,356
 
                                961,356
 
                                             -
 
    1,283,448
 
09/29/26
 
09/30/26
 
NM
 
NORTH ML
 
Line 1201 pipeline remediation Window Rock to Navajo
Williams C Station maintenance - Revised Capacity Impact Dth/d
Window Rock 2A inspection
 
                         2,244,804
 
                                 961,356
 
                                961,356
 
                                             -
 
    1,283,448
 
09/15/26
 
09/16/26
 
MOJ
 
MOJTHRU
 
Mojave 1A inspection
 
                             463,000
 
                                 117,000
 
                                117,000
 
                                             -
 
        346,000
 
09/17/26
 
09/18/26
 
MOJ
 
MOJTHRU
 
Mojave 2A inspection
 
                             463,000
 
                                 117,000
 
                                117,000
 
                                             -
 
        346,000
 
09/15/26
 
09/16/26
 
MOJ
 
MOJAVE
 
Mojave 1A inspection
 
                             400,000
 
                                    54,000
 
                                  54,000
 
                                             -
 
        346,000
 
09/17/26
 
09/18/26
 
MOJ
 
MOJAVE
 
Mojave 2A inspection
 
                             400,000
 
                                    54,000
 
                                  54,000
 
                                             -
 
        346,000
 
09/01/26
 
09/03/26
 
XO
 
CAPROCK N
 
Caprock 2A equipment failure repair - FMJ Reduction
Lincoln Station maintenance
 
                             612,700
 
                                 163,132
 
                                  94,752
 
                                  68,380
 
        449,568
 
09/04/26
 
09/14/26
 
XO
 
CAPROCK N
 
Caprock 2A equipment failure repair - FMJ Reduction
 
                             612,700
 
                                    68,380
 
                                              -
 
                                  68,380
 
        544,320
 
09/15/26
 
09/18/26
 
XO
 
CAPROCK N
 
Caprock 2A equipment failure repair - FMJ Reduction
Bluewater Station DOT/ESD Tests
 
                             612,700
 
                                 230,668
 
                                162,288
 
                                  68,380
 
        382,032
 
09/19/26
 
09/28/26
 
XO
 
CAPROCK N
 
Caprock 2A equipment failure repair - FMJ Reduction
 
                             612,700
 
                                    68,380
 
                                              -
 
                                  68,380
 
        544,320
 
09/29/26
 
09/30/26
 
XO
 
CAPROCK N
 
Caprock 2A equipment failure repair - FMJ Reduction
Line 1301 cleaning and smart tools Belen to Laguna
 
                             612,700
 
                                 115,756
 
                                  47,376
 
                                  68,380
 
        496,944
 
09/01/26
 
09/30/26
 
XO
 
LUSK
 
Caprock 2A equipment failure repair - FMJ Reduction
 
                             284,900
 
                                    22,350
 
                                              -
 
                                  22,350
 
        262,550
 
09/01/26
 
09/30/26
 
AN
 
PLAINS N
 
Line No. 1102 anomaly repairs Plains to Dimmit - MLV 16 to MLV 14 - FMJ Reduction
 
                             312,900
 
                                 112,900
 
                                              -
 
                               112,900
 
        200,000
 
09/01/26
 
09/06/26
 
AN
 
AMAR N
 
Amarillo 2A equipment failure repair - FMJ Reduction
Dimmitt 5A maintenance
 
                             292,400
 
                                    33,328
 
                                              -
 
                                  33,328
 
        259,072
 
09/07/26
 
09/30/26
 
AN
 
AMAR N
 
Amarillo 2A equipment failure repair - FMJ Reduction
 
                             292,400
 
                                    33,328
 
                                              -
 
                                  33,328
 
        259,072
 
09/01/26
 
09/06/26
 
AN
 
AMAR S
 
Amarillo 2A equipment failure repair - FMJ Reduction
Dimmitt 5A maintenance
Line No. 1102 anomaly repairs Plains to Dimmit - MLV 16 to MLV 14 - FMJ Reduction
 
                             309,500
 
                                    53,853
 
                                              -
 
                                  53,853
 
        255,647
 
09/07/26
 
09/30/26
 
AN
 
AMAR S
 
Amarillo 2A equipment failure repair - FMJ Reduction
Line No. 1102 anomaly repairs Plains to Dimmit - MLV 16 to MLV 14 - FMJ Reduction
 
                             309,500
 
                                    53,853
 
                                              -
 
                                  53,853
 
        255,647
 
09/22/26
 
09/24/26
 
AN
 
DUMAS E
 
Dumas Station DOT/ESD Tests
 
                             170,000
 
                                    63,290
 
                                  63,290
 
                                             -
 
        106,710
 
09/22/26
 
09/24/26
 
AN
 
DUMAS S
 
Dumas Station DOT/ESD Tests
 
                             310,500
 
                                    37,734
 
                                  37,734
 
                                             -
 
        272,766
 
09/01/26
 
09/30/26
 
PR
 
PLAIN ST
 
Plains 7A repair
Plains 8A repair
Plains 11A repair
Plains 13A repair
Plains 14A repair
Plains 15A repair
Plains Station equipment failure repair - FMJ Reduction
 
                             756,100
 
                                 405,923
 
                                              -
 
                               405,923
 
        350,177
 
09/01/26
 
09/01/26
 
PR
 
377034
 
Texaco Eunice Receipt - (ITEXNEUN) - Eunice 3C inspection - Customer reduced to zero Dth/d during this outage
 
                               76,545
 
                                    76,545
 
                                  76,545
 
                                             -
 
                      -
 
09/01/26
 
09/30/26
 
PR
 
314598
 
Monument A Station equipment failure repair - Warren Monument Receipt (IWARMONU) - Customer to zero Dth/d during Monument A Station mechanical failure repair - FMJ Reduction
 
                               85,739
 
                                    85,739
 
                                              -
 
                                  85,739
 
                      -
 
09/01/26
 
09/14/26
 
PR
 
KEYST ST
 
Keystone 4A repair
Keystone 11A repair
Keystone 1B repair
Keystone 2B repair
 
                             781,000
 
                                 229,021
 
                                229,021
 
                                             -
 
        551,979
 
09/15/26
 
09/18/26
 
PR
 
KEYST ST
 
Keystone 4A repair
Keystone 11A repair
Keystone 1B repair
Keystone 2B repair
Keystone Station DOT/ESD Tests
 
                             781,000
 
                                 558,151
 
                                558,151
 
                                             -
 
        222,849
 
09/19/26
 
09/30/26
 
PR
 
KEYST ST
 
Keystone 4A repair
Keystone 11A repair
Keystone 1B repair
Keystone 2B repair
 
                             781,000
 
                                 229,021
 
                                229,021
 
                                             -
 
        551,979
 
09/01/26
 
09/14/26
 
PR
 
KEYSTAFL
 
Keystone 4A repair
Keystone 11A repair
Keystone 1B repair
Keystone 2B repair
 
                             750,400
 
                                 198,391
 
                                198,391
 
                                             -
 
        552,009
 
09/15/26
 
09/18/26
 
PR
 
KEYSTAFL
 
Keystone Station DOT/ESD Tests
 
                             750,400
 
                                 527,538
 
                                527,538
 
                                             -
 
        222,862
 
09/19/26
 
09/30/26
 
PR
 
KEYSTAFL
 
Keystone 4A repair
Keystone 11A repair
Keystone 1B repair
Keystone 2B repair
 
                             750,400
 
                                 198,391
 
                                198,391
 
                                             -
 
        552,009
 
09/01/26
 
09/30/26
 
PR
 
PUC WAHA
 
Puckett Station equipment failure repair - FMJ Reduction
 
                             130,900
 
                                 130,900
 
                                              -
 
                               130,900
 
                      -
 
09/05/26
 
09/07/26
 
PR
 
PECOS
 
Line No.1103 anomaly repairs Pecos River to Guadalupe - FMJ Reduction
 
                         1,195,600
 
                                 158,838
 
                                              -
 
                               158,838
 
    1,036,762
 
09/08/26
 
09/11/26
 
PR
 
PECOS
 
Pecos River Station DOT/ESD Tests
Line No.1103 anomaly repairs Pecos River to Guadalupe - FMJ Reduction
 
                         1,195,600
 
                                 295,605
 
                                136,767
 
                               158,838
 
        899,995
 
09/12/26
 
09/30/26
 
PR
 
PECOS
 
Line No.1103 anomaly repairs Pecos River to Guadalupe - FMJ Reduction
 
                         1,195,600
 
                                 158,838
 
                                              -
 
                               158,838
 
    1,036,762
 
09/05/26
 
09/07/26
 
PR
 
GUADLUP
 
Line No.1103 anomaly repairs Pecos River to Guadalupe - FMJ Reduction
 
                         1,168,300
 
                                 136,461
 
                                              -
 
                               136,461
 
    1,031,839
 
09/08/26
 
09/11/26
 
PR
 
GUADLUP
 
Pecos River Station DOT/ESD Tests
Line No.1103 anomaly repairs Pecos River to Guadalupe - FMJ Reduction
 
                         1,168,300
 
                                 272,841
 
                                136,380
 
                               136,461
 
        895,459
 
09/12/26
 
09/30/26
 
PR
 
GUADLUP
 
Line No.1103 anomaly repairs Pecos River to Guadalupe - FMJ Reduction
 
                         1,168,300
 
                                 136,461
 
                                              -
 
                               136,461
 
    1,031,839
 
09/15/26
 
09/28/26
 
SM
 
CORN LPW
 
Cornudas 3A maintenance - Cancelled
 
                         1,175,500
 
                                               -
 
                                              -
 
                                             -
 
    1,175,500
 
09/29/26
 
09/30/26
 
SM
 
CORN LPW
 
Cornudas 3A maintenance - Cancelled
Hueco Station DOT/ESD Tests
 
                         1,175,500
 
                                 191,169
 
                                191,169
 
                                             -
 
        984,331
 
09/01/26
 
09/07/26
 
SM
 
LORDSBRG
 
Line 1103 pipeline remediation Lordsburg to San Simon - Delayed
San Simon Station equipment failure repair - FMJ Reduction - Revised Capacity Impact Dth/d
 
                             977,700
 
                                 202,515
 
                                              -
 
                               202,515
 
        775,185
 
09/08/26
 
09/10/26
 
SM
 
LORDSBRG
 
Line 1103 pipeline remediation Lordsburg to San Simon - Rescheduled
San Simon Station equipment failure repair - FMJ Reduction - Revised Capacity Impact Dth/d
 
                             977,700
 
                                 202,515
 
                                              -
 
                               202,515
 
        775,185
 
09/11/26
 
09/13/26
 
SM
 
LORDSBRG
 
Line 1103 pipeline remediation Lordsburg to San Simon - MLV 41.5 to MLV 43
Line 1103 pipeline remediation Lordsburg to San Simon MLV 43 to MLV 44.25
San Simon Station equipment failure repair - FMJ Reduction - Revised Capacity Impact Dth/d
 
                             977,700
 
                                 507,074
 
                                304,559
 
                               202,515
 
        470,626
 
Update
09/14/26
 
09/22/26
 
SM
 
LORDSBRG
 
Line 1103 pipeline remediation Lordsburg to San Simon - MLV 41.5 to MLV 43
Line 1103 pipeline remediation Lordsburg to San Simon MLV 43 to MLV 44.25
San Simon Station equipment failure repair - FMJ Reduction - Revised Capacity Impact Dth/d
 
                             977,700
 
                                 507,074
 
                                304,559
 
                               202,515
 
        470,626
 
Update
09/23/26
 
09/27/26
 
SM
 
LORDSBRG
 
Line 1103 pipeline remediation Lordsburg to San Simon MLV 43 to MLV 44.25
San Simon Station equipment failure repair - FMJ Reduction - Revised Capacity Impact Dth/d
 
                             977,700
 
                                 466,663
 
                                264,148
 
                               202,515
 
        511,037
 
Update
09/28/26
 
09/29/26
 
SM
 
LORDSBRG
 
Line 1103 pipeline remediation Lordsburg to San Simon MLV 43 to MLV 44.25
San Simon Station equipment failure repair - FMJ Reduction - Revised Capacity Impact Dth/d
 
                             977,700
 
                                 466,663
 
                                264,148
 
                               202,515
 
        511,037
 
Update
09/30/26
 
09/30/26
 
SM
 
LORDSBRG
 
Line 1103 pipeline remediation Lordsburg to San Simon MLV 43 to MLV 44.25
San Simon Station equipment failure repair - FMJ Reduction - Revised Capacity Impact Dth/d
San Simon Station maintenance - Cancelled
 
                             977,700
 
                                 466,663
 
                                264,148
 
                               202,515
 
        511,037
 
Update
09/11/26
 
09/22/26
 
SM
 
314563
 
Tri-State Pyramid Generating Delivery - (IPYRAMID) - Customer reduced to zero Dth/d net capacity during Line 1103 pipeline remediation Lordsburg to San Simon - MLV 41.5 to MLV 43 - Outage coordinated with customer
 
                               50,784
 
                                    50,784
 
                                  50,784
 
                                             -
 
                      -
 
09/24/26
 
09/25/26
 
SM
 
DRAGOON
 
Dragoon Station inspection
 
                             710,200
 
                                 198,027
 
                                198,027
 
                                             -
 
        512,173
 
09/01/26
 
09/30/26
 
PR
 
WA2CORN
 
Gresham Station mechanical failure repair - FMJ Reduction
 
                             734,400
 
                                    67,738
 
                                              -
 
                                  67,738
 
        666,662
 
09/01/26
 
09/03/26
 
SM
 
CORN HPW
 
Lordsburg 1B maintenance
Gresham Station mechanical failure repair - FMJ Reduction
 
                             586,300
 
                                    76,968
 
                                     9,230
 
                                  67,738
 
        509,332
 
09/04/26
 
09/30/26
 
SM
 
CORN HPW
 
Lordsburg 1B maintenance
Gresham Station mechanical failure repair - FMJ Reduction
 
                             586,300
 
                                    76,968
 
                                     9,230
 
                                  67,738
 
        509,332
 
09/01/26
 
09/03/26
 
SM
 
LORDS B
 
Lordsburg 1B maintenance
Gresham Station mechanical failure repair - FMJ Reduction
 
                             580,900
 
                                    75,298
 
                                     7,560
 
                                  67,738
 
        505,602
 
09/04/26
 
09/30/26
 
SM
 
LORDS B
 
Lordsburg 1B maintenance
Gresham Station mechanical failure repair - FMJ Reduction
 
                             580,900
 
                                    75,298
 
                                     7,560
 
                                  67,738
 
        505,602
 
09/01/26
 
09/03/26
 
SM
 
BOWIE
 
Lordsburg 1B maintenance
Gresham Station mechanical failure repair - FMJ Reduction
 
                             579,000
 
                                    75,259
 
                                     7,521
 
                                  67,738
 
        503,741
 
09/04/26
 
09/30/26
 
SM
 
BOWIE
 
Lordsburg 1B maintenance
Gresham Station mechanical failure repair - FMJ Reduction
 
                             579,000
 
                                    75,259
 
                                     7,521
 
                                  67,738
 
        503,741
 
09/01/26
 
09/21/26
 
PR
 
L2000
 
El Paso 4D equipment failure repair - Completed
 
                             608,300
 
                                               -
 
                                              -
 
                                             -
 
        608,300
 
09/22/26
 
09/23/26
 
PR
 
L2000
 
El Paso 4D equipment failure repair - Completed
Cimarron Station inspection
 
                             608,300
 
                                 130,539
 
                                130,539
 
                                             -
 
        477,761
 
09/24/26
 
09/30/26
 
PR
 
L2000
 
El Paso 4D equipment failure repair - Completed
 
                             608,300
 
                                               -
 
                                              -
 
                                             -
 
        608,300
 
09/01/26
 
09/21/26
 
SM
 
CORNL2K
 
El Paso 4D equipment failure repair - Completed
 
                             581,200
 
                                               -
 
                                              -
 
                                             -
 
        581,200
 
09/22/26
 
09/23/26
 
SM
 
CORNL2K
 
El Paso 4D equipment failure repair - Completed
Cimarron Station inspection
 
                             581,200
 
                                 106,195
 
                                106,195
 
                                             -
 
        475,005
 
09/24/26
 
09/30/26
 
SM
 
CORNL2K
 
El Paso 4D equipment failure repair - Completed
 
                             581,200
 
                                               -
 
                                              -
 
                                             -
 
        581,200
 
09/01/26
 
09/30/26
 
SM
 
ELPASO E
 
El Paso 4D equipment failure repair - Completed
 
                             578,900
 
                                               -
 
                                              -
 
                                             -
 
        578,900
 
09/01/26
 
09/21/26
 
SM
 
LORDS C
 
El Paso 4D equipment failure repair - Completed
 
                             574,400
 
                                               -
 
                                              -
 
                                             -
 
        574,400
 
09/22/26
 
09/23/26
 
SM
 
LORDS C
 
El Paso 4D equipment failure repair - Completed
Cimarron Station inspection
 
                             574,400
 
                                 103,774
 
                                103,774
 
                                             -
 
        470,626
 
09/24/26
 
09/30/26
 
SM
 
LORDS C
 
El Paso 4D equipment failure repair - Completed
 
                             574,400
 
                                               -
 
                                              -
 
                                             -
 
        574,400
 
09/01/26
 
09/21/26
 
SM
 
CIMARRON
 
El Paso 4D equipment failure repair - Completed
 
                             572,200
 
                                               -
 
                                              -
 
                                             -
 
        572,200
 
09/22/26
 
09/23/26
 
SM
 
CIMARRON
 
El Paso 4D equipment failure repair - Completed
Cimarron Station inspection
 
                             572,200
 
                                 101,574
 
                                101,574
 
                                             -
 
        470,626
 
09/24/26
 
09/30/26
 
SM
 
CIMARRON
 
El Paso 4D equipment failure repair - Completed
 
                             572,200
 
                                               -
 
                                              -
 
                                             -
 
        572,200
 
In addition to planned outages, this report reflects the repairs and maintenance being performed related to Force Majeure events.
Due to the nature of such events, the dates for the associated repairs and maintenance of those events are assumed to extend until the end of the month.
These repairs and maintenance, however, may extend beyond the end of the month including beyond the current year.
More information on these repairs and maintenance will be posted as a Critical Notice under the Notices section of the Informational Postings tab on the EPNG Electronic Bulletin Board.
Kern River Gas Transmission

Kern River - Warning - Line Pack is Low

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name: KERN RIVER GAS TRANSMISSION COMPANY
TSP DUNS: 621617372
Notice Identifier: 20260458
Prior Notice Identifier: 20260452
Notice Type:  Pipe Cond
Notice Status: 2
Posting Date: 09/09/2026 07:28
Notice Effective Date: 09/09/2026 07:28
Notice End Date: 09/24/2026 07:28
Subject: Kern River - Warning - Line Pack is Low

Notice Text:
--------------------------------
TSP Name: KERN RIVER GAS TRANSMISSION COMPANY
TSP: 621617372
Critical Notice Indicator: Y
Notice Status: 2
Notice Type: Pipeline Conditions
Posting Date: 09/09/2026
Posting Time: 07:28 AM
Notice Effective Date: 09/09/2026
Notice Effective Time: 07:28 AM
Notice End Date: 09/24/2026
Notice End Time: 07:28 AM
Notice Identifier: 20260458
Prior Notice Identifier: 20260452
Required Response Indicator: 5
Response Date: N/A
Response Time: N/A
Subject: Kern River - Warning - Line Pack is Low
--------------------------------
Notice Text:
(1) Line pack is low and threatening Kern River's operation.
(2) All shipper and delivery point operators should align daily scheduled nominations and physical
receipts and deliveries.
(3) All prior drafting balancing arrangements have been terminated.
(4) Kern River may take corrective action to increase line pack by limiting physical flow at delivery points
where a draft imbalance was created during prior gas day(s).
Important information is posted to Kern River's Daily Operational Report page at
https://services.kernrivergas.com.
Contact your Marketing & Customer Services representative or the Customer Services hotline at 801-
937-6111 if you have questions.
Thank you for your cooperation.
Florida Gas Transmission

[Florida Gas Transmission] [Operational Alert] Overage Alert Day 25% Tolerance

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Pipeline: Florida Gas Transmission
Notice ID: 68680
Notice Type: Operational Alert
Subject: Overage Alert Day 25% Tolerance
Posted: Sep 9 2026 6:56 AM
Effective: Sep 9 2026 9:00 AM
End Date: Sep 10 2026 9:00 AM

Notice ID: 68680
Notice Type: Operational Alert
Critical: Y
Notice Status Description: Initiate
Reqrd Rsp Desc: No Response Required
Posting Date/Time: Sep 9 2026 6:56 AM
Subject: Overage Alert Day 25% Tolerance
Notice Effective Date/Time: Sep 9 2026 9:00 AM
Notice End Date/Time: Sep 10 2026 9:00 AM
Notice Text: Mid 90-degree temperatures are forecasted in Florida over the next several days; therefore, for the gas day of September 09, 2026, FGT would like to notify their customers in the FGT Market Area that it is issuing an Overage Alert Day at 25% (Twenty Five Percent) tolerance.For the gas day of September 09, 2026, FGT will not interrupt previously scheduled Market Area ITS-1 service below the elapsed prorated scheduled quantity.FGT will continue to monitor hourly and daily takes. Please closely monitor your scheduled point quantities versus actual burn point quantities.
National Fuel Gas Supply

Ellisburg Station Outage: September 2026 - Revision 2

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Pipeline: National Fuel Gas Supply
Notice Type: Curtailment, Planned Service Outage, Scheduling Alert
Subject: Ellisburg Station Outage: September 2026 - Revision 2
Posted Date/Time: 09/01/2026 2:24:00PM CDT
Effective Date/Time: 09/08/2026 9:00:00AM CDT
End Date/Time: 09/14/2026 9:00:00AM CDT
Gulf South Pipeline

Meter Maintenance - Third Party Pipeline Notice (00052)

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Pipeline: Gulf South Pipeline
Notice ID: 5038649
Notice Type: Maintenance
Status: Initiate
Posted: 2026-09-01T11:35:00+00:00
Effective: 2026-10-05T09:00:00+00:00
End: 2026-11-16T09:00:00+00:00
Subject: Meter Maintenance - Third Party Pipeline Notice (00052)
Gulf South Pipeline

Unplanned Index 266-L Pipeline Maintenance

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Pipeline: Gulf South Pipeline
Notice ID: 5038651
Notice Type: Maintenance
Status: Initiate
Posted: 2026-09-01T11:41:00+00:00
Effective: 2026-09-02T09:00:00+00:00
End: 
Subject: Unplanned Index 266-L Pipeline Maintenance
Gulf South Pipeline

Carthage #2 Compressor Station Maintenance

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Pipeline: Gulf South Pipeline
Notice ID: 5038652
Notice Type: Maintenance
Status: Initiate
Posted: 2026-09-01T15:34:00+00:00
Effective: 2026-09-01T15:40:00+00:00
End: 2026-09-29T09:00:00+00:00
Subject: Carthage #2 Compressor Station Maintenance
Gulf South Pipeline

Failure to Deliver Confirmed Quantities at Location 464

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Pipeline: Gulf South Pipeline
Notice ID: 5038685
Notice Type: Over-Under Performance
Status: Terminate
Posted: 2026-09-08T19:37:00+00:00
Effective: 2026-09-08T19:38:00+00:00
End: 2026-09-09T09:00:00+00:00
Subject:  Failure to Deliver Confirmed Quantities at Location 464

Gulf South Pipeline Notice 5038685
Source Link
All information here is provided as a service and information is not guaranteed to be accurate. PipeRiv is not responsible for any incorrect information.
TSP Name :
Gulf South Pipeline Company, LLC
Category :
Critical
Notice Type Desc :
Over-Under Performance
Notice Stat Desc :
Terminate
Notice ID :
5038685
Prior Notice :
5038680
Reqrd Rsp Desc :
No response required
Subject :
Failure to Deliver Confirmed Quantities at Location 464
TSP :
078444247
Post Date/Time :
09/08/2026 07:37:00 PM
Notice Effective Date/Time :
09/08/2026 07:38:00 PM
Notice End Date/Time :
09/09/2026 09:00:00 AM
Response Date/Time :
Critical :
Notice Text :
Due to Customer’s failure to Deliver confirmed quantities at the locations noted below, Gulf
South Pipeline Company, LLC (“Gulf South”) is notifying customers that it anticipates scheduling
reductions for the remaining nomination cycles for Gas Day 9/2/2026 and until further notice
based upon Projected Daily Quantities* at these locations.
464 Targa Venice
Gulf South continues to monitor this issue and will confirm and schedule nomination cycles
pursuant to the nomination timeline.
“Projected Daily Quantities” is the greater of the Elapsed Prorated Scheduled Quantity or the
Accumulated Measured Quantity plus the Estimated Measured Quantity for the balance of the Gas
Day.  “Accumulated Measured Quantity” is defined as the measured quantities through the location
since the beginning of the Gas Day.  The “Estimated Measured Quantity” is the number of hours
remaining in the Gas Day multiplied by the 30-minute average of the current flow rate divided by
24 hours.
If you have any questions, please contact your customer service representative.
Notice
Page 1 of 1
09/08/2026 7:37:18 PM
Notice
TSP Name :
Gulf South Pipeline Company, LLC
TSP :
078444247
Category :
Critical
Post Date/Time :
09/08/2026 07:37:00 PM
Notice Type Desc :
Over-Under Performance
Notice Effective Date/Time :
09/08/2026 07:38:00 PM
Notice Stat Desc :
Terminate
Notice End Date/Time :
09/09/2026 09:00:00 AM
Notice ID :
5038685
Response Date/Time :
Prior Notice :
5038680
Critical :
Reqrd Rsp Desc :
No response required
Subject :
Failure to Deliver Confirmed Quantities at Location 464
Notice Text :
Due to Customer’s failure to Deliver confirmed quantities at the locations noted below, Gulf
South Pipeline Company, LLC (“Gulf South”) is notifying customers that it anticipates scheduling
reductions for the remaining nomination cycles for Gas Day 9/2/2026 and until further notice
based upon Projected Daily Quantities* at these locations.
464 Targa Venice
Gulf South continues to monitor this issue and will confirm and schedule nomination cycles
pursuant to the nomination timeline.
“Projected Daily Quantities” is the greater of the Elapsed Prorated Scheduled Quantity or the
Accumulated Measured Quantity plus the Estimated Measured Quantity for the balance of the Gas
Day.  “Accumulated Measured Quantity” is defined as the measured quantities through the location
since the beginning of the Gas Day.  The “Estimated Measured Quantity” is the number of hours
remaining in the Gas Day multiplied by the 30-minute average of the current flow rate divided by
24 hours.
If you have any questions, please contact your customer service representative.
09/08/2026 7:37:18 PM
Page 1 of 1
Southeast Supply Header

09/08/2026- SESH Pipeline Conditions for 9/9/2026

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name: Southeast Supply Header, LLC
Subject: SESH Pipeline Conditions for 9/9/2026
Notice Type: Capacity Constraint
Critical Notice Description: Critical notice
Notice Status Description: Initiate
Notice Effective Date: 09/09/2026
Notice End Date: 09/10/2026
Posting Date: 09/08/2026
Notice Identifier: 182720
Required Response Indicator Description: No response required

For Gas Day September 9, 2026, Southeast Supply Header (SESH) has approved and scheduled nominations at each pipeline segment and meter station up to SESH's operational capacity. The following locations have been restricted due to requested nominations exceeding SESH's operational capacity:
Restricted Locations
Scheduled and Sealed
Priority % Restricted
Notes
Gwinville
100%
Gwinville East
100%
OFO / Imbalance Notice
OFO
---
Customer Specific OFO
---
Imbalances Warnings
No DP - System Wide
Systemwide Notes:
SESH has limited operational flexibility to manage imbalances. As a result, SESH requires all delivery point operators to keep actual daily takes out of the system equal to or less than scheduled quantities regardless of their cumulative imbalance position unless otherwise coordinated with your operations account representative.
Customers are advised that capacity may become available as the nomination and confirmation process continues throughout the day.
Please contact your Operations Account Representative should you have any questions.
NEXUS Gas Transmission (U.S.)

09/08/2026- NEXUS Pipeline Conditions for 9/9/2026

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name: NEXUS Gas Transmission, LLC (U.S.)
Subject: NEXUS Pipeline Conditions for 9/9/2026
Notice Type: Capacity Constraint
Critical Notice Description: Critical notice
Notice Status Description: Initiate
Notice Effective Date: 09/09/2026
Notice End Date: 09/10/2026
Posting Date: 09/08/2026
Notice Identifier: 182719
Required Response Indicator Description: No response required

For Gas Day September 9, 2026, Nexus Gas Transmission, LLC (NEXUS) has approved and scheduled nominations at each pipeline segment and meter station up to NEXUS's operational capacity. The following locations have been restricted due to requested nominations exceeding NEXUS's operational capacity:
Restricted Locations
Scheduled and Sealed
Priority % Restricted
Notes
TABS
Belle River
N/A
100%
100%
100%
100%
100%
100%
40%
Due to DTE Posted Outage
Ypsilanti
N/A
100%
100%
100%
100%
100%
100%
38%
Due to DTE Posted Outage
OFO / Imbalance Notice
OFO
---
Customer Specific OFO
---
Imbalances Warnings
Stay Balanced
Systemwide Notes:
Customers are advised that capacity may become available as the nomination and confirmation process continues throughout the day.
Please contact your Operations Account Representative should you have any questions.
Egan Hub Storage

09/08/2026- Egan Storage Conditions for 9/9/2026

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name: Egan Hub Storage, LLC
Subject: Egan Storage Conditions for 9/9/2026
Notice Type: Capacity Constraint
Critical Notice Description: Critical notice
Notice Status Description: Initiate
Notice Effective Date: 09/09/2026
Notice End Date: 09/10/2026
Posting Date: 09/08/2026
Notice Identifier: 182723
Required Response Indicator Description: No response required

Notice Text:
Due to the previously posted planned outage, the following restriction will be in place on the Egan Hub Storage (Egan) for Gas Day September 9, 2026:
Egan has restricted excess injections and IWS activity.  No increases in injections or IWS activity will be accepted except to comply with NAESB bump guidelines.
Egan has restricted the portion of secondary withdrawal nominations.  No increases in withdrawals will be accepted except to comply with NAESB bump guidelines.
Customers are advised that capacity may become available as the nomination and confirmation process continues throughout the day.
Please contact your Operations Account Representative if you have any questions.
Gulf South Pipeline

Failure to Deliver Confirmed Quantities at Location 464

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Pipeline: Gulf South Pipeline
Notice ID: 5038680
Notice Type: Over-Under Performance
Status: Initiate
Posted: 2026-09-08T15:51:00+00:00
Effective: 2026-09-08T15:53:00+00:00
End: 2026-09-09T09:00:00+00:00
Subject:  Failure to Deliver Confirmed Quantities at Location 464

Gulf South Pipeline Notice 5038680
Source Link
All information here is provided as a service and information is not guaranteed to be accurate. PipeRiv is not responsible for any incorrect information.
TSP Name :
Gulf South Pipeline Company, LLC
Category :
Critical
Notice Type Desc :
Over-Under Performance
Notice Stat Desc :
Initiate
Notice ID :
5038680
Prior Notice :
Reqrd Rsp Desc :
No response required
Subject :
Failure to Deliver Confirmed Quantities at Location 464
TSP :
078444247
Post Date/Time :
09/08/2026 03:51:00 PM
Notice Effective Date/Time :
09/08/2026 03:53:00 PM
Notice End Date/Time :
09/09/2026 09:00:00 AM
Response Date/Time :
Critical :
Notice Text :
Due to Customer’s failure to Deliver confirmed quantities at the locations noted below, Gulf
South Pipeline Company, LLC (“Gulf South”) is notifying customers that it anticipates scheduling
reductions for the remaining nomination cycles for Gas Day 9/2/2026 and until further notice
based upon Projected Daily Quantities* at these locations.
464 Targa Venice
Gulf South continues to monitor this issue and will confirm and schedule nomination cycles
pursuant to the nomination timeline.
“Projected Daily Quantities” is the greater of the Elapsed Prorated Scheduled Quantity or the
Accumulated Measured Quantity plus the Estimated Measured Quantity for the balance of the Gas
Day.  “Accumulated Measured Quantity” is defined as the measured quantities through the location
since the beginning of the Gas Day.  The “Estimated Measured Quantity” is the number of hours
remaining in the Gas Day multiplied by the 30-minute average of the current flow rate divided by
24 hours.
If you have any questions, please contact your customer service representative.
Notice
Page 1 of 1
09/08/2026 3:51:55 PM
Notice
TSP Name :
Gulf South Pipeline Company, LLC
TSP :
078444247
Category :
Critical
Post Date/Time :
09/08/2026 03:51:00 PM
Notice Type Desc :
Over-Under Performance
Notice Effective Date/Time :
09/08/2026 03:53:00 PM
Notice Stat Desc :
Initiate
Notice End Date/Time :
09/09/2026 09:00:00 AM
Notice ID :
5038680
Response Date/Time :
Prior Notice :
Critical :
Reqrd Rsp Desc :
No response required
Subject :
Failure to Deliver Confirmed Quantities at Location 464
Notice Text :
Due to Customer’s failure to Deliver confirmed quantities at the locations noted below, Gulf
South Pipeline Company, LLC (“Gulf South”) is notifying customers that it anticipates scheduling
reductions for the remaining nomination cycles for Gas Day 9/2/2026 and until further notice
based upon Projected Daily Quantities* at these locations.
464 Targa Venice
Gulf South continues to monitor this issue and will confirm and schedule nomination cycles
pursuant to the nomination timeline.
“Projected Daily Quantities” is the greater of the Elapsed Prorated Scheduled Quantity or the
Accumulated Measured Quantity plus the Estimated Measured Quantity for the balance of the Gas
Day.  “Accumulated Measured Quantity” is defined as the measured quantities through the location
since the beginning of the Gas Day.  The “Estimated Measured Quantity” is the number of hours
remaining in the Gas Day multiplied by the 30-minute average of the current flow rate divided by
24 hours.
If you have any questions, please contact your customer service representative.
09/08/2026 3:51:55 PM
Page 1 of 1
Gulf South Pipeline

Harrisville Compressor Station Maintenance

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Pipeline: Gulf South Pipeline
Notice ID: 5038681
Notice Type: Maintenance
Status: Initiate
Posted: 2026-09-08T15:57:00+00:00
Effective: 2026-10-08T09:00:00+00:00
End: 2026-10-09T09:00:00+00:00
Subject: Harrisville Compressor Station Maintenance

Gulf South Pipeline Notice 5038681
Source Link
All information here is provided as a service and information is not guaranteed to be accurate. PipeRiv is not responsible for any incorrect information.
TSP Name :
Gulf South Pipeline Company, LLC
Category :
Critical
Notice Type Desc :
Maintenance
Notice Stat Desc :
Initiate
Notice ID :
5038681
Prior Notice :
Reqrd Rsp Desc :
No response required
Subject :
Harrisville Compressor Station Maintenance
TSP :
078444247
Post Date/Time :
09/08/2026 03:57:00 PM
Notice Effective Date/Time :
10/08/2026 09:00:00 AM
Notice End Date/Time :
10/09/2026 09:00:00 AM
Response Date/Time :
Critical :
Notice Text :
Expansion Area 19 Scheduling Group
Capacity could be impacted by as much as 100,000 dth/d for the duration of the maintenance.
This maintenance has the potential to impact all services, including Primary Firm Service.
Demand charge credits will not be issued during the maintenance period unless Primary Firm
Service is scheduled down during the Timely Nomination Cycle. Any demand charge credits will be
calculated pursuant to Section 6.25 of the General Terms and Conditions of Gulf South`s NGA Gas
Tariff.
If you have any questions, please contact your customer service representative.
Notice
Page 1 of 1
09/08/2026 3:58:36 PM
Notice
TSP Name :
Gulf South Pipeline Company, LLC
TSP :
078444247
Category :
Critical
Post Date/Time :
09/08/2026 03:57:00 PM
Notice Type Desc :
Maintenance
Notice Effective Date/Time :
10/08/2026 09:00:00 AM
Notice Stat Desc :
Initiate
Notice End Date/Time :
10/09/2026 09:00:00 AM
Notice ID :
5038681
Response Date/Time :
Prior Notice :
Critical :
Reqrd Rsp Desc :
No response required
Subject :
Harrisville Compressor Station Maintenance
Notice Text :
Expansion Area 19 Scheduling Group
Capacity could be impacted by as much as 100,000 dth/d for the duration of the maintenance.
This maintenance has the potential to impact all services, including Primary Firm Service.
Demand charge credits will not be issued during the maintenance period unless Primary Firm
Service is scheduled down during the Timely Nomination Cycle. Any demand charge credits will be
calculated pursuant to Section 6.25 of the General Terms and Conditions of Gulf South`s NGA Gas
Tariff.
If you have any questions, please contact your customer service representative.
09/08/2026 3:58:36 PM
Page 1 of 1
Gulf South Pipeline

Index 818 Meter Maintenance

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Pipeline: Gulf South Pipeline
Notice ID: 5038682
Notice Type: Maintenance
Status: Initiate
Posted: 2026-09-08T16:07:00+00:00
Effective: 2026-10-10T16:30:00+00:00
End: 2026-10-26T00:00:00+00:00
Subject: Index 818 Meter Maintenance

Gulf South Pipeline Notice 5038682
Source Link
All information here is provided as a service and information is not guaranteed to be accurate. PipeRiv is not responsible for any incorrect information.
TSP Name :
Gulf South Pipeline Company, LLC
Category :
Critical
Notice Type Desc :
Maintenance
Notice Stat Desc :
Initiate
Notice ID :
5038682
Prior Notice :
Reqrd Rsp Desc :
No response required
Subject :
Index 818 Meter Maintenance
TSP :
078444247
Post Date/Time :
09/08/2026 04:07:00 PM
Notice Effective Date/Time :
10/10/2026 04:30:00 PM
Notice End Date/Time :
10/26/2026 12:00:00 AM
Response Date/Time :
Critical :
Notice Text :
The following point will be shut-in for the duration of the maintenance:
- Loc 24504 (Nextera (Lowman) Choctaw County)
This maintenance has the potential to impact all services, including Primary Firm Service.
Demand charge credits will not be issued during the maintenance period unless Primary Firm
Service is scheduled down during the Timely Nomination Cycle. Any demand charge credits will be
calculated pursuant to Section 6.25 of the General Terms and Conditions of Gulf South`s NGA Gas
Tariff.
If you have any questions, please contact your customer service representative.
Notice
Page 1 of 1
09/08/2026 4:07:39 PM
Notice
TSP Name :
Gulf South Pipeline Company, LLC
TSP :
078444247
Category :
Critical
Post Date/Time :
09/08/2026 04:07:00 PM
Notice Type Desc :
Maintenance
Notice Effective Date/Time :
10/10/2026 04:30:00 PM
Notice Stat Desc :
Initiate
Notice End Date/Time :
10/26/2026 12:00:00 AM
Notice ID :
5038682
Response Date/Time :
Prior Notice :
Critical :
Reqrd Rsp Desc :
No response required
Subject :
Index 818 Meter Maintenance
Notice Text :
The following point will be shut-in for the duration of the maintenance:
- Loc 24504 (Nextera (Lowman) Choctaw County)
This maintenance has the potential to impact all services, including Primary Firm Service.
Demand charge credits will not be issued during the maintenance period unless Primary Firm
Service is scheduled down during the Timely Nomination Cycle. Any demand charge credits will be
calculated pursuant to Section 6.25 of the General Terms and Conditions of Gulf South`s NGA Gas
Tariff.
If you have any questions, please contact your customer service representative.
09/08/2026 4:07:39 PM
Page 1 of 1
Gulf South Pipeline

Tallulah Compressor Station Maintenance

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Pipeline: Gulf South Pipeline
Notice ID: 5038683
Notice Type: Maintenance
Status: Initiate
Posted: 2026-09-08T16:11:00+00:00
Effective: 2026-10-19T00:00:00+00:00
End: 2026-10-24T00:00:00+00:00
Subject: Tallulah Compressor Station Maintenance

Gulf South Pipeline Notice 5038683
Source Link
All information here is provided as a service and information is not guaranteed to be accurate. PipeRiv is not responsible for any incorrect information.
TSP Name :
Gulf South Pipeline Company, LLC
Category :
Critical
Notice Type Desc :
Maintenance
Notice Stat Desc :
Initiate
Notice ID :
5038683
Prior Notice :
Reqrd Rsp Desc :
No response required
Subject :
Tallulah Compressor Station Maintenance
TSP :
078444247
Post Date/Time :
09/08/2026 04:11:00 PM
Notice Effective Date/Time :
10/19/2026 12:00:00 AM
Notice End Date/Time :
10/24/2026 12:00:00 AM
Response Date/Time :
Critical :
Notice Text :
Expansion Upstream Tallulah Receipt Scheduling Group
Capacity could be impacted by as much as 575,000 dth/d for the duration of the maintenance. This
maintenance has the potential to impact all services, including Primary Firm Service.
Demand charge credits will not be issued during the maintenance period unless Primary Firm
Service is scheduled down during the Timely Nomination Cycle. Any demand charge credits will be
calculated pursuant to Section 6.25 of the General Terms and Conditions of Gulf South`s NGA Gas
Tariff.
If you have any questions, please contact your customer service representative.
Notice
Page 1 of 1
09/08/2026 4:12:03 PM
Notice
TSP Name :
Gulf South Pipeline Company, LLC
TSP :
078444247
Category :
Critical
Post Date/Time :
09/08/2026 04:11:00 PM
Notice Type Desc :
Maintenance
Notice Effective Date/Time :
10/19/2026 12:00:00 AM
Notice Stat Desc :
Initiate
Notice End Date/Time :
10/24/2026 12:00:00 AM
Notice ID :
5038683
Response Date/Time :
Prior Notice :
Critical :
Reqrd Rsp Desc :
No response required
Subject :
Tallulah Compressor Station Maintenance
Notice Text :
Expansion Upstream Tallulah Receipt Scheduling Group
Capacity could be impacted by as much as 575,000 dth/d for the duration of the maintenance. This
maintenance has the potential to impact all services, including Primary Firm Service.
Demand charge credits will not be issued during the maintenance period unless Primary Firm
Service is scheduled down during the Timely Nomination Cycle. Any demand charge credits will be
calculated pursuant to Section 6.25 of the General Terms and Conditions of Gulf South`s NGA Gas
Tariff.
If you have any questions, please contact your customer service representative.
09/08/2026 4:12:03 PM
Page 1 of 1
Gulf South Pipeline

Heidelberg Compressor Station Maintenance

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Pipeline: Gulf South Pipeline
Notice ID: 5038684
Notice Type: Maintenance
Status: Supersede
Posted: 2026-09-08T16:18:00+00:00
Effective: 2026-09-28T09:00:00+00:00
End: 2026-10-03T09:00:00+00:00
Subject: Heidelberg Compressor Station Maintenance

Gulf South Pipeline Notice 5038684
Source Link
All information here is provided as a service and information is not guaranteed to be accurate. PipeRiv is not responsible for any incorrect information.
TSP Name :
Gulf South Pipeline Company, LLC
Category :
Critical
Notice Type Desc :
Maintenance
Notice Stat Desc :
Supersede
Notice ID :
5038684
Prior Notice :
5038434
Reqrd Rsp Desc :
No response required
Subject :
Heidelberg Compressor Station Maintenance
TSP :
078444247
Post Date/Time :
09/08/2026 04:18:00 PM
Notice Effective Date/Time :
09/28/2026 09:00:00 AM
Notice End Date/Time :
10/03/2026 09:00:00 AM
Response Date/Time :
Critical :
Notice Text :
Gulf South is performing maintenance at Heidelberg Compressor Station.
The following locations are subject to impact:
- Loc 23373 (Transco (Petal Pipeline))
- Loc 23370 (Transco Hattiesburg)
Combined receipt capacity between Location 23373 and Location 23370 will be limited to 125,000
This maintenance has the potential to impact all services, including Primary Firm Service.
Demand charge credits will not be issued during the maintenance period unless Primary Firm
Service is scheduled down during the Timely Nomination Cycle. Any demand charge credits will be
calculated pursuant to Section 6.25 of the General Terms and Conditions of Gulf South`s NGA Gas
Tariff.
Notice
Page 1 of 1
09/08/2026 4:18:25 PM
Notice
TSP Name :
Gulf South Pipeline Company, LLC
TSP :
078444247
Category :
Critical
Post Date/Time :
09/08/2026 04:18:00 PM
Notice Type Desc :
Maintenance
Notice Effective Date/Time :
09/28/2026 09:00:00 AM
Notice Stat Desc :
Supersede
Notice End Date/Time :
10/03/2026 09:00:00 AM
Notice ID :
5038684
Response Date/Time :
Prior Notice :
5038434
Critical :
Reqrd Rsp Desc :
No response required
Subject :
Heidelberg Compressor Station Maintenance
Notice Text :
Gulf South is performing maintenance at Heidelberg Compressor Station.
The following locations are subject to impact:
- Loc 23373 (Transco (Petal Pipeline))
- Loc 23370 (Transco Hattiesburg)
Combined receipt capacity between Location 23373 and Location 23370 will be limited to 125,000
This maintenance has the potential to impact all services, including Primary Firm Service.
Demand charge credits will not be issued during the maintenance period unless Primary Firm
Service is scheduled down during the Timely Nomination Cycle. Any demand charge credits will be
calculated pursuant to Section 6.25 of the General Terms and Conditions of Gulf South`s NGA Gas
Tariff.
09/08/2026 4:18:25 PM
Page 1 of 1
Steckman Ridge

09/08/2026- SR Storage Conditions for 09/09/2026

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name: Steckman Ridge, LP
Subject: SR Storage Conditions for 09/09/2026
Notice Type: Capacity Constraint
Critical Notice Description: Critical notice
Notice Status Description: Initiate
Notice Effective Date: 09/09/2026
Notice End Date: 09/10/2026
Posting Date: 09/08/2026
Notice Identifier: 182701
Required Response Indicator Description: No response required

Notice Text:
The following restriction will be in place on the Steckman Ridge system for Gas Day September 9, 2026:
Steckman Ridge has restricted a portion of excess injections. No increases in injections will be accepted except to comply with NAESB bump guidelines.
Customers are advised that capacity may become available as the nomination and confirmation process continues throughout the day.
Please contact your Operations Account Representative if you have any questions.
Algonquin Gas Transmission

09/08/2026- AGT Pipeline Conditions for 09/09/2026

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name: Algonquin Gas Transmission, LLC
Subject: AGT Pipeline Conditions for 09/09/2026
Notice Type: Capacity Constraint
Critical Notice Description: Critical notice
Notice Status Description: Initiate
Notice Effective Date: 09/09/2026
Notice End Date: 09/10/2026
Posting Date: 09/08/2026
Notice Identifier: 182702
Required Response Indicator Description: No response required

For Gas Day September 9, 2026, Algonquin Gas Transmission (AGT) has approved and scheduled nominations at each pipeline segment and meter station up to AGT's operational capacity. The following locations have been restricted due to requested nominations exceeding AGT's operational capacity:
Restricted Locations
Scheduled and Sealed
Priority % Restricted
Notes
Stony Point
100%
100%
100%
100%
100%
100%
100%
13%
Planned Outage
Cromwell
100%
100%
74%
Burrillville
100%
100%
61%
Weymouth
100%
100%
80%
Iroquois Deliveries
100%
100%
75%
Iroquois Receipts
100%
100%
54%
Hanover West
100%
100%
94%
Mendon Receipts
100%
100%
100%
100%
100%
58%
Lincoln Receipts
100%
100%
74%
Lincoln Deliveries
100%
100%
100%
G System
100%
100%
46%
C System
Yes
Centerville-Transco Receipts (1)
100%
100%
15%
I-8 West to East
Yes
No-Notice Restrictions
---
OFO / Imbalance Notice
System Wide OFO
---
Customer Specific OFO
---
Meter Specific OFO
---
Customer Specific Hourly OFO
---
Imbalances Warnings
Stay Balanced
FERC Order 698
Yes
Systemwide Notes:
(1) AGT has scheduled Transco Centerville receipts to the design meter capacity of 222,526 Dth/d.
AGT requests that customers/point operators on AGT be aware of the impact non-ratable hourly takes from the system may have in causing delivery pressures reaching lower than desired levels.
AGT's system is not designed to sustain delivery pressures above contract levels while making non-ratable/accelerated deliveries above scheduled quantities for more than 6 consecutive hours, to be followed by flows below scheduled quantity for the balance of any 24-hour period. If customers/point operators don't manage hourly takes from the system, 1) delivery pressures will be impacted and /or 2) AGT may be required to impose further restrictions or courses of action in order to maintain the operational integrity of the system.
AGT may be required to issue system specific, meter specific and/or hourly OFO's pursuant to General Terms and Conditions Section 26.7(d) to impose further restrictions in order to maintain the operational integrity of the system.
Customers are advised that capacity may become available as the nomination and confirmation process continues throughout the day.
Please contact your Operations Account Representative should you have any questions.
Tennessee Gas Pipeline (TGP)

Special Permit Extension 329-1 Valve Can

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Interstate
Other
Midstream
Informational Postings
Capacity
Gas Electric Coordination
Gas Quality
Index of Customers
Locations
Notices
Posted Imbalances
Regulatory
Standards of Conduct
Tariff
Transactional Reporting
Info Lookup
Other
Downloads
Search
Customer Activities
Site Map
	
	
NOTICE DETAIL
	
PDF
TEXT
Return To Results
TSP/TSP Name:  1939164-TENNESSEE GAS PIPELINE	Critical: Y
Notice Type Desc (1):  MAINTENANCE	Notice Type Desc (2):  MAINTENANCE
Notice Eff Date/Time:  09/08/2026 2:20:25PM	Notice End Date/Time:  09/09/2026 9:00:00am
Post Date/Time:  9/8/2026 2:20:25 PM	Notice ID: 404068
Reqrd Rsp:  1	Rsp Date/Time:  9/8/2026 12:00:00 AM
Notice Stat Desc:  INITIATE	Prior Notice: 
Subject:  Special Permit Extension 329-1 Valve Can
Notice Text:

Project Updates

 

“***MLV 117-3 to MLV 118-3:  Special Permit Pipe Replacement

--8/18/26 through 9/12/26:  This project will require taking the pipeline section out of service which could limit throughput and result in restrictions based on customer nominations. 

***

Date Change, Previously scheduled 8/18/26 to 9/11/26.

………………………………

 

***MLV 119-2 to MLV 119-2A:  Special Permit Pipe Replacement

--8/18/26 through 9/12/26:  This project will require taking the pipeline section out of service which could limit throughput and result in restrictions based on customer nominations. 

***

Date Change, Previously scheduled 8/18/26 to 9/11/26.

………………………………

 

***MLV 329AS-1 to MLV 329AD-1:  Valve Replacement - MLV 329-1
--CANCELLED:  This project will require taking the pipeline section out of service which could limit throughput and result in restrictions based on customer nominations.  The meters listed may be constrained or shut in during the project. 
420226 PSEG/TGP RAMSEY NJ BERGEN
***
Date Change, Previously scheduled 9/9/26 to 10/9/26.
………………………………

”

 

 

If you have any questions, please contact your Scheduler.

..
Iroquois Gas Transmission

Capacity Constraint

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Capacity Constraint Effective Timely Cycle, Gas Day September 9, 2026, nominations are sealed from all increases through the following locations: - Brookfield Interconnect with Algonquin Gas Transmission. In addition, the following capacity has been reduced: - Brookfield Interconnect – Park, Interruptible and Secondary receipt nominations are reduced by 100%. If you have any further questions, please contact the Iroquois Scheduling or Gas Control Group. End date 09/10/2026 09:00 AM CCT
Tres Palacios Gas Storage

09/08/2026- TPGS Storage Conditions for 9/8/2026 -- INTRADAY

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name: Tres Palacios Gas Storage LLC
Subject: TPGS Storage Conditions for 9/8/2026 -- INTRADAY
Notice Type: Capacity Constraint
Critical Notice Description: Critical notice
Notice Status Description: Initiate
Notice Effective Date: 09/08/2026
Notice End Date: 09/09/2026
Posting Date: 09/08/2026
Notice Identifier: 182693
Required Response Indicator Description: No response required

Notice Text:
Due to intraday nomination changes for Gas Day September 8, 2026, the following restrictions will be in place on the Tres Palacios Gas Storage, LLC (TPGS) system for Gas Day September 8, 2026:
Tres Palacios has scheduled and sealed withdrawal nominations and IWS activity at meter 45307 - FLORIDA GAS TRANSMISSION (TPGS1080B).  No increases in withdrawals or IWS activity will be accepted.
Customers are advised that capacity may become available as the nomination and confirmation process continues throughout the day.
Please contact your Operations Account Representative if you have any questions.
Southern Star

Operational Capacity Reduction - Line Segment 385 Updated

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name: Southern Star
Notice ID: 11215
Notice Type: Capacity Constraint
Status: Supersede
Post Date: 2026-09-08T09:08:21.73
Effective Begin: 2026-09-08T09:08:21.73
Effective End: None
Subject: Operational Capacity Reduction - Line Segment 385 Updated

Southern Star Central Gas Pipeline (Southern Star) has updated the capacity reduction on Line Segment 385 due to extreme heat and pipeline conditions. The following customers will be impacted: 60,000 dth/d NGPL Carter (location:17069) effective ID 1 cycle on 9/8/2026.
We appreciate your assistance during this matter and if you have any questions, please feel free to contact your Customer Service Representative.
Scott Warren Cell: 270.302.6433
Buster Ashley Cell: 270.314.1436
Easton Russelburg Cell: 270.302.0173
Columbia Gas Transmission (TCO)

UPDATE: Line SM-80 Pipeline Maintenance (CEREWEST), Effective September 10-26, 2026

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name Columbia Gas Transmission, LLC
TSP 054748041
Notice Type Description: Maintenance

Notice Stat Desc: Supersede

Prior Notice: 26196010

Critical: Y

Reqrd Rsp Desc: No Response Required
Post

Notice Effective

Notice End



Response
Post Date: 09/08/26

09/08/26

10/08/26
Subject: Subject: UPDATE: Line SM-80 Pipeline Maintenance (CEREWEST), Effective September 10-26, 2026
Author: Author: Dillon Schoolcraft
Notice Text
Columbia Gas Transmission, LLC (TCO) notifies customers of upcoming maintenance on Line SM-80 Loop in West Virginia beginning Thursday, September 10, 2026, and continuing through September 26, 2026. During the maintenance, TCO will utilize the temporary internal constraint Ceredo West MA19 (CEREWEST), which has been enabled in TC eConnects (Notice ID 26196010).

Based on forecasted operating conditions, TCO currently anticipates CEREWEST will be restricted to zero non-firm effective Timely Cycle for Thursday, Gas Day September 10, 2026, and continuing until further notice.

TCO reminds customers it may become necessary to reduce the capacity through CEREWEST to a level as low as 1,400,000 Dth Total Capacity (zero non-firm). TCO encourages customers to reference the Daily Capacity Posting for the specific capacity through CEREWEST each day during the maintenance.

Reservation charge credits (RCCs) will be determined per the process set forth in the General Terms and Conditions, Section 38 of TCO’s FERC Gas Tariff (“Tariff”). However, TCO will only issue RCCs if TCO is unable to schedule or deliver primary firm nominated capacity as a result of the outage. In the event RCCs are issued as set forth in the Tariff, shippers will receive RCCs based on its 7-day average usage quantity less any scheduled quantities on the contract.

Please contact your Customer Services Representative with any questions.

***Previous Posting***

Columbia Gas Transmission, LLC (TCO) notifies customers of upcoming pipeline maintenance on Line SM-80 in West Virginia scheduled to begin on Wednesday, September 9, 2026, through Saturday, September 26, 2026. During the maintenance, TCO will be utilizing the temporary internal constraint Ceredo West MA19 (CEREWEST).

Due to the utilization of CEREWEST, TCO has configured the temporary constraint in TC eConnects. This will allow customers to view CEREWEST on the Internal Constraint Rights screen, as well as the Operationally Available Capacity screen on Informational Postings. 

Based on forecasted operating conditions during the maintenance, TCO does not currently anticipate any reduction to firm nominations through CEREWEST. However, based on operating conditions, including the logistics involved with the performance of work, it may become necessary to reduce the capacity through CEREWEST to a level as low as 1,400,000 Dth Total Capacity (zero non-firm).

Customers are encouraged to monitor the Construction and Maintenance Schedule for any non-firm impacts and the Daily Capacity Posting for specific capacity settings each day of the outage.

Reservation charge credits (RCCs) will be determined per the process set forth in the General Terms and Conditions, Section 38 of TCO’s FERC Gas Tariff (“Tariff”). However, TCO will only issue RCCs if TCO is unable to schedule or deliver primary firm nominated capacity as a result of the outage. In the event RCCs are issued as set forth in the Tariff, shippers will receive RCCs based on its 7-day average usage quantity less any scheduled quantities on the contract. By means of this notice, TCO is establishing which specific Gas Days will be included when determining a shipper’s 7-day average usage quantity pursuant to the provisions in the Tariff.

Please contact your Customer Services Representative with any questions.
Enable Gas Transmission (EGT)

[Enable Gas Transmission (EGT)] [Maintenance] SOUTH POOL INTEGRITY DIGS TERM

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Pipeline: Enable Gas Transmission (EGT)
Notice ID: 6541
Notice Type: Maintenance
Subject: SOUTH POOL INTEGRITY DIGS TERM
Posted: Tue Sep 08 08:28:00 CDT 2026
Effective: Tue Sep 08 09:00:00 CDT 2026
End Date: 

EGT Critical Notices
TSP:                                     872670161
TSP Name:                                ENABLE GAS TRANSMISSION, LLC
Critical Notice Description:             Critical notice
Notice Effective Date:                   09/08/2026
Notice Effective Time:                   09:00
Notice End Date:                         00/00/0000
Notice End Time:                         00:00
Notice Identifier:                       6541
Notice Status Description:               Initiate
Notice Type:                             Maintenance
Posting Date/Time:                       09/08/2026 08:28
Required Response Indicator Description: No response required
Response Date:
Response Time:
Subject:                                 SOUTH POOL INTEGRITY DIGS TERM
Notice Text:
New Information Posted 9/8/26:
EGT South Pool Integrity Digs (Critical Notice #6478) is terminated effective Tuesday, September 8th,
2026 at 9:00 AM.
Previous Information Posted 7/16/26:
This Operational Alert is being issued pursuant to Section 20, GT&C of EGT s Tariff to notify all parties of
planned maintenance in EGT s South Pooling Area beginning Tuesday, August 18th, 2026, with an
expected completion date of Friday, September 18th, 2026, at 09:00.
A series of integrity digs will be conducted in EGT s South Pooling Area. During this time, EGT will not
allow IT and Secondary services from EGT s West 1, West 2, Flex and North Pooling Areas to EGT s South
Pooling Area.  In addition, EGT will have limited ability to schedule receipt nominations from meters that
are located on EGT s Line AC to delivery points or pools located in EGT s South Pooling Area.  Meters
include but are not limited to the following;
MP# 802267 MRT at Glendale
MP# 803500 NGPL at Hot Springs
EGT will not be capable of supporting non-ratable IT services in EGT s South Pooling area.  Shippers with
delivery points in EGT s South Pooling Area should nominate from their primary receipt point to their
primary delivery point in order to maintain the highest priority level of service.
This alert will be updated should more information become available throughout the series of digs. If
you have any questions concerning this Alert, please contact your Scheduling Representative.
For a more readable version of this document click
Here
National Fuel Gas Supply

Overbeck Plant

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Pipeline: National Fuel Gas Supply
Notice Type: Maintenance, Curtailment
Subject: Overbeck Plant
Posted Date/Time: 09/08/2026 7:39:00AM CDT
Effective Date/Time: 09/14/2026 7:00:00AM CDT
End Date/Time: 09/16/2026 3:00:00PM CDT
Notice ID: 1278992
Supersedes Notice ID: Subject: Overbeck Plant

Overbeck will be shut down for maintenance September 14th-16th.
The following facilities may experience downtime during this timeframe.



PSP1201310 Appalachian Oil & Gas Resources Inc.
PSP1235181 Appalachian Oil & Gas Resources Inc.

PSP1200035 Burnham Gas Company

PSP1228182 Dannic Energy Corporation

PSP1227241 Deitz Gas & Oil, Inc.

PSP1200751 Diversified Production LLC
PSP1201233 Diversified Production LLC
PSP1201441 Diversified Production LLC
PSP1208171 Diversified Production LLC
PSP1222971 Diversified Production LLC
PSP1224031 Diversified Production LLC
PSP1224591 Diversified Production LLC
PSP1224721 Diversified Production LLC
PSP1224951 Diversified Production LLC
PSP1225261 Diversified Production LLC
PSP1235201 Diversified Production LLC
PSP1235851 Diversified Production LLC
PSP1235861 Diversified Production LLC
PSP1236071 Diversified Production LLC
PSP1236081 Diversified Production LLC
PSP1236091 Diversified Production LLC
PSP1236431 Diversified Production LLC
PSP1238191 Diversified Production LLC
PSP1238231 Diversified Production LLC
PSP1238241 Diversified Production LLC
PSP1238261 Diversified Production LLC
PSP1238621 Diversified Production LLC
PSP1239131 Diversified Production LLC
PSP1239171 Diversified Production LLC
PSP1240981 Diversified Production LLC
PSP1242001 Diversified Production LLC
PSP1242081 Diversified Production LLC
PSP1242091 Diversified Production LLC
PSP1242111 Diversified Production LLC
PSP1242131 Diversified Production LLC
PSP1242171 Diversified Production LLC
PSP1242251 Diversified Production LLC
PSP1242281 Diversified Production LLC
PSP1242321 Diversified Production LLC
PSP1242361 Diversified Production LLC
PSP1242381 Diversified Production LLC
PSP1242401 Diversified Production LLC
PSP1242421 Diversified Production LLC
PSP1242441 Diversified Production LLC
PSP1242671 Diversified Production LLC
PSP1242801 Diversified Production LLC
PSP1243211 Diversified Production LLC
PSP1243221 Diversified Production LLC
PSP1243231 Diversified Production LLC
PSP1243241 Diversified Production LLC
PSP1243261 Diversified Production LLC
PSP1243291 Diversified Production LLC
PSP1243301 Diversified Production LLC
PSP1243321 Diversified Production LLC
PSP1243331 Diversified Production LLC
PSP1243351 Diversified Production LLC
PSP1243361 Diversified Production LLC
PSP1243371 Diversified Production LLC
PSP1243391 Diversified Production LLC
PSP1243401 Diversified Production LLC
PSP1243431 Diversified Production LLC
PSP1243461 Diversified Production LLC
PSP1243471 Diversified Production LLC
PSP1243481 Diversified Production LLC
PSP1243511 Diversified Production LLC
PSP1243521 Diversified Production LLC
PSP1243531 Diversified Production LLC
PSP1243571 Diversified Production LLC
PSP1243581 Diversified Production LLC
PSP1243591 Diversified Production LLC
PSP1243601 Diversified Production LLC
PSP1243611 Diversified Production LLC
PSP1243651 Diversified Production LLC
PSP1243671 Diversified Production LLC
PSP1243681 Diversified Production LLC
PSP1243701 Diversified Production LLC
PSP1243711 Diversified Production LLC
PSP1243721 Diversified Production LLC
PSP1243731 Diversified Production LLC
PSP1243741 Diversified Production LLC
PSP1243751 Diversified Production LLC
PSP1243811 Diversified Production LLC
PSP1243821 Diversified Production LLC
PSP1243891 Diversified Production LLC
PSP1243921 Diversified Production LLC
PSP1243931 Diversified Production LLC
PSP1243971 Diversified Production LLC
PSP1243981 Diversified Production LLC
PSP1244051 Diversified Production LLC
PSP1244071 Diversified Production LLC
PSP1244181 Diversified Production LLC
PSP1244191 Diversified Production LLC
PSP1244211 Diversified Production LLC
PSP1244231 Diversified Production LLC
PSP1244241 Diversified Production LLC
PSP1244251 Diversified Production LLC
PSP1244261 Diversified Production LLC
PSP1244271 Diversified Production LLC
PSP1244281 Diversified Production LLC
PSP1244291 Diversified Production LLC
PSP1244331 Diversified Production LLC
PSP1244351 Diversified Production LLC
PSP1244371 Diversified Production LLC
PSP1244391 Diversified Production LLC
PSP1244421 Diversified Production LLC
PSP1244531 Diversified Production LLC
PSP1244541 Diversified Production LLC
PSP1244571 Diversified Production LLC
PSP1244581 Diversified Production LLC
PSP1244591 Diversified Production LLC
PSP1245021 Diversified Production LLC
PSP1245031 Diversified Production LLC
PSP1245041 Diversified Production LLC
PSP1245051 Diversified Production LLC
PSP1245061 Diversified Production LLC
PSP1245241 Diversified Production LLC
PSP1245251 Diversified Production LLC
PSP1246151 Diversified Production LLC
PSP1250191 Diversified Production LLC
PSP1250301 Diversified Production LLC
PSP1250311 Diversified Production LLC
PSP1250421 Diversified Production LLC
PSP3100994 Diversified Production LLC

PSP1229141 Dunham,David L.

PSP1100991 Edward Oil Company
PSP1129931 Edward Oil Company
PSP1200755 Edward Oil Company
PSP1201443 Edward Oil Company
PSP1400648 Edward Oil Company

PSP1234861 Fortress Energy Corporation

PSP1201448 G & G Gas Inc.
PSP1228191 G & G Gas Inc.

PSP1201414 Glenn, W. Perry

PSP1200841 KSM Energy, Inc.
PSP1228951 KSM Energy, Inc.
PSP1228961 KSM Energy, Inc.
PSP1229111 KSM Energy, Inc.
PSP1229311 KSM Energy, Inc.
PSP1229331 KSM Energy, Inc.
PSP1230751 KSM Energy, Inc.
PSP1230761 KSM Energy, Inc.
PSP1230771 KSM Energy, Inc.
PSP1230791 KSM Energy, Inc.
PSP1230801 KSM Energy, Inc.
PSP1230811 KSM Energy, Inc.
PSP1230831 KSM Energy, Inc.
PSP1230851 KSM Energy, Inc.
PSP1230861 KSM Energy, Inc.
PSP1230891 KSM Energy, Inc.
PSP1230901 KSM Energy, Inc.
PSP1230911 KSM Energy, Inc.
PSP1231041 KSM Energy, Inc.
PSP1231131 KSM Energy, Inc.
PSP1231141 KSM Energy, Inc.
PSP1231501 KSM Energy, Inc.

PSP1222681 Natural Oil & Gas Corporation

PSP1101544 Pecora,Jay J.
PSP1200911 Pecora,Jay J.

PSP1242731 Penn View Exploration, Inc.

PSP1238071 Stonehaven Energy Management Company, LLC

PSP1134471 Wilmoth Interests, Inc.
NEXUS Gas Transmission (U.S.)

09/08/2026- Nexus Customer Specific Operational Flow Order -- LIFED -- 9/8

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name: NEXUS Gas Transmission, LLC (U.S.)
Subject: Nexus Customer Specific Operational Flow Order -- LIFED -- 9/8
Notice Type: Capacity Constraint
Critical Notice Description: Critical notice
Notice Status Description: Supersede
Notice Effective Date: 09/08/2026
Notice End Date: 12/07/2026
Posting Date: 09/08/2026
Notice Identifier: 182685
Prior Notice Identifier: 181917
Required Response Indicator Description: No response required

Operational Area
Gas Day September 7
Gas Day September 8 and until further notice
Customer Specific
OFO In Effect: No Due Pipe OFO 2% / 500
No OFO*
Columbia Gas Transmission (TCO)

LIFTED: OFO - Receipt Points in Market Areas 26, 30, 35, 41, 42, Eff. ID1 Tuesday, September 8, 2026

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name Columbia Gas Transmission, LLC
TSP 054748041
Notice Type Description: Operational Flow Order

Notice Stat Desc: Supersede

Prior Notice: 26239008

Critical: Y

Reqrd Rsp Desc: No Response Required
Post

Notice Effective

Notice End



Response
Post Date: 09/08/26

09/08/26

10/08/26
Subject: Subject: LIFTED: OFO - Receipt Points in Market Areas 26, 30, 35, 41, 42, Eff. ID1 Tuesday, September 8, 2026
Author: Author: Dillon Schoolcraft
Notice Text
Columbia Gas Transmission, LLC (TCO) notifies shippers the Operational Flow Order (OFO) impacting receipt points in Market Areas 26, 30, 35, 41 and 42 is lifted effective Intraday Gas Day Tuesday, September 8, 2026. 

TCO reserves the right to reinstate the OFO as operationally necessary. As a reminder, the Pre-OFO (Notice ID 26203010) remains in effect. 

Please contact your Customer Services Representative with any questions.

***Previous Posting***

Pursuant to the provisions of Section 17 of the General Terms and Conditions of its FERC Gas Tariff, Columbia Gas Transmission, LLC (TCO) is issuing an Operational Flow Order ("OFO") to Shippers under all transportation rate schedules with receipts in Market Areas 26, 30, 35, 41, and 42 to protect the operational integrity of TCO’s system and its ability to meet its firm service obligations.  

 

As explained in Pre OFO (Notice ID 26205016), due to mild weather forecasts, anticipated lower market demand, higher storage and line pack levels, and the level of production received in Market Areas 26, 30, 35, 41, and 42, physical receipts must be equal to or less than scheduled receipts in order to maintain system integrity and provide reliable firm service. Consequently, TCO cannot allow excess receipts at any receipt point in these Market Areas.

 

Therefore, TCO is issuing the following Operational Flow Order (OFO): 

  

1. The Time and Date of Issuance of this OFO is Friday, September 4, 2026, at 8:05 AM ET. 

 

2. The OFO will become effective for Gas Day Saturday, September 5, 2026. 

 

3. This OFO will continue in duration until TCO issues further notice of termination of this OFO. 

 

4. The Shippers impacted by this OFO are those scheduling receipts of gas in Market Areas 26, 30, 35, 41, and 42 whose physical receipts are not less than or equal to their scheduled receipts during a Gas Day.  

 

5. Pursuant to the OFO, the following actions must be taken:  

During the period this OFO is in effect, impacted shippers must align scheduled quantities with physical quantities in Market Areas 26, 30, 35, 41, and 42, which may require communication with upstream operators. Shippers must remain in balance at the start of, and throughout, each Gas Day, beginning Saturday, September 5, 2026, and continuing until further notice. Receipt points must be balanced such that actual receipts into Market Areas 26, 30, 35, 41, and 42 must be less than or equal to the scheduled receipt quantities into these areas unless otherwise mutually agreed on a nondiscriminatory basis.  

 

6. The justification for issuing the OFO is as set forth above. 

 

7. Additional information: Shippers who do not comply will be subject to penalties in accordance with Section 19.3 of TCO’s FERC Gas Tariff. Shippers are encouraged to stay coordinated with upstream suppliers regarding changes in physical flow for the duration of the OFO. 

 

If a penalty is assessed, the penalty will be based on all quantities in aggregate in violation of the OFO in excess of a tolerance of 5% of scheduled receipt quantities or 5,000 Dth whichever is higher. This tolerance will be in effect during the OFO unless revised through an update to this notice.   Penalties will be based on the shipper’s prorated share of the total excess quantities above the tolerance at the receipt point for that day at the higher of: (i) a price per Dth equal to three times the midpoint of the range of prices reported for "Columbia Gas, Appalachia" as published in Platts Gas Daily price survey for the days on which the OFO is issued, or (ii) a price per Dth equal to 150 percent of the highest midpoint posting for either: Mich Con City-gate, Transco, Zone 6 Non-N.Y., or Texas Eastern, M-2 Receipts as published in Platts Gas Daily price survey for the days on which the OFO is issued. Penalties under Section 19.3 (ii) will only be assessed on days in which the daily spot price of gas exceeds three times the midpoint of the range of prices reported for "Columbia Gas, Appalachia."  

 

Please contact your Customer Services Representative with any questions.
Columbia Gas Transmission (TCO)

CAPACITY POSTING - TIM for September 9, 2026

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name Columbia Gas Transmission, LLC
TSP 054748041
Notice Type Description: Capacity Constraint

Notice Stat Desc: Initiate

Prior Notice: 

Critical: Y

Reqrd Rsp Desc: No Response Required
Post

Notice Effective

Notice End



Response
Post Date: 09/08/26

09/08/26

10/08/26
Subject: Subject: CAPACITY POSTING - TIM for September 9, 2026
Author: Author: Dillon Schoolcraft
Notice Text
COLUMBIA GAS TRANSMISSION, LLC DAILY CAPACITY POSTING

Columbia Gas Transmission LLC (TCO) posts projections of anticipated market area restrictions at least 24 hours prior to the time when nominations are due. These advance forecasts are subject to change based on actual operating conditions. Customers desiring non-firm services should submit timely nominations to determine whether the service is available under current conditions.

============================================================================

============================================================================

FORCE MAJEURE / STORAGE CRITICAL / TRANSPORT CRITICAL / OFO / RATABLE TAKES

No Force Majeure is necessary.

* The Critical Day for Storage Injections is LIFTED in all Op Areas effected Intraday 1, Gas Day Tuesday, September 8, 2026. Please see Critical Notice ID # 26239021 for details.

No Critical Day for Transport is necessary.

* The Operational Flow Order (OFO) for Receipt Points in Market Areas 26, 30, 35, 41 & 42 is LIFTED effective Intraday Gas Day Tuesday, September 8, 2026. Please see Critical Notice ID # 26239022 for details.

Ratable Takes are not required in any Market Areas; however, power customers should request non-ratable takes by submitting a burn profile through TCeConnects.

============================================================================

============================================================================

PIPELINE RECEIPTS, DELIVERIES, INTERNAL CONSTRAINTS, AND DISPLACEMENT AVAILABILITY

For receipts, deliveries, and internal constraints not specifically listed below, please refer to ebb.tceconnects.com/Info Post/Capacity/Operationally Available for information on available capacity at each receipt and delivery point and ebb.tceconnects.com/Info Post/Capacity/Est Op Avail Cap - Internal Constraint for available non-firm capacity at each internal constraint.

Columbia may, from time to time, have displacement capacity available at various receipt/delivery points. Displacement nominations are scheduled based on operational availability up to an approved amount not to exceed the scheduled volumes in the physical direction of flow of the meter. Please contact your Customer Services, Marketing, or O&L Representative for availability at points not listed on this notice.

============================================================================

============================================================================

----------------------------------------------------------------------------

POINT CONSTRAINTS-- Non-Firm Available Capacity:

---------------------------------------------------------------------------- 

633863 - NFG Hartzfelt Mountain - 11,000

* 636978 - Pine Glen - * 0

* 637095 - MTN GATHERING-HOMER CITY - * 0 Total Capacity

* 637887 - Exotic – Oblinski - * 0

640203 - Wagoner Line K - 25,000

640296 - CLINGERMAN - 0

640297 - Range - Sharp - 0

640496 - Range - Day - 0 

640564 - Amwell – 0

* 640616 - Anadarko Midstream Beech Creek - * 0 

642452 - CMG Majorsville - 0

642569 - Mojo - 0

642831 - Range Mills - 0

642838 - Strabane - 0

642854 - Kryptonite - 0

740178 - Fairfield - REX - 75,000

743064 - NEXUS MR06 - 75,000

743365 - Quarry Road - 25,000

736626 - DPL CENTERVILLE - 10,000

737067 - Darby Plant - 75,000

821590 - THOMAS COFFMAN INC YOUNG - 0 

821917 - A&W-Gandee - 0 

823621 - MOUNTAIN STATE-GRANT - 0

824017- STERLING DRG FETTTY - 0 

824766 - TECHNOLOGY DEVELOPMENT - FIELDS - 0 

825005 - CENTRAL PACIFIC GROUP SNYDER - 0 

826130 - STERLING DRG HARPER - 0 

828516 - DORAN-RAINES #1 - 0

833097 - BOSWELLS TAVERN (75-007219) - 0 (Receipts)

833097 - BOSWELLS TAVERN (75-007219) - 100,000

834263 - MCKOWN-JB YOAK LEASE - 0 

835078 - RYAN #702 - 0 

839166 - Patton - 0 

840226 - BenGay MM - 0 

840254 - Vandalia - 0 Total Capacity

842446 - Spencer H Line Sales - 0 

842866 - Green Energy Stonewall - 0

843105 - Transco Chantilly - 50,000

B10 - CAMBRIDGE-9 - 20,000

B15 - UNIONVILLE-35 - 10,000

B17 - HIGHLAND-36 - 20,000

B18 - MILFORD-21 - 0

B9 - BROAD RUN-19 - 0 (Receipts)

B9 - BROAD RUN-19 - 0 (Deliveries)

BYBEE - BYBEE - 0 (Deliveries)

C10 - PLEASANT - 0

C14 - WAYNESBURG - 20,000 

C15 - UNIONTOWN-35 - 0

C16 - DELMONT-36 - 0 (Receipts)

C16 - DELMONT-36 - 0 (Deliveries)

C22 - EAGLE-25 - 0

C23 - PENNSBURG-23 - 0

C41 - TEXAS EASTERN TETCON - 100,000

C45 - Marietta - 0

C9 - HOOKER-5 - 50,000

CNR06 - CHK Hubball/Horse Ck/NYE - 0

E13 - EMPORIA, VA-34 - 0

E17 - MARTINS CREEK - 21 - 0 (Receipts)

E17 - MARTINS CREEK - 21 - 15,000 (Deliveries)

E2 - ROCKVILLE-30 - 0

E3 - DOWNINGTOWN-29 - 0

E9 - YNG WOMANS CK-RENOVO - 0

MVPWB - MVP Columbia WB - 0 (Receipts)

MVPWB - MVP Columbia WB - 0 (Deliveries)

----------------------------------------------------------------------------

DELIVERY INTERNAL CONSTRAINTS-- Non-Firm Available Capacity:

----------------------------------------------------------------------------

ARTEMAS - Artemas MA25 - 0

BICKBOSW - Bickers MA33 - No Restriction 

CERELANH - Lanham East MA19 - 0 

CERELANW - Lanham West MA19 - 0

CORNHART - Corning East MA20 - 0

CRAWNORT - Crawford North MA8 - 0

CSLOSTRI - Lost River CS MA30 - No Restriction

DELMONSO - Delmont South MA36 - 10,000

DOWNEAST - Downingtown East MA24 - 25,000

GRENCSTL - Greencastle MA25 - No Restriction

HELLHANO - Hellertown MA22 - 0

HIGHLAND - Highland MA38 - 10,000

HOPEWELL - Hopewell MA33 - No Restriction

INDEGLAS - Corning West MA20 - 5,548

KAEAST - KA East MA17 - 0

LANPKA - Lanham PKA MA19 - 0

LEACHSEG - Leach MA19 - No Restriction

LOUDOUN - Loudoun MA28 - No Restriction

LOUISA - Louisa MA33 - No Restriction 

MA1SEG - Pavonia to Toledo - 10,000 

MA3SEG - Lima MA3 - 10,000 

MA6SEG - Dayton MA6 – 20,000

MA7SEG - Sandusky MA7 - 60,000 

NORTKENT - Northern Kentucky OA6 - No Restriction

PTJRWARW - Wagoner East MA21 - No Restriction

RUTLEDGE - Rutledge North MA28 - 50,000

SENECA - Seneca MA30 - No Restriction

----------------------------------------------------------------------------

RECEIPT INTERNAL CONSTRAINTS-- Non-Firm Available Capacity:

----------------------------------------------------------------------------

A03LINEH - Cobb Line H MA18 - No Restriction

A03LOW - Cobb Northwest MA18 - No Restriction

A03NORTH - Cobb Northeast MA40 - No Restriction

A03SOUTH - Cobb South MA18 - No Restriction

ADALSMIF - Smithfield to Adaline MA35 - 0

ALLIAREC - Alliance Receipts MA4 - 20,000

BOLDMAN - Boldman MA16 - 0

CHSTKENO - Line P North MA16 - 0

CLENWAYN - Clendenin to Waynesburg MA35 - 0

COBBA03 - Cobb CS MA18 - No Restriction

CRAWSOUT - Crawford South MA8 - No Restriction

DELMRENO - Delmont MA36 - No Restriction

DOWNWEST - Downingtown West MA24 - 0

EASTON - Easton MA21 - 0

GRANHAML - KA High MA19 - 25,000

HANCOCK - Hancock MA20 - 0

KA1SCBYB - KA1 Station Camp MA13 - 5,500

KAWEST - KA West MA17 - 0

LEBANON - Lebanon MA6 - 50,000 

LONEOAKA - Lone Oak A MA41 - 0

LONEOAKB - Lone Oak B MA41 - 0 

LXPSEG - LXPSEG MA41 - 0

MAYTHUFF - KA Low MA16 - 0 

MXPSEG - MXPSEG MA42 - 0

RUTSOUTH - Rutledge South MA28 - 0 

SHERWODA - Sherwood A MA42 - 0

SHERWODB - Sherwood B MA42 - 100,000 

SMITHFLD - Smithfield MA35 - 0

TANNDELM - Line 1711 MA35 - 0

WALGROVE - Walgrove MA18 - No Restriction

WAYNESNO - Waynesburg North MA35 - 0

 

----------------------------------------------------------------------------

DISPLACEMENT AVAILABILITY-- Non-Firm Available Capacity:

----------------------------------------------------------------------------

843067 - Cornwell - 100,000 

C14 - WAYNESBURG - 30,000

C22 - EAGLE-25 - 25,000

C23 - PENNSBURG-23 - 0

C4 - TETCO LEBANON-6 - 0

E2 - ROCKVILLE-30 - 0

LOUDOUN - LOUDOUN LNG - 0

----------------------------------------------------------------------------

TRANSFER METERS-- Non-Firm Available Capacity:

----------------------------------------------------------------------------

TMBOSWLL - TM Boswells Tavern MA33 - 500,000

TMBRDRUN - TM Broad Run MA19 - 500,000

TMCEREDO - TM Ceredo MA19 - 500,000

TMCHANTY - TM Chantilly MA30 - 500,000

TMEAGLE - TM Eagle MA25 - 500,000

TMLEACH - TM Leach MA19 - 500,000

TMLOSTRI - TM Lost River MA30 - 500,000

TMLOUDN - TM Loudoun MA30 - 500,000

TMLXP - TM LXP MA41 - 500,000

TMMXP - TM MXP MA42 - 500,000

----------------------------------------------------------------------------

LOGICAL METERS-- Non-Firm Available Capacity:

----------------------------------------------------------------------------

MLAPLGRV – Mainline Apple Grove - 500,000

MLCRWFRD - Mainline Crawford - 500,000

MLDRYCRE - Mainline Dry Creek - 500,000

MLEAGLE - Mainline Eagle - 500,000

MLLEACH - Mainline Leach - 500,000

MLLOUDOU - Mainline Loudoun - 500,000

MLLXPMAJ - Mainline LXP Majorsville - 500,000

MLNEWALB - Mainline New Albany - 500,000 

MLPETERS - Mainline Petersburg - 500,000

MLSDRCRK - Mainline Saunders Creek - 500,000

----------------------------------------------------------------------------

DUE PIPE AND DUE SHIPPER AVAILABILITY:

----------------------------------------------------------------------------

OP AREA 01 - Due Pipe - 0, Due Shipper - No Restriction

OP AREA 02 - Due Pipe - 0, Due Shipper - No Restriction

OP AREA 03 - Due Pipe - 0, Due Shipper - No Restriction

OP AREA 04 - Due Pipe - 0, Due Shipper - No Restriction 

OP AREA 05 - Due Pipe - 0, Due Shipper - No Restriction

OP AREA 06 - Due Pipe - 0, Due Shipper - No Restriction

OP AREA 07 - Due Pipe - 0, Due Shipper - No Restriction

OP AREA 08 - Due Pipe - 0, Due Shipper - No Restriction 

OP AREA 10 - Due Pipe - 0, Due Shipper - No Restriction

============================================================================

============================================================================

PAL & IT BUSINESS

Representatives are available daily to discuss PAL transactions with customers who have executed Master PAL Agreements. (Reminder: Each PAL transaction including rate, term, quantity and point(s) must be provided for and approved on the Appendix A under the Master PAL Agreement).Customers who are interested in discounted PAL transactions for next-day or long-term park and/or lend transactions or daily discounted IT paths should contact Diana Roberts at 832-320-5454 (ICE droberts6) or Adam Herndon at 832-689-4510 (ICE adherndon) for more information.

AUTO PAL AVAILABILITY

Effective with EVENING Cycle for each Gas Day, Auto Parks/Loans will be limited to +/-5,000 Dth.Customers are reminded the intent of AutoPAL service is to utilize nominal quantities to resolve pool imbalances that result from upstream or downstream reductions during the cycle.This service should not be used for parking or loaning large quantities.

The following services are eligible for Auto Park/Loan Paybacks and Auto Loan/Park Withdrawals:

IPP

SPP

A01 - Kenova

A02 - Flat Top

A03 - Cobb

A04 - Alexander 

A05 - Delmont 

A06 - McClellandtown

A08 - Crawford

A09 - York 

A10 - Dungannon 

A11 - Binghamton

A12 - Mountaineer Xpress

* Denotes a change from previous posting
Texas Eastern Transmission (TETCO)

09/07/2026- TE Pipeline Conditions for 09/08/2026

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name: Texas Eastern Transmission, LP
Subject: TE Pipeline Conditions for 09/08/2026
Notice Type: Capacity Constraint
Critical Notice Description: Critical notice
Notice Status Description: Initiate
Notice Effective Date: 09/08/2026
Notice End Date: 09/09/2026
Posting Date: 09/07/2026
Notice Identifier: 182682
Required Response Indicator Description: No response required

For Gas Day September 8, 2026, Texas Eastern (TE) has approved and scheduled nominations at each pipeline segment and meter station up to TE's operational capacity. The following locations have been restricted due to requested nominations exceeding TE's operational capacity:
Restricted Locations
Scheduled and Sealed
Priority % Restricted
Notes
TABS
North of Berne
Meter 75919 Deliveries
N/A
100%
100%
87%
Rec from AGT & Del West of Lambertville
100%
100%
100%
TE/AGT Lease
Yes
To Lease Capacity
Nexus/TE Leased Meters
Yes
To Lease Capacity
30" South of Berne
Berne - Southbound
N/A
100%
100%
Danville - Southbound
N/A
100%
100%
Tompkinsville - Southbound
N/A
100%
100%
Barton - Southbound
N/A
100%
100%
24"
Sarahsville - Southbound
N/A
100%
100%
100%
100%
50%
Unplanned Outage
Five Points - Southbound
N/A
100%
61%
Unplanned Outage
Lebanon
N/A
100%
53%
Unplanned Outage
Lebanon Lateral
N/A
100%
87%
Batesville - Southbound
N/A
100%
77%
Meter 74215 Deliveries
Yes
Access Area
Union Church - Southbound
N/A
100%
47%
New Roads South - Southbound
N/A
100%
94%
White Castle - Southbound
N/A
100%
95%
Longview - Northbound
Yes
Huntsville - Northbound
Yes
Speaks - Southbound
N/A
100%
81%
Angleton West - Northbound
N/A
100%
95%
Vidor East - Northbound
N/A
100%
44%
Deliveries to BIG
N/A
100%
100%
100%
100%
100%
Planned Outage
Gillis - Northbound
N/A
100%
52%
TABS Pool Restrictions - Tolerances
ETX
STX
WLA
ELA
M1-24"
M1-30"
M2-24"
M2-30"
TABS Pool - Length
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
TABS Pool - Short
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
No-Notice Restrictions
OFO / Imbalance Notice
OFO
---
Action Alert
---
Customer Specific OFO
---
Imbalance Warnings
Stay Balanced - Access Area, M1-24, M1-30,M2-24, M2-30, and M3
FERC Order 698
M2-24, M2-30 and M3
Gas Quality:
Due to gas quality issues, meter 76609 has been shut in and physical receipts at the meter will be unavailable until further notice.  Beginning during the Timely cycle for Gas Day December 6, 2025, and until further notice, TE will restrict receipt nominations at Meter 76609 to -0- Dth/d.
Systemwide Notes:
Shippers in all Texas Eastern's Access Area Zones and Market Area Zones M1-30, M2-30 and M3 are required to coordinate any imbalance payback through TE's account representative and actual payback quantities may be limited depending on system operations and conditions. If customers do not adhere to imbalance requirements stated above, TE will utilize any provision of its tariff to ensure system integrity including the issuance of customer specific or system wide OFOs.
Please contact your Operations Account Representative should you have any questions.
Steckman Ridge

09/07/2026- SR Storage Conditions for 09/08/2026

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name: Steckman Ridge, LP
Subject: SR Storage Conditions for 09/08/2026
Notice Type: Capacity Constraint
Critical Notice Description: Critical notice
Notice Status Description: Initiate
Notice Effective Date: 09/08/2026
Notice End Date: 09/09/2026
Posting Date: 09/07/2026
Notice Identifier: 182664
Required Response Indicator Description: No response required

Notice Text:
The following restriction will be in place on the Steckman Ridge system for Gas Day September 8, 2026:
Steckman Ridge has restricted a portion of excess injections. No increases in injections will be accepted except to comply with NAESB bump guidelines.
Customers are advised that capacity may become available as the nomination and confirmation process continues throughout the day.
Please contact your Operations Account Representative if you have any questions.
Southeast Supply Header

09/07/2026- SESH Pipeline Conditions for 09/08/2026

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name: Southeast Supply Header, LLC
Subject: SESH Pipeline Conditions for 09/08/2026
Notice Type: Capacity Constraint
Critical Notice Description: Critical notice
Notice Status Description: Initiate
Notice Effective Date: 09/08/2026
Notice End Date: 09/09/2026
Posting Date: 09/07/2026
Notice Identifier: 182658
Required Response Indicator Description: No response required

For Gas Day September 8, 2026, Southeast Supply Header (SESH) has approved and scheduled nominations at each pipeline segment and meter station up to SESH's operational capacity. The following locations have been restricted due to requested nominations exceeding SESH's operational capacity:
Restricted Locations
Scheduled and Sealed
Priority % Restricted
Notes
Gwinville
100%
Gwinville East
100%
OFO / Imbalance Notice
OFO
---
Customer Specific OFO
---
Imbalances Warnings
No DP - System Wide
Systemwide Notes:
SESH has limited operational flexibility to manage imbalances. As a result, SESH requires all delivery point operators to keep actual daily takes out of the system equal to or less than scheduled quantities regardless of their cumulative imbalance position unless otherwise coordinated with your operations account representative.
Customers are advised that capacity may become available as the nomination and confirmation process continues throughout the day.
Please contact your Operations Account Representative should you have any questions.
East Tennessee Natural Gas

09/07/2026- ETNG Pipeline Conditions for 09/08/2026

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name: East Tennessee Natural Gas, LLC
Subject: ETNG Pipeline Conditions for 09/08/2026
Notice Type: Capacity Constraint
Critical Notice Description: Critical notice
Notice Status Description: Initiate
Notice Effective Date: 09/08/2026
Notice End Date: 09/09/2026
Posting Date: 09/07/2026
Notice Identifier: 182659
Required Response Indicator Description: No response required

For Gas Day September 8, 2026, East Tennessee Natural Gas (ETNG) has approved and scheduled nominations at each pipeline segment and meter station up to ETNG's operational capacity. The following locations have been restricted due to requested nominations exceeding ETNG's operational capacity:
Restricted Locations
Scheduled and Sealed
Priority % Restricted
Notes
Deliveries To Texas Eastern
100%
100%
100%
100%
Topside South
100%
100%
81%
Fordtown West - Westbound
Yes
Flatwoods East - Westbound
Yes
OFO / Imbalance Notice
OFO
---
Customer Specific OFO
---
Hourly Customer Specific OFO
---
Action Alert
---
Imbalances Warnings
Stay Balanced
Systemwide Notes:
ETNG requires any imbalance payback be coordinated through your Operations Account Representative.
If necessary, ETNG will utilize any provision of its tariff to ensure system integrity including the issuance of customer specific or system wide OFOs.
Effective October 1, 2025, MR 59200 - SNG Whitfield will be restricted to 0 Dth / d until further notice due to SNG pressures being lower than ETNG's typical operating pressure. Also, effective October 1, 2025, MR 59311 - SNG Bradley will be limited to its meter capacity of 31,000 Dth/d.
Customers are advised that capacity may become available as the nomination and confirmation process continues throughout the day.
Please contact your Operations Account Representative should you have any questions.
East Tennessee Natural Gas

09/06/2026- ETNG Pipeline Conditions for 09/07/2026

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name: East Tennessee Natural Gas, LLC
Subject: ETNG Pipeline Conditions for 09/07/2026
Notice Type: Capacity Constraint
Critical Notice Description: Critical notice
Notice Status Description: Initiate
Notice Effective Date: 09/07/2026
Notice End Date: 09/08/2026
Posting Date: 09/06/2026
Notice Identifier: 182628
Required Response Indicator Description: No response required

For Gas Day September 7, 2026, East Tennessee Natural Gas (ETNG) has approved and scheduled nominations at each pipeline segment and meter station up to ETNG's operational capacity. The following locations have been restricted due to requested nominations exceeding ETNG's operational capacity:
Restricted Locations
Scheduled and Sealed
Priority % Restricted
Notes
Deliveries To Texas Eastern
100%
100%
100%
100%
Topside South
100%
100%
81%
Fordtown West - Westbound
Yes
Flatwoods East - Westbound
Yes
OFO / Imbalance Notice
OFO
---
Customer Specific OFO
---
Hourly Customer Specific OFO
---
Action Alert
---
Imbalances Warnings
Stay Balanced
Systemwide Notes:
ETNG requires any imbalance payback be coordinated through your Operations Account Representative.
If necessary, ETNG will utilize any provision of its tariff to ensure system integrity including the issuance of customer specific or system wide OFOs.
Effective October 1, 2025, MR 59200 - SNG Whitfield will be restricted to 0 Dth / d until further notice due to SNG pressures being lower than ETNG's typical operating pressure. Also, effective October 1, 2025, MR 59311 - SNG Bradley will be limited to its meter capacity of 31,000 Dth/d.
Customers are advised that capacity may become available as the nomination and confirmation process continues throughout the day.
Please contact your Operations Account Representative should you have any questions.
Tennessee Gas Pipeline (TGP)

GAS QUALITY ISSUE AT CALEDONIA 9-7-26

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Interstate
Other
Midstream
Informational Postings
Capacity
Gas Electric Coordination
Gas Quality
Index of Customers
Locations
Notices
Posted Imbalances
Regulatory
Standards of Conduct
Tariff
Transactional Reporting
Info Lookup
Other
Downloads
Search
Customer Activities
Site Map
	
	
NOTICE DETAIL
	
PDF
TEXT
Return To Results
TSP/TSP Name:  1939164-TENNESSEE GAS PIPELINE	Critical: Y
Notice Type Desc (1):  GAS QUALITY	Notice Type Desc (2):  ISSUES
Notice Eff Date/Time:  09/07/2026 11:41:17AM	Notice End Date/Time:  09/08/2026 9:00:00am
Post Date/Time:  9/7/2026 11:41:17 AM	Notice ID: 404036
Reqrd Rsp:  1	Rsp Date/Time:  9/7/2026 12:00:00 AM
Notice Stat Desc:  INITIATE	Prior Notice: 
Subject:  GAS QUALITY ISSUE AT CALEDONIA 9-7-26
Notice Text:

GAS QUALITY ISSUE AT CALEDONIA STORAGE METER (412734) EFFECTIVE 9-7-2026

A gas quality issue has been reported at the receipt from the TGP/Caledonia Storage Meter (Pin #412734) in Lowndes County, Mississippi.  Tennessee is in the process of investigating and monitoring the issue.  Therefore, in accordance with Article II, Section 9 of the General Terms & Conditions of Transporter's Tariff, effective for the gas day Tuesday, September 8, 2026 for Timely Cycle, and until further notice, this point may need to be at reduced flow or shut-in.  Nominations will be scheduled accordingly until the gas quality issue has been resolved.  All transportation services are at risk of not getting scheduled. 

Tennessee Gas Pipeline will continue to work with the point operator and will update via the EBB when more information is obtained.

Please contact your Scheduling Representative if you have any questions.

..
Texas Eastern Transmission (TETCO)

09/06/2026- TE Pipeline Conditions for 09/07/2026

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name: Texas Eastern Transmission, LP
Subject: TE Pipeline Conditions for 09/07/2026
Notice Type: Capacity Constraint
Critical Notice Description: Critical notice
Notice Status Description: Initiate
Notice Effective Date: 09/07/2026
Notice End Date: 09/08/2026
Posting Date: 09/06/2026
Notice Identifier: 182637
Required Response Indicator Description: No response required

For Gas Day September 7, 2026, Texas Eastern (TE) has approved and scheduled nominations at each pipeline segment and meter station up to TE's operational capacity. The following locations have been restricted due to requested nominations exceeding TE's operational capacity:
Restricted Locations
Scheduled and Sealed
Priority % Restricted
Notes
TABS
North of Berne
Meter 75919 Deliveries
N/A
100%
100%
87%
Rec from AGT & Del West of Lambertville
100%
100%
100%
ISS-1 Injections (1)
N/A
100%
FSS, SS-1 and SS Injections (1)
N/A
100%
30" South of Berne
Berne - Southbound
N/A
100%
100%
Danville - Southbound
N/A
100%
100%
Tompkinsville - Southbound
N/A
100%
100%
Barton - Southbound
N/A
100%
100%
24"
Sarahsville - Southbound
N/A
100%
100%
100%
100%
Unplanned Outage
Five Points - Southbound
N/A
100%
61%
Unplanned Outage
Lebanon
N/A
100%
53%
Unplanned Outage
Lebanon Lateral
N/A
100%
94%
Batesville - Southbound
N/A
100%
77%
Meter 74215 Deliveries
Yes
Access Area
Union Church - Southbound
N/A
100%
54%
New Roads South - Southbound
N/A
100%
94%
White Castle - Southbound
N/A
100%
95%
Longview - Northbound
N/A
100%
30%
Huntsville - Northbound
Yes
Speaks - Southbound
N/A
100%
81%
Angleton West - Northbound
N/A
100%
34%
Vidor East - Northbound
Yes
Gillis - Northbound
N/A
100%
53%
TABS Pool Restrictions - Tolerances
ETX
STX
WLA
ELA
M1-24"
M1-30"
M2-24"
M2-30"
TABS Pool - Length
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
TABS Pool - Short
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
No-Notice Restrictions
OFO / Imbalance Notice
OFO
No DS - M1-24, M1-30, M2-24, M2-30 and M3, issued 9/5/2026. 5% / 500 Dth Tolerance
Action Alert
---
Customer Specific OFO
---
Imbalance Warnings
Stay Balanced - Access Area
FERC Order 698
M2-24, M2-30 and M3
Gas Quality:
Due to gas quality issues, meter 76609 has been shut in and physical receipts at the meter will be unavailable until further notice.  Beginning during the Timely cycle for Gas Day December 6, 2025, and until further notice, TE will restrict receipt nominations at Meter 76609 to -0- Dth/d.
Systemwide Notes:
(1) Beginning 9:00 AM CCT September 5, 2026, through 9:00 AM CCT September 8, 2026, excess injections on all ISS-1, FSS-1, SS-1 and SS contracts will be restricted as well as TT16, TT17, TT24 no-notice balancing, no-notice pre-injection and no-notice payback for prior month.
Shippers in all Texas Eastern's Access Area Zones and Market Area Zones M1-30, M2-30 and M3 are required to coordinate any imbalance payback through TE's account representative and actual payback quantities may be limited depending on system operations and conditions. If customers do not adhere to imbalance requirements stated above, TE will utilize any provision of its tariff to ensure system integrity including the issuance of customer specific or system wide OFOs.
Please contact your Operations Account Representative should you have any questions.
Steckman Ridge

09/06/2026- SR Storage Conditions for 09/07/2026

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name: Steckman Ridge, LP
Subject: SR Storage Conditions for 09/07/2026
Notice Type: Capacity Constraint
Critical Notice Description: Critical notice
Notice Status Description: Initiate
Notice Effective Date: 09/07/2026
Notice End Date: 09/08/2026
Posting Date: 09/06/2026
Notice Identifier: 182629
Required Response Indicator Description: No response required

Notice Text:
The following restriction will be in place on the Steckman Ridge system for Gas Day September 6, 2026:
Steckman Ridge has restricted a portion of excess injections. No increases in injections will be accepted except to comply with NAESB bump guidelines.
Customers are advised that capacity may become available as the nomination and confirmation process continues throughout the day.
Please contact your Operations Account Representative if you have any questions.
Steckman Ridge

09/06/2026- SR Storage Conditions for 09/07/2026

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name: Steckman Ridge, LP
Subject: SR Storage Conditions for 09/07/2026
Notice Type: Capacity Constraint
Critical Notice Description: Critical notice
Notice Status Description: Supersede
Notice Effective Date: 09/07/2026
Notice End Date: 09/08/2026
Posting Date: 09/06/2026
Notice Identifier: 182638
Prior Notice Identifier: 182629
Required Response Indicator Description: No response required

Notice Text:
The following restriction will be in place on the Steckman Ridge system for Gas Day September 7, 2026:
Steckman Ridge has restricted a portion of excess injections. No increases in injections will be accepted except to comply with NAESB bump guidelines.
Customers are advised that capacity may become available as the nomination and confirmation process continues throughout the day.
Please contact your Operations Account Representative if you have any questions.
Southeast Supply Header

09/06/2026- SESH Pipeline Conditions for 09/07/2026

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name: Southeast Supply Header, LLC
Subject: SESH Pipeline Conditions for 09/07/2026
Notice Type: Capacity Constraint
Critical Notice Description: Critical notice
Notice Status Description: Initiate
Notice Effective Date: 09/07/2026
Notice End Date: 09/08/2026
Posting Date: 09/06/2026
Notice Identifier: 182627
Required Response Indicator Description: No response required

For Gas Day September 7, 2026, Southeast Supply Header (SESH) has approved and scheduled nominations at each pipeline segment and meter station up to SESH's operational capacity. The following locations have been restricted due to requested nominations exceeding SESH's operational capacity:
Restricted Locations
Scheduled and Sealed
Priority % Restricted
Notes
Gwinville
100%
Gwinville East
100%
OFO / Imbalance Notice
OFO
---
Customer Specific OFO
---
Imbalances Warnings
No DP - System Wide
Systemwide Notes:
SESH has limited operational flexibility to manage imbalances. As a result, SESH requires all delivery point operators to keep actual daily takes out of the system equal to or less than scheduled quantities regardless of their cumulative imbalance position unless otherwise coordinated with your operations account representative.
Customers are advised that capacity may become available as the nomination and confirmation process continues throughout the day.
Please contact your Operations Account Representative should you have any questions.
Iroquois Gas Transmission

Capacity Constraint

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Critical Notice Effective Timely Cycle, Gas Day September 7, 2026, Iroquois nominations are at capacity and sealed from all increases for the following location(s): -       Brookfield Interconnect with Algonquin Gas Transmission. In addition, the following capacity has been reduced: -       Park, Interruptible and Secondary receipt nominations at the Brookfield Interconnect are reduced by 100%. Customers will be advised if further capacity becomes available during the day as volumes are nominated and confirmed. Please contact your account representative or Gas Control for further information. End date 09/08/2026 09:00 CCT
Transco

UPDATE - Non-Tariff Quality Gas at PETTUS OUTLET M3649

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Pipeline: Transco
Notice: UPDATE - Non-Tariff Quality Gas at PETTUS OUTLET M3649
Posted: 09/06/2026 12:57:56 CDT
Notice ID: 17246654

TRANSCONTINENTAL GAS PIPE LINE COMPANY, LLC

Critical:
 Y

Notice Eff Date:
 09/06/2026

Notice Eff Time:
 12:57:56 CDT

Notice End Date:
 

Notice End Time:
 

Notice ID:
 17246654

Notice Stat Desc:
 Supersede

Notice Type Desc:
 Gas Qual

Post Date:
 09/06/2026

Post Time:
 12:57:56 CDT

Prior Notice:
 17246114

Reqrd Rsp Desc:
 Immediate response required of an operational nature may be required of impacted shippers

Rsp Date:
 

Rsp Time:
 

TSP:
 007933021

TSP Name:
 TRANSCONTINENTAL GAS PIPE LINE COMPANY, LLC

Notice Text: 
Subject: 
UPDATE - Non-Tariff Quality Gas at PETTUS OUTLET M3649
Effective 
ID2
 for 
GD 9/6/2026
 Transco will allow scheduling and begin receiving gas at PETTUS OUTLET M3649 (Location ID 9007543).
 
Location ID 
 
Location Name
 
Flow Direction
 
9007543
 
PETTUS OUTLET M3649
Receipt
 
If you have any questions, please contact your Transportation Services Representative.
Transco

Non-Tariff Quality Gas at PETTUS OUTLET M3649

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Pipeline: Transco
Notice: Non-Tariff Quality Gas at PETTUS OUTLET M3649
Posted: 09/06/2026 09:28:52 CDT
Notice ID: 17246110

TRANSCONTINENTAL GAS PIPE LINE COMPANY, LLC

Critical:
 Y

Notice Eff Date:
 09/06/2026

Notice Eff Time:
 09:28:52 CDT

Notice End Date:
 

Notice End Time:
 

Notice ID:
 17246110

Notice Stat Desc:
 Initiate

Notice Type Desc:
 Gas Qual

Post Date:
 09/06/2026

Post Time:
 09:28:52 CDT

Prior Notice:
 

Reqrd Rsp Desc:
 Immediate response required of an operational nature may be required of impacted shippers

Rsp Date:
 

Rsp Time:
 

TSP:
 007933021

TSP Name:
 TRANSCONTINENTAL GAS PIPE LINE COMPANY, LLC

Notice Text: 
Subject: 
Non-Tariff Quality Gas at PETTUS OUTLET M3649
Transco is receiving gas at the PETTUS OUTLET M3649 (Location ID 9007543) that exceeds the Transco FERC Tariff minimum of seven (7) pounds of water vapor per million cubic feet as required by Section 3(c)(vi) of the General Terms and Conditions (GT&C) of Transco’s Tariff. 
 
Consistent with Section 3(d) of Transco’s GT&C, all shippers receiving gas from the location below will be reduced to EPSQ effective for gas day September 6, 
2026
 ID1 cycle. Gas scheduling and flow will not be available until the gas conforms to Transco’s Tariff gas quality.
 
Location ID 
 
Location Name
 
Flow Direction
 
9007543
 
LIVE OAK KARON M1345
 
Receipt
 
If you have any questions, please contact your Transportation Services Representative.
Transco

Non-Tariff Quality Gas at PETTUS OUTLET M3649

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Pipeline: Transco
Notice: Non-Tariff Quality Gas at PETTUS OUTLET M3649
Posted: 09/06/2026 09:32:06 CDT
Notice ID: 17246114

TRANSCONTINENTAL GAS PIPE LINE COMPANY, LLC

Critical:
 Y

Notice Eff Date:
 09/06/2026

Notice Eff Time:
 09:32:06 CDT

Notice End Date:
 

Notice End Time:
 

Notice ID:
 17246114

Notice Stat Desc:
 Supersede

Notice Type Desc:
 Gas Qual

Post Date:
 09/06/2026

Post Time:
 09:32:06 CDT

Prior Notice:
 17246110

Reqrd Rsp Desc:
 Immediate response required of an operational nature may be required of impacted shippers

Rsp Date:
 

Rsp Time:
 

TSP:
 007933021

TSP Name:
 TRANSCONTINENTAL GAS PIPE LINE COMPANY, LLC

Notice Text: 
Subject: 
Non-Tariff Quality Gas at PETTUS OUTLET M3649
Transco is receiving gas at the PETTUS OUTLET M3649 (Location ID 9007543) that exceeds the Transco FERC Tariff minimum of seven (7) pounds of water vapor per million cubic feet as required by Section 3(c)(vi) of the General Terms and Conditions (GT&C) of Transco’s Tariff. 
 
Consistent with Section 3(d) of Transco’s GT&C, all shippers receiving gas from the location below will be reduced to EPSQ effective for gas day September 6, 
2026
 ID1 cycle. Gas scheduling and flow will not be available until the gas conforms to Transco’s Tariff gas quality.
 
Location ID 
 
Location Name
 
Flow Direction
 
9007543
 
PETTUS OUTLET M3649
Receipt
 
If you have any questions, please contact your Transportation Services Representative.
Gas Transmission Northwest

UPDATED: CAPACITY REDUCTION: GTN – Flow Past Kingsgate (Posted: 9/2/26)

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Notice Category: Critical
Notice Type: Maint
Notice Status: Supersede
Posting Date/Time: 09/02/2026 16:50
Notice Eff Date/Time: 09/02/2026 16:50
Prior Notice ID: 1626

Subject: UPDATED: CAPACITY REDUCTION:  GTN – Flow Past Kingsgate (Posted: 9/2/26)
Texas Eastern Transmission (TETCO)

09/05/2026- TE Pipeline Conditions for 09/06/2026

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name: Texas Eastern Transmission, LP
Subject: TE Pipeline Conditions for 09/06/2026
Notice Type: Capacity Constraint
Critical Notice Description: Critical notice
Notice Status Description: Initiate
Notice Effective Date: 09/06/2026
Notice End Date: 09/07/2026
Posting Date: 09/05/2026
Notice Identifier: 182608
Required Response Indicator Description: No response required

For Gas Day September 6, 2026, Texas Eastern (TE) has approved and scheduled nominations at each pipeline segment and meter station up to TE's operational capacity. The following locations have been restricted due to requested nominations exceeding TE's operational capacity:
Restricted Locations
Scheduled and Sealed
Priority % Restricted
Notes
TABS
North of Berne
Meter 75919 Deliveries
N/A
100%
100%
87%
Rec from AGT & Del West of Lambertville
100%
100%
100%
ISS-1 Injections (1)
N/A
100%
FSS, SS-1 and SS Injections (1)
N/A
100%
30" South of Berne
Berne - Southbound
N/A
100%
100%
Danville - Southbound
N/A
100%
100%
Tompkinsville - Southbound
N/A
100%
100%
Barton - Southbound
N/A
100%
100%
24"
Sarahsville - Southbound
N/A
100%
100%
100%
100%
50%
Unplanned Outage
Five Points - Southbound
N/A
100%
61%
Unplanned Outage
Lebanon
N/A
100%
53%
Unplanned Outage
Lebanon Lateral
N/A
100%
87%
Batesville - Southbound
N/A
100%
77%
Meter 74215 Deliveries
Yes
Access Area
Union Church - Southbound
N/A
100%
54%
New Roads South - Southbound
N/A
100%
94%
White Castle - Southbound
N/A
100%
95%
Longview - Northbound
N/A
100%
31%
Huntsville - Northbound
Yes
Speaks - Southbound
N/A
100%
80%
Angleton West - Northbound
N/A
100%
24%
Vidor East - Northbound
Yes
Gillis - Northbound
N/A
100%
56%
TABS Pool Restrictions - Tolerances
ETX
STX
WLA
ELA
M1-24"
M1-30"
M2-24"
M2-30"
TABS Pool - Length
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
TABS Pool - Short
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
No-Notice Restrictions
OFO / Imbalance Notice
OFO
No DS - M1-24, M1-30, M2-24, M2-30 and M3, issued 9/5/2026. 5% / 500 Dth Tolerance
Action Alert
---
Customer Specific OFO
---
Imbalance Warnings
Stay Balanced - Access Area
FERC Order 698
M2-24, M2-30 and M3
Gas Quality:
Due to gas quality issues, meter 76609 has been shut in and physical receipts at the meter will be unavailable until further notice.  Beginning during the Timely cycle for Gas Day December 6, 2025, and until further notice, TE will restrict receipt nominations at Meter 76609 to -0- Dth/d.
Systemwide Notes:
(1) Beginning 9:00 AM CCT September 5, 2026, through 9:00 AM CCT September 8, 2026, excess injections on all ISS-1, FSS-1, SS-1 and SS contracts will be restricted as well as TT16, TT17, TT24 no-notice balancing, no-notice pre-injection and no-notice payback for prior month.
Shippers in all Texas Eastern's Access Area Zones and Market Area Zones M1-30, M2-30 and M3 are required to coordinate any imbalance payback through TE's account representative and actual payback quantities may be limited depending on system operations and conditions. If customers do not adhere to imbalance requirements stated above, TE will utilize any provision of its tariff to ensure system integrity including the issuance of customer specific or system wide OFOs.
Please contact your Operations Account Representative should you have any questions.
Steckman Ridge

09/05/2026- SR Storage Conditions for 09/06/2026

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name: Steckman Ridge, LP
Subject: SR Storage Conditions for 09/06/2026
Notice Type: Capacity Constraint
Critical Notice Description: Critical notice
Notice Status Description: Initiate
Notice Effective Date: 09/06/2026
Notice End Date: 09/07/2026
Posting Date: 09/05/2026
Notice Identifier: 182600
Required Response Indicator Description: No response required

Notice Text:
The following restriction will be in place on the Steckman Ridge system for Gas Day September 6, 2026:
Steckman Ridge has restricted a portion of excess injections. No increases in injections will be accepted except to comply with NAESB bump guidelines.
Customers are advised that capacity may become available as the nomination and confirmation process continues throughout the day.
Please contact your Operations Account Representative if you have any questions.
Southeast Supply Header

09/05/2026- SESH Pipeline Conditions for 09/06/2026

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name: Southeast Supply Header, LLC
Subject: SESH Pipeline Conditions for 09/06/2026
Notice Type: Capacity Constraint
Critical Notice Description: Critical notice
Notice Status Description: Initiate
Notice Effective Date: 09/06/2026
Notice End Date: 09/07/2026
Posting Date: 09/05/2026
Notice Identifier: 182598
Required Response Indicator Description: No response required

For Gas Day September 6, 2026, Southeast Supply Header (SESH) has approved and scheduled nominations at each pipeline segment and meter station up to SESH's operational capacity. The following locations have been restricted due to requested nominations exceeding SESH's operational capacity:
Restricted Locations
Scheduled and Sealed
Priority % Restricted
Notes
Gwinville
100%
Gwinville East
100%
OFO / Imbalance Notice
OFO
---
Customer Specific OFO
---
Imbalances Warnings
No DP - System Wide
Systemwide Notes:
SESH has limited operational flexibility to manage imbalances. As a result, SESH requires all delivery point operators to keep actual daily takes out of the system equal to or less than scheduled quantities regardless of their cumulative imbalance position unless otherwise coordinated with your operations account representative.
Customers are advised that capacity may become available as the nomination and confirmation process continues throughout the day.
Please contact your Operations Account Representative should you have any questions.
Great Lakes Gas Transmission

UPDATED: CAPACITY REDUCTION GLGT – Emerson Eastbound (Posted: 9/2/26)

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Notice Category: Critical
Notice Type: Maint
Notice Status: Supersede
Posting Date/Time: 09/02/2026 14:25
Notice Eff Date/Time: 09/02/2026 14:25
Prior Notice ID: 1217

Subject: UPDATED: CAPACITY REDUCTION GLGT – Emerson Eastbound (Posted: 9/2/26)
Iroquois Gas Transmission

Capacity Constraint

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Critical Notice Effective Timely Cycle, Gas Day September 6, 2026, Iroquois nominations are at capacity and sealed from all increases for the following location(s): -       Brookfield Interconnect with Algonquin Gas Transmission. In addition, the following capacity has been reduced: -       Park, Interruptible and Secondary receipt nominations at the Brookfield Interconnect are reduced by 100%. Customers will be advised if further capacity becomes available during the day as volumes are nominated and confirmed. Please contact your account representative or Gas Control for further information. End date 09/07/2026 09:00 CCT
Texas Eastern Transmission (TETCO)

09/04/2026- TE Pipeline Conditions for 09/05/2026

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name: Texas Eastern Transmission, LP
Subject: TE Pipeline Conditions for 09/05/2026
Notice Type: Capacity Constraint
Critical Notice Description: Critical notice
Notice Status Description: Initiate
Notice Effective Date: 09/05/2026
Notice End Date: 09/06/2026
Posting Date: 09/04/2026
Notice Identifier: 182577
Required Response Indicator Description: No response required

For Gas Day September 5, 2026, Texas Eastern (TE) has approved and scheduled nominations at each pipeline segment and meter station up to TE's operational capacity. The following locations have been restricted due to requested nominations exceeding TE's operational capacity:
Restricted Locations
Scheduled and Sealed
Priority % Restricted
Notes
TABS
North of Berne
Meter 75919 Deliveries
N/A
100%
100%
87%
Rec from AGT & Del West of Lambertville
100%
100%
100%
ISS-1 Injections (1)
N/A
100%
FSS, SS-1 and SS Injections (1)
N/A
100%
30" South of Berne
Berne - Southbound
N/A
100%
100%
Danville - Southbound
N/A
100%
100%
Tompkinsville - Southbound
N/A
100%
100%
Barton - Southbound
N/A
100%
100%
24"
Sarahsville - Southbound
N/A
100%
100%
100%
100%
Unplanned Outage
Five Points - Southbound
N/A
100%
61%
Unplanned Outage
Lebanon
N/A
100%
53%
Unplanned Outage
Lebanon Lateral
N/A
100%
94%
Batesville - Southbound
N/A
100%
45%
Meter 74215 Deliveries
Yes
Access Area
Union Church - Southbound
N/A
100%
54%
New Roads South - Southbound
N/A
100%
95%
White Castle - Southbound
N/A
100%
95%
Longview - Northbound
N/A
100%
31%
Huntsville - Northbound
Yes
Speaks - Southbound
N/A
100%
82%
Angleton West - Northbound
N/A
100%
36%
Vidor East - Northbound
Yes
Gillis - Northbound
N/A
100%
54%
TABS Pool Restrictions - Tolerances
ETX
STX
WLA
ELA
M1-24"
M1-30"
M2-24"
M2-30"
TABS Pool - Length
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
TABS Pool - Short
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
1% or 1,000
No-Notice Restrictions
OFO / Imbalance Notice
OFO
No DS - M1-24, M1-30, M2-24, M2-30 and M3, issued 9/5/2026. 5% / 500 Dth Tolerance
Action Alert
---
Customer Specific OFO
---
Imbalance Warnings
Stay Balanced - Access Area
FERC Order 698
M2-24, M2-30 and M3
Gas Quality:
Due to gas quality issues, meter 76609 has been shut in and physical receipts at the meter will be unavailable until further notice.  Beginning during the Timely cycle for Gas Day December 6, 2025, and until further notice, TE will restrict receipt nominations at Meter 76609 to -0- Dth/d.
Systemwide Notes:
(1) Beginning 9:00 AM CCT September 5, 2026, through 9:00 AM CCT September 8, 2026, excess injections on all ISS-1, FSS-1, SS-1 and SS contracts will be restricted as well as TT16, TT17, TT24 no-notice balancing, no-notice pre-injection and no-notice payback for prior month.
Shippers in all Texas Eastern's Access Area Zones and Market Area Zones M1-30, M2-30 and M3 are required to coordinate any imbalance payback through TE's account representative and actual payback quantities may be limited depending on system operations and conditions. If customers do not adhere to imbalance requirements stated above, TE will utilize any provision of its tariff to ensure system integrity including the issuance of customer specific or system wide OFOs.
Please contact your Operations Account Representative should you have any questions.
Steckman Ridge

09/04/2026- SR Storage Conditions for 09/05/2026

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name: Steckman Ridge, LP
Subject: SR Storage Conditions for 09/05/2026
Notice Type: Capacity Constraint
Critical Notice Description: Critical notice
Notice Status Description: Initiate
Notice Effective Date: 09/05/2026
Notice End Date: 09/06/2026
Posting Date: 09/04/2026
Notice Identifier: 182575
Required Response Indicator Description: No response required

Notice Text:
The following restriction will be in place on the Steckman Ridge system for Gas Day September 5, 2026:
Steckman Ridge has restricted a portion of excess injections. No increases in injections will be accepted except to comply with NAESB bump guidelines.
Customers are advised that capacity may become available as the nomination and confirmation process continues throughout the day.
Please contact your Operations Account Representative if you have any questions.
Southeast Supply Header

09/04/2026- SESH Pipeline Conditions for 9/5/2026

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name: Southeast Supply Header, LLC
Subject: SESH Pipeline Conditions for 9/5/2026
Notice Type: Capacity Constraint
Critical Notice Description: Critical notice
Notice Status Description: Initiate
Notice Effective Date: 09/05/2026
Notice End Date: 09/06/2026
Posting Date: 09/04/2026
Notice Identifier: 182567
Required Response Indicator Description: No response required

For Gas Day September 5, 2026, Southeast Supply Header (SESH) has approved and scheduled nominations at each pipeline segment and meter station up to SESH's operational capacity. The following locations have been restricted due to requested nominations exceeding SESH's operational capacity:
Restricted Locations
Scheduled and Sealed
Priority % Restricted
Notes
Gwinville
100%
Gwinville East
100%
OFO / Imbalance Notice
OFO
---
Customer Specific OFO
---
Imbalances Warnings
No DP - System Wide
Systemwide Notes:
SESH has limited operational flexibility to manage imbalances. As a result, SESH requires all delivery point operators to keep actual daily takes out of the system equal to or less than scheduled quantities regardless of their cumulative imbalance position unless otherwise coordinated with your operations account representative.
Customers are advised that capacity may become available as the nomination and confirmation process continues throughout the day.
Please contact your Operations Account Representative should you have any questions.
Nautilus Pipeline Company

09/04/2026- Nautilus Force Majeure - Unplanned Outage at Enterprise Neptune plant - Update

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name: Nautilus Pipeline Company, L.L.C.
Subject: Nautilus Force Majeure - Unplanned Outage at Enterprise Neptune plant - Update
Notice Type: Force Majeure
Critical Notice Description: Critical notice
Notice Status Description: Supersede
Notice Effective Date: 09/04/2026
Notice End Date: 12/03/2026
Posting Date: 09/04/2026
Notice Identifier: 182547
Prior Notice Identifier: 182546
Required Response Indicator Description: No response required

Notice Text:
Nautilus has been informed that the Enterprise Neptune plant has resumed processing gas. Nautilus will be working to return upstream system pressures to normal throughout the day.
The previously posted Force Majeure, pursuant to section 25 of the General Terms and Conditions of Nautilus' FERC Gas Tariff, is no longer in effect.
For questions concerning this notice, please contact your Enbridge Offshore account rep at 713-627-6204.
East Tennessee Natural Gas

09/04/2026- ETNG Pipeline Conditions for 9/5/2026

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name: East Tennessee Natural Gas, LLC
Subject: ETNG Pipeline Conditions for 9/5/2026
Notice Type: Capacity Constraint
Critical Notice Description: Critical notice
Notice Status Description: Initiate
Notice Effective Date: 09/05/2026
Notice End Date: 09/06/2026
Posting Date: 09/04/2026
Notice Identifier: 182566
Required Response Indicator Description: No response required

For Gas Day September 5, 2026, East Tennessee Natural Gas (ETNG) has approved and scheduled nominations at each pipeline segment and meter station up to ETNG's operational capacity. The following locations have been restricted due to requested nominations exceeding ETNG's operational capacity:
Restricted Locations
Scheduled and Sealed
Priority % Restricted
Notes
Deliveries To Texas Eastern
100%
100%
Topside South
100%
100%
82%
Fordtown West - Westbound
Yes
Flatwoods East - Westbound
Yes
OFO / Imbalance Notice
OFO
---
Customer Specific OFO
---
Hourly Customer Specific OFO
---
Action Alert
---
Imbalances Warnings
Stay Balanced
Systemwide Notes:
ETNG requires any imbalance payback be coordinated through your Operations Account Representative.
If necessary, ETNG will utilize any provision of its tariff to ensure system integrity including the issuance of customer specific or system wide OFOs.
Effective October 1, 2025, MR 59200 - SNG Whitfield will be restricted to 0 Dth / d until further notice due to SNG pressures being lower than ETNG's typical operating pressure. Also, effective October 1, 2025, MR 59311 - SNG Bradley will be limited to its meter capacity of 31,000 Dth/d.
Customers are advised that capacity may become available as the nomination and confirmation process continues throughout the day.
Please contact your Operations Account Representative should you have any questions.
Iroquois Gas Transmission

Capacity Constraint

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Capacity Constraint Effective Timely Cycle, Gas Day September 5, 2026, nominations are sealed from all increases through the following locations: - Brookfield Interconnect with Algonquin Gas Transmission. In addition, the following capacity has been reduced: - Brookfield Interconnect – Park, Interruptible and Secondary receipt nominations are reduced by 100%. If you have any further questions, please contact the Iroquois Scheduling or Gas Control Group. End date 09/06/2026 09:00 AM CCT
ANR Pipeline (TC Energy)

CAPACITY REDUCTION Michigan Leg North – Bridgman Northbound

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name ANR Pipeline Company
TSP 006958581
Notice Type Description: Planned Service Outage

Notice Stat Desc: Initiate

Prior Notice: 

Critical: Y

Reqrd Rsp Desc: No Response Required
Post

Notice Effective

Notice End



Response
Post Date: 09/04/26

09/04/26

09/20/26
Subject: Subject: CAPACITY REDUCTION Michigan Leg North – Bridgman Northbound
Author: Author: Diana Lopez
Notice Text
ANR has planned pipeline maintenance in the Michigan Leg North area located in Berrien County, Michigan. As a result, capacity will be reduced as follows:

9/14 – 9/19 Bridgman Northbound (LOC #FPBRGMNB):422 MMcf/d (leaving 1,200 MMcf/d)

ANR anticipates this posting may result in Firm Primary, Firm Secondary and Interruptible curtailments. Estimated impact to Firm Primary as follows:

               0% - Based on the Current Net Shipper Nominations

  17% - Based on the Current Contracted MDQ

Any reservation charge credits (RCCs) will be determined per the process set forth in the General Terms and Conditions, Section 6.36 of ANR’s FERC Gas Tariff (“Tariff”). However, ANR will only issue RCCs if ANR is unable to schedule or deliver primary firm nominated capacity as a result of the outage. In the event RCCs are issued as set forth in the Tariff, shippers will receive RCCs based on its 7-day Non-Force Majeure Average Usage Quantity, as defined in Section 6.36.2 of ANR’s Tariff, less any scheduled quantities on the contract. By means of this notice, ANR is establishing which specific Gas Days will be included when determining a shipper’s 7-day Non-Force Majeure Average Usage Quantity pursuant to Section 6.36.2(b) of the Tariff.

 

Please direct any questions to your Account Coordinator, Customer Service Representative, or the Nominations and Scheduling hotline @ 800-827-5267.
Columbia Gas Transmission (TCO)

REVISED: CAPACITY POSTING – ID2 for September 4, 2026

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name Columbia Gas Transmission, LLC
TSP 054748041
Notice Type Description: Capacity Constraint

Notice Stat Desc: Initiate

Prior Notice: 

Critical: Y

Reqrd Rsp Desc: No Response Required
Post

Notice Effective

Notice End



Response
Post Date: 09/04/26

09/04/26

10/04/26
Subject: Subject: REVISED: CAPACITY POSTING – ID2 for September 4, 2026
Author: Author: Tyler King
Notice Text
The following non-firm capacity change is effective Intraday 2 Cycle for Gas Day Friday, September 4, 2026, and Timely Cycle for Gas Day Saturday, September 5, 2026: 

* C41 – TEXAS EASTERN TETCON – * 100,000 (Effective ID2 for 09/04/2026) 

Please contact your Customer Services Representative with any questions.
El Paso Natural Gas (EPNG)

[MAINTENANCE] Updated September 2026 Maintenance

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Pipeline: El Paso Natural Gas (EPNG)
Notice Type: MAINTENANCE
Subject: Updated September 2026 Maintenance
Posted: 09/04/2026 10:55:06AM
Effective: 09/04/2026 10:55:06AM
End Date: 09/05/2026 9:00:00AM

TSP/TSP Name:  8001703-EL PASO NATURAL GAS CO. L.L.C. Critical: Y
Notice Type Desc (1):  MAINTENANCE Notice Type Desc (2):  MAINTENANCE
Notice Eff Date/Time:  09/04/2026 10:55:06AM Notice End Date/Time:  09/05/2026 9:00:00am
Post Date/Time:  9/4/2026 10:55:06 AM Notice ID: 629538
Reqrd Rsp:  5 Rsp Date/Time: 
Notice Stat Desc:  SUPERSEDE Prior Notice:  629529
Subject:  Updated September 2026 Maintenance
Notice Text:
EPNG Maintenance Calendar
September 2026
Seg Area
 
Seg Nbr
 
Flow Dir
 
Location
 
Base Capacity (MDth)
 
Tue
1
 
Wed
2
 
Thu
3
 
Fri
4
 
Sat
5
 
Sun
6
 
Mon
7
 
Tue
8
 
Wed
9
 
Thu
10
 
Fri
11
 
Sat
12
 
Sun
13
 
Mon
14
 
Tue
15
 
Wed
16
 
Thu
17
 
Fri
18
 
Sat
19
 
Sun
20
 
Mon
21
 
Tue
22
 
Wed
23
 
Thu
24
 
Fri
25
 
Sat
26
 
Sun
27
 
Mon
28
 
Tue
29
 
Wed
30
Anadarko
 
690
 
F
 
PLAIN ST
 
756
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
 
 
 
 
 
% Seg Avail
 
756
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
Anadarko
 
715
 
B
 
PLAINS N
 
312
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
 
 
 
 
 
% Seg Avail
 
312
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
Anadarko
 
740
 
B
 
AMAR N
 
292
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
 
 
 
 
 
% Seg Avail
 
292
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
Anadarko
 
740
 
F
 
AMAR S
 
309
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
 
 
 
 
 
% Seg Avail
 
309
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
Anadarko
 
760
 
F
 
DUMAS S
 
310
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
37
 
37
 
37
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
% Seg Avail
 
310
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
88%
 
88%
 
88%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
Anadarko
 
780
 
B
 
DUMAS E
 
170
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
63
 
63
 
63
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
% Seg Avail
 
170
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
63%
 
63%
 
63%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
Lincoln Crossover
 
640
 
B
 
CAPROCK N
 
612
 
163
 
163
 
163
 
68
 
68
 
68
 
68
 
68
 
68
 
68
 
68
 
68
 
68
 
68
 
230
 
230
 
230
 
230
 
68
 
68
 
68
 
68
 
68
 
68
 
68
 
68
 
68
 
68
 
115
 
115
 
 
 
 
 
 
% Seg Avail
 
612
 
73%
 
73%
 
73%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
62%
 
62%
 
62%
 
62%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
81%
 
81%
Lincoln Crossover
 
645
 
B
 
LUSK
 
284
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
 
 
 
 
 
% Seg Avail
 
284
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
Line 1903
 
3000
 
F
 
MOJTHRU
 
463
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
117
 
117
 
117
 
117
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
% Seg Avail
 
463
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
75%
 
75%
 
75%
 
75%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
Mojave Seamless
 
3040
 
F
 
MOJAVE
 
400
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
54
 
54
 
54
 
54
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
% Seg Avail
 
400
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
87%
 
87%
 
87%
 
87%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
North Mainline
 
200
 
F
 
NORTH ML
 
2244
 
820
 
983
 
649
 
649
 
649
 
649
 
649
 
649
 
649
 
649
 
649
 
649
 
649
 
649
 
649
 
649
 
649
 
649
 
649
 
649
 
649
 
961
 
961
 
961
 
961
 
961
 
961
 
961
 
961
 
961
 
 
 
 
 
 
% Seg Avail
 
2244
 
63%
 
56%
 
71%
 
71%
 
71%
 
71%
 
71%
 
71%
 
71%
 
71%
 
71%
 
71%
 
71%
 
71%
 
71%
 
71%
 
71%
 
71%
 
71%
 
71%
 
71%
 
57%
 
57%
 
57%
 
57%
 
57%
 
57%
 
57%
 
57%
 
57%
Permian Virtual Segment
 
940
 
F
 
GUADLUP
 
1168
 
 
 
 
 
 
 
 
 
136
 
136
 
136
 
272
 
272
 
272
 
272
 
136
 
136
 
136
 
136
 
136
 
136
 
136
 
136
 
136
 
136
 
136
 
136
 
136
 
136
 
136
 
136
 
136
 
136
 
136
Permian Virtual Segment
 
940
 
F
 
KEYST ST
 
781
 
229
 
229
 
229
 
229
 
229
 
229
 
229
 
229
 
229
 
229
 
229
 
229
 
229
 
229
 
558
 
558
 
558
 
558
 
229
 
229
 
229
 
229
 
229
 
229
 
229
 
229
 
229
 
229
 
229
 
229
Permian Virtual Segment
 
940
 
F
 
KEYSTAFL
 
750
 
198
 
198
 
198
 
198
 
198
 
198
 
198
 
198
 
198
 
198
 
198
 
198
 
198
 
198
 
527
 
527
 
527
 
527
 
198
 
198
 
198
 
198
 
198
 
198
 
198
 
198
 
198
 
198
 
198
 
198
Permian Virtual Segment
 
940
 
F
 
L2000
 
608
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
130
 
130
 
0
 
0
 
0
 
0
 
0
 
0
 
0
Permian Virtual Segment
 
940
 
F
 
PECOS
 
1195
 
 
 
 
 
 
 
 
 
158
 
158
 
158
 
295
 
295
 
295
 
295
 
158
 
158
 
158
 
158
 
158
 
158
 
158
 
158
 
158
 
158
 
158
 
158
 
158
 
158
 
158
 
158
 
158
 
158
 
158
Permian Virtual Segment
 
940
 
F
 
PUC WAHA
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
Permian Virtual Segment
 
940
 
F
 
WA2CORN
 
734
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Permian Virtual Segment
 
940
 
 
 
314598 (IWARMONU)
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
 
 
 
 
 
% Seg Avail
 
85
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
Permian Virtual Segment
 
940
 
 
 
377034 (ITEXNEUN)
 
76
 
76
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
% Seg Avail
 
76
 
0%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
South Mainline
 
1600
 
F
 
CORN HPW
 
586
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
South Mainline
 
1600
 
F
 
CORN LPW
 
1175
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
191
 
191
South Mainline
 
1600
 
F
 
CORNL2K
 
581
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
106
 
106
 
0
 
0
 
0
 
0
 
0
 
0
 
0
South Mainline
 
1600
 
F
 
CORNTRN
 
150
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
% Seg Avail
 
2492
 
97%
 
97%
 
97%
 
97%
 
97%
 
97%
 
97%
 
97%
 
97%
 
97%
 
97%
 
97%
 
97%
 
97%
 
97%
 
97%
 
97%
 
97%
 
97%
 
97%
 
97%
 
93%
 
93%
 
97%
 
97%
 
97%
 
97%
 
97%
 
89%
 
89%
South Mainline
 
1675
 
F
 
EL PASO
 
1243
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
South Mainline
 
1675
 
F
 
ELPASO C
 
584
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
South Mainline
 
1675
 
F
 
ELPASO E
 
578
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
 
 
 
 
 
% Seg Avail
 
2405
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
South Mainline
 
1760
 
F
 
LORDS B
 
580
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
South Mainline
 
1760
 
F
 
LORDS C
 
574
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
103
 
103
 
0
 
0
 
0
 
0
 
0
 
0
 
0
South Mainline
 
1760
 
F
 
LORDSBRG
 
977
 
202
 
202
 
202
 
202
 
202
 
202
 
202
 
202
 
202
 
202
 
448
 
448
 
448
 
448
 
448
 
448
 
448
 
448
 
448
 
448
 
448
 
448
 
202
 
202
 
202
 
202
 
202
 
202
 
202
 
202
 
 
 
 
 
 
% Seg Avail
 
2131
 
87%
 
87%
 
87%
 
87%
 
87%
 
87%
 
87%
 
87%
 
87%
 
87%
 
75%
 
75%
 
75%
 
75%
 
75%
 
75%
 
75%
 
75%
 
75%
 
75%
 
75%
 
71%
 
82%
 
87%
 
87%
 
87%
 
87%
 
87%
 
87%
 
87%
South Mainline
 
1760
 
 
 
314563 (IPYRAMID)
 
50
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
50
 
50
 
50
 
50
 
50
 
50
 
50
 
50
 
50
 
50
 
50
 
50
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
% Seg Avail
 
50
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
South Mainline
 
1800
 
F
 
BOWIE
 
579
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
South Mainline
 
1800
 
F
 
CIMARRON
 
572
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
101
 
101
 
0
 
0
 
0
 
0
 
0
 
0
 
0
South Mainline
 
1800
 
F
 
DRAGOON
 
710
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
198
 
198
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
% Seg Avail
 
1861
 
96%
 
96%
 
96%
 
96%
 
96%
 
96%
 
96%
 
96%
 
96%
 
96%
 
96%
 
96%
 
96%
 
96%
 
96%
 
96%
 
96%
 
96%
 
96%
 
96%
 
96%
 
91%
 
91%
 
85%
 
85%
 
96%
 
96%
 
96%
 
96%
 
96%
Start Date
 
End Date
 
Region
 
Scheduling Location
 
Maintenance List
 
Base Capacity Dthd
 
Total Reduction Dthd
 
PLM Reduction Dthd
 
FMJ Reduction Dthd
 
Net Dthd
 
Update
09/01/26
 
09/01/26
 
NM
 
NORTH ML
 
Line 1201 pipeline remediation Window Rock to Navajo - Delayed
Williams C Station maintenance - Revised Capacity Impact Dth/d
Seligman C Station equipment failure repair - FMJ Reduction
 
                         2,244,804
 
                                 820,096
 
                                699,391
 
                               120,705
 
    1,424,708
 
09/02/26
 
09/02/26
 
NM
 
NORTH ML
 
Leupp Station maintenance - Revised Capacity Impact Dth/d
Line 1201 pipeline remediation Window Rock to Navajo - Delayed
Williams C Station maintenance - Revised Capacity Impact Dth/d
Seligman C Station equipment failure repair - FMJ Reduction
 
                         2,244,804
 
                                 983,554
 
                                862,849
 
                               120,705
 
    1,261,250
 
09/03/26
 
09/04/26
 
NM
 
NORTH ML
 
Line 1201 pipeline remediation Window Rock to Navajo - Delayed
Williams C Station maintenance - Revised Capacity Impact Dth/d
Seligman C Station equipment failure repair - Completed
 
                         2,244,804
 
                                 649,575
 
                                649,575
 
                                             -
 
    1,595,229
 
09/05/26
 
09/07/26
 
NM
 
NORTH ML
 
Williams C Station maintenance - Revised Capacity Impact Dth/d
 
                         2,244,804
 
                                 649,575
 
                                649,575
 
                                             -
 
    1,595,229
 
09/08/26
 
09/10/26
 
NM
 
NORTH ML
 
Line 1201 pipeline remediation Window Rock to Navajo - Delayed
Leupp 4A inspection
Williams C Station maintenance - Revised Capacity Impact Dth/d
 
                         2,244,804
 
                                 649,575
 
                                649,575
 
                                             -
 
    1,595,229
 
09/11/26
 
09/11/26
 
NM
 
NORTH ML
 
Line 1201 pipeline remediation Window Rock to Navajo - Delayed
Williams C Station maintenance - Revised Capacity Impact Dth/d
 
                         2,244,804
 
                                 649,575
 
                                649,575
 
                                             -
 
    1,595,229
 
09/12/26
 
09/21/26
 
NM
 
NORTH ML
 
Williams C Station maintenance - Revised Capacity Impact Dth/d
 
                         2,244,804
 
                                 649,575
 
                                649,575
 
                                             -
 
    1,595,229
 
09/22/26
 
09/28/26
 
NM
 
NORTH ML
 
Line 1201 pipeline remediation Window Rock to Navajo
Williams C Station maintenance - Revised Capacity Impact Dth/d
 
                         2,244,804
 
                                 961,356
 
                                961,356
 
                                             -
 
    1,283,448
 
09/29/26
 
09/30/26
 
NM
 
NORTH ML
 
Line 1201 pipeline remediation Window Rock to Navajo
Williams C Station maintenance - Revised Capacity Impact Dth/d
Window Rock 2A inspection
 
                         2,244,804
 
                                 961,356
 
                                961,356
 
                                             -
 
    1,283,448
 
09/15/26
 
09/16/26
 
MOJ
 
MOJTHRU
 
Mojave 1A inspection
 
                             463,000
 
                                 117,000
 
                                117,000
 
                                             -
 
        346,000
 
09/17/26
 
09/18/26
 
MOJ
 
MOJTHRU
 
Mojave 2A inspection
 
                             463,000
 
                                 117,000
 
                                117,000
 
                                             -
 
        346,000
 
09/15/26
 
09/16/26
 
MOJ
 
MOJAVE
 
Mojave 1A inspection
 
                             400,000
 
                                    54,000
 
                                  54,000
 
                                             -
 
        346,000
 
09/17/26
 
09/18/26
 
MOJ
 
MOJAVE
 
Mojave 2A inspection
 
                             400,000
 
                                    54,000
 
                                  54,000
 
                                             -
 
        346,000
 
09/01/26
 
09/03/26
 
XO
 
CAPROCK N
 
Caprock 2A equipment failure repair - FMJ Reduction
Lincoln Station maintenance
 
                             612,700
 
                                 163,132
 
                                  94,752
 
                                  68,380
 
        449,568
 
09/04/26
 
09/14/26
 
XO
 
CAPROCK N
 
Caprock 2A equipment failure repair - FMJ Reduction
 
                             612,700
 
                                    68,380
 
                                              -
 
                                  68,380
 
        544,320
 
09/15/26
 
09/18/26
 
XO
 
CAPROCK N
 
Caprock 2A equipment failure repair - FMJ Reduction
Bluewater Station DOT/ESD Tests
 
                             612,700
 
                                 230,668
 
                                162,288
 
                                  68,380
 
        382,032
 
09/19/26
 
09/28/26
 
XO
 
CAPROCK N
 
Caprock 2A equipment failure repair - FMJ Reduction
 
                             612,700
 
                                    68,380
 
                                              -
 
                                  68,380
 
        544,320
 
09/29/26
 
09/30/26
 
XO
 
CAPROCK N
 
Caprock 2A equipment failure repair - FMJ Reduction
Line 1301 cleaning and smart tools Belen to Laguna
 
                             612,700
 
                                 115,756
 
                                  47,376
 
                                  68,380
 
        496,944
 
09/01/26
 
09/30/26
 
XO
 
LUSK
 
Caprock 2A equipment failure repair - FMJ Reduction
 
                             284,900
 
                                    22,350
 
                                              -
 
                                  22,350
 
        262,550
 
09/01/26
 
09/30/26
 
AN
 
PLAINS N
 
Line No. 1102 anomaly repairs Plains to Dimmit - MLV 16 to MLV 14 - FMJ Reduction
 
                             312,900
 
                                 112,900
 
                                              -
 
                               112,900
 
        200,000
 
09/01/26
 
09/06/26
 
AN
 
AMAR N
 
Amarillo 2A equipment failure repair - FMJ Reduction
Dimmitt 5A maintenance
 
                             292,400
 
                                    33,328
 
                                              -
 
                                  33,328
 
        259,072
 
09/07/26
 
09/30/26
 
AN
 
AMAR N
 
Amarillo 2A equipment failure repair - FMJ Reduction
 
                             292,400
 
                                    33,328
 
                                              -
 
                                  33,328
 
        259,072
 
09/01/26
 
09/06/26
 
AN
 
AMAR S
 
Amarillo 2A equipment failure repair - FMJ Reduction
Dimmitt 5A maintenance
Line No. 1102 anomaly repairs Plains to Dimmit - MLV 16 to MLV 14 - FMJ Reduction
 
                             309,500
 
                                    53,853
 
                                              -
 
                                  53,853
 
        255,647
 
09/07/26
 
09/30/26
 
AN
 
AMAR S
 
Amarillo 2A equipment failure repair - FMJ Reduction
Line No. 1102 anomaly repairs Plains to Dimmit - MLV 16 to MLV 14 - FMJ Reduction
 
                             309,500
 
                                    53,853
 
                                              -
 
                                  53,853
 
        255,647
 
09/22/26
 
09/24/26
 
AN
 
DUMAS E
 
Dumas Station DOT/ESD Tests
 
                             170,000
 
                                    63,290
 
                                  63,290
 
                                             -
 
        106,710
 
09/22/26
 
09/24/26
 
AN
 
DUMAS S
 
Dumas Station DOT/ESD Tests
 
                             310,500
 
                                    37,734
 
                                  37,734
 
                                             -
 
        272,766
 
09/01/26
 
09/30/26
 
PR
 
PLAIN ST
 
Plains 7A repair
Plains 8A repair
Plains 11A repair
Plains 13A repair
Plains 14A repair
Plains 15A repair
Plains Station equipment failure repair - FMJ Reduction
 
                             756,100
 
                                 405,923
 
                                              -
 
                               405,923
 
        350,177
 
09/01/26
 
09/01/26
 
PR
 
377034
 
Texaco Eunice Receipt - (ITEXNEUN) - Eunice 3C inspection - Customer reduced to zero Dth/d during this outage
 
                               76,545
 
                                    76,545
 
                                  76,545
 
                                             -
 
                      -
 
09/01/26
 
09/30/26
 
PR
 
314598
 
Monument A Station equipment failure repair - Warren Monument Receipt (IWARMONU) - Customer to zero Dth/d during Monument A Station mechanical failure repair - FMJ Reduction
 
                               85,739
 
                                    85,739
 
                                              -
 
                                  85,739
 
                      -
 
09/01/26
 
09/14/26
 
PR
 
KEYST ST
 
Keystone 4A repair
Keystone 11A repair
Keystone 1B repair
Keystone 2B repair
 
                             781,000
 
                                 229,021
 
                                229,021
 
                                             -
 
        551,979
 
09/15/26
 
09/18/26
 
PR
 
KEYST ST
 
Keystone 4A repair
Keystone 11A repair
Keystone 1B repair
Keystone 2B repair
Keystone Station DOT/ESD Tests
 
                             781,000
 
                                 558,151
 
                                558,151
 
                                             -
 
        222,849
 
09/19/26
 
09/30/26
 
PR
 
KEYST ST
 
Keystone 4A repair
Keystone 11A repair
Keystone 1B repair
Keystone 2B repair
 
                             781,000
 
                                 229,021
 
                                229,021
 
                                             -
 
        551,979
 
09/01/26
 
09/14/26
 
PR
 
KEYSTAFL
 
Keystone 4A repair
Keystone 11A repair
Keystone 1B repair
Keystone 2B repair
 
                             750,400
 
                                 198,391
 
                                198,391
 
                                             -
 
        552,009
 
09/15/26
 
09/18/26
 
PR
 
KEYSTAFL
 
Keystone Station DOT/ESD Tests
 
                             750,400
 
                                 527,538
 
                                527,538
 
                                             -
 
        222,862
 
09/19/26
 
09/30/26
 
PR
 
KEYSTAFL
 
Keystone 4A repair
Keystone 11A repair
Keystone 1B repair
Keystone 2B repair
 
                             750,400
 
                                 198,391
 
                                198,391
 
                                             -
 
        552,009
 
09/01/26
 
09/30/26
 
PR
 
PUC WAHA
 
Puckett Station equipment failure repair - FMJ Reduction
 
                             130,900
 
                                 130,900
 
                                              -
 
                               130,900
 
                      -
 
09/05/26
 
09/07/26
 
PR
 
PECOS
 
Line No.1103 anomaly repairs Pecos River to Guadalupe - FMJ Reduction
 
                         1,195,600
 
                                 158,838
 
                                              -
 
                               158,838
 
    1,036,762
 
Update Cycle 1
09/08/26
 
09/11/26
 
PR
 
PECOS
 
Pecos River Station DOT/ESD Tests
Line No.1103 anomaly repairs Pecos River to Guadalupe - FMJ Reduction
 
                         1,195,600
 
                                 295,605
 
                                136,767
 
                               158,838
 
        899,995
 
Update
09/12/26
 
09/30/26
 
PR
 
PECOS
 
Line No.1103 anomaly repairs Pecos River to Guadalupe - FMJ Reduction
 
                         1,195,600
 
                                 158,838
 
                                              -
 
                               158,838
 
    1,036,762
 
Update
09/05/26
 
09/07/26
 
PR
 
GUADLUP
 
Line No.1103 anomaly repairs Pecos River to Guadalupe - FMJ Reduction
 
                         1,168,300
 
                                 136,461
 
                                              -
 
                               136,461
 
    1,031,839
 
Update Cycle 1
09/08/26
 
09/11/26
 
PR
 
GUADLUP
 
Pecos River Station DOT/ESD Tests
Line No.1103 anomaly repairs Pecos River to Guadalupe - FMJ Reduction
 
                         1,168,300
 
                                 272,841
 
                                136,380
 
                               136,461
 
        895,459
 
Update
09/12/26
 
09/30/26
 
PR
 
GUADLUP
 
Line No.1103 anomaly repairs Pecos River to Guadalupe - FMJ Reduction
 
                         1,168,300
 
                                 136,461
 
                                              -
 
                               136,461
 
    1,031,839
 
Update
09/15/26
 
09/28/26
 
SM
 
CORN LPW
 
Cornudas 3A maintenance - Cancelled
 
                         1,175,500
 
                                               -
 
                                              -
 
                                             -
 
    1,175,500
 
09/29/26
 
09/30/26
 
SM
 
CORN LPW
 
Cornudas 3A maintenance - Cancelled
Hueco Station DOT/ESD Tests
 
                         1,175,500
 
                                 191,169
 
                                191,169
 
                                             -
 
        984,331
 
09/01/26
 
09/07/26
 
SM
 
LORDSBRG
 
Line 1103 pipeline remediation Lordsburg to San Simon - Delayed
San Simon Station equipment failure repair - FMJ Reduction - Revised Capacity Impact Dth/d
 
                             977,700
 
                                 202,515
 
                                              -
 
                               202,515
 
        775,185
 
09/08/26
 
09/10/26
 
SM
 
LORDSBRG
 
Line 1103 pipeline remediation Lordsburg to San Simon - Rescheduled
San Simon Station equipment failure repair - FMJ Reduction - Revised Capacity Impact Dth/d
 
                             977,700
 
                                 202,515
 
                                              -
 
                               202,515
 
        775,185
 
09/11/26
 
09/13/26
 
SM
 
LORDSBRG
 
Line 1103 pipeline remediation Lordsburg to San Simon - MLV 41.5 to MLV 43
San Simon Station equipment failure repair - FMJ Reduction - Revised Capacity Impact Dth/d
 
                             977,700
 
                                 448,139
 
                                245,624
 
                               202,515
 
        529,561
 
09/14/26
 
09/22/26
 
SM
 
LORDSBRG
 
Line 1103 pipeline remediation Lordsburg to San Simon - MLV 41.5 to MLV 43
Line 1103 pipeline remediation Lordsburg to San Simon - MLV 43 to MLV 44 - No current additional capacity impact
San Simon Station equipment failure repair - FMJ Reduction - Revised Capacity Impact Dth/d
 
                             977,700
 
                                 448,139
 
                                245,624
 
                               202,515
 
        529,561
 
09/23/26
 
09/27/26
 
SM
 
LORDSBRG
 
Line 1103 pipeline remediation Lordsburg to San Simon - MLV 43 to MLV 44 - No current additional capacity impact
San Simon Station equipment failure repair - FMJ Reduction - Revised Capacity Impact Dth/d
 
                             977,700
 
                                 202,515
 
                                              -
 
                               202,515
 
        775,185
 
09/28/26
 
09/29/26
 
SM
 
LORDSBRG
 
Line 1103 pipeline remediation Lordsburg to San Simon - MLV 43 to MLV 44 - No current additional capacity impact
San Simon Station equipment failure repair - FMJ Reduction - Revised Capacity Impact Dth/d
 
                             977,700
 
                                 202,515
 
                                              -
 
                               202,515
 
        775,185
 
09/30/26
 
09/30/26
 
SM
 
LORDSBRG
 
Line 1103 pipeline remediation Lordsburg to San Simon - MLV 43 to MLV 44 - No current additional capacity impact
San Simon Station equipment failure repair - FMJ Reduction - Revised Capacity Impact Dth/d
San Simon Station maintenance - Cancelled
 
                             977,700
 
                                 202,515
 
                                              -
 
                               202,515
 
        775,185
 
09/11/26
 
09/22/26
 
SM
 
314563
 
Tri-State Pyramid Generating Delivery - (IPYRAMID) - Customer reduced to zero Dth/d net capacity during Line 1103 pipeline remediation Lordsburg to San Simon - MLV 41.5 to MLV 43 - Outage coordinated with customer
 
                               50,784
 
                                    50,784
 
                                  50,784
 
                                             -
 
                      -
 
09/24/26
 
09/25/26
 
SM
 
DRAGOON
 
Dragoon Station inspection
 
                             710,200
 
                                 198,027
 
                                198,027
 
                                             -
 
        512,173
 
09/01/26
 
09/30/26
 
PR
 
WA2CORN
 
Gresham Station mechanical failure repair - FMJ Reduction
 
                             734,400
 
                                    67,738
 
                                              -
 
                                  67,738
 
        666,662
 
09/01/26
 
09/03/26
 
SM
 
CORN HPW
 
Lordsburg 1B maintenance
Gresham Station mechanical failure repair - FMJ Reduction
 
                             586,300
 
                                    76,968
 
                                     9,230
 
                                  67,738
 
        509,332
 
09/04/26
 
09/30/26
 
SM
 
CORN HPW
 
Lordsburg 1B maintenance
Gresham Station mechanical failure repair - FMJ Reduction
 
                             586,300
 
                                    76,968
 
                                     9,230
 
                                  67,738
 
        509,332
 
09/01/26
 
09/03/26
 
SM
 
LORDS B
 
Lordsburg 1B maintenance
Gresham Station mechanical failure repair - FMJ Reduction
 
                             580,900
 
                                    75,298
 
                                     7,560
 
                                  67,738
 
        505,602
 
09/04/26
 
09/30/26
 
SM
 
LORDS B
 
Lordsburg 1B maintenance
Gresham Station mechanical failure repair - FMJ Reduction
 
                             580,900
 
                                    75,298
 
                                     7,560
 
                                  67,738
 
        505,602
 
09/01/26
 
09/03/26
 
SM
 
BOWIE
 
Lordsburg 1B maintenance
Gresham Station mechanical failure repair - FMJ Reduction
 
                             579,000
 
                                    75,259
 
                                     7,521
 
                                  67,738
 
        503,741
 
09/04/26
 
09/30/26
 
SM
 
BOWIE
 
Lordsburg 1B maintenance
Gresham Station mechanical failure repair - FMJ Reduction
 
                             579,000
 
                                    75,259
 
                                     7,521
 
                                  67,738
 
        503,741
 
09/01/26
 
09/21/26
 
PR
 
L2000
 
El Paso 4D equipment failure repair - Completed
 
                             608,300
 
                                               -
 
                                              -
 
                                             -
 
        608,300
 
09/22/26
 
09/23/26
 
PR
 
L2000
 
El Paso 4D equipment failure repair - Completed
Cimarron Station inspection
 
                             608,300
 
                                 130,539
 
                                130,539
 
                                             -
 
        477,761
 
09/24/26
 
09/30/26
 
PR
 
L2000
 
El Paso 4D equipment failure repair - Completed
 
                             608,300
 
                                               -
 
                                              -
 
                                             -
 
        608,300
 
09/01/26
 
09/21/26
 
SM
 
CORNL2K
 
El Paso 4D equipment failure repair - Completed
 
                             581,200
 
                                               -
 
                                              -
 
                                             -
 
        581,200
 
09/22/26
 
09/23/26
 
SM
 
CORNL2K
 
El Paso 4D equipment failure repair - Completed
Cimarron Station inspection
 
                             581,200
 
                                 106,195
 
                                106,195
 
                                             -
 
        475,005
 
09/24/26
 
09/30/26
 
SM
 
CORNL2K
 
El Paso 4D equipment failure repair - Completed
 
                             581,200
 
                                               -
 
                                              -
 
                                             -
 
        581,200
 
09/01/26
 
09/30/26
 
SM
 
ELPASO E
 
El Paso 4D equipment failure repair - Completed
 
                             578,900
 
                                               -
 
                                              -
 
                                             -
 
        578,900
 
09/01/26
 
09/21/26
 
SM
 
LORDS C
 
El Paso 4D equipment failure repair - Completed
 
                             574,400
 
                                               -
 
                                              -
 
                                             -
 
        574,400
 
09/22/26
 
09/23/26
 
SM
 
LORDS C
 
El Paso 4D equipment failure repair - Completed
Cimarron Station inspection
 
                             574,400
 
                                 103,774
 
                                103,774
 
                                             -
 
        470,626
 
09/24/26
 
09/30/26
 
SM
 
LORDS C
 
El Paso 4D equipment failure repair - Completed
 
                             574,400
 
                                               -
 
                                              -
 
                                             -
 
        574,400
 
09/01/26
 
09/21/26
 
SM
 
CIMARRON
 
El Paso 4D equipment failure repair - Completed
 
                             572,200
 
                                               -
 
                                              -
 
                                             -
 
        572,200
 
09/22/26
 
09/23/26
 
SM
 
CIMARRON
 
El Paso 4D equipment failure repair - Completed
Cimarron Station inspection
 
                             572,200
 
                                 101,574
 
                                101,574
 
                                             -
 
        470,626
 
09/24/26
 
09/30/26
 
SM
 
CIMARRON
 
El Paso 4D equipment failure repair - Completed
 
                             572,200
 
                                               -
 
                                              -
 
                                             -
 
        572,200
 
In addition to planned outages, this report reflects the repairs and maintenance being performed related to Force Majeure events.
Due to the nature of such events, the dates for the associated repairs and maintenance of those events are assumed to extend until the end of the month.
These repairs and maintenance, however, may extend beyond the end of the month including beyond the current year.
More information on these repairs and maintenance will be posted as a Critical Notice under the Notices section of the Informational Postings tab on the EPNG Electronic Bulletin Board.
Gulf South Pipeline

Index 330 Pipeline Maintenance

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Pipeline: Gulf South Pipeline
Notice ID: 5038674
Notice Type: Maintenance
Status: Supersede
Posted: 2026-09-04T10:13:00+00:00
Effective: 2026-09-04T10:15:00+00:00
End: 2026-10-01T09:00:00+00:00
Subject: Index 330 Pipeline Maintenance 

Gulf South Pipeline Notice 5038674
Source Link
All information here is provided as a service and information is not guaranteed to be accurate. PipeRiv is not responsible for any incorrect information.
TSP Name :
Gulf South Pipeline Company, LLC
Category :
Critical
Notice Type Desc :
Maintenance
Notice Stat Desc :
Supersede
Notice ID :
5038674
Prior Notice :
5038475
Reqrd Rsp Desc :
No response required
Subject :
Index 330 Pipeline Maintenance
TSP :
078444247
Post Date/Time :
09/04/2026 10:13:00 AM
Notice Effective Date/Time :
09/04/2026 10:15:00 AM
Notice End Date/Time :
10/01/2026 09:00:00 AM
Response Date/Time :
Critical :
Notice Text :
Updated Date Range:
-------------------------------------------------------------------------------------------------
----------------------------------
Gulf South will be performing maintenance at Index 330 Pipeline.
The following points will be shut-in for the duration of the maintenance:
- Loc 6880 (Henderson - Cecilia)
- Loc 3021 (St Martinville City Gate #3)
- 4 Delta Farmtaps
- 1 ATMOS Farmtap
This maintenance has the potential to impact all services, including Primary Firm Service.
Demand charge credits will not be issued during the maintenance period unless Primary Firm
Service is scheduled down during the Timely Nomination Cycle. Any demand charge credits will be
calculated pursuant to Section 6.25 of the General Terms and Conditions of Gulf South`s NGA Gas
Tariff.
If you have any questions, please contact your customer service representative.
Notice
Page 1 of 1
09/04/2026 10:13:15 AM
Notice
TSP Name :
Gulf South Pipeline Company, LLC
TSP :
078444247
Category :
Critical
Post Date/Time :
09/04/2026 10:13:00 AM
Notice Type Desc :
Maintenance
Notice Effective Date/Time :
09/04/2026 10:15:00 AM
Notice Stat Desc :
Supersede
Notice End Date/Time :
10/01/2026 09:00:00 AM
Notice ID :
5038674
Response Date/Time :
Prior Notice :
5038475
Critical :
Reqrd Rsp Desc :
No response required
Subject :
Index 330 Pipeline Maintenance
Notice Text :
Updated Date Range:
-------------------------------------------------------------------------------------------------
----------------------------------
Gulf South will be performing maintenance at Index 330 Pipeline.
The following points will be shut-in for the duration of the maintenance:
- Loc 6880 (Henderson - Cecilia)
- Loc 3021 (St Martinville City Gate #3)
- 4 Delta Farmtaps
- 1 ATMOS Farmtap
This maintenance has the potential to impact all services, including Primary Firm Service.
Demand charge credits will not be issued during the maintenance period unless Primary Firm
Service is scheduled down during the Timely Nomination Cycle. Any demand charge credits will be
calculated pursuant to Section 6.25 of the General Terms and Conditions of Gulf South`s NGA Gas
Tariff.
If you have any questions, please contact your customer service representative.
09/04/2026 10:13:15 AM
Page 1 of 1
ANR Pipeline (TC Energy)

UPDATED: CAPACITY REDUCTION Southwest Area

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name ANR Pipeline Company
TSP 006958581
Notice Type Description: Planned Service Outage

Notice Stat Desc: Supersede

Prior Notice: 26155052

Critical: Y

Reqrd Rsp Desc: No Response Required
Post

Notice Effective

Notice End



Response
Post Date: 09/04/26

09/04/26

09/29/26
Subject: Subject: UPDATED: CAPACITY REDUCTION Southwest Area
Author: Author: T0001375
Notice Text
Since the last posting, ANR has revised the dates for the maintenance in the Southwest Area in Hansford and Wheeler Counties, Texas and Woodward County, Oklahoma. ANR anticipates this posting may result in Firm Primary, Firm Secondary and Interruptible curtailments. As a result, capacity will be reduced as follows:

9/21 – 9/28 (previously 9/13 – 9/18) EG Hill Northbound (LOC #FPEGHLNB): 74 MMcf/d (leaving 141 MMcf/d)

Estimated impact to Firm Primary as follows:

               

7% - Based on the Current Net Shipper Nominations

              32% - Based on the Current Contracted MDQ

9/21 – 9/28 (previously 9/13 – 9/18) Mooreland Northbound (LOC #FPMORLNB): 71 MMcf/d (leaving 135 MMcf/d)

Estimated impact to Firm Primary as follows:

13% - Based on the Current Net Shipper Nominations

               32% - Based on the Current Contracted MDQ

               

9/21 – 9/28 (previously 9/13 – 9/18) Custer Northbound (LOC #FPCSTRNB): 7 MMcf/d (leaving 33 MMcf/d)

Estimated impact to Firm Primary as follows:

0% - Based on the Current Net Shipper Nominations

               0% - Based on the Current Contracted MDQ

Any reservation charge credits (RCCs) will be determined per the process set forth in the General Terms and Conditions, Section 6.36 of ANR’s FERC Gas Tariff (“Tariff”). However, ANR will only issue RCCs if ANR is unable to schedule or deliver primary firm nominated capacity as a result of the outage. In the event RCCs are issued as set forth in the Tariff, shippers will receive RCCs based on its 7-day Non-Force Majeure Average Usage Quantity, as defined in Section 6.36.2 of ANR’s Tariff, less any scheduled quantities on the contract. 

Please direct any questions to your Account Coordinator, Customer Service Representative, or the Nominations and Scheduling hotline @ 800-827-5267.
Columbia Gas Transmission (TCO)

REVISED: CAPACITY POSTING – ID1 for September 4, 2026

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name Columbia Gas Transmission, LLC
TSP 054748041
Notice Type Description: Capacity Constraint

Notice Stat Desc: Initiate

Prior Notice: 

Critical: Y

Reqrd Rsp Desc: No Response Required
Post

Notice Effective

Notice End



Response
Post Date: 09/04/26

09/04/26

10/04/26
Subject: Subject: REVISED: CAPACITY POSTING – ID1 for September 4, 2026
Author: Author: Jonah Skiles
Notice Text
The following changes are effective Intraday 1 Cycle for Friday, September 4, 2026

----------------------------------------------------------------------------

POINT CONSTRAINTS-- Non-Firm Available Capacity:

---------------------------------------------------------------------------- 

* G8 – EAST LYNN-16 - * Total Capacity (Effective Intraday 1 Cycle, 09/04/2026)

Please contact your Customer Services Representative with any questions.
Columbia Gas Transmission (TCO)

CAPACITY POSTING - TIM for September 5, through September 8, 2026

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name Columbia Gas Transmission, LLC
TSP 054748041
Notice Type Description: Capacity Constraint

Notice Stat Desc: Initiate

Prior Notice: 

Critical: Y

Reqrd Rsp Desc: No Response Required
Post

Notice Effective

Notice End



Response
Post Date: 09/04/26

09/04/26

10/04/26
Subject: Subject: CAPACITY POSTING - TIM for September 5, through September 8, 2026
Author: Author: Jonah Skiles
Notice Text
COLUMBIA GAS TRANSMISSION, LLC DAILY CAPACITY POSTING

Columbia Gas Transmission LLC (TCO) posts projections of anticipated market area restrictions at least 24 hours prior to the time when nominations are due. These advance forecasts are subject to change based on actual operating conditions. Customers desiring non-firm services should submit timely nominations to determine whether the service is available under current conditions.

============================================================================

============================================================================

FORCE MAJEURE / STORAGE CRITICAL / TRANSPORT CRITICAL / OFO / RATABLE TAKES

No Force Majeure is necessary.

* A Critical Day for Storage Injections is necessary beginning Gas Day Saturday, September 5, 2026, and will continue until further notice.Please see Critical Notice ID # 26239009 for details.

No Critical Day for Transport is necessary.

* An Operational Flow Order (OFO) for Receipt Points in Market Areas 26, 30, 35, 41 & 42 is necessary beginning Gas Day Saturday, September 5, 2026, and will continue until further notice. Please see Critical Notice ID # 26239008 for details.

Ratable Takes are not required in any Market Areas; however, power customers should request non-ratable takes by submitting a burn profile through TCeConnects.

============================================================================

============================================================================

PIPELINE RECEIPTS, DELIVERIES, INTERNAL CONSTRAINTS, AND DISPLACEMENT AVAILABILITY

For receipts, deliveries, and internal constraints not specifically listed below, please refer to ebb.tceconnects.com/Info Post/Capacity/Operationally Available for information on available capacity at each receipt and delivery point and ebb.tceconnects.com/Info Post/Capacity/Est Op Avail Cap - Internal Constraint for available non-firm capacity at each internal constraint.

Columbia may, from time to time, have displacement capacity available at various receipt/delivery points. Displacement nominations are scheduled based on operational availability up to an approved amount not to exceed the scheduled volumes in the physical direction of flow of the meter. Please contact your Customer Services, Marketing, or O&L Representative for availability at points not listed on this notice.

============================================================================

============================================================================

----------------------------------------------------------------------------

POINT CONSTRAINTS-- Non-Firm Available Capacity:

---------------------------------------------------------------------------- 

633863 - NFG Hartzfelt Mountain - 11,000

640203 - Wagoner Line K - 25,000

640296 - CLINGERMAN - 0

640297 - Range - Sharp - 0

640496 - Range - Day - 0 

640564 - Amwell - 0

642452 - CMG Majorsville - 0

642569 - Mojo - 0

642831 - Range Mills - 0

642838 - Strabane - 0

642854 - Kryptonite - 0

740178 - Fairfield - REX - 75,000

743064 - NEXUS MR06 - 75,000

743365 - Quarry Road - 25,000

736626 - DPL CENTERVILLE - 10,000

737067 - Darby Plant - 75,000

821590 - THOMAS COFFMAN INC YOUNG - 0 

821917 - A&W-Gandee - 0 

823621 - MOUNTAIN STATE-GRANT - 0

824017- STERLING DRG FETTTY - 0 

824766 - TECHNOLOGY DEVELOPMENT - FIELDS - 0 

825005 - CENTRAL PACIFIC GROUP SNYDER - 0 

826130 - STERLING DRG HARPER - 0 

828516 - DORAN-RAINES #1 - 0

833097 - BOSWELLS TAVERN (75-007219) - 0 (Receipts)

833097 - BOSWELLS TAVERN (75-007219) - 100,000

834263 - MCKOWN-JB YOAK LEASE - 0 

835078 - RYAN #702 - 0 

839166 - Patton - 0 

840226 - BenGay MM - 0 

840254 - Vandalia - 0 Total Capacity

842446 - Spencer H Line Sales - 0 

842866 - Green Energy Stonewall - 0

843105 - Transco Chantilly - 50,000

B10 - CAMBRIDGE-9 - 20,000

B15 - UNIONVILLE-35 - 10,000

B17 - HIGHLAND-36 - 20,000

B18 - MILFORD-21 - 0

B9 - BROAD RUN-19 - 0 (Receipts)

B9 - BROAD RUN-19 - 0 (Deliveries)

BYBEE - BYBEE - 0 (Deliveries)

C10 - PLEASANT - 0

C14 - WAYNESBURG - 20,000 

C15 - UNIONTOWN-35 - 0

C16 - DELMONT-36 - 0 (Receipts)

C16 - DELMONT-36 - 0 (Deliveries)

C22 - EAGLE-25 - 0

C23 - PENNSBURG-23 - 0

C41 - TEXAS EASTERN TETCON - 0

C45 - Marietta - 0

C9 - HOOKER-5 - 50,000

* CNR06 – CHK Hubball/Horse Ck/NYE – 

09/05/2026 – Total Capacity

09/06/2026 – Total Capacity

09/07/2026 – Total Capacity

09/08/2026 - *0 

E13 - EMPORIA, VA-34 - 0

E17 - MARTINS CREEK - 21 - 0 (Receipts)

E17 - MARTINS CREEK - 21 - 15,000 (Deliveries)

E2 - ROCKVILLE-30 - 0

E3 - DOWNINGTOWN-29 - 0

E9 - YNG WOMANS CK-RENOVO - 0

G8 - EAST LYNN-16 - 0 

MVPWB - MVP Columbia WB - 0 (Receipts)

MVPWB - MVP Columbia WB - 0 (Deliveries)

----------------------------------------------------------------------------

DELIVERY INTERNAL CONSTRAINTS-- Non-Firm Available Capacity:

----------------------------------------------------------------------------

ARTEMAS - Artemas MA25 - 0

BICKBOSW - Bickers MA33 - No Restriction 

CERELANH - Lanham East MA19 - 0 

CERELANW - Lanham West MA19 - 0

CORNHART - Corning East MA20 - 0

CRAWNORT - Crawford North MA8 - 0

CSLOSTRI - Lost River CS MA30 - No Restriction

DELMONSO - Delmont South MA36 - 10,000

DOWNEAST - Downingtown East MA24 - 25,000

GRENCSTL - Greencastle MA25 - No Restriction

HELLHANO - Hellertown MA22 - 0

HIGHLAND - Highland MA38 - 10,000

HOPEWELL - Hopewell MA33 - No Restriction

INDEGLAS - Corning West MA20 - 5,548

KAEAST - KA East MA17 - 0

LANPKA - Lanham PKA MA19 - 0

LEACHSEG - Leach MA19 - No Restriction

LOUDOUN - Loudoun MA28 - No Restriction

LOUISA - Louisa MA33 - No Restriction 

MA1SEG - Pavonia to Toledo - 10,000 

MA3SEG - Lima MA3 - 10,000 

MA6SEG - Dayton MA6 – 20,000

MA7SEG - Sandusky MA7 - 60,000 

NORTKENT - Northern Kentucky OA6 - No Restriction

PTJRWARW - Wagoner East MA21 - No Restriction

RUTLEDGE - Rutledge North MA28 - 50,000

SENECA - Seneca MA30 - No Restriction

----------------------------------------------------------------------------

RECEIPT INTERNAL CONSTRAINTS-- Non-Firm Available Capacity:

----------------------------------------------------------------------------

A03LINEH - Cobb Line H MA18 - No Restriction

A03LOW - Cobb Northwest MA18 - No Restriction

A03NORTH - Cobb Northeast MA40 - No Restriction

A03SOUTH - Cobb South MA18 - No Restriction

ADALSMIF - Smithfield to Adaline MA35 - 0

ALLIAREC - Alliance Receipts MA4 - 20,000

BOLDMAN - Boldman MA16 - 0

* CHSTKENO - Line P North MA16 – 

09/05/2026 – 25,000

09/06/2026 – 25,000

09/07/2026 -25,000

09/08/2026 - *0

CLENWAYN - Clendenin to Waynesburg MA35 – 0

COBBA03 - Cobb CS MA18 - No Restriction

CRAWSOUT - Crawford South MA8 - No Restriction

DELMRENO - Delmont MA36 - No Restriction

DOWNWEST - Downingtown West MA24 - 0

EASTON - Easton MA21 - 0

GRANHAML - KA High MA19 - 25,000

HANCOCK - Hancock MA20 - 0

KA1SCBYB - KA1 Station Camp MA13 - 5,500

KAWEST - KA West MA17 - 0

LEBANON - Lebanon MA6 - 50,000 

LONEOAKA - Lone Oak A MA41 - 0

LONEOAKB - Lone Oak B MA41 - 0 

LXPSEG - LXPSEG MA41 - 0

MAYTHUFF - KA Low MA16 - 0 

MXPSEG - MXPSEG MA42 - 0

RUTSOUTH - Rutledge South MA28 - 0 

SHERWODA - Sherwood A MA42 - 0

SHERWODB - Sherwood B MA42 - 100,000 

SMITHFLD - Smithfield MA35 - 0

TANNDELM - Line 1711 MA35 - 0

WALGROVE - Walgrove MA18 - No Restriction

WAYNESNO - Waynesburg North MA35 - 0

 

----------------------------------------------------------------------------

DISPLACEMENT AVAILABILITY-- Non-Firm Available Capacity:

----------------------------------------------------------------------------

843067 - Cornwell - 100,000 

C14 - WAYNESBURG - 30,000

C22 - EAGLE-25 - 25,000

C23 - PENNSBURG-23 - 0

C4 - TETCO LEBANON-6 - 0

E2 - ROCKVILLE-30 - 0

LOUDOUN - LOUDOUN LNG - 0

----------------------------------------------------------------------------

TRANSFER METERS-- Non-Firm Available Capacity:

----------------------------------------------------------------------------

TMBOSWLL - TM Boswells Tavern MA33 - 500,000

TMBRDRUN - TM Broad Run MA19 - 500,000

TMCEREDO - TM Ceredo MA19 - 500,000

TMCHANTY - TM Chantilly MA30 - 500,000

TMEAGLE - TM Eagle MA25 - 500,000

TMLEACH - TM Leach MA19 - 500,000

TMLOSTRI - TM Lost River MA30 - 500,000

TMLOUDN - TM Loudoun MA30 - 500,000

TMLXP - TM LXP MA41 - 500,000

TMMXP - TM MXP MA42 - 500,000

----------------------------------------------------------------------------

LOGICAL METERS-- Non-Firm Available Capacity:

----------------------------------------------------------------------------

MLAPLGRV – Mainline Apple Grove - 500,000

MLCRWFRD - Mainline Crawford - 500,000

MLDRYCRE - Mainline Dry Creek - 500,000

MLEAGLE - Mainline Eagle - 500,000

MLLEACH - Mainline Leach - 500,000

MLLOUDOU - Mainline Loudoun - 500,000

MLLXPMAJ - Mainline LXP Majorsville - 500,000

MLNEWALB - Mainline New Albany - 500,000 

MLPETERS - Mainline Petersburg - 500,000

MLSDRCRK - Mainline Saunders Creek - 500,000

----------------------------------------------------------------------------

DUE PIPE AND DUE SHIPPER AVAILABILITY:

----------------------------------------------------------------------------

OP AREA 01 - Due Pipe - 0, Due Shipper - No Restriction

OP AREA 02 - Due Pipe - 0, Due Shipper - No Restriction

OP AREA 03 - Due Pipe - 0, Due Shipper - No Restriction

OP AREA 04 - Due Pipe - 0, Due Shipper - No Restriction 

OP AREA 05 - Due Pipe - 0, Due Shipper - No Restriction

OP AREA 06 - Due Pipe - 0, Due Shipper - No Restriction

OP AREA 07 - Due Pipe - 0, Due Shipper - No Restriction

OP AREA 08 - Due Pipe - 0, Due Shipper - No Restriction 

OP AREA 10 - Due Pipe - 0, Due Shipper - No Restriction

============================================================================

============================================================================

PAL & IT BUSINESS

Representatives are available daily to discuss PAL transactions with customers who have executed Master PAL Agreements. (Reminder: Each PAL transaction including rate, term, quantity and point(s) must be provided for and approved on the Appendix A under the Master PAL Agreement).Customers who are interested in discounted PAL transactions for next-day or long-term park and/or lend transactions or daily discounted IT paths should contact Diana Roberts at 832-320-5454 (ICE droberts6) or Adam Herndon at 832-689-4510 (ICE adherndon) for more information.

AUTO PAL AVAILABILITY

Effective with EVENING Cycle for each Gas Day, Auto Parks/Loans will be limited to +/-5,000 Dth.Customers are reminded the intent of AutoPAL service is to utilize nominal quantities to resolve pool imbalances that result from upstream or downstream reductions during the cycle.This service should not be used for parking or loaning large quantities.

The following services are eligible for Auto Park/Loan Paybacks and Auto Loan/Park Withdrawals:

IPP

SPP

A01 - Kenova

A02 - Flat Top

A03 - Cobb

A04 - Alexander 

A05 - Delmont 

A06 - McClellandtown

A08 - Crawford

A09 - York 

A10 - Dungannon 

A11 - Binghamton

A12 - Mountaineer Xpress

* Denotes a change from previous posting
Columbia Gas Transmission (TCO)

Critical Day for Storage Injections, Effective Saturday, September 5, 2026

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name Columbia Gas Transmission, LLC
TSP 054748041
Notice Type Description: Storage

Notice Stat Desc: Initiate

Prior Notice: 

Critical: Y

Reqrd Rsp Desc: No Response Required
Post

Notice Effective

Notice End



Response
Post Date: 09/04/26

09/04/26

10/04/26
Subject: Subject: Critical Day for Storage Injections, Effective Saturday, September 5, 2026
Author: Author: Tyler King
Notice Text
Columbia Gas Transmission, LLC (TCO) notifies customers that Critical Days for storage injections are necessary effective Gas Day Saturday, September 5, 2026, and continuing until further notice.

 

Based on forecasted supply, reduced market demand, above-average storage levels, and firm storage injection requirements, Transporter projects that all available storage injection capacity will be required to meet firm service obligations. Transporter projects no availability of interruptible storage injection services. Due pipe nominations will be scheduled to zero. Storage withdrawal services are not impacted by this notice.

 

The following daily penalties will apply:

 

FSS MDIQ

 

-Shipper shall pay a penalty of $5.00 per Dth for all quantities injected in excess of 110% of the applicable Contract MDIQ.

 

FSS SCQ

 

-Shipper shall pay a penalty of $5.00 per Dth for all quantities injected in excess of its SCQ.

 

The following monthly penalties will apply:

 

FSS MMIQ

 

-Shipper shall pay a penalty of $5.00 per Dth for all quantities injected in excess of 105% of the applicable MMIQ.

 

This notice describes the events leading up to the declaration of a Critical Day, as required in General Terms and Conditions, Section 19.7 of Columbia Gas Transmission's FERC Gas Tariff.

 

Please contact your Customer Services Representative with any questions.
Florida Gas Transmission

[Florida Gas Transmission] [Operational Alert] Overage Alert Day 20% Tolerance

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Pipeline: Florida Gas Transmission
Notice ID: 68392
Notice Type: Operational Alert
Subject: Overage Alert Day 20% Tolerance
Posted: Sep 4 2026 6:32 AM
Effective: Sep 4 2026 9:00 AM
End Date: Sep 5 2026 9:00 AM

Notice ID: 68392
Notice Type: Operational Alert
Critical: Y
Notice Status Description: Initiate
Reqrd Rsp Desc: No Response Required
Posting Date/Time: Sep 4 2026 6:32 AM
Subject: Overage Alert Day 20% Tolerance
Notice Effective Date/Time: Sep 4 2026 9:00 AM
Notice End Date/Time: Sep 5 2026 9:00 AM
Notice Text: 90-degree temperatures are forecasted in Florida over the next several days; therefore, for the gas day of September 4, 2026, FGT would like to notify their customers in the FGT Market Area that it is issuing an Overage Alert Day at 20% (Twenty Percent) tolerance.For the gas day of September 4, 2026, FGT will not interrupt previously scheduled Market Area ITS-1 service below the elapsed prorated scheduled quantity.FGT will continue to monitor hourly and daily takes. Please closely monitor your scheduled point quantities versus actual burn point quantities.
Tennessee Gas Pipeline (TGP)

OFO DAILY CD1 DS219 EFF 9-5 LIFTED 9-8

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Interstate
Other
Midstream
Informational Postings
Capacity
Gas Electric Coordination
Gas Quality
Index of Customers
Locations
Notices
Posted Imbalances
Regulatory
Standards of Conduct
Tariff
Transactional Reporting
Info Lookup
Other
Downloads
Search
Customer Activities
Site Map
	
	
NOTICE DETAIL
	
PDF
TEXT
Return To Results
TSP/TSP Name:  1939164-TENNESSEE GAS PIPELINE	Critical: Y
Notice Type Desc (1):  OPERATIONAL FLOW ORDER	Notice Type Desc (2):  OFO
Notice Eff Date/Time:  09/04/2026 6:40:20AM	Notice End Date/Time:  09/05/2026 9:00:00am
Post Date/Time:  9/4/2026 6:40:20 AM	Notice ID: 403974
Reqrd Rsp:  1	Rsp Date/Time:  9/4/2026 12:00:00 AM
Notice Stat Desc:  SUPERSEDE	Prior Notice:  403291
Subject:  OFO DAILY CD1 DS219 EFF 9-5 LIFTED 9-8
Notice Text:

OFO DAILY CRITICAL DAY 1 DS OF STA 219 EFFECTIVE 9-5-2026

 

Due to forecasted milder weather with associated lesser demand moving into the Northeast areas of its system, in order to protect the operational integrity of its system, effective for the Gas Day (“GD”) of Saturday, September 5, 2026 Tennessee Gas Pipeline Company, L.L.C. (“Tennessee”) is implementing an OFO Daily Critical Day (“CD”) 1 for all areas East of STA 219 for over-deliveries into the system or under-takes out of the system pursuant to Article X of the General Terms and Conditions of Tennessee's FERC NGA Gas Tariff.  Tennessee is lifting the OFO Daily Critical Day 1 for all areas East of STA 219 effective for the Gas Day of Tuesday, September 8, 2026 and until further notice.

 

This OFO will be effective for LMS-PA, SA contracts acting as balancing parties and LMS-MA Balancing Parties only.

 

Please refer to the table below for the affected areas and dates, and the actions required:

Zone

	

GD 9-4-26

	

GD 9-5-26 through 9-7-2026

	

GD 9-8-26 and until further notice




Zone 0

	

No OFO

	

No OFO

	

No OFO




Zone L

	

Critical Day 1

500 Line Only

(Includes Segments 527, 529, 530 Only)

·         Receipts do not underdeliver

·         Deliveries do not overtake

	

Critical Day 1

500 Line Only

(Includes Segments 527, 529, 530 Only)

·         Receipts do not underdeliver

·         Deliveries do not overtake

	

Critical Day 1

500 Line Only

(Includes Segments 527, 529, 530 Only)

·         Receipts do not underdeliver

·         Deliveries do not overtake




Zone 1

	

Critical Day 1

500 Line Only

(Includes Segments 534, 539 Only)

·         Receipts do not underdeliver

·         Deliveries do not overtake

	

Critical Day 1

500 Line Only

(Includes Segments 534, 539 Only)

·         Receipts do not underdeliver

·         Deliveries do not overtake

	

Critical Day 1

500 Line Only

(Includes Segments 534, 539 Only)

·         Receipts do not underdeliver

·         Deliveries do not overtake




Zone 2

	

No OFO

	

No OFO

	

No OFO




Zone 3

	

No OFO

	

No OFO

	

No OFO




Zone 4

	

No OFO

	

Critical Day 1

All Areas East and North of STA 219 Only

·         Receipts do not overdeliver

·         Deliveries do not undertake

	

No OFO




Zone 5

	

No OFO

	

Critical Day 1

All Areas

·         Receipts do not overdeliver

·         Deliveries do not undertake

	

No OFO




Zone 6

	

No OFO

	

Critical Day 1

All Areas

·         Receipts do not overdeliver

·         Deliveries do not undertake

	

No OFO

CD 1 PENALTY: $5.00 + applicable Regional Daily Spot Price per Dth for quantities in excess of the tolerance
CD 1 TOLERANCE:  Greater of 2% of scheduled quantities or 500 Dth

 

Balancing between OBA points in separate pipeline regions or across meters not located in the OFO area will not be permitted.

 

In the event this OFO is not sufficient to maintain the operational integrity of its system, Tennessee may escalate to calling a Critical Day II, a Balancing Alert, Meter Specific OFO(s) or Hourly OFO(s), or taking any other actions that may be permitted or required by Tennessee's Tariff.  

 

Please contact your Scheduling Representative if you have any questions.

..
Transco

UPDATE - Job 242501 Station 77 Eminence Storage Planned Outage and Maintenance Summary

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Pipeline: Transco
Notice: UPDATE - Job 242501 Station 77 Eminence Storage Planned Outage and Maintenance Summary
Posted: 09/03/2026 15:55:37 CDT
Notice ID: 17238068

TRANSCONTINENTAL GAS PIPE LINE COMPANY, LLC

Critical:
 Y

Notice Eff Date:
 09/03/2026

Notice Eff Time:
 15:55:37 CDT

Notice End Date:
 

Notice End Time:
 

Notice ID:
 17238068

Notice Stat Desc:
 Supersede

Notice Type Desc:
 Maint

Post Date:
 09/03/2026

Post Time:
 15:55:37 CDT

Prior Notice:
 17154952

Reqrd Rsp Desc:
 Immediate response required of an operational nature may be required of impacted shippers

Rsp Date:
 

Rsp Time:
 

TSP:
 007933021

TSP Name:
 TRANSCONTINENTAL GAS PIPE LINE COMPANY, LLC

Notice Text: 
Subject: 
UPDATE - Job 242501 Station 77 Eminence Storage Planned Outage and Maintenance Summary
Transco will be performing annual fall shut in tests and valve replacements at the Eminence Storage facility, currently scheduled from 
September 28, 2026
 through 
October 10, 2026
.  
During this period, the Eminence Storage Field will not be available for service to allow for required DOT compliance testing work to be performed. Services under ESS rate schedules may not be available for the period due to Operating Conditions resulting from this planned outage.  
If Transco is required to restrict ESS Injection or withdrawal services, additional notice will be provided.   
Additionally, this work will also reduce system flexibility. It is recommended all parties maintain a concurrent balance of receipts and deliveries daily. 
If you have any questions, please contact your Transportation Services representative.
Natural Gas Pipeline (NGPL)

[MAINTENANCE] SEGMENT 20 - GC #1 M/L -ILI TOOL RUNS

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Pipeline: Natural Gas Pipeline (NGPL)
Notice Type: MAINTENANCE
Subject: SEGMENT 20 - GC #1 M/L -ILI TOOL RUNS
Posted: 09/03/2026 2:57:03PM
Effective: 09/03/2026 2:57:03PM
End Date: 09/04/2026 9:00:00AM

TSP/TSP Name:  6931794-NATURAL GAS PIPELINE CO. Critical: Y
Notice Type Desc (1):  MAINTENANCE Notice Type Desc (2):  MAINTENANCE
Notice Eff Date/Time:  09/03/2026 2:57:03PM Notice End Date/Time:  09/04/2026 9:00:00am
Post Date/Time:  9/3/2026 2:57:03 PM Notice ID: 47202
Reqrd Rsp:  1 Rsp Date/Time:  9/3/2026 12:00:00 AM
Notice Stat Desc:  INITIATE Prior Notice: 
Subject:  SEGMENT 20 - GC #1 M/L -ILI TOOL RUNS
Notice Text:
SEGMENT 20 - GULF COAST #1 M/L – ILI TOOL RUNS
 
As posted on Natural's Outage Impact Report (X26-82800) and as part of Natural's ongoing pipeline Integrity Management Program, Natural will perform a series of ILI tool runs on its Gulf Coast #1 mainline south of Compressor Station 341 (CS 341) located in Nueces County, Texas in Segment 20 of Natural's South Texas Zone. Once the data from the tool runs have been analyzed, any remediation work impacting shippers will be posted.
 
As such, effective on the gas days indicated below, the locations listed below will be scheduled accordingly for the duration of this integrity work.
 
LOCATIONS PRIMARY ONLY:
 
LOC 54849      WHISTLEP/NGPL WHISTLE REC NEUCES
LOC 53776      VCP/NGPL MUSTANG M/L 1 NUECES
 
LOCATION UNAVAILABLE:
 
LOC 3886    BANHUB/NGPL BANQUETE HUB BI-DI
 
TOOL RUN DATES:
 
Gas day Tuesday, October 27, 2026 (Cleaning Tool)
Gas day Wednesday, October 28, 2026 (Gauge Tool)
Gas day Thursday, October 29, 2026 (MFL/Caliper Tool)
Gas day Friday, October 30, 2026 (EMAT Tool)
 
Please contact your Account Director or Scheduling Representative if you have any questions.
EGTS

PL-1 Restrictions Termination

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Pipeline: EGTS
Notice ID: 1013355
Subject: PL-1 Restrictions Termination
Notice Type: Notices
Posted: 2026-09-03T19:58:02.937
Effective: 2026-09-05T14:00:00
naesbNoticeTypeDescription: Capacity Constraint
subcategory: Critical
tspDefinedNoticeTypeDescription: PPO
NEXUS Gas Transmission (U.S.)

09/03/2026- NEXUS Pipeline Conditions for 9/4/2026

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name: NEXUS Gas Transmission, LLC (U.S.)
Subject: NEXUS Pipeline Conditions for 9/4/2026
Notice Type: Capacity Constraint
Critical Notice Description: Critical notice
Notice Status Description: Initiate
Notice Effective Date: 09/04/2026
Notice End Date: 09/05/2026
Posting Date: 09/03/2026
Notice Identifier: 182517
Required Response Indicator Description: No response required

For Gas Day September 4, 2026, Nexus Gas Transmission, LLC (NEXUS) has approved and scheduled nominations at each pipeline segment and meter station up to NEXUS's operational capacity. The following locations have been restricted due to requested nominations exceeding NEXUS's operational capacity:
Restricted Locations
Scheduled and Sealed
Priority % Restricted
Notes
TABS
Belle River
N/A
100%
100%
100%
100%
100%
100%
42%
Due to DTE Posted Outage
Ypsilanti
N/A
100%
100%
100%
100%
100%
100%
38%
Due to DTE Posted Outage
Salinville
Yes
OFO / Imbalance Notice
OFO
---
Customer Specific OFO
No DP - issued 8/20/2026. 2% / 500 Dth/d Tolerance
Imbalances Warnings
Stay Balanced
Gas Quality:
NEXUS has been informed by TETCO that the gas quality entering TE's system from meters N4714, N4733, and N4915 continues to improve. As a result, the prior notification regarding partial flow reductions beginning September 9, 2026, has been rescinded for these meters. TE will continue to monitor gas entering its system to ensure compliance with TE's gas quality standards in its GT&C. If continued and sustained improvement is not demonstrated, meter operators may be subject to future flow reductions.
Systemwide Notes:
Customers are advised that capacity may become available as the nomination and confirmation process continues throughout the day.
Please contact your Operations Account Representative should you have any questions.
Maritimes & Northeast U.S.

09/03/2026- MNUS Imbalance Notice -- UPDATE

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name: Maritimes & Northeast Pipeline, L.L.C. (U.S.)
Subject: MNUS Imbalance Notice -- UPDATE
Notice Type: Other
Critical Notice Description: Critical notice
Notice Status Description: Supersede
Notice Effective Date: 09/05/2026
Notice End Date: 12/02/2026
Posting Date: 09/03/2026
Notice Identifier: 182507
Prior Notice Identifier: 180501
Required Response Indicator Description: No response required

Notice Text:
Maritimes & Northeast (M&N) has limited operational flexibility to manage imbalances.  Effective 9:00 AM CCT, September 5, 2026, M&N requires all shippers and point operators to keep actual daily takes out of the system equal to or greater than scheduled quantities regardless of their cumulative imbalance position unless otherwise coordinated with your operations account representative.
Correspondingly, effective 9:00 AM CCT, September 5, 2026, the previously posted imbalance notice is no longer in effect.
Additionally, M&N continues to require all Power Plant Operators to provide information mandated by FERC Order No. 698 until further notice. Information required includes the hourly consumption profile of directly connected power generation facilities.
To the extent shippers and/or point operators do not adhere to this requirement,
M&N will utilize any provision of its tariff to ensure system integrity including the issuance of customer specific or system wide OFOs.
This notice will remain in effect until further notice.
Please contact your Operations Account Representative if you have any questions.
Maritimes & Northeast Canada

09/03/2026- MNCA Imbalance Notice -- UPDATE

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name: Maritimes & Northeast Pipeline Limited Partnership (Canada)
Subject: MNCA Imbalance Notice -- UPDATE
Notice Type: Other
Critical Notice Description: Critical notice
Notice Status Description: Supersede
Notice Effective Date: 09/05/2026
Notice End Date: 12/02/2026
Posting Date: 09/03/2026
Notice Identifier: 182508
Prior Notice Identifier: 181662
Required Response Indicator Description: No response required

Notice Text:
Maritimes Canada (MNC) has been experiencing large daily Due Shipper imbalances. Effective for Gas Day September 5, 2026, MNC requires shippers and point operators not to exceed daily due shipper imbalances of 500 GJ or 10% (whichever is greater) regardless of their cumulative imbalances.   As such, MNC will not allow Transaction Type 04 nominations in excess of 500 GJ per contract.
To the extent shippers and/or point operators do not adhere to this requirement, MNC may issue customer specific OFOs pursuant to General Terms and Conditions Section 10, in order to maintain the operational integrity of the system.
This notice will remain in effect until further notice.
Correspondingly, effective 9:00 AM CCT, September 5, 2026, the previously posted imbalance notice is no longer in effect.
Please contact your operations account manager with any questions.
National Fuel Gas Supply

Mercer Compressor Station Outage: September 2026 - Revision 3

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Pipeline: National Fuel Gas Supply
Notice Type: Curtailment, Planned Service Outage, Scheduling Alert
Subject: Mercer Compressor Station Outage: September 2026 - Revision 3
Posted Date/Time: 09/03/2026 9:16:00AM CDT
Effective Date/Time: 09/29/2026 10:00:00AM CDT
End Date/Time: 10/14/2026 9:00:00AM CDT
Notice ID: 1277949
Supersedes Notice ID: 1274343

Mercer Compressor Station Outage: September 2026 - Revision 3

Due to a change in outage scope, available capacity has been updated:

To facilitate the installation of station upgrades, Mercer compressor station will experience an outage beginning gas day 9/29/2026 through gas day 10/13/2026.

For the duration of the outage:

- Net deliveries to TGP - Mercer (412888) and net receipts from TGP - Mercer (420069) will be reduced to 0 dth.
- �Line N South to North capacity will be reduced to 0 dth.
- �A temporary �Line N North to South constraint located on NM50 south of Mercer station will reduce segment capacity to 0 dth.

Primary services are expected to be affected by this outage.

Updates will be provided as available.

********** Prior Notice Below **********

Mercer Compressor Station Outage: September 2026 - Revision 2

Outage dates, duration and available capacity have been updated:

To facilitate the installation of station upgrades, Mercer compressor station will experience an outage beginning gas day 9/29/2026 through gas day 10/13/2026.

For the duration of the outage, net deliveries to TGP - Mercer (412888) will be limited to 30,000 dth, and net receipts from TGP - Mercer (420069) will be reduced to 0.

Additionally, Henderson Sta W to E capacity will be limited to 30,000 dth. Primary services through this segment will not be affected.

Updates will be provided as available.

********** Prior Notice Below **********

Mercer Compressor Station Outage: September 2026 - Revision 1

To facilitate the installation of station upgrades, Mercer compressor station will experience an outage beginning gas day 9/28/2026 through gas day 10/10/2026.

For the duration of the outage, net deliveries to TGP - Mercer (412888) and net receipts from TGP - Mercer (420069) are expected to be reduced to 0.

Updates will be provided as available.

********** Prior Notice Below **********

Mercer Compressor Station Outage - September 2026

To facilitate the installation of station upgrades, Mercer compressor station will experience an outage in September 2026. The outage is expected to occur mid-month.
Duration of the outage will be added in a subsequent revision to this posting.

For the duration of the outage, net deliveries to TGP - Mercer (412888) and net receipts from TGP - Mercer (420069) are expected to be reduced to 0.

Updates and additional detail will be provided as soon as they are available.
Iroquois Gas Transmission

Capacity Constraint

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Capacity Constraint Effective Timely Cycle, Gas Day September 4, 2026, nominations are sealed from all increases through the following locations: - Brookfield Interconnect with Algonquin Gas Transmission. In addition, the following capacity has been reduced: - Brookfield Interconnect – Park, Interruptible and Secondary receipt nominations are reduced by 100%. If you have any further questions, please contact the Iroquois Scheduling or Gas Control Group. End date 09/05/2026 09:00 AM CCT
El Paso Natural Gas (EPNG)

[MAINTENANCE] Updated September 2026 Maintenance

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Pipeline: El Paso Natural Gas (EPNG)
Notice Type: MAINTENANCE
Subject: Updated September 2026 Maintenance
Posted: 09/03/2026 10:04:17AM
Effective: 09/03/2026 10:04:17AM
End Date: 09/04/2026 9:00:00AM

TSP/TSP Name:  8001703-EL PASO NATURAL GAS CO. L.L.C. Critical: Y
Notice Type Desc (1):  MAINTENANCE Notice Type Desc (2):  MAINTENANCE
Notice Eff Date/Time:  09/03/2026 10:04:17AM Notice End Date/Time:  09/04/2026 9:00:00am
Post Date/Time:  9/3/2026 10:04:17 AM Notice ID: 629529
Reqrd Rsp:  5 Rsp Date/Time: 
Notice Stat Desc:  SUPERSEDE Prior Notice:  629522
Subject:  Updated September 2026 Maintenance
Notice Text:
EPNG Maintenance Calendar
September 2026
Seg Area
 
Seg Nbr
 
Flow Dir
 
Location
 
Base Capacity (MDth)
 
Tue
1
 
Wed
2
 
Thu
3
 
Fri
4
 
Sat
5
 
Sun
6
 
Mon
7
 
Tue
8
 
Wed
9
 
Thu
10
 
Fri
11
 
Sat
12
 
Sun
13
 
Mon
14
 
Tue
15
 
Wed
16
 
Thu
17
 
Fri
18
 
Sat
19
 
Sun
20
 
Mon
21
 
Tue
22
 
Wed
23
 
Thu
24
 
Fri
25
 
Sat
26
 
Sun
27
 
Mon
28
 
Tue
29
 
Wed
30
Anadarko
 
690
 
F
 
PLAIN ST
 
756
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
 
 
 
 
 
% Seg Avail
 
756
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
Anadarko
 
715
 
B
 
PLAINS N
 
312
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
 
 
 
 
 
% Seg Avail
 
312
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
Anadarko
 
740
 
B
 
AMAR N
 
292
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
 
 
 
 
 
% Seg Avail
 
292
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
Anadarko
 
740
 
F
 
AMAR S
 
309
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
 
 
 
 
 
% Seg Avail
 
309
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
Anadarko
 
760
 
F
 
DUMAS S
 
310
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
37
 
37
 
37
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
% Seg Avail
 
310
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
88%
 
88%
 
88%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
Anadarko
 
780
 
B
 
DUMAS E
 
170
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
63
 
63
 
63
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
% Seg Avail
 
170
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
63%
 
63%
 
63%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
Lincoln Crossover
 
640
 
B
 
CAPROCK N
 
612
 
163
 
163
 
163
 
68
 
68
 
68
 
68
 
68
 
68
 
68
 
68
 
68
 
68
 
68
 
230
 
230
 
230
 
230
 
68
 
68
 
68
 
68
 
68
 
68
 
68
 
68
 
68
 
68
 
115
 
115
 
 
 
 
 
 
% Seg Avail
 
612
 
73%
 
73%
 
73%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
62%
 
62%
 
62%
 
62%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
81%
 
81%
Lincoln Crossover
 
645
 
B
 
LUSK
 
284
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
 
 
 
 
 
% Seg Avail
 
284
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
Line 1903
 
3000
 
F
 
MOJTHRU
 
463
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
117
 
117
 
117
 
117
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
% Seg Avail
 
463
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
75%
 
75%
 
75%
 
75%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
Mojave Seamless
 
3040
 
F
 
MOJAVE
 
400
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
54
 
54
 
54
 
54
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
% Seg Avail
 
400
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
87%
 
87%
 
87%
 
87%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
North Mainline
 
200
 
F
 
NORTH ML
 
2244
 
820
 
983
 
649
 
649
 
649
 
649
 
649
 
649
 
649
 
649
 
649
 
649
 
649
 
649
 
649
 
649
 
649
 
649
 
649
 
649
 
649
 
961
 
961
 
961
 
961
 
961
 
961
 
961
 
961
 
961
 
 
 
 
 
 
% Seg Avail
 
2244
 
63%
 
56%
 
71%
 
71%
 
71%
 
71%
 
71%
 
71%
 
71%
 
71%
 
71%
 
71%
 
71%
 
71%
 
71%
 
71%
 
71%
 
71%
 
71%
 
71%
 
71%
 
57%
 
57%
 
57%
 
57%
 
57%
 
57%
 
57%
 
57%
 
57%
Permian Virtual Segment
 
940
 
F
 
GUADLUP
 
1168
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
101
 
101
 
101
 
101
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Permian Virtual Segment
 
940
 
F
 
KEYST ST
 
781
 
229
 
229
 
229
 
229
 
229
 
229
 
229
 
229
 
229
 
229
 
229
 
229
 
229
 
229
 
558
 
558
 
558
 
558
 
229
 
229
 
229
 
229
 
229
 
229
 
229
 
229
 
229
 
229
 
229
 
229
Permian Virtual Segment
 
940
 
F
 
KEYSTAFL
 
750
 
198
 
198
 
198
 
198
 
198
 
198
 
198
 
198
 
198
 
198
 
198
 
198
 
198
 
198
 
527
 
527
 
527
 
527
 
198
 
198
 
198
 
198
 
198
 
198
 
198
 
198
 
198
 
198
 
198
 
198
Permian Virtual Segment
 
940
 
F
 
L2000
 
608
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
130
 
130
 
0
 
0
 
0
 
0
 
0
 
0
 
0
Permian Virtual Segment
 
940
 
F
 
PECOS
 
1195
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
123
 
123
 
123
 
123
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Permian Virtual Segment
 
940
 
F
 
PUC WAHA
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
Permian Virtual Segment
 
940
 
F
 
WA2CORN
 
734
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Permian Virtual Segment
 
940
 
 
 
314598 (IWARMONU)
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
 
 
 
 
 
% Seg Avail
 
85
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
Permian Virtual Segment
 
940
 
 
 
377034 (ITEXNEUN)
 
76
 
76
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
% Seg Avail
 
76
 
0%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
South Mainline
 
1600
 
F
 
CORN HPW
 
586
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
South Mainline
 
1600
 
F
 
CORN LPW
 
1175
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
191
 
191
South Mainline
 
1600
 
F
 
CORNL2K
 
581
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
106
 
106
 
0
 
0
 
0
 
0
 
0
 
0
 
0
South Mainline
 
1600
 
F
 
CORNTRN
 
150
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
% Seg Avail
 
2492
 
97%
 
97%
 
97%
 
97%
 
97%
 
97%
 
97%
 
97%
 
97%
 
97%
 
97%
 
97%
 
97%
 
97%
 
97%
 
97%
 
97%
 
97%
 
97%
 
97%
 
97%
 
93%
 
93%
 
97%
 
97%
 
97%
 
97%
 
97%
 
89%
 
89%
South Mainline
 
1675
 
F
 
EL PASO
 
1243
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
South Mainline
 
1675
 
F
 
ELPASO C
 
584
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
South Mainline
 
1675
 
F
 
ELPASO E
 
578
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
 
 
 
 
 
% Seg Avail
 
2405
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
South Mainline
 
1760
 
F
 
LORDS B
 
580
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
South Mainline
 
1760
 
F
 
LORDS C
 
574
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
103
 
103
 
0
 
0
 
0
 
0
 
0
 
0
 
0
South Mainline
 
1760
 
F
 
LORDSBRG
 
977
 
202
 
202
 
202
 
202
 
202
 
202
 
202
 
202
 
202
 
202
 
448
 
448
 
448
 
448
 
448
 
448
 
448
 
448
 
448
 
448
 
448
 
448
 
202
 
202
 
202
 
202
 
202
 
202
 
202
 
202
 
 
 
 
 
 
% Seg Avail
 
2131
 
87%
 
87%
 
87%
 
87%
 
87%
 
87%
 
87%
 
87%
 
87%
 
87%
 
75%
 
75%
 
75%
 
75%
 
75%
 
75%
 
75%
 
75%
 
75%
 
75%
 
75%
 
71%
 
82%
 
87%
 
87%
 
87%
 
87%
 
87%
 
87%
 
87%
South Mainline
 
1760
 
 
 
314563 (IPYRAMID)
 
50
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
50
 
50
 
50
 
50
 
50
 
50
 
50
 
50
 
50
 
50
 
50
 
50
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
% Seg Avail
 
50
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
South Mainline
 
1800
 
F
 
BOWIE
 
579
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
South Mainline
 
1800
 
F
 
CIMARRON
 
572
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
101
 
101
 
0
 
0
 
0
 
0
 
0
 
0
 
0
South Mainline
 
1800
 
F
 
DRAGOON
 
710
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
198
 
198
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
% Seg Avail
 
1861
 
96%
 
96%
 
96%
 
96%
 
96%
 
96%
 
96%
 
96%
 
96%
 
96%
 
96%
 
96%
 
96%
 
96%
 
96%
 
96%
 
96%
 
96%
 
96%
 
96%
 
96%
 
91%
 
91%
 
85%
 
85%
 
96%
 
96%
 
96%
 
96%
 
96%
Start Date
 
End Date
 
Region
 
Scheduling Location
 
Maintenance List
 
Base Capacity Dthd
 
Total Reduction Dthd
 
PLM Reduction Dthd
 
FMJ Reduction Dthd
 
Net Dthd
 
Update
09/01/26
 
09/01/26
 
NM
 
NORTH ML
 
Line 1201 pipeline remediation Window Rock to Navajo - Delayed
Williams C Station maintenance - Revised Capacity Impact Dth/d
Seligman C Station equipment failure repair - FMJ Reduction
 
                         2,244,804
 
                                 820,096
 
                                699,391
 
                               120,705
 
    1,424,708
 
09/02/26
 
09/02/26
 
NM
 
NORTH ML
 
Leupp Station maintenance - Revised Capacity Impact Dth/d
Line 1201 pipeline remediation Window Rock to Navajo - Delayed
Williams C Station maintenance - Revised Capacity Impact Dth/d
Seligman C Station equipment failure repair - FMJ Reduction
 
                         2,244,804
 
                                 983,554
 
                                862,849
 
                               120,705
 
    1,261,250
 
09/03/26
 
09/04/26
 
NM
 
NORTH ML
 
Line 1201 pipeline remediation Window Rock to Navajo - Delayed
Williams C Station maintenance - Revised Capacity Impact Dth/d
Seligman C Station equipment failure repair - Completed
 
                         2,244,804
 
                                 649,575
 
                                649,575
 
                                             -
 
    1,595,229
 
Update Cycle 3
09/05/26
 
09/07/26
 
NM
 
NORTH ML
 
Williams C Station maintenance - Revised Capacity Impact Dth/d
 
                         2,244,804
 
                                 649,575
 
                                649,575
 
                                             -
 
    1,595,229
 
09/08/26
 
09/10/26
 
NM
 
NORTH ML
 
Line 1201 pipeline remediation Window Rock to Navajo - Delayed
Leupp 4A inspection
Williams C Station maintenance - Revised Capacity Impact Dth/d
 
                         2,244,804
 
                                 649,575
 
                                649,575
 
                                             -
 
    1,595,229
 
09/11/26
 
09/11/26
 
NM
 
NORTH ML
 
Line 1201 pipeline remediation Window Rock to Navajo - Delayed
Williams C Station maintenance - Revised Capacity Impact Dth/d
 
                         2,244,804
 
                                 649,575
 
                                649,575
 
                                             -
 
    1,595,229
 
09/12/26
 
09/21/26
 
NM
 
NORTH ML
 
Williams C Station maintenance - Revised Capacity Impact Dth/d
 
                         2,244,804
 
                                 649,575
 
                                649,575
 
                                             -
 
    1,595,229
 
09/22/26
 
09/28/26
 
NM
 
NORTH ML
 
Line 1201 pipeline remediation Window Rock to Navajo
Williams C Station maintenance - Revised Capacity Impact Dth/d
 
                         2,244,804
 
                                 961,356
 
                                961,356
 
                                             -
 
    1,283,448
 
09/29/26
 
09/30/26
 
NM
 
NORTH ML
 
Line 1201 pipeline remediation Window Rock to Navajo
Williams C Station maintenance - Revised Capacity Impact Dth/d
Window Rock 2A inspection
 
                         2,244,804
 
                                 961,356
 
                                961,356
 
                                             -
 
    1,283,448
 
09/15/26
 
09/16/26
 
MOJ
 
MOJTHRU
 
Mojave 1A inspection
 
                             463,000
 
                                 117,000
 
                                117,000
 
                                             -
 
        346,000
 
09/17/26
 
09/18/26
 
MOJ
 
MOJTHRU
 
Mojave 2A inspection
 
                             463,000
 
                                 117,000
 
                                117,000
 
                                             -
 
        346,000
 
09/15/26
 
09/16/26
 
MOJ
 
MOJAVE
 
Mojave 1A inspection
 
                             400,000
 
                                    54,000
 
                                  54,000
 
                                             -
 
        346,000
 
09/17/26
 
09/18/26
 
MOJ
 
MOJAVE
 
Mojave 2A inspection
 
                             400,000
 
                                    54,000
 
                                  54,000
 
                                             -
 
        346,000
 
09/01/26
 
09/03/26
 
XO
 
CAPROCK N
 
Caprock 2A equipment failure repair - FMJ Reduction
Lincoln Station maintenance
 
                             612,700
 
                                 163,132
 
                                  94,752
 
                                  68,380
 
        449,568
 
09/04/26
 
09/14/26
 
XO
 
CAPROCK N
 
Caprock 2A equipment failure repair - FMJ Reduction
 
                             612,700
 
                                    68,380
 
                                              -
 
                                  68,380
 
        544,320
 
09/15/26
 
09/18/26
 
XO
 
CAPROCK N
 
Caprock 2A equipment failure repair - FMJ Reduction
Bluewater Station DOT/ESD Tests
 
                             612,700
 
                                 230,668
 
                                162,288
 
                                  68,380
 
        382,032
 
09/19/26
 
09/28/26
 
XO
 
CAPROCK N
 
Caprock 2A equipment failure repair - FMJ Reduction
 
                             612,700
 
                                    68,380
 
                                              -
 
                                  68,380
 
        544,320
 
09/29/26
 
09/30/26
 
XO
 
CAPROCK N
 
Caprock 2A equipment failure repair - FMJ Reduction
Line 1301 cleaning and smart tools Belen to Laguna
 
                             612,700
 
                                 115,756
 
                                  47,376
 
                                  68,380
 
        496,944
 
09/01/26
 
09/30/26
 
XO
 
LUSK
 
Caprock 2A equipment failure repair - FMJ Reduction
 
                             284,900
 
                                    22,350
 
                                              -
 
                                  22,350
 
        262,550
 
09/01/26
 
09/30/26
 
AN
 
PLAINS N
 
Line No. 1102 anomaly repairs Plains to Dimmit - MLV 16 to MLV 14 - FMJ Reduction
 
                             312,900
 
                                 112,900
 
                                              -
 
                               112,900
 
        200,000
 
09/01/26
 
09/06/26
 
AN
 
AMAR N
 
Amarillo 2A equipment failure repair - FMJ Reduction
Dimmitt 5A maintenance
 
                             292,400
 
                                    33,328
 
                                              -
 
                                  33,328
 
        259,072
 
09/07/26
 
09/30/26
 
AN
 
AMAR N
 
Amarillo 2A equipment failure repair - FMJ Reduction
 
                             292,400
 
                                    33,328
 
                                              -
 
                                  33,328
 
        259,072
 
09/01/26
 
09/06/26
 
AN
 
AMAR S
 
Amarillo 2A equipment failure repair - FMJ Reduction
Dimmitt 5A maintenance
Line No. 1102 anomaly repairs Plains to Dimmit - MLV 16 to MLV 14 - FMJ Reduction
 
                             309,500
 
                                    53,853
 
                                              -
 
                                  53,853
 
        255,647
 
09/07/26
 
09/30/26
 
AN
 
AMAR S
 
Amarillo 2A equipment failure repair - FMJ Reduction
Line No. 1102 anomaly repairs Plains to Dimmit - MLV 16 to MLV 14 - FMJ Reduction
 
                             309,500
 
                                    53,853
 
                                              -
 
                                  53,853
 
        255,647
 
09/22/26
 
09/24/26
 
AN
 
DUMAS E
 
Dumas Station DOT/ESD Tests
 
                             170,000
 
                                    63,290
 
                                  63,290
 
                                             -
 
        106,710
 
09/22/26
 
09/24/26
 
AN
 
DUMAS S
 
Dumas Station DOT/ESD Tests
 
                             310,500
 
                                    37,734
 
                                  37,734
 
                                             -
 
        272,766
 
09/01/26
 
09/30/26
 
PR
 
PLAIN ST
 
Plains 7A repair
Plains 8A repair
Plains 11A repair
Plains 13A repair
Plains 14A repair
Plains 15A repair
Plains Station equipment failure repair - FMJ Reduction
 
                             756,100
 
                                 405,923
 
                                              -
 
                               405,923
 
        350,177
 
09/01/26
 
09/01/26
 
PR
 
377034
 
Texaco Eunice Receipt - (ITEXNEUN) - Eunice 3C inspection - Customer reduced to zero Dth/d during this outage
 
                               76,545
 
                                    76,545
 
                                  76,545
 
                                             -
 
                      -
 
09/01/26
 
09/30/26
 
PR
 
314598
 
Monument A Station equipment failure repair - Warren Monument Receipt (IWARMONU) - Customer to zero Dth/d during Monument A Station mechanical failure repair - FMJ Reduction
 
                               85,739
 
                                    85,739
 
                                              -
 
                                  85,739
 
                      -
 
09/01/26
 
09/14/26
 
PR
 
KEYST ST
 
Keystone 4A repair
Keystone 11A repair
Keystone 1B repair
Keystone 2B repair
 
                             781,000
 
                                 229,021
 
                                229,021
 
                                             -
 
        551,979
 
09/15/26
 
09/18/26
 
PR
 
KEYST ST
 
Keystone 4A repair
Keystone 11A repair
Keystone 1B repair
Keystone 2B repair
Keystone Station DOT/ESD Tests
 
                             781,000
 
                                 558,151
 
                                558,151
 
                                             -
 
        222,849
 
09/19/26
 
09/30/26
 
PR
 
KEYST ST
 
Keystone 4A repair
Keystone 11A repair
Keystone 1B repair
Keystone 2B repair
 
                             781,000
 
                                 229,021
 
                                229,021
 
                                             -
 
        551,979
 
09/01/26
 
09/14/26
 
PR
 
KEYSTAFL
 
Keystone 4A repair
Keystone 11A repair
Keystone 1B repair
Keystone 2B repair
 
                             750,400
 
                                 198,391
 
                                198,391
 
                                             -
 
        552,009
 
09/15/26
 
09/18/26
 
PR
 
KEYSTAFL
 
Keystone Station DOT/ESD Tests
 
                             750,400
 
                                 527,538
 
                                527,538
 
                                             -
 
        222,862
 
09/19/26
 
09/30/26
 
PR
 
KEYSTAFL
 
Keystone 4A repair
Keystone 11A repair
Keystone 1B repair
Keystone 2B repair
 
                             750,400
 
                                 198,391
 
                                198,391
 
                                             -
 
        552,009
 
09/01/26
 
09/30/26
 
PR
 
PUC WAHA
 
Puckett Station equipment failure repair - FMJ Reduction
 
                             130,900
 
                                 130,900
 
                                              -
 
                               130,900
 
                      -
 
09/08/26
 
09/11/26
 
SM
 
PECOS
 
Pecos River Station DOT/ESD Tests
 
                         1,195,600
 
                                 123,328
 
                                123,328
 
                                             -
 
    1,072,272
 
09/08/26
 
09/11/26
 
SM
 
GUADLUP
 
Pecos River Station DOT/ESD Tests
 
                         1,168,300
 
                                 101,079
 
                                101,079
 
                                             -
 
    1,067,221
 
09/15/26
 
09/28/26
 
SM
 
CORN LPW
 
Cornudas 3A maintenance - Cancelled
 
                         1,175,500
 
                                               -
 
                                              -
 
                                             -
 
    1,175,500
 
09/29/26
 
09/30/26
 
SM
 
CORN LPW
 
Cornudas 3A maintenance - Cancelled
Hueco Station DOT/ESD Tests
 
                         1,175,500
 
                                 191,169
 
                                191,169
 
                                             -
 
        984,331
 
09/01/26
 
09/07/26
 
SM
 
LORDSBRG
 
Line 1103 pipeline remediation Lordsburg to San Simon - Delayed
San Simon Station equipment failure repair - FMJ Reduction - Revised Capacity Impact Dth/d
 
                             977,700
 
                                 202,515
 
                                              -
 
                               202,515
 
        775,185
 
09/08/26
 
09/10/26
 
SM
 
LORDSBRG
 
Line 1103 pipeline remediation Lordsburg to San Simon - Rescheduled
San Simon Station equipment failure repair - FMJ Reduction - Revised Capacity Impact Dth/d
 
                             977,700
 
                                 202,515
 
                                              -
 
                               202,515
 
        775,185
 
09/11/26
 
09/13/26
 
SM
 
LORDSBRG
 
Line 1103 pipeline remediation Lordsburg to San Simon - MLV 41.5 to MLV 43
San Simon Station equipment failure repair - FMJ Reduction - Revised Capacity Impact Dth/d
 
                             977,700
 
                                 448,139
 
                                245,624
 
                               202,515
 
        529,561
 
09/14/26
 
09/22/26
 
SM
 
LORDSBRG
 
Line 1103 pipeline remediation Lordsburg to San Simon - MLV 41.5 to MLV 43
Line 1103 pipeline remediation Lordsburg to San Simon - MLV 43 to MLV 44 - No current additional capacity impact
San Simon Station equipment failure repair - FMJ Reduction - Revised Capacity Impact Dth/d
 
                             977,700
 
                                 448,139
 
                                245,624
 
                               202,515
 
        529,561
 
09/23/26
 
09/27/26
 
SM
 
LORDSBRG
 
Line 1103 pipeline remediation Lordsburg to San Simon - MLV 43 to MLV 44 - No current additional capacity impact
San Simon Station equipment failure repair - FMJ Reduction - Revised Capacity Impact Dth/d
 
                             977,700
 
                                 202,515
 
                                              -
 
                               202,515
 
        775,185
 
09/28/26
 
09/29/26
 
SM
 
LORDSBRG
 
Line 1103 pipeline remediation Lordsburg to San Simon - MLV 43 to MLV 44 - No current additional capacity impact
San Simon Station equipment failure repair - FMJ Reduction - Revised Capacity Impact Dth/d
 
                             977,700
 
                                 202,515
 
                                              -
 
                               202,515
 
        775,185
 
09/30/26
 
09/30/26
 
SM
 
LORDSBRG
 
Line 1103 pipeline remediation Lordsburg to San Simon - MLV 43 to MLV 44 - No current additional capacity impact
San Simon Station equipment failure repair - FMJ Reduction - Revised Capacity Impact Dth/d
San Simon Station maintenance - Cancelled
 
                             977,700
 
                                 202,515
 
                                              -
 
                               202,515
 
        775,185
 
09/11/26
 
09/22/26
 
SM
 
314563
 
Tri-State Pyramid Generating Delivery - (IPYRAMID) - Customer reduced to zero Dth/d net capacity during Line 1103 pipeline remediation Lordsburg to San Simon - MLV 41.5 to MLV 43 - Outage coordinated with customer
 
                               50,784
 
                                    50,784
 
                                  50,784
 
                                             -
 
                      -
 
09/24/26
 
09/25/26
 
SM
 
DRAGOON
 
Dragoon Station inspection
 
                             710,200
 
                                 198,027
 
                                198,027
 
                                             -
 
        512,173
 
09/01/26
 
09/30/26
 
PR
 
WA2CORN
 
Gresham Station mechanical failure repair - FMJ Reduction
 
                             734,400
 
                                    67,738
 
                                              -
 
                                  67,738
 
        666,662
 
09/01/26
 
09/03/26
 
SM
 
CORN HPW
 
Lordsburg 1B maintenance
Gresham Station mechanical failure repair - FMJ Reduction
 
                             586,300
 
                                    76,968
 
                                     9,230
 
                                  67,738
 
        509,332
 
09/04/26
 
09/30/26
 
SM
 
CORN HPW
 
Lordsburg 1B maintenance
Gresham Station mechanical failure repair - FMJ Reduction
 
                             586,300
 
                                    76,968
 
                                     9,230
 
                                  67,738
 
        509,332
 
09/01/26
 
09/03/26
 
SM
 
LORDS B
 
Lordsburg 1B maintenance
Gresham Station mechanical failure repair - FMJ Reduction
 
                             580,900
 
                                    75,298
 
                                     7,560
 
                                  67,738
 
        505,602
 
09/04/26
 
09/30/26
 
SM
 
LORDS B
 
Lordsburg 1B maintenance
Gresham Station mechanical failure repair - FMJ Reduction
 
                             580,900
 
                                    75,298
 
                                     7,560
 
                                  67,738
 
        505,602
 
09/01/26
 
09/03/26
 
SM
 
BOWIE
 
Lordsburg 1B maintenance
Gresham Station mechanical failure repair - FMJ Reduction
 
                             579,000
 
                                    75,259
 
                                     7,521
 
                                  67,738
 
        503,741
 
09/04/26
 
09/30/26
 
SM
 
BOWIE
 
Lordsburg 1B maintenance
Gresham Station mechanical failure repair - FMJ Reduction
 
                             579,000
 
                                    75,259
 
                                     7,521
 
                                  67,738
 
        503,741
 
09/01/26
 
09/21/26
 
PR
 
L2000
 
El Paso 4D equipment failure repair - Completed
 
                             608,300
 
                                               -
 
                                              -
 
                                             -
 
        608,300
 
09/22/26
 
09/23/26
 
PR
 
L2000
 
El Paso 4D equipment failure repair - Completed
Cimarron Station inspection
 
                             608,300
 
                                 130,539
 
                                130,539
 
                                             -
 
        477,761
 
09/24/26
 
09/30/26
 
PR
 
L2000
 
El Paso 4D equipment failure repair - Completed
 
                             608,300
 
                                               -
 
                                              -
 
                                             -
 
        608,300
 
09/01/26
 
09/21/26
 
SM
 
CORNL2K
 
El Paso 4D equipment failure repair - Completed
 
                             581,200
 
                                               -
 
                                              -
 
                                             -
 
        581,200
 
09/22/26
 
09/23/26
 
SM
 
CORNL2K
 
El Paso 4D equipment failure repair - Completed
Cimarron Station inspection
 
                             581,200
 
                                 106,195
 
                                106,195
 
                                             -
 
        475,005
 
09/24/26
 
09/30/26
 
SM
 
CORNL2K
 
El Paso 4D equipment failure repair - Completed
 
                             581,200
 
                                               -
 
                                              -
 
                                             -
 
        581,200
 
09/01/26
 
09/30/26
 
SM
 
ELPASO E
 
El Paso 4D equipment failure repair - Completed
 
                             578,900
 
                                               -
 
                                              -
 
                                             -
 
        578,900
 
09/01/26
 
09/21/26
 
SM
 
LORDS C
 
El Paso 4D equipment failure repair - Completed
 
                             574,400
 
                                               -
 
                                              -
 
                                             -
 
        574,400
 
09/22/26
 
09/23/26
 
SM
 
LORDS C
 
El Paso 4D equipment failure repair - Completed
Cimarron Station inspection
 
                             574,400
 
                                 103,774
 
                                103,774
 
                                             -
 
        470,626
 
09/24/26
 
09/30/26
 
SM
 
LORDS C
 
El Paso 4D equipment failure repair - Completed
 
                             574,400
 
                                               -
 
                                              -
 
                                             -
 
        574,400
 
09/01/26
 
09/21/26
 
SM
 
CIMARRON
 
El Paso 4D equipment failure repair - Completed
 
                             572,200
 
                                               -
 
                                              -
 
                                             -
 
        572,200
 
09/22/26
 
09/23/26
 
SM
 
CIMARRON
 
El Paso 4D equipment failure repair - Completed
Cimarron Station inspection
 
                             572,200
 
                                 101,574
 
                                101,574
 
                                             -
 
        470,626
 
09/24/26
 
09/30/26
 
SM
 
CIMARRON
 
El Paso 4D equipment failure repair - Completed
 
                             572,200
 
                                               -
 
                                              -
 
                                             -
 
        572,200
 
In addition to planned outages, this report reflects the repairs and maintenance being performed related to Force Majeure events.
Due to the nature of such events, the dates for the associated repairs and maintenance of those events are assumed to extend until the end of the month.
These repairs and maintenance, however, may extend beyond the end of the month including beyond the current year.
More information on these repairs and maintenance will be posted as a Critical Notice under the Notices section of the Informational Postings tab on the EPNG Electronic Bulletin Board.
EGTS

TL-400 Restrictions Remain in Effect

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Pipeline: EGTS
Notice ID: 1013345
Subject: TL-400 Restrictions Remain in Effect
Notice Type: Notices
Posted: 2026-09-03T13:18:30.124
Effective: 2026-09-03T13:18:30.124
naesbNoticeTypeDescription: Capacity Constraint
subcategory: Critical
tspDefinedNoticeTypeDescription: PPO
Trunkline Gas Company

[Trunkline Gas Company] [Force Majeure] TGC Force Majeure Lifted: Kountze Station Power Outage

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Pipeline: Trunkline Gas Company
Notice ID: 68317
Notice Type: Force Majeure
Subject: TGC Force Majeure Lifted: Kountze Station Power Outage
Posted: 2026-09-03 07:40:00.0
Effective: 2026-09-03 07:40:00.0
End Date: 

Notice ID: 68317
Notice Type: MAJ
Critical: Y
Reqrd Rsp Desc: No Response Required
Posting Date/Time: 2026-09-03 07:40:00.0
Subject: TGC Force Majeure Lifted: Kountze Station Power Outage
Notice Effective Date/Time: 2026-09-03 07:40:00.0
Notice End Date/Time: 2200-01-01 00:00:00.0
Notice Text: 09/03/2026 TGC Force Majeure Lifted: Kountze Station Power Outage Effective immediately, Trunkline has lifted the Notice of Force Majeure for the Kountze Station Power Outage. If you have any questions, please contact your Customer Service or Marketing Representative.
Columbia Gas Transmission (TCO)

CAPACITY POSTING - TIM for September 4, 2026

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name Columbia Gas Transmission, LLC
TSP 054748041
Notice Type Description: Capacity Constraint

Notice Stat Desc: Initiate

Prior Notice: 

Critical: Y

Reqrd Rsp Desc: No Response Required
Post

Notice Effective

Notice End



Response
Post Date: 09/03/26

09/03/26

10/03/26
Subject: Subject: CAPACITY POSTING - TIM for September 4, 2026
Author: Author: Dillon Schoolcraft
Notice Text
COLUMBIA GAS TRANSMISSION, LLC DAILY CAPACITY POSTING

Columbia Gas Transmission LLC (TCO) posts projections of anticipated market area restrictions at least 24 hours prior to the time when nominations are due. These advance forecasts are subject to change based on actual operating conditions. Customers desiring non-firm services should submit timely nominations to determine whether the service is available under current conditions.

============================================================================

============================================================================

FORCE MAJEURE / STORAGE CRITICAL / TRANSPORT CRITICAL / OFO / RATABLE TAKES

No Force Majeure is necessary.

No Critical Day for Storage is necessary. 

No Critical Day for Transport is necessary.

No Operational Flow Order (OFO) is necessary.

Ratable Takes are not required in any Market Areas; however, power customers should request non-ratable takes by submitting a burn profile through TCeConnects.

============================================================================

============================================================================

PIPELINE RECEIPTS, DELIVERIES, INTERNAL CONSTRAINTS, AND DISPLACEMENT AVAILABILITY

For receipts, deliveries, and internal constraints not specifically listed below, please refer to ebb.tceconnects.com/Info Post/Capacity/Operationally Available for information on available capacity at each receipt and delivery point and ebb.tceconnects.com/Info Post/Capacity/Est Op Avail Cap - Internal Constraint for available non-firm capacity at each internal constraint.

Columbia may, from time to time, have displacement capacity available at various receipt/delivery points. Displacement nominations are scheduled based on operational availability up to an approved amount not to exceed the scheduled volumes in the physical direction of flow of the meter. Please contact your Customer Services, Marketing, or O&L Representative for availability at points not listed on this notice.

============================================================================

============================================================================

----------------------------------------------------------------------------

POINT CONSTRAINTS-- Non-Firm Available Capacity:

---------------------------------------------------------------------------- 

633863 - NFG Hartzfelt Mountain - 11,000

640203 - Wagoner Line K - 25,000

640296 - CLINGERMAN - 0

640297 - Range - Sharp - 0

640496 - Range - Day - 0 

640564 - Amwell - 0

642452 - CMG Majorsville - 0

642569 - Mojo - 0

642831 - Range Mills - 0

642838 - Strabane - 0

642854 - Kryptonite - 0

740178 - Fairfield - REX - 75,000

743064 - NEXUS MR06 - 75,000

743365 - Quarry Road - 25,000

736626 - DPL CENTERVILLE - 10,000

737067 - Darby Plant - 75,000

821590 - THOMAS COFFMAN INC YOUNG - 0 

821917 - A&W-Gandee - 0 

823621 - MOUNTAIN STATE-GRANT - 0

824017- STERLING DRG FETTTY - 0 

824766 - TECHNOLOGY DEVELOPMENT - FIELDS - 0 

825005 - CENTRAL PACIFIC GROUP SNYDER - 0 

826130 - STERLING DRG HARPER - 0 

828516 - DORAN-RAINES #1 - 0

833097 - BOSWELLS TAVERN (75-007219) - 0 (Receipts)

833097 - BOSWELLS TAVERN (75-007219) - 100,000

834263 - MCKOWN-JB YOAK LEASE - 0 

835078 - RYAN #702 - 0 

839166 - Patton - 0 

840226 - BenGay MM - 0 

840254 - Vandalia - 0 Total Capacity

842446 - Spencer H Line Sales - 0 

842866 - Green Energy Stonewall - 0

843105 - Transco Chantilly - 50,000

B10 - CAMBRIDGE-9 - 20,000

B15 - UNIONVILLE-35 - 10,000

B17 - HIGHLAND-36 - 20,000

B18 - MILFORD-21 - 0

B9 - BROAD RUN-19 - 0 (Receipts)

B9 - BROAD RUN-19 - 0 (Deliveries)

BYBEE - BYBEE - 0 (Deliveries)

C10 - PLEASANT - 0

C14 - WAYNESBURG - 20,000 

C15 - UNIONTOWN-35 - 0

C16 - DELMONT-36 - 0 (Receipts)

C16 - DELMONT-36 - 0 (Deliveries)

C22 - EAGLE-25 - 0

C23 - PENNSBURG-23 - 0

C41 - TEXAS EASTERN TETCON - 0

C45 - Marietta - 0

C9 - HOOKER-5 - 50,000

E13 - EMPORIA, VA-34 - 0

E17 - MARTINS CREEK - 21 - 0 (Receipts)

E17 - MARTINS CREEK - 21 - 15,000 (Deliveries)

E2 - ROCKVILLE-30 - 0

E3 - DOWNINGTOWN-29 - 0

E9 - YNG WOMANS CK-RENOVO - 0

G8 - EAST LYNN-16 - 0 

MVPWB - MVP Columbia WB - 0 (Receipts)

MVPWB - MVP Columbia WB - 0 (Deliveries)

----------------------------------------------------------------------------

DELIVERY INTERNAL CONSTRAINTS-- Non-Firm Available Capacity:

----------------------------------------------------------------------------

ARTEMAS - Artemas MA25 - 0

BICKBOSW - Bickers MA33 - No Restriction 

CERELANH - Lanham East MA19 - 0 

CERELANW - Lanham West MA19 - 0

CORNHART - Corning East MA20 - 0

CRAWNORT - Crawford North MA8 - 0

CSLOSTRI - Lost River CS MA30 - No Restriction

DELMONSO - Delmont South MA36 - 10,000

DOWNEAST - Downingtown East MA24 - 25,000

GRENCSTL - Greencastle MA25 - No Restriction

HELLHANO - Hellertown MA22 - 0

HIGHLAND - Highland MA38 - 10,000

HOPEWELL - Hopewell MA33 - No Restriction

INDEGLAS - Corning West MA20 - 5,548

KAEAST - KA East MA17 - 0

LANPKA - Lanham PKA MA19 - 0

LEACHSEG - Leach MA19 - No Restriction

LOUDOUN - Loudoun MA28 - No Restriction

LOUISA - Louisa MA33 - No Restriction 

MA1SEG - Pavonia to Toledo - 10,000 

MA3SEG - Lima MA3 - 10,000 

MA6SEG - Dayton MA6 – 20,000

MA7SEG - Sandusky MA7 - 60,000 

NORTKENT - Northern Kentucky OA6 - No Restriction

PTJRWARW - Wagoner East MA21 - No Restriction

RUTLEDGE - Rutledge North MA28 - 50,000

SENECA - Seneca MA30 - No Restriction

----------------------------------------------------------------------------

RECEIPT INTERNAL CONSTRAINTS-- Non-Firm Available Capacity:

----------------------------------------------------------------------------

A03LINEH - Cobb Line H MA18 - No Restriction

A03LOW - Cobb Northwest MA18 - No Restriction

A03NORTH - Cobb Northeast MA40 - No Restriction

A03SOUTH - Cobb South MA18 - No Restriction

ADALSMIF - Smithfield to Adaline MA35 - 0

ALLIAREC - Alliance Receipts MA4 - 20,000

BOLDMAN - Boldman MA16 - 0

CHSTKENO - Line P North MA16 - 25,000 

CLENWAYN - Clendenin to Waynesburg MA35 - 0

COBBA03 - Cobb CS MA18 - No Restriction

CRAWSOUT - Crawford South MA8 - No Restriction

DELMRENO - Delmont MA36 - No Restriction

DOWNWEST - Downingtown West MA24 - 0

EASTON - Easton MA21 - 0

GRANHAML - KA High MA19 - 25,000

HANCOCK - Hancock MA20 - 0

KA1SCBYB - KA1 Station Camp MA13 - 5,500

KAWEST - KA West MA17 - 0

LEBANON - Lebanon MA6 - 50,000 

LONEOAKA - Lone Oak A MA41 - 0

LONEOAKB - Lone Oak B MA41 - 0 

LXPSEG - LXPSEG MA41 - 0

MAYTHUFF - KA Low MA16 - 0 

MXPSEG - MXPSEG MA42 - 0

RUTSOUTH - Rutledge South MA28 - 0 

SHERWODA - Sherwood A MA42 - 0

SHERWODB - Sherwood B MA42 - 100,000 

SMITHFLD - Smithfield MA35 - 0

TANNDELM - Line 1711 MA35 - 0

WALGROVE - Walgrove MA18 - No Restriction

WAYNESNO - Waynesburg North MA35 - 0

 

----------------------------------------------------------------------------

DISPLACEMENT AVAILABILITY-- Non-Firm Available Capacity:

----------------------------------------------------------------------------

843067 - Cornwell - 100,000 

C14 - WAYNESBURG - 30,000

C22 - EAGLE-25 - 25,000

C23 - PENNSBURG-23 - 0

C4 - TETCO LEBANON-6 - 0

E2 - ROCKVILLE-30 - 0

LOUDOUN - LOUDOUN LNG - 0

----------------------------------------------------------------------------

TRANSFER METERS-- Non-Firm Available Capacity:

----------------------------------------------------------------------------

TMBOSWLL - TM Boswells Tavern MA33 - 500,000

TMBRDRUN - TM Broad Run MA19 - 500,000

TMCEREDO - TM Ceredo MA19 - 500,000

TMCHANTY - TM Chantilly MA30 - 500,000

TMEAGLE - TM Eagle MA25 - 500,000

TMLEACH - TM Leach MA19 - 500,000

TMLOSTRI - TM Lost River MA30 - 500,000

TMLOUDN - TM Loudoun MA30 - 500,000

TMLXP - TM LXP MA41 - 500,000

TMMXP - TM MXP MA42 - 500,000

----------------------------------------------------------------------------

LOGICAL METERS-- Non-Firm Available Capacity:

----------------------------------------------------------------------------

MLAPLGRV – Mainline Apple Grove - 500,000

MLCRWFRD - Mainline Crawford - 500,000

MLDRYCRE - Mainline Dry Creek - 500,000

MLEAGLE - Mainline Eagle - 500,000

MLLEACH - Mainline Leach - 500,000

MLLOUDOU - Mainline Loudoun - 500,000

MLLXPMAJ - Mainline LXP Majorsville - 500,000

MLNEWALB - Mainline New Albany - 500,000 

MLPETERS - Mainline Petersburg - 500,000

MLSDRCRK - Mainline Saunders Creek - 500,000

----------------------------------------------------------------------------

DUE PIPE AND DUE SHIPPER AVAILABILITY:

----------------------------------------------------------------------------

OP AREA 01 - Due Pipe - 0, Due Shipper - No Restriction

OP AREA 02 - Due Pipe - 0, Due Shipper - No Restriction

OP AREA 03 - Due Pipe - 0, Due Shipper - No Restriction

OP AREA 04 - Due Pipe - 0, Due Shipper - No Restriction 

OP AREA 05 - Due Pipe - 0, Due Shipper - No Restriction

OP AREA 06 - Due Pipe - 0, Due Shipper - No Restriction

OP AREA 07 - Due Pipe - 0, Due Shipper - No Restriction

OP AREA 08 - Due Pipe - 0, Due Shipper - No Restriction 

OP AREA 10 - Due Pipe - 0, Due Shipper - No Restriction

============================================================================

============================================================================

PAL & IT BUSINESS

Representatives are available daily to discuss PAL transactions with customers who have executed Master PAL Agreements. (Reminder: Each PAL transaction including rate, term, quantity and point(s) must be provided for and approved on the Appendix A under the Master PAL Agreement).Customers who are interested in discounted PAL transactions for next-day or long-term park and/or lend transactions or daily discounted IT paths should contact Diana Roberts at 832-320-5454 (ICE droberts6) or Adam Herndon at 832-689-4510 (ICE adherndon) for more information.

AUTO PAL AVAILABILITY

Effective with EVENING Cycle for each Gas Day, Auto Parks/Loans will be limited to +/-5,000 Dth.Customers are reminded the intent of AutoPAL service is to utilize nominal quantities to resolve pool imbalances that result from upstream or downstream reductions during the cycle.This service should not be used for parking or loaning large quantities.

The following services are eligible for Auto Park/Loan Paybacks and Auto Loan/Park Withdrawals:

IPP

SPP

A01 - Kenova

A02 - Flat Top

A03 - Cobb

A04 - Alexander 

A05 - Delmont 

A06 - McClellandtown

A08 - Crawford

A09 - York 

A10 - Dungannon 

A11 - Binghamton

A12 - Mountaineer Xpress

* Denotes a change from previous posting
Florida Gas Transmission

[Florida Gas Transmission] [Operational Alert] Overage Alert Day 15% Tolerance

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Pipeline: Florida Gas Transmission
Notice ID: 68315
Notice Type: Operational Alert
Subject: Overage Alert Day 15% Tolerance
Posted: Sep 3 2026 6:20 AM
Effective: Sep 3 2026 9:00 AM
End Date: Sep 4 2026 9:00 AM

Notice ID: 68315
Notice Type: Operational Alert
Critical: Y
Notice Status Description: Initiate
Reqrd Rsp Desc: No Response Required
Posting Date/Time: Sep 3 2026 6:20 AM
Subject: Overage Alert Day 15% Tolerance
Notice Effective Date/Time: Sep 3 2026 9:00 AM
Notice End Date/Time: Sep 4 2026 9:00 AM
Notice Text: 90-degree temperatures are forecasted in Florida over the next several days and FGT linepack is below target levels; therefore, for the gas day of September 3, 2026, FGT would like to notify their customers in the FGT Market Area that it is issuing an Overage Alert Day at 15% (Fifteen Percent) tolerance.For the gas day of September 3, 2026, FGT will not interrupt previously scheduled Market Area ITS-1 service below the elapsed prorated scheduled quantity.FGT will continue to monitor hourly and daily takes. Please closely monitor your scheduled point quantities versus actual burn point quantities.
Maritimes & Northeast Canada

09/02/2026- MNCA Operational Advisory

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name: Maritimes & Northeast Pipeline Limited Partnership (Canada)
Subject: MNCA Operational Advisory
Notice Type: Operational Alert
Critical Notice Description: Critical notice
Notice Status Description: Initiate
Notice Effective Date: 09/02/2026
Notice End Date: 12/01/2026
Posting Date: 09/02/2026
Notice Identifier: 182500
Required Response Indicator Description: No response required

Notice Text:
Maritimes Canada (MNCA) is currently experiencing high linepack levels with some shippers having large cumulative imbalances.   In the event shippers continue to grow their cumulative Due Shipper imbalances, MNCA may take necessary steps to keep them in balance, including but not limited to, customer specific OFO's in order to maintain the operational integrity of the pipeline.
Please contact your Operations Account Manager with any questions.
Gulf South Pipeline

Failure to Deliver Confirmed Quantities at Location 464

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Pipeline: Gulf South Pipeline
Notice ID: 5038662
Notice Type: Over-Under Performance
Status: Terminate
Posted: 2026-09-02T14:17:00+00:00
Effective: 2026-09-02T14:20:00+00:00
End: 2026-09-02T15:00:00+00:00
Subject: Failure to Deliver Confirmed Quantities at Location 464

Gulf South Pipeline Notice 5038662
Source Link
All information here is provided as a service and information is not guaranteed to be accurate. PipeRiv is not responsible for any incorrect information.
TSP Name :
Gulf South Pipeline Company, LLC
Category :
Critical
Notice Type Desc :
Over-Under Performance
Notice Stat Desc :
Terminate
Notice ID :
5038662
Prior Notice :
5038656
Reqrd Rsp Desc :
No response required
Subject :
Failure to Deliver Confirmed Quantities at Location 464
TSP :
078444247
Post Date/Time :
09/02/2026 02:17:00 PM
Notice Effective Date/Time :
09/02/2026 02:20:00 PM
Notice End Date/Time :
09/02/2026 03:00:00 PM
Response Date/Time :
Critical :
Notice Text :
Due to Customer’s failure to take confirmed quantities at the locations noted below, Gulf South
Pipeline Company, LLC (“Gulf South”) is notifying customers that it anticipates scheduling
reductions for the remaining nomination cycles for Gas Day 9/2/2026 and until further notice
based upon Projected Daily Quantities* at these locations.
464 Targa Venice
Gulf South continues to monitor this issue and will confirm and schedule nomination cycles
pursuant to the nomination timeline.
“Projected Daily Quantities” is the greater of the Elapsed Prorated Scheduled Quantity or the
Accumulated Measured Quantity plus the Estimated Measured Quantity for the balance of the Gas
Day.  “Accumulated Measured Quantity” is defined as the measured quantities through the location
since the beginning of the Gas Day.  The “Estimated Measured Quantity” is the number of hours
remaining in the Gas Day multiplied by the 30-minute average of the current flow rate divided by
24 hours.
If you have any questions, please contact your customer service representative.
Notice
Page 1 of 1
09/02/2026 2:17:28 PM
Notice
TSP Name :
Gulf South Pipeline Company, LLC
TSP :
078444247
Category :
Critical
Post Date/Time :
09/02/2026 02:17:00 PM
Notice Type Desc :
Over-Under Performance
Notice Effective Date/Time :
09/02/2026 02:20:00 PM
Notice Stat Desc :
Terminate
Notice End Date/Time :
09/02/2026 03:00:00 PM
Notice ID :
5038662
Response Date/Time :
Prior Notice :
5038656
Critical :
Reqrd Rsp Desc :
No response required
Subject :
Failure to Deliver Confirmed Quantities at Location 464
Notice Text :
Due to Customer’s failure to take confirmed quantities at the locations noted below, Gulf South
Pipeline Company, LLC (“Gulf South”) is notifying customers that it anticipates scheduling
reductions for the remaining nomination cycles for Gas Day 9/2/2026 and until further notice
based upon Projected Daily Quantities* at these locations.
464 Targa Venice
Gulf South continues to monitor this issue and will confirm and schedule nomination cycles
pursuant to the nomination timeline.
“Projected Daily Quantities” is the greater of the Elapsed Prorated Scheduled Quantity or the
Accumulated Measured Quantity plus the Estimated Measured Quantity for the balance of the Gas
Day.  “Accumulated Measured Quantity” is defined as the measured quantities through the location
since the beginning of the Gas Day.  The “Estimated Measured Quantity” is the number of hours
remaining in the Gas Day multiplied by the 30-minute average of the current flow rate divided by
24 hours.
If you have any questions, please contact your customer service representative.
09/02/2026 2:17:28 PM
Page 1 of 1
El Paso Natural Gas (EPNG)

[MAINTENANCE] Updated September 2026 Maintenance

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Pipeline: El Paso Natural Gas (EPNG)
Notice Type: MAINTENANCE
Subject: Updated September 2026 Maintenance
Posted: 09/02/2026 1:21:31PM
Effective: 09/02/2026 1:21:31PM
End Date: 09/03/2026 9:00:00AM

TSP/TSP Name:  8001703-EL PASO NATURAL GAS CO. L.L.C. Critical: Y
Notice Type Desc (1):  MAINTENANCE Notice Type Desc (2):  MAINTENANCE
Notice Eff Date/Time:  09/02/2026 1:21:31PM Notice End Date/Time:  09/03/2026 9:00:00am
Post Date/Time:  9/2/2026 1:21:31 PM Notice ID: 629522
Reqrd Rsp:  5 Rsp Date/Time: 
Notice Stat Desc:  SUPERSEDE Prior Notice:  629513
Subject:  Updated September 2026 Maintenance
Notice Text:
EPNG Maintenance Calendar
September 2026
Seg Area
 
Seg Nbr
 
Flow Dir
 
Location
 
Base Capacity (MDth)
 
Tue
1
 
Wed
2
 
Thu
3
 
Fri
4
 
Sat
5
 
Sun
6
 
Mon
7
 
Tue
8
 
Wed
9
 
Thu
10
 
Fri
11
 
Sat
12
 
Sun
13
 
Mon
14
 
Tue
15
 
Wed
16
 
Thu
17
 
Fri
18
 
Sat
19
 
Sun
20
 
Mon
21
 
Tue
22
 
Wed
23
 
Thu
24
 
Fri
25
 
Sat
26
 
Sun
27
 
Mon
28
 
Tue
29
 
Wed
30
Anadarko
 
690
 
F
 
PLAIN ST
 
756
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
 
 
 
 
 
% Seg Avail
 
756
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
Anadarko
 
715
 
B
 
PLAINS N
 
312
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
 
 
 
 
 
% Seg Avail
 
312
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
Anadarko
 
740
 
B
 
AMAR N
 
292
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
 
 
 
 
 
% Seg Avail
 
292
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
Anadarko
 
740
 
F
 
AMAR S
 
309
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
 
 
 
 
 
% Seg Avail
 
309
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
Anadarko
 
760
 
F
 
DUMAS S
 
310
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
37
 
37
 
37
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
% Seg Avail
 
310
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
88%
 
88%
 
88%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
Anadarko
 
780
 
B
 
DUMAS E
 
170
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
63
 
63
 
63
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
% Seg Avail
 
170
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
63%
 
63%
 
63%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
Lincoln Crossover
 
640
 
B
 
CAPROCK N
 
612
 
163
 
163
 
163
 
68
 
68
 
68
 
68
 
68
 
68
 
68
 
68
 
68
 
68
 
68
 
230
 
230
 
230
 
230
 
68
 
68
 
68
 
68
 
68
 
68
 
68
 
68
 
68
 
68
 
115
 
115
 
 
 
 
 
 
% Seg Avail
 
612
 
73%
 
73%
 
73%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
62%
 
62%
 
62%
 
62%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
81%
 
81%
Lincoln Crossover
 
645
 
B
 
LUSK
 
284
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
 
 
 
 
 
% Seg Avail
 
284
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
Line 1903
 
3000
 
F
 
MOJTHRU
 
463
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
117
 
117
 
117
 
117
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
% Seg Avail
 
463
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
75%
 
75%
 
75%
 
75%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
Mojave Seamless
 
3040
 
F
 
MOJAVE
 
400
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
54
 
54
 
54
 
54
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
% Seg Avail
 
400
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
87%
 
87%
 
87%
 
87%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
North Mainline
 
200
 
F
 
NORTH ML
 
2244
 
820
 
983
 
820
 
820
 
649
 
649
 
649
 
649
 
649
 
649
 
649
 
649
 
649
 
649
 
649
 
649
 
649
 
649
 
649
 
649
 
649
 
961
 
961
 
961
 
961
 
961
 
961
 
961
 
961
 
961
 
 
 
 
 
 
% Seg Avail
 
2244
 
63%
 
56%
 
63%
 
63%
 
71%
 
71%
 
71%
 
71%
 
71%
 
71%
 
71%
 
71%
 
71%
 
71%
 
71%
 
71%
 
71%
 
71%
 
71%
 
71%
 
71%
 
57%
 
57%
 
57%
 
57%
 
57%
 
57%
 
57%
 
57%
 
57%
Permian Virtual Segment
 
940
 
F
 
GUADLUP
 
1168
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
101
 
101
 
101
 
101
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Permian Virtual Segment
 
940
 
F
 
KEYST ST
 
781
 
229
 
229
 
229
 
229
 
229
 
229
 
229
 
229
 
229
 
229
 
229
 
229
 
229
 
229
 
558
 
558
 
558
 
558
 
229
 
229
 
229
 
229
 
229
 
229
 
229
 
229
 
229
 
229
 
229
 
229
Permian Virtual Segment
 
940
 
F
 
KEYSTAFL
 
750
 
198
 
198
 
198
 
198
 
198
 
198
 
198
 
198
 
198
 
198
 
198
 
198
 
198
 
198
 
527
 
527
 
527
 
527
 
198
 
198
 
198
 
198
 
198
 
198
 
198
 
198
 
198
 
198
 
198
 
198
Permian Virtual Segment
 
940
 
F
 
L2000
 
608
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
130
 
130
 
0
 
0
 
0
 
0
 
0
 
0
 
0
Permian Virtual Segment
 
940
 
F
 
PECOS
 
1195
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
123
 
123
 
123
 
123
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Permian Virtual Segment
 
940
 
F
 
PUC WAHA
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
Permian Virtual Segment
 
940
 
F
 
WA2CORN
 
734
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Permian Virtual Segment
 
940
 
 
 
314598 (IWARMONU)
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
 
 
 
 
 
% Seg Avail
 
85
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
Permian Virtual Segment
 
940
 
 
 
377034 (ITEXNEUN)
 
76
 
76
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
% Seg Avail
 
76
 
0%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
South Mainline
 
1600
 
F
 
CORN HPW
 
586
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
South Mainline
 
1600
 
F
 
CORN LPW
 
1175
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
191
 
191
South Mainline
 
1600
 
F
 
CORNL2K
 
581
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
106
 
106
 
0
 
0
 
0
 
0
 
0
 
0
 
0
South Mainline
 
1600
 
F
 
CORNTRN
 
150
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
% Seg Avail
 
2492
 
97%
 
97%
 
97%
 
97%
 
97%
 
97%
 
97%
 
97%
 
97%
 
97%
 
97%
 
97%
 
97%
 
97%
 
97%
 
97%
 
97%
 
97%
 
97%
 
97%
 
97%
 
93%
 
93%
 
97%
 
97%
 
97%
 
97%
 
97%
 
89%
 
89%
South Mainline
 
1675
 
F
 
EL PASO
 
1243
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
South Mainline
 
1675
 
F
 
ELPASO C
 
584
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
South Mainline
 
1675
 
F
 
ELPASO E
 
578
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
 
 
 
 
 
% Seg Avail
 
2405
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
South Mainline
 
1760
 
F
 
LORDS B
 
580
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
South Mainline
 
1760
 
F
 
LORDS C
 
574
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
103
 
103
 
0
 
0
 
0
 
0
 
0
 
0
 
0
South Mainline
 
1760
 
F
 
LORDSBRG
 
977
 
202
 
202
 
202
 
202
 
202
 
202
 
202
 
202
 
202
 
202
 
448
 
448
 
448
 
448
 
448
 
448
 
448
 
448
 
448
 
448
 
448
 
448
 
202
 
202
 
202
 
202
 
202
 
202
 
202
 
202
 
 
 
 
 
 
% Seg Avail
 
2131
 
87%
 
87%
 
87%
 
87%
 
87%
 
87%
 
87%
 
87%
 
87%
 
87%
 
75%
 
75%
 
75%
 
75%
 
75%
 
75%
 
75%
 
75%
 
75%
 
75%
 
75%
 
71%
 
82%
 
87%
 
87%
 
87%
 
87%
 
87%
 
87%
 
87%
South Mainline
 
1760
 
 
 
314563 (IPYRAMID)
 
50
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
50
 
50
 
50
 
50
 
50
 
50
 
50
 
50
 
50
 
50
 
50
 
50
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
% Seg Avail
 
50
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
South Mainline
 
1800
 
F
 
BOWIE
 
579
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
South Mainline
 
1800
 
F
 
CIMARRON
 
572
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
101
 
101
 
0
 
0
 
0
 
0
 
0
 
0
 
0
South Mainline
 
1800
 
F
 
DRAGOON
 
710
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
198
 
198
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
% Seg Avail
 
1861
 
96%
 
96%
 
96%
 
96%
 
96%
 
96%
 
96%
 
96%
 
96%
 
96%
 
96%
 
96%
 
96%
 
96%
 
96%
 
96%
 
96%
 
96%
 
96%
 
96%
 
96%
 
91%
 
91%
 
85%
 
85%
 
96%
 
96%
 
96%
 
96%
 
96%
Start Date
 
End Date
 
Region
 
Scheduling Location
 
Maintenance List
 
Base Capacity Dthd
 
Total Reduction Dthd
 
PLM Reduction Dthd
 
FMJ Reduction Dthd
 
Net Dthd
 
Update
09/01/26
 
09/01/26
 
NM
 
NORTH ML
 
Line 1201 pipeline remediation Window Rock to Navajo - Delayed
Williams C Station maintenance - Revised Capacity Impact Dth/d
Seligman C Station equipment failure repair - FMJ Reduction
 
                         2,244,804
 
                                 820,096
 
                                699,391
 
                               120,705
 
    1,424,708
 
09/02/26
 
09/02/26
 
NM
 
NORTH ML
 
Leupp Station maintenance - Revised Capacity Impact Dth/d
Line 1201 pipeline remediation Window Rock to Navajo - Delayed
Williams C Station maintenance - Revised Capacity Impact Dth/d
Seligman C Station equipment failure repair - FMJ Reduction
 
                         2,244,804
 
                                 983,554
 
                                862,849
 
                               120,705
 
    1,261,250
 
09/03/26
 
09/04/26
 
NM
 
NORTH ML
 
Line 1201 pipeline remediation Window Rock to Navajo - Delayed
Williams C Station maintenance - Revised Capacity Impact Dth/d
Seligman C Station equipment failure repair - FMJ Reduction
 
                         2,244,804
 
                                 820,096
 
                                699,391
 
                               120,705
 
    1,424,708
 
09/05/26
 
09/07/26
 
NM
 
NORTH ML
 
Williams C Station maintenance - Revised Capacity Impact Dth/d
 
                         2,244,804
 
                                 649,575
 
                                649,575
 
                                             -
 
    1,595,229
 
09/08/26
 
09/10/26
 
NM
 
NORTH ML
 
Line 1201 pipeline remediation Window Rock to Navajo - Delayed
Leupp 4A inspection
Williams C Station maintenance - Revised Capacity Impact Dth/d
 
                         2,244,804
 
                                 649,575
 
                                649,575
 
                                             -
 
    1,595,229
 
09/11/26
 
09/11/26
 
NM
 
NORTH ML
 
Line 1201 pipeline remediation Window Rock to Navajo - Delayed
Williams C Station maintenance - Revised Capacity Impact Dth/d
 
                         2,244,804
 
                                 649,575
 
                                649,575
 
                                             -
 
    1,595,229
 
09/12/26
 
09/21/26
 
NM
 
NORTH ML
 
Williams C Station maintenance - Revised Capacity Impact Dth/d
 
                         2,244,804
 
                                 649,575
 
                                649,575
 
                                             -
 
    1,595,229
 
09/22/26
 
09/28/26
 
NM
 
NORTH ML
 
Line 1201 pipeline remediation Window Rock to Navajo
Williams C Station maintenance - Revised Capacity Impact Dth/d
 
                         2,244,804
 
                                 961,356
 
                                961,356
 
                                             -
 
    1,283,448
 
09/29/26
 
09/30/26
 
NM
 
NORTH ML
 
Line 1201 pipeline remediation Window Rock to Navajo
Williams C Station maintenance - Revised Capacity Impact Dth/d
Window Rock 2A inspection
 
                         2,244,804
 
                                 961,356
 
                                961,356
 
                                             -
 
    1,283,448
 
09/15/26
 
09/16/26
 
MOJ
 
MOJTHRU
 
Mojave 1A inspection
 
                             463,000
 
                                 117,000
 
                                117,000
 
                                             -
 
        346,000
 
09/17/26
 
09/18/26
 
MOJ
 
MOJTHRU
 
Mojave 2A inspection
 
                             463,000
 
                                 117,000
 
                                117,000
 
                                             -
 
        346,000
 
09/15/26
 
09/16/26
 
MOJ
 
MOJAVE
 
Mojave 1A inspection
 
                             400,000
 
                                    54,000
 
                                  54,000
 
                                             -
 
        346,000
 
09/17/26
 
09/18/26
 
MOJ
 
MOJAVE
 
Mojave 2A inspection
 
                             400,000
 
                                    54,000
 
                                  54,000
 
                                             -
 
        346,000
 
09/01/26
 
09/03/26
 
XO
 
CAPROCK N
 
Caprock 2A equipment failure repair - FMJ Reduction
Lincoln Station maintenance
 
                             612,700
 
                                 163,132
 
                                  94,752
 
                                  68,380
 
        449,568
 
09/04/26
 
09/14/26
 
XO
 
CAPROCK N
 
Caprock 2A equipment failure repair - FMJ Reduction
 
                             612,700
 
                                    68,380
 
                                              -
 
                                  68,380
 
        544,320
 
09/15/26
 
09/18/26
 
XO
 
CAPROCK N
 
Caprock 2A equipment failure repair - FMJ Reduction
Bluewater Station DOT/ESD Tests
 
                             612,700
 
                                 230,668
 
                                162,288
 
                                  68,380
 
        382,032
 
09/19/26
 
09/28/26
 
XO
 
CAPROCK N
 
Caprock 2A equipment failure repair - FMJ Reduction
 
                             612,700
 
                                    68,380
 
                                              -
 
                                  68,380
 
        544,320
 
09/29/26
 
09/30/26
 
XO
 
CAPROCK N
 
Caprock 2A equipment failure repair - FMJ Reduction
Line 1301 cleaning and smart tools Belen to Laguna
 
                             612,700
 
                                 115,756
 
                                  47,376
 
                                  68,380
 
        496,944
 
09/01/26
 
09/30/26
 
XO
 
LUSK
 
Caprock 2A equipment failure repair - FMJ Reduction
 
                             284,900
 
                                    22,350
 
                                              -
 
                                  22,350
 
        262,550
 
09/01/26
 
09/30/26
 
AN
 
PLAINS N
 
Line No. 1102 anomaly repairs Plains to Dimmit - MLV 16 to MLV 14 - FMJ Reduction
 
                             312,900
 
                                 112,900
 
                                              -
 
                               112,900
 
        200,000
 
09/01/26
 
09/06/26
 
AN
 
AMAR N
 
Amarillo 2A equipment failure repair - FMJ Reduction
Dimmitt 5A maintenance
 
                             292,400
 
                                    33,328
 
                                              -
 
                                  33,328
 
        259,072
 
09/07/26
 
09/30/26
 
AN
 
AMAR N
 
Amarillo 2A equipment failure repair - FMJ Reduction
 
                             292,400
 
                                    33,328
 
                                              -
 
                                  33,328
 
        259,072
 
09/01/26
 
09/06/26
 
AN
 
AMAR S
 
Amarillo 2A equipment failure repair - FMJ Reduction
Dimmitt 5A maintenance
Line No. 1102 anomaly repairs Plains to Dimmit - MLV 16 to MLV 14 - FMJ Reduction
 
                             309,500
 
                                    53,853
 
                                              -
 
                                  53,853
 
        255,647
 
09/07/26
 
09/30/26
 
AN
 
AMAR S
 
Amarillo 2A equipment failure repair - FMJ Reduction
Line No. 1102 anomaly repairs Plains to Dimmit - MLV 16 to MLV 14 - FMJ Reduction
 
                             309,500
 
                                    53,853
 
                                              -
 
                                  53,853
 
        255,647
 
09/22/26
 
09/24/26
 
AN
 
DUMAS E
 
Dumas Station DOT/ESD Tests
 
                             170,000
 
                                    63,290
 
                                  63,290
 
                                             -
 
        106,710
 
09/22/26
 
09/24/26
 
AN
 
DUMAS S
 
Dumas Station DOT/ESD Tests
 
                             310,500
 
                                    37,734
 
                                  37,734
 
                                             -
 
        272,766
 
09/01/26
 
09/30/26
 
PR
 
PLAIN ST
 
Plains 7A repair
Plains 8A repair
Plains 11A repair
Plains 13A repair
Plains 14A repair
Plains 15A repair
Plains Station equipment failure repair - FMJ Reduction
 
                             756,100
 
                                 405,923
 
                                              -
 
                               405,923
 
        350,177
 
09/01/26
 
09/01/26
 
PR
 
377034
 
Texaco Eunice Receipt - (ITEXNEUN) - Eunice 3C inspection - Customer reduced to zero Dth/d during this outage
 
                               76,545
 
                                    76,545
 
                                  76,545
 
                                             -
 
                      -
 
09/01/26
 
09/30/26
 
PR
 
314598
 
Monument A Station equipment failure repair - Warren Monument Receipt (IWARMONU) - Customer to zero Dth/d during Monument A Station mechanical failure repair - FMJ Reduction
 
                               85,739
 
                                    85,739
 
                                              -
 
                                  85,739
 
                      -
 
09/01/26
 
09/14/26
 
PR
 
KEYST ST
 
Keystone 4A repair
Keystone 11A repair
Keystone 1B repair
Keystone 2B repair
 
                             781,000
 
                                 229,021
 
                                229,021
 
                                             -
 
        551,979
 
09/15/26
 
09/18/26
 
PR
 
KEYST ST
 
Keystone 4A repair
Keystone 11A repair
Keystone 1B repair
Keystone 2B repair
Keystone Station DOT/ESD Tests
 
                             781,000
 
                                 558,151
 
                                558,151
 
                                             -
 
        222,849
 
09/19/26
 
09/30/26
 
PR
 
KEYST ST
 
Keystone 4A repair
Keystone 11A repair
Keystone 1B repair
Keystone 2B repair
 
                             781,000
 
                                 229,021
 
                                229,021
 
                                             -
 
        551,979
 
09/01/26
 
09/14/26
 
PR
 
KEYSTAFL
 
Keystone 4A repair
Keystone 11A repair
Keystone 1B repair
Keystone 2B repair
 
                             750,400
 
                                 198,391
 
                                198,391
 
                                             -
 
        552,009
 
09/15/26
 
09/18/26
 
PR
 
KEYSTAFL
 
Keystone Station DOT/ESD Tests
 
                             750,400
 
                                 527,538
 
                                527,538
 
                                             -
 
        222,862
 
09/19/26
 
09/30/26
 
PR
 
KEYSTAFL
 
Keystone 4A repair
Keystone 11A repair
Keystone 1B repair
Keystone 2B repair
 
                             750,400
 
                                 198,391
 
                                198,391
 
                                             -
 
        552,009
 
09/01/26
 
09/30/26
 
PR
 
PUC WAHA
 
Puckett Station equipment failure repair - FMJ Reduction
 
                             130,900
 
                                 130,900
 
                                              -
 
                               130,900
 
                      -
 
09/08/26
 
09/11/26
 
SM
 
PECOS
 
Pecos River Station DOT/ESD Tests
 
                         1,195,600
 
                                 123,328
 
                                123,328
 
                                             -
 
    1,072,272
 
09/08/26
 
09/11/26
 
SM
 
GUADLUP
 
Pecos River Station DOT/ESD Tests
 
                         1,168,300
 
                                 101,079
 
                                101,079
 
                                             -
 
    1,067,221
 
09/15/26
 
09/28/26
 
SM
 
CORN LPW
 
Cornudas 3A maintenance - Cancelled
 
                         1,175,500
 
                                               -
 
                                              -
 
                                             -
 
    1,175,500
 
09/29/26
 
09/30/26
 
SM
 
CORN LPW
 
Cornudas 3A maintenance - Cancelled
Hueco Station DOT/ESD Tests
 
                         1,175,500
 
                                 191,169
 
                                191,169
 
                                             -
 
        984,331
 
09/01/26
 
09/07/26
 
SM
 
LORDSBRG
 
Line 1103 pipeline remediation Lordsburg to San Simon - Delayed
San Simon Station equipment failure repair - FMJ Reduction - Revised Capacity Impact Dth/d
 
                             977,700
 
                                 202,515
 
                                              -
 
                               202,515
 
        775,185
 
09/08/26
 
09/10/26
 
SM
 
LORDSBRG
 
Line 1103 pipeline remediation Lordsburg to San Simon - Rescheduled
San Simon Station equipment failure repair - FMJ Reduction - Revised Capacity Impact Dth/d
 
                             977,700
 
                                 202,515
 
                                              -
 
                               202,515
 
        775,185
 
Update
09/11/26
 
09/13/26
 
SM
 
LORDSBRG
 
Line 1103 pipeline remediation Lordsburg to San Simon - MLV 41.5 to MLV 43
San Simon Station equipment failure repair - FMJ Reduction - Revised Capacity Impact Dth/d
 
                             977,700
 
                                 448,139
 
                                245,624
 
                               202,515
 
        529,561
 
Update
09/14/26
 
09/22/26
 
SM
 
LORDSBRG
 
Line 1103 pipeline remediation Lordsburg to San Simon - MLV 41.5 to MLV 43
Line 1103 pipeline remediation Lordsburg to San Simon - MLV 43 to MLV 44 - No current additional capacity impact
San Simon Station equipment failure repair - FMJ Reduction - Revised Capacity Impact Dth/d
 
                             977,700
 
                                 448,139
 
                                245,624
 
                               202,515
 
        529,561
 
Update
09/23/26
 
09/27/26
 
SM
 
LORDSBRG
 
Line 1103 pipeline remediation Lordsburg to San Simon - MLV 43 to MLV 44 - No current additional capacity impact
San Simon Station equipment failure repair - FMJ Reduction - Revised Capacity Impact Dth/d
 
                             977,700
 
                                 202,515
 
                                              -
 
                               202,515
 
        775,185
 
Update
09/28/26
 
09/29/26
 
SM
 
LORDSBRG
 
Line 1103 pipeline remediation Lordsburg to San Simon - MLV 43 to MLV 44 - No current additional capacity impact
San Simon Station equipment failure repair - FMJ Reduction - Revised Capacity Impact Dth/d
 
                             977,700
 
                                 202,515
 
                                              -
 
                               202,515
 
        775,185
 
Update
09/30/26
 
09/30/26
 
SM
 
LORDSBRG
 
Line 1103 pipeline remediation Lordsburg to San Simon - MLV 43 to MLV 44 - No current additional capacity impact
San Simon Station equipment failure repair - FMJ Reduction - Revised Capacity Impact Dth/d
San Simon Station maintenance - Cancelled
 
                             977,700
 
                                 202,515
 
                                              -
 
                               202,515
 
        775,185
 
Update
09/11/26
 
09/22/26
 
SM
 
314563
 
Tri-State Pyramid Generating Delivery - (IPYRAMID) - Customer reduced to zero Dth/d net capacity during Line 1103 pipeline remediation Lordsburg to San Simon - MLV 41.5 to MLV 43 - Outage coordinated with customer
 
                               50,784
 
                                    50,784
 
                                  50,784
 
                                             -
 
                      -
 
Update
09/24/26
 
09/25/26
 
SM
 
DRAGOON
 
Dragoon Station inspection
 
                             710,200
 
                                 198,027
 
                                198,027
 
                                             -
 
        512,173
 
09/01/26
 
09/30/26
 
PR
 
WA2CORN
 
Gresham Station mechanical failure repair - FMJ Reduction
 
                             734,400
 
                                    67,738
 
                                              -
 
                                  67,738
 
        666,662
 
09/01/26
 
09/03/26
 
SM
 
CORN HPW
 
Lordsburg 1B maintenance
Gresham Station mechanical failure repair - FMJ Reduction
 
                             586,300
 
                                    76,968
 
                                     9,230
 
                                  67,738
 
        509,332
 
09/04/26
 
09/30/26
 
SM
 
CORN HPW
 
Lordsburg 1B maintenance
Gresham Station mechanical failure repair - FMJ Reduction
 
                             586,300
 
                                    76,968
 
                                     9,230
 
                                  67,738
 
        509,332
 
09/01/26
 
09/03/26
 
SM
 
LORDS B
 
Lordsburg 1B maintenance
Gresham Station mechanical failure repair - FMJ Reduction
 
                             580,900
 
                                    75,298
 
                                     7,560
 
                                  67,738
 
        505,602
 
09/04/26
 
09/30/26
 
SM
 
LORDS B
 
Lordsburg 1B maintenance
Gresham Station mechanical failure repair - FMJ Reduction
 
                             580,900
 
                                    75,298
 
                                     7,560
 
                                  67,738
 
        505,602
 
09/01/26
 
09/03/26
 
SM
 
BOWIE
 
Lordsburg 1B maintenance
Gresham Station mechanical failure repair - FMJ Reduction
 
                             579,000
 
                                    75,259
 
                                     7,521
 
                                  67,738
 
        503,741
 
09/04/26
 
09/30/26
 
SM
 
BOWIE
 
Lordsburg 1B maintenance
Gresham Station mechanical failure repair - FMJ Reduction
 
                             579,000
 
                                    75,259
 
                                     7,521
 
                                  67,738
 
        503,741
 
09/01/26
 
09/21/26
 
PR
 
L2000
 
El Paso 4D equipment failure repair - Completed
 
                             608,300
 
                                               -
 
                                              -
 
                                             -
 
        608,300
 
09/22/26
 
09/23/26
 
PR
 
L2000
 
El Paso 4D equipment failure repair - Completed
Cimarron Station inspection
 
                             608,300
 
                                 130,539
 
                                130,539
 
                                             -
 
        477,761
 
09/24/26
 
09/30/26
 
PR
 
L2000
 
El Paso 4D equipment failure repair - Completed
 
                             608,300
 
                                               -
 
                                              -
 
                                             -
 
        608,300
 
09/01/26
 
09/21/26
 
SM
 
CORNL2K
 
El Paso 4D equipment failure repair - Completed
 
                             581,200
 
                                               -
 
                                              -
 
                                             -
 
        581,200
 
09/22/26
 
09/23/26
 
SM
 
CORNL2K
 
El Paso 4D equipment failure repair - Completed
Cimarron Station inspection
 
                             581,200
 
                                 106,195
 
                                106,195
 
                                             -
 
        475,005
 
09/24/26
 
09/30/26
 
SM
 
CORNL2K
 
El Paso 4D equipment failure repair - Completed
 
                             581,200
 
                                               -
 
                                              -
 
                                             -
 
        581,200
 
09/01/26
 
09/30/26
 
SM
 
ELPASO E
 
El Paso 4D equipment failure repair - Completed
 
                             578,900
 
                                               -
 
                                              -
 
                                             -
 
        578,900
 
09/01/26
 
09/21/26
 
SM
 
LORDS C
 
El Paso 4D equipment failure repair - Completed
 
                             574,400
 
                                               -
 
                                              -
 
                                             -
 
        574,400
 
09/22/26
 
09/23/26
 
SM
 
LORDS C
 
El Paso 4D equipment failure repair - Completed
Cimarron Station inspection
 
                             574,400
 
                                 103,774
 
                                103,774
 
                                             -
 
        470,626
 
09/24/26
 
09/30/26
 
SM
 
LORDS C
 
El Paso 4D equipment failure repair - Completed
 
                             574,400
 
                                               -
 
                                              -
 
                                             -
 
        574,400
 
09/01/26
 
09/21/26
 
SM
 
CIMARRON
 
El Paso 4D equipment failure repair - Completed
 
                             572,200
 
                                               -
 
                                              -
 
                                             -
 
        572,200
 
09/22/26
 
09/23/26
 
SM
 
CIMARRON
 
El Paso 4D equipment failure repair - Completed
Cimarron Station inspection
 
                             572,200
 
                                 101,574
 
                                101,574
 
                                             -
 
        470,626
 
09/24/26
 
09/30/26
 
SM
 
CIMARRON
 
El Paso 4D equipment failure repair - Completed
 
                             572,200
 
                                               -
 
                                              -
 
                                             -
 
        572,200
 
In addition to planned outages, this report reflects the repairs and maintenance being performed related to Force Majeure events.
Due to the nature of such events, the dates for the associated repairs and maintenance of those events are assumed to extend until the end of the month.
These repairs and maintenance, however, may extend beyond the end of the month including beyond the current year.
More information on these repairs and maintenance will be posted as a Critical Notice under the Notices section of the Informational Postings tab on the EPNG Electronic Bulletin Board.
Iroquois Gas Transmission

Capacity Constraint

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Capacity Constraint Effective Timely Cycle, Gas Day September 3, 2026, nominations are sealed from all increases through the following locations: - Brookfield Interconnect with Algonquin Gas Transmission. In addition, the following capacity has been reduced: - Brookfield Interconnect – Park, Interruptible and Secondary receipt nominations are reduced by 100%. If you have any further questions, please contact the Iroquois Scheduling or Gas Control Group. End date 09/04/2026 09:00 AM CCT
Tallgrass Energy

[Ruby Pipeline] [MAINTENANCE] RUBY MAINTENANCE SCHEDULE FOR SEPTEMBER 2026 - UPDATE #1

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Pipeline: Ruby Pipeline
Notice ID: 14060
Notice Type: Critical notice
Sub-Type: MAINTENANCE
Subject: RUBY MAINTENANCE SCHEDULE FOR SEPTEMBER 2026 - UPDATE #1
Posted: 9/2/2026 11:58:15 AM
Effective: 9/2/2026 11:58:15 AM
End Date: 12/31/9000

RUBY MAINTENANCE SCHEDULE FOR SEPTEMBER 2026 – UPDATE #1
Ruby is updating the Segment 40 ILI Tool Run to a 700 MDth/d capacity through Segment 40.
All other items remain the same as posted under notice ID 14032
SEGMENT 40 ILI TOOL RUN
On Gas Day Wednesday, September 9, 2026, Ruby will be conducting an ILI Tool Run in Segment 40.
Operating capacity will be limited to 700 MDth/d through Segment 40.
At this capacity level, primary and secondary firm quantities, as well as ITS/AOR are at risk of not being
scheduled.
SEGMENT 10 ILI TOOL RUN
On Gas Day Tuesday, September 29, 2026, Ruby will be conducting an ILI Tool Run in Segment 10. Ruby
is not expecting this outage to impact shippers; however, Ruby will provide as much notice as possible
with individual postings on the EBB in the event capacity will be impacted.
SEGMENT 20 ILI TOOL RUN
On Gas Day Wednesday, September 30, 2026, Ruby will be conducting an ILI Tool Run in Segment 20.
Ruby is not expecting this outage to impact shippers; however, Ruby will provide as much notice as
possible with individual postings on the EBB in the event capacity will be impacted.
In the event Ruby cannot schedule the firm service nominations from Primary Receipt to Primary
Delivery on a Day during the scheduled maintenance outlined above, Reservation Charge Credit
Quantities are calculated pursuant to Section 16.
To the extent there is a limitation to scheduling or curtailment of firm service nominations, available
pipeline capacity will be scheduled first to firm transportation nominations from Primary Points and
along Primary Paths and remaining capacity will be scheduled pro rata based on MDQ and consistent
with Section 6.5, of the General Terms and Conditions of the Ruby FERC Gas Tariff.
If you have any questions, please contact your Account Director or Scheduling Representative at 303-
763-2906.
Tallgrass Energy

[Tallgrass Interstate Gas Transmission (TIGT)] [MAINTENANCE] TIGT MAINTENANCE SCHEDULE FOR SEPTEMBER 2026 - UPDATE #1

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Pipeline: Tallgrass Interstate Gas Transmission (TIGT)
Notice ID: 14058
Notice Type: Critical notice
Sub-Type: MAINTENANCE
Subject: TIGT MAINTENANCE SCHEDULE FOR SEPTEMBER 2026 - UPDATE #1
Posted: 9/2/2026 11:05:20 AM
Effective: 9/2/2026 11:05:20 AM
End Date: 12/31/9000

TIGT MAINTENANCE SCHEDULE FOR SEPTEMBER 2026 – UPDATE #1
TIGT is rescheduling the Segment 410 Maintenance to a later date.
All other items remain the same as posted under notice ID 14030
SEGMENT 125 MAINTENANCE (SEG 125)
On Gas Day Tuesday, September 8, 2026, through Gas Day Thursday, September 17, 2026, TIGT
will be performing maintenance on Segment 125. TIGT is not expecting this outage to impact
shippers, however, TIGT will provide as much notice as possible with individual postings on the
EBB in the event capacity will be impacted.
SEGMENT 210 MAINTENANCE (SEG 210)
On Gas Day Monday, September 21, 2026, through Gas Day Friday, October 9, 2026, TIGT will
be performing maintenance along Segment 210 (Seg 210). The following restrictions will be in
place:
• Operating capacity will be limited to 101.6 MDth/d through Segment 210.
• No displacement nominations will be scheduled at East Zone receipt locations
• Shipper nominated withdrawals for Interruptible Storage Service (“ISS”), as well as
shipper nominated authorized overrun (AOR) for FSS, NNS (including SCS), and CMC-2
services will not be scheduled.
• In addition, additional supply in the East Zone will help prevent additional reductions
through segment 210.
At this capacity level, primary and secondary firm quantities, as well as ITS/AOR are at risk of not
being scheduled.
ATWOOD TO ST FRANCIS LATERAL MAINTENANCE (SEG 170)
On Gas Day Tuesday, September 29, 2026, through Gas Day Wednesday, September 30, 2026,
TIGT will be performing maintenance along the Atwood to St Francis Lateral. Certain distribution
farm taps and/or project lines may be impacted.
At this capacity level, primary and secondary firm quantities, as well as ITS/AOR are at risk of not
being scheduled.
In the event TIGT cannot schedule the firm service nominations from Primary Receipt to
Primary Delivery on a Day, Reservation Charge Credit Quantities are calculated pursuant to
Section 9.14 D 2 a) and are based upon a firm shipper’s average daily usage at Primary Points
during the 7 complete Gas Days prior to the day TIGT posts the Monthly Maintenance
Schedule, except where the 7-Day period is limited by pre-existing firm service curtailments
pursuant to Section 9.14 D 2 d).

To the extent there is a limitation to scheduling or curtailment of firm service nominations,
available pipeline capacity will be scheduled first to firm transportation nominations from
Primary Points and along Primary Paths and remaining capacity will be scheduled pro rata
based on nominations and consistent with Section 4.2 of the General Terms and Conditions of
the TIGT FERC Gas Tariff.
For questions, please contact your Account Director or Scheduling Representative at 303-763-
2906.
Gulf South Pipeline

Failure to Deliver Confirmed Quantities at Location 464

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Pipeline: Gulf South Pipeline
Notice ID: 5038656
Notice Type: Over-Under Performance
Status: Initiate
Posted: 2026-09-02T10:29:00+00:00
Effective: 2026-09-02T10:30:00+00:00
End: 2026-09-03T09:00:00+00:00
Subject: Failure to Deliver Confirmed Quantities at Location  464

Gulf South Pipeline Notice 5038656
Source Link
All information here is provided as a service and information is not guaranteed to be accurate. PipeRiv is not responsible for any incorrect information.
TSP Name :
Gulf South Pipeline Company, LLC
Category :
Critical
Notice Type Desc :
Over-Under Performance
Notice Stat Desc :
Initiate
Notice ID :
5038656
Prior Notice :
Reqrd Rsp Desc :
No response required
Subject :
Failure to Deliver Confirmed Quantities at Location 464
TSP :
078444247
Post Date/Time :
09/02/2026 10:29:00 AM
Notice Effective Date/Time :
09/02/2026 10:30:00 AM
Notice End Date/Time :
09/03/2026 09:00:00 AM
Response Date/Time :
Critical :
Notice Text :
Due to Customer’s failure to take confirmed quantities at the locations noted below, Gulf South
Pipeline Company, LLC (“Gulf South”) is notifying customers that it anticipates scheduling
reductions for the remaining nomination cycles for Gas Day 9/2/2026 and until further notice
based upon Projected Daily Quantities* at these locations.
464 Targa Venice
Gulf South continues to monitor this issue and will confirm and schedule nomination cycles
pursuant to the nomination timeline.
“Projected Daily Quantities” is the greater of the Elapsed Prorated Scheduled Quantity or the
Accumulated Measured Quantity plus the Estimated Measured Quantity for the balance of the Gas
Day.  “Accumulated Measured Quantity” is defined as the measured quantities through the location
since the beginning of the Gas Day.  The “Estimated Measured Quantity” is the number of hours
remaining in the Gas Day multiplied by the 30-minute average of the current flow rate divided by
24 hours.
If you have any questions, please contact your customer service representative.
Notice
Page 1 of 1
09/02/2026 10:29:33 AM
Notice
TSP Name :
Gulf South Pipeline Company, LLC
TSP :
078444247
Category :
Critical
Post Date/Time :
09/02/2026 10:29:00 AM
Notice Type Desc :
Over-Under Performance
Notice Effective Date/Time :
09/02/2026 10:30:00 AM
Notice Stat Desc :
Initiate
Notice End Date/Time :
09/03/2026 09:00:00 AM
Notice ID :
5038656
Response Date/Time :
Prior Notice :
Critical :
Reqrd Rsp Desc :
No response required
Subject :
Failure to Deliver Confirmed Quantities at Location 464
Notice Text :
Due to Customer’s failure to take confirmed quantities at the locations noted below, Gulf South
Pipeline Company, LLC (“Gulf South”) is notifying customers that it anticipates scheduling
reductions for the remaining nomination cycles for Gas Day 9/2/2026 and until further notice
based upon Projected Daily Quantities* at these locations.
464 Targa Venice
Gulf South continues to monitor this issue and will confirm and schedule nomination cycles
pursuant to the nomination timeline.
“Projected Daily Quantities” is the greater of the Elapsed Prorated Scheduled Quantity or the
Accumulated Measured Quantity plus the Estimated Measured Quantity for the balance of the Gas
Day.  “Accumulated Measured Quantity” is defined as the measured quantities through the location
since the beginning of the Gas Day.  The “Estimated Measured Quantity” is the number of hours
remaining in the Gas Day multiplied by the 30-minute average of the current flow rate divided by
24 hours.
If you have any questions, please contact your customer service representative.
09/02/2026 10:29:33 AM
Page 1 of 1
Columbia Gas Transmission (TCO)

CAPACITY POSTING - TIM for September 3, 2026

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name Columbia Gas Transmission, LLC
TSP 054748041
Notice Type Description: Capacity Constraint

Notice Stat Desc: Initiate

Prior Notice: 

Critical: Y

Reqrd Rsp Desc: No Response Required
Post

Notice Effective

Notice End



Response
Post Date: 09/02/26

09/02/26

10/02/26
Subject: Subject: CAPACITY POSTING - TIM for September 3, 2026
Author: Author: Dillon Schoolcraft
Notice Text
COLUMBIA GAS TRANSMISSION, LLC DAILY CAPACITY POSTING

Columbia Gas Transmission LLC (TCO) posts projections of anticipated market area restrictions at least 24 hours prior to the time when nominations are due. These advance forecasts are subject to change based on actual operating conditions. Customers desiring non-firm services should submit timely nominations to determine whether the service is available under current conditions.

============================================================================

============================================================================

FORCE MAJEURE / STORAGE CRITICAL / TRANSPORT CRITICAL / OFO / RATABLE TAKES

No Force Majeure is necessary.

No Critical Day for Storage is necessary. 

No Critical Day for Transport is necessary.

No Operational Flow Order (OFO) is necessary.

Ratable Takes are not required in any Market Areas; however, power customers should request non-ratable takes by submitting a burn profile through TCeConnects.

============================================================================

============================================================================

PIPELINE RECEIPTS, DELIVERIES, INTERNAL CONSTRAINTS, AND DISPLACEMENT AVAILABILITY

For receipts, deliveries, and internal constraints not specifically listed below, please refer to ebb.tceconnects.com/Info Post/Capacity/Operationally Available for information on available capacity at each receipt and delivery point and ebb.tceconnects.com/Info Post/Capacity/Est Op Avail Cap - Internal Constraint for available non-firm capacity at each internal constraint.

Columbia may, from time to time, have displacement capacity available at various receipt/delivery points. Displacement nominations are scheduled based on operational availability up to an approved amount not to exceed the scheduled volumes in the physical direction of flow of the meter. Please contact your Customer Services, Marketing, or O&L Representative for availability at points not listed on this notice.

============================================================================

============================================================================

----------------------------------------------------------------------------

POINT CONSTRAINTS-- Non-Firm Available Capacity:

---------------------------------------------------------------------------- 

633863 - NFG Hartzfelt Mountain - 11,000

640203 - Wagoner Line K - 25,000

640296 - CLINGERMAN - 0

640297 - Range - Sharp - 0

640496 - Range - Day - 0 

640564 - Amwell - 0

642452 - CMG Majorsville - 0

642569 - Mojo - 0

642831 - Range Mills - 0

642838 - Strabane - 0

642854 - Kryptonite - 0

740178 - Fairfield - REX - 75,000

743064 - NEXUS MR06 - 75,000

743365 - Quarry Road - 25,000

736626 - DPL CENTERVILLE - 10,000

737067 - Darby Plant - 75,000

821590 - THOMAS COFFMAN INC YOUNG - 0 

821917 - A&W-Gandee - 0 

823621 - MOUNTAIN STATE-GRANT - 0

824017- STERLING DRG FETTTY - 0 

824766 - TECHNOLOGY DEVELOPMENT - FIELDS - 0 

825005 - CENTRAL PACIFIC GROUP SNYDER - 0 

826130 - STERLING DRG HARPER - 0 

828516 - DORAN-RAINES #1 - 0

833097 - BOSWELLS TAVERN (75-007219) - 0 (Receipts)

833097 - BOSWELLS TAVERN (75-007219) - 100,000

834263 - MCKOWN-JB YOAK LEASE - 0 

835078 - RYAN #702 - 0 

839166 - Patton - 0 

840226 - BenGay MM - 0 

840254 - Vandalia - 0 Total Capacity

842446 - Spencer H Line Sales - 0 

842866 - Green Energy Stonewall - 0

843105 - Transco Chantilly - 50,000

B10 - CAMBRIDGE-9 - 20,000

B15 - UNIONVILLE-35 - 10,000

B17 - HIGHLAND-36 - 20,000

B18 - MILFORD-21 - 0

B9 - BROAD RUN-19 - 0 (Receipts)

B9 - BROAD RUN-19 - 0 (Deliveries)

BYBEE - BYBEE - 0 (Deliveries)

C10 - PLEASANT - 0

C14 - WAYNESBURG - 20,000 

C15 - UNIONTOWN-35 - 0

C16 - DELMONT-36 - 0 (Receipts)

C16 - DELMONT-36 - 0 (Deliveries)

C22 - EAGLE-25 - 0

C23 - PENNSBURG-23 - 0

C41 - TEXAS EASTERN TETCON - 0

C45 - Marietta - 0

C9 - HOOKER-5 - 50,000

E13 - EMPORIA, VA-34 - 0

E17 - MARTINS CREEK - 21 - 0 (Receipts)

E17 - MARTINS CREEK - 21 - 15,000 (Deliveries)

E2 - ROCKVILLE-30 - 0

E3 - DOWNINGTOWN-29 - 0

E9 - YNG WOMANS CK-RENOVO - 0

G8 - EAST LYNN-16 - 0 

MVPWB - MVP Columbia WB - 0 (Receipts)

MVPWB - MVP Columbia WB - 0 (Deliveries)

----------------------------------------------------------------------------

DELIVERY INTERNAL CONSTRAINTS-- Non-Firm Available Capacity:

----------------------------------------------------------------------------

ARTEMAS - Artemas MA25 - 0

BICKBOSW - Bickers MA33 - No Restriction 

CERELANH - Lanham East MA19 - 0 

CERELANW - Lanham West MA19 - 0

CORNHART - Corning East MA20 - 0

CRAWNORT - Crawford North MA8 - 0

CSLOSTRI - Lost River CS MA30 - No Restriction

DELMONSO - Delmont South MA36 - 10,000

DOWNEAST - Downingtown East MA24 - 25,000

GRENCSTL - Greencastle MA25 - No Restriction

HELLHANO - Hellertown MA22 - 0

HIGHLAND - Highland MA38 - 10,000

HOPEWELL - Hopewell MA33 - No Restriction

INDEGLAS - Corning West MA20 - 5,548

KAEAST - KA East MA17 - 0

LANPKA - Lanham PKA MA19 - 0

LEACHSEG - Leach MA19 - No Restriction

LOUDOUN - Loudoun MA28 - No Restriction

LOUISA - Louisa MA33 - No Restriction 

MA1SEG - Pavonia to Toledo - 10,000 

MA3SEG - Lima MA3 - 10,000 

MA6SEG - Dayton MA6 – 20,000

MA7SEG - Sandusky MA7 - 60,000 

NORTKENT - Northern Kentucky OA6 - No Restriction

PTJRWARW - Wagoner East MA21 - No Restriction

RUTLEDGE - Rutledge North MA28 - 50,000

SENECA - Seneca MA30 - No Restriction

----------------------------------------------------------------------------

RECEIPT INTERNAL CONSTRAINTS-- Non-Firm Available Capacity:

----------------------------------------------------------------------------

A03LINEH - Cobb Line H MA18 - No Restriction

A03LOW - Cobb Northwest MA18 - No Restriction

A03NORTH - Cobb Northeast MA40 - No Restriction

A03SOUTH - Cobb South MA18 - No Restriction

ADALSMIF - Smithfield to Adaline MA35 - 0

ALLIAREC - Alliance Receipts MA4 - 20,000

BOLDMAN - Boldman MA16 - 0

CHSTKENO - Line P North MA16 - 25,000 

CLENWAYN - Clendenin to Waynesburg MA35 - 0

COBBA03 - Cobb CS MA18 - No Restriction

CRAWSOUT - Crawford South MA8 - No Restriction

DELMRENO - Delmont MA36 - No Restriction

DOWNWEST - Downingtown West MA24 - 0

EASTON - Easton MA21 - 0

GRANHAML - KA High MA19 - 25,000

HANCOCK - Hancock MA20 - 0

KA1SCBYB - KA1 Station Camp MA13 - 5,500

KAWEST - KA West MA17 - 0

LEBANON - Lebanon MA6 - 50,000 

LONEOAKA - Lone Oak A MA41 - 0

LONEOAKB - Lone Oak B MA41 - 0 

LXPSEG - LXPSEG MA41 - 0

MAYTHUFF - KA Low MA16 - 0 

MXPSEG - MXPSEG MA42 - 0

RUTSOUTH - Rutledge South MA28 - 0 

SHERWODA - Sherwood A MA42 - 0

SHERWODB - Sherwood B MA42 - 100,000 

SMITHFLD - Smithfield MA35 - 0

TANNDELM - Line 1711 MA35 - 0

WALGROVE - Walgrove MA18 - No Restriction

WAYNESNO - Waynesburg North MA35 - 0

 

----------------------------------------------------------------------------

DISPLACEMENT AVAILABILITY-- Non-Firm Available Capacity:

----------------------------------------------------------------------------

843067 - Cornwell - 100,000 

C14 - WAYNESBURG - 30,000

C22 - EAGLE-25 - 25,000

C23 - PENNSBURG-23 - 0

C4 - TETCO LEBANON-6 - 0

E2 - ROCKVILLE-30 - 0

LOUDOUN - LOUDOUN LNG - 0

----------------------------------------------------------------------------

TRANSFER METERS-- Non-Firm Available Capacity:

----------------------------------------------------------------------------

TMBOSWLL - TM Boswells Tavern MA33 - 500,000

TMBRDRUN - TM Broad Run MA19 - 500,000

TMCEREDO - TM Ceredo MA19 - 500,000

TMCHANTY - TM Chantilly MA30 - 500,000

TMEAGLE - TM Eagle MA25 - 500,000

TMLEACH - TM Leach MA19 - 500,000

TMLOSTRI - TM Lost River MA30 - 500,000

TMLOUDN - TM Loudoun MA30 - 500,000

TMLXP - TM LXP MA41 - 500,000

TMMXP - TM MXP MA42 - 500,000

----------------------------------------------------------------------------

LOGICAL METERS-- Non-Firm Available Capacity:

----------------------------------------------------------------------------

MLAPLGRV – Mainline Apple Grove - 500,000

MLCRWFRD - Mainline Crawford - 500,000

MLDRYCRE - Mainline Dry Creek - 500,000

MLEAGLE - Mainline Eagle - 500,000

MLLEACH - Mainline Leach - 500,000

MLLOUDOU - Mainline Loudoun - 500,000

MLLXPMAJ - Mainline LXP Majorsville - 500,000

MLNEWALB - Mainline New Albany - 500,000 

MLPETERS - Mainline Petersburg - 500,000

MLSDRCRK - Mainline Saunders Creek - 500,000

----------------------------------------------------------------------------

DUE PIPE AND DUE SHIPPER AVAILABILITY:

----------------------------------------------------------------------------

OP AREA 01 - Due Pipe - 0, Due Shipper - No Restriction

OP AREA 02 - Due Pipe - 0, Due Shipper - No Restriction

OP AREA 03 - Due Pipe - 0, Due Shipper - No Restriction

OP AREA 04 - Due Pipe - 0, Due Shipper - No Restriction 

OP AREA 05 - Due Pipe - 0, Due Shipper - No Restriction

OP AREA 06 - Due Pipe - 0, Due Shipper - No Restriction

OP AREA 07 - Due Pipe - 0, Due Shipper - No Restriction

OP AREA 08 - Due Pipe - 0, Due Shipper - No Restriction 

OP AREA 10 - Due Pipe - 0, Due Shipper - No Restriction

============================================================================

============================================================================

PAL & IT BUSINESS

Representatives are available daily to discuss PAL transactions with customers who have executed Master PAL Agreements. (Reminder: Each PAL transaction including rate, term, quantity and point(s) must be provided for and approved on the Appendix A under the Master PAL Agreement).Customers who are interested in discounted PAL transactions for next-day or long-term park and/or lend transactions or daily discounted IT paths should contact Diana Roberts at 832-320-5454 (ICE droberts6) or Adam Herndon at 832-689-4510 (ICE adherndon) for more information.

AUTO PAL AVAILABILITY

Effective with EVENING Cycle for each Gas Day, Auto Parks/Loans will be limited to +/-5,000 Dth.Customers are reminded the intent of AutoPAL service is to utilize nominal quantities to resolve pool imbalances that result from upstream or downstream reductions during the cycle.This service should not be used for parking or loaning large quantities.

The following services are eligible for Auto Park/Loan Paybacks and Auto Loan/Park Withdrawals:

IPP

SPP

A01 - Kenova

A02 - Flat Top

A03 - Cobb

A04 - Alexander 

A05 - Delmont 

A06 - McClellandtown

A08 - Crawford

A09 - York 

A10 - Dungannon 

A11 - Binghamton

A12 - Mountaineer Xpress

* Denotes a change from previous posting
El Paso Natural Gas (EPNG)

[MAINTENANCE] Updated September 2026 Maintenance

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Pipeline: El Paso Natural Gas (EPNG)
Notice Type: MAINTENANCE
Subject: Updated September 2026 Maintenance
Posted: 09/01/2026 2:52:10PM
Effective: 09/01/2026 2:52:10PM
End Date: 09/02/2026 9:00:00AM

TSP/TSP Name:  8001703-EL PASO NATURAL GAS CO. L.L.C. Critical: Y
Notice Type Desc (1):  MAINTENANCE Notice Type Desc (2):  MAINTENANCE
Notice Eff Date/Time:  09/01/2026 2:52:10PM Notice End Date/Time:  09/02/2026 9:00:00am
Post Date/Time:  9/1/2026 2:52:10 PM Notice ID: 629513
Reqrd Rsp:  5 Rsp Date/Time: 
Notice Stat Desc:  SUPERSEDE Prior Notice:  629481
Subject:  Updated September 2026 Maintenance
Notice Text:
EPNG Maintenance Calendar
September 2026
Seg Area
 
Seg Nbr
 
Flow Dir
 
Location
 
Base Capacity (MDth)
 
Tue
1
 
Wed
2
 
Thu
3
 
Fri
4
 
Sat
5
 
Sun
6
 
Mon
7
 
Tue
8
 
Wed
9
 
Thu
10
 
Fri
11
 
Sat
12
 
Sun
13
 
Mon
14
 
Tue
15
 
Wed
16
 
Thu
17
 
Fri
18
 
Sat
19
 
Sun
20
 
Mon
21
 
Tue
22
 
Wed
23
 
Thu
24
 
Fri
25
 
Sat
26
 
Sun
27
 
Mon
28
 
Tue
29
 
Wed
30
Anadarko
 
690
 
F
 
PLAIN ST
 
756
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
405
 
 
 
 
 
 
% Seg Avail
 
756
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
 
46%
Anadarko
 
715
 
B
 
PLAINS N
 
312
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
112
 
 
 
 
 
 
% Seg Avail
 
312
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
 
64%
Anadarko
 
740
 
B
 
AMAR N
 
292
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
33
 
 
 
 
 
 
% Seg Avail
 
292
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
Anadarko
 
740
 
F
 
AMAR S
 
309
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
53
 
 
 
 
 
 
% Seg Avail
 
309
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
 
83%
Anadarko
 
760
 
F
 
DUMAS S
 
310
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
37
 
37
 
37
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
% Seg Avail
 
310
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
88%
 
88%
 
88%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
Anadarko
 
780
 
B
 
DUMAS E
 
170
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
63
 
63
 
63
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
% Seg Avail
 
170
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
63%
 
63%
 
63%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
Lincoln Crossover
 
640
 
B
 
CAPROCK N
 
612
 
163
 
163
 
163
 
68
 
68
 
68
 
68
 
68
 
68
 
68
 
68
 
68
 
68
 
68
 
230
 
230
 
230
 
230
 
68
 
68
 
68
 
68
 
68
 
68
 
68
 
68
 
68
 
68
 
115
 
115
 
 
 
 
 
 
% Seg Avail
 
612
 
73%
 
73%
 
73%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
62%
 
62%
 
62%
 
62%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
89%
 
81%
 
81%
Lincoln Crossover
 
645
 
B
 
LUSK
 
284
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
22
 
 
 
 
 
 
% Seg Avail
 
284
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
 
92%
Line 1903
 
3000
 
F
 
MOJTHRU
 
463
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
117
 
117
 
117
 
117
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
% Seg Avail
 
463
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
75%
 
75%
 
75%
 
75%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
Mojave Seamless
 
3040
 
F
 
MOJAVE
 
400
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
54
 
54
 
54
 
54
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
% Seg Avail
 
400
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
87%
 
87%
 
87%
 
87%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
North Mainline
 
200
 
F
 
NORTH ML
 
2244
 
820
 
983
 
820
 
820
 
649
 
649
 
649
 
649
 
649
 
649
 
649
 
649
 
649
 
649
 
649
 
649
 
649
 
649
 
649
 
649
 
649
 
961
 
961
 
961
 
961
 
961
 
961
 
961
 
961
 
961
 
 
 
 
 
 
% Seg Avail
 
2244
 
63%
 
56%
 
63%
 
63%
 
71%
 
71%
 
71%
 
71%
 
71%
 
71%
 
71%
 
71%
 
71%
 
71%
 
71%
 
71%
 
71%
 
71%
 
71%
 
71%
 
71%
 
57%
 
57%
 
57%
 
57%
 
57%
 
57%
 
57%
 
57%
 
57%
Permian Virtual Segment
 
940
 
F
 
GUADLUP
 
1168
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
101
 
101
 
101
 
101
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Permian Virtual Segment
 
940
 
F
 
KEYST ST
 
781
 
229
 
229
 
229
 
229
 
229
 
229
 
229
 
229
 
229
 
229
 
229
 
229
 
229
 
229
 
558
 
558
 
558
 
558
 
229
 
229
 
229
 
229
 
229
 
229
 
229
 
229
 
229
 
229
 
229
 
229
Permian Virtual Segment
 
940
 
F
 
KEYSTAFL
 
750
 
198
 
198
 
198
 
198
 
198
 
198
 
198
 
198
 
198
 
198
 
198
 
198
 
198
 
198
 
527
 
527
 
527
 
527
 
198
 
198
 
198
 
198
 
198
 
198
 
198
 
198
 
198
 
198
 
198
 
198
Permian Virtual Segment
 
940
 
F
 
L2000
 
608
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
130
 
130
 
0
 
0
 
0
 
0
 
0
 
0
 
0
Permian Virtual Segment
 
940
 
F
 
PECOS
 
1195
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
123
 
123
 
123
 
123
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Permian Virtual Segment
 
940
 
F
 
PUC WAHA
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
 
130
Permian Virtual Segment
 
940
 
F
 
WA2CORN
 
734
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
67
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Permian Virtual Segment
 
940
 
 
 
314598 (IWARMONU)
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
85
 
 
 
 
 
 
% Seg Avail
 
85
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
 
0%
Permian Virtual Segment
 
940
 
 
 
377034 (ITEXNEUN)
 
76
 
76
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
% Seg Avail
 
76
 
0%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
South Mainline
 
1600
 
F
 
CORN HPW
 
586
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
 
76
South Mainline
 
1600
 
F
 
CORN LPW
 
1175
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
191
 
191
South Mainline
 
1600
 
F
 
CORNL2K
 
581
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
106
 
106
 
0
 
0
 
0
 
0
 
0
 
0
 
0
South Mainline
 
1600
 
F
 
CORNTRN
 
150
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
% Seg Avail
 
2492
 
97%
 
97%
 
97%
 
97%
 
97%
 
97%
 
97%
 
97%
 
97%
 
97%
 
97%
 
97%
 
97%
 
97%
 
97%
 
97%
 
97%
 
97%
 
97%
 
97%
 
97%
 
93%
 
93%
 
97%
 
97%
 
97%
 
97%
 
97%
 
89%
 
89%
South Mainline
 
1675
 
F
 
EL PASO
 
1243
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
South Mainline
 
1675
 
F
 
ELPASO C
 
584
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
South Mainline
 
1675
 
F
 
ELPASO E
 
578
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
 
 
 
 
 
% Seg Avail
 
2405
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
 
100%
South Mainline
 
1760
 
F
 
LORDS B
 
580
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
South Mainline
 
1760
 
F
 
LORDS C
 
574
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
103
 
103
 
0
 
0
 
0
 
0
 
0
 
0
 
0
South Mainline
 
1760
 
F
 
LORDSBRG
 
977
 
202
 
202
 
202
 
202
 
202
 
202
 
202
 
448
 
448
 
448
 
448
 
448
 
448
 
448
 
448
 
448
 
448
 
448
 
448
 
448
 
448
 
448
 
448
 
448
 
448
 
448
 
448
 
448
 
448
 
448
 
 
 
 
 
 
% Seg Avail
 
2131
 
87%
 
87%
 
87%
 
87%
 
87%
 
87%
 
87%
 
75%
 
75%
 
75%
 
75%
 
75%
 
75%
 
75%
 
75%
 
75%
 
75%
 
75%
 
75%
 
75%
 
75%
 
71%
 
71%
 
75%
 
75%
 
75%
 
75%
 
75%
 
75%
 
75%
South Mainline
 
1800
 
F
 
BOWIE
 
579
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
 
75
South Mainline
 
1800
 
F
 
CIMARRON
 
572
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
0
 
101
 
101
 
0
 
0
 
0
 
0
 
0
 
0
 
0
South Mainline
 
1800
 
F
 
DRAGOON
 
710
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
198
 
198
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
% Seg Avail
 
1861
 
96%
 
96%
 
96%
 
96%
 
96%
 
96%
 
96%
 
96%
 
96%
 
96%
 
96%
 
96%
 
96%
 
96%
 
96%
 
96%
 
96%
 
96%
 
96%
 
96%
 
96%
 
91%
 
91%
 
85%
 
85%
 
96%
 
96%
 
96%
 
96%
 
96%
Start Date
 
End Date
 
Region
 
Scheduling Location
 
Maintenance List
 
Base Capacity Dthd
 
Total Reduction Dthd
 
PLM Reduction Dthd
 
FMJ Reduction Dthd
 
Net Dthd
 
Update
09/01/26
 
09/01/26
 
NM
 
NORTH ML
 
Line 1201 pipeline remediation Window Rock to Navajo - Delayed
Williams C Station maintenance - Revised Capacity Impact Dth/d
Seligman C Station equipment failure repair - FMJ Reduction
 
                         2,244,804
 
                                 820,096
 
                                699,391
 
                               120,705
 
    1,424,708
 
09/02/26
 
09/02/26
 
NM
 
NORTH ML
 
Leupp Station maintenance - Revised Capacity Impact Dth/d
Line 1201 pipeline remediation Window Rock to Navajo - Delayed
Williams C Station maintenance - Revised Capacity Impact Dth/d
Seligman C Station equipment failure repair - FMJ Reduction
 
                         2,244,804
 
                                 983,554
 
                                862,849
 
                               120,705
 
    1,261,250
 
09/03/26
 
09/04/26
 
NM
 
NORTH ML
 
Line 1201 pipeline remediation Window Rock to Navajo - Delayed
Williams C Station maintenance - Revised Capacity Impact Dth/d
Seligman C Station equipment failure repair - FMJ Reduction
 
                         2,244,804
 
                                 820,096
 
                                699,391
 
                               120,705
 
    1,424,708
 
09/05/26
 
09/07/26
 
NM
 
NORTH ML
 
Williams C Station maintenance - Revised Capacity Impact Dth/d
 
                         2,244,804
 
                                 649,575
 
                                649,575
 
                                             -
 
    1,595,229
 
09/08/26
 
09/10/26
 
NM
 
NORTH ML
 
Line 1201 pipeline remediation Window Rock to Navajo - Delayed
Leupp 4A inspection
Williams C Station maintenance - Revised Capacity Impact Dth/d
 
                         2,244,804
 
                                 649,575
 
                                649,575
 
                                             -
 
    1,595,229
 
09/11/26
 
09/11/26
 
NM
 
NORTH ML
 
Line 1201 pipeline remediation Window Rock to Navajo - Delayed
Williams C Station maintenance - Revised Capacity Impact Dth/d
 
                         2,244,804
 
                                 649,575
 
                                649,575
 
                                             -
 
    1,595,229
 
09/12/26
 
09/21/26
 
NM
 
NORTH ML
 
Williams C Station maintenance - Revised Capacity Impact Dth/d
 
                         2,244,804
 
                                 649,575
 
                                649,575
 
                                             -
 
    1,595,229
 
09/22/26
 
09/28/26
 
NM
 
NORTH ML
 
Line 1201 pipeline remediation Window Rock to Navajo
Williams C Station maintenance - Revised Capacity Impact Dth/d
 
                         2,244,804
 
                                 961,356
 
                                961,356
 
                                             -
 
    1,283,448
 
09/29/26
 
09/30/26
 
NM
 
NORTH ML
 
Line 1201 pipeline remediation Window Rock to Navajo
Williams C Station maintenance - Revised Capacity Impact Dth/d
Window Rock 2A inspection
 
                         2,244,804
 
                                 961,356
 
                                961,356
 
                                             -
 
    1,283,448
 
09/15/26
 
09/16/26
 
MOJ
 
MOJTHRU
 
Mojave 1A inspection
 
                             463,000
 
                                 117,000
 
                                117,000
 
                                             -
 
        346,000
 
09/17/26
 
09/18/26
 
MOJ
 
MOJTHRU
 
Mojave 2A inspection
 
                             463,000
 
                                 117,000
 
                                117,000
 
                                             -
 
        346,000
 
09/15/26
 
09/16/26
 
MOJ
 
MOJAVE
 
Mojave 1A inspection
 
                             400,000
 
                                    54,000
 
                                  54,000
 
                                             -
 
        346,000
 
09/17/26
 
09/18/26
 
MOJ
 
MOJAVE
 
Mojave 2A inspection
 
                             400,000
 
                                    54,000
 
                                  54,000
 
                                             -
 
        346,000
 
09/01/26
 
09/03/26
 
XO
 
CAPROCK N
 
Caprock 2A equipment failure repair - FMJ Reduction
Lincoln Station maintenance
 
                             612,700
 
                                 163,132
 
                                  94,752
 
                                  68,380
 
        449,568
 
09/04/26
 
09/14/26
 
XO
 
CAPROCK N
 
Caprock 2A equipment failure repair - FMJ Reduction
 
                             612,700
 
                                    68,380
 
                                              -
 
                                  68,380
 
        544,320
 
09/15/26
 
09/18/26
 
XO
 
CAPROCK N
 
Caprock 2A equipment failure repair - FMJ Reduction
Bluewater Station DOT/ESD Tests
 
                             612,700
 
                                 230,668
 
                                162,288
 
                                  68,380
 
        382,032
 
09/19/26
 
09/28/26
 
XO
 
CAPROCK N
 
Caprock 2A equipment failure repair - FMJ Reduction
 
                             612,700
 
                                    68,380
 
                                              -
 
                                  68,380
 
        544,320
 
09/29/26
 
09/30/26
 
XO
 
CAPROCK N
 
Caprock 2A equipment failure repair - FMJ Reduction
Line 1301 cleaning and smart tools Belen to Laguna
 
                             612,700
 
                                 115,756
 
                                  47,376
 
                                  68,380
 
        496,944
 
09/01/26
 
09/30/26
 
XO
 
LUSK
 
Caprock 2A equipment failure repair - FMJ Reduction
 
                             284,900
 
                                    22,350
 
                                              -
 
                                  22,350
 
        262,550
 
09/01/26
 
09/30/26
 
AN
 
PLAINS N
 
Line No. 1102 anomaly repairs Plains to Dimmit - MLV 16 to MLV 14 - FMJ Reduction
 
                             312,900
 
                                 112,900
 
                                              -
 
                               112,900
 
        200,000
 
09/01/26
 
09/06/26
 
AN
 
AMAR N
 
Amarillo 2A equipment failure repair - FMJ Reduction
Dimmitt 5A maintenance
 
                             292,400
 
                                    33,328
 
                                              -
 
                                  33,328
 
        259,072
 
09/07/26
 
09/30/26
 
AN
 
AMAR N
 
Amarillo 2A equipment failure repair - FMJ Reduction
 
                             292,400
 
                                    33,328
 
                                              -
 
                                  33,328
 
        259,072
 
09/01/26
 
09/06/26
 
AN
 
AMAR S
 
Amarillo 2A equipment failure repair - FMJ Reduction
Dimmitt 5A maintenance
Line No. 1102 anomaly repairs Plains to Dimmit - MLV 16 to MLV 14 - FMJ Reduction
 
                             309,500
 
                                    53,853
 
                                              -
 
                                  53,853
 
        255,647
 
09/07/26
 
09/30/26
 
AN
 
AMAR S
 
Amarillo 2A equipment failure repair - FMJ Reduction
Line No. 1102 anomaly repairs Plains to Dimmit - MLV 16 to MLV 14 - FMJ Reduction
 
                             309,500
 
                                    53,853
 
                                              -
 
                                  53,853
 
        255,647
 
09/22/26
 
09/24/26
 
AN
 
DUMAS E
 
Dumas Station DOT/ESD Tests
 
                             170,000
 
                                    63,290
 
                                  63,290
 
                                             -
 
        106,710
 
09/22/26
 
09/24/26
 
AN
 
DUMAS S
 
Dumas Station DOT/ESD Tests
 
                             310,500
 
                                    37,734
 
                                  37,734
 
                                             -
 
        272,766
 
09/01/26
 
09/30/26
 
PR
 
PLAIN ST
 
Plains 7A repair
Plains 8A repair
Plains 11A repair
Plains 13A repair
Plains 14A repair
Plains 15A repair
Plains Station equipment failure repair - FMJ Reduction
 
                             756,100
 
                                 405,923
 
                                              -
 
                               405,923
 
        350,177
 
09/01/26
 
09/01/26
 
PR
 
377034
 
Texaco Eunice Receipt - (ITEXNEUN) - Eunice 3C inspection - Customer reduced to zero Dth/d during this outage
 
                               76,545
 
                                    76,545
 
                                  76,545
 
                                             -
 
                      -
 
09/01/26
 
09/30/26
 
PR
 
314598
 
Monument A Station equipment failure repair - Warren Monument Receipt (IWARMONU) - Customer to zero Dth/d during Monument A Station mechanical failure repair - FMJ Reduction
 
                               85,739
 
                                    85,739
 
                                              -
 
                                  85,739
 
                      -
 
09/01/26
 
09/14/26
 
PR
 
KEYST ST
 
Keystone 4A repair
Keystone 11A repair
Keystone 1B repair
Keystone 2B repair
 
                             781,000
 
                                 229,021
 
                                229,021
 
                                             -
 
        551,979
 
09/15/26
 
09/18/26
 
PR
 
KEYST ST
 
Keystone 4A repair
Keystone 11A repair
Keystone 1B repair
Keystone 2B repair
Keystone Station DOT/ESD Tests
 
                             781,000
 
                                 558,151
 
                                558,151
 
                                             -
 
        222,849
 
09/19/26
 
09/30/26
 
PR
 
KEYST ST
 
Keystone 4A repair
Keystone 11A repair
Keystone 1B repair
Keystone 2B repair
 
                             781,000
 
                                 229,021
 
                                229,021
 
                                             -
 
        551,979
 
09/01/26
 
09/14/26
 
PR
 
KEYSTAFL
 
Keystone 4A repair
Keystone 11A repair
Keystone 1B repair
Keystone 2B repair
 
                             750,400
 
                                 198,391
 
                                198,391
 
                                             -
 
        552,009
 
09/15/26
 
09/18/26
 
PR
 
KEYSTAFL
 
Keystone Station DOT/ESD Tests
 
                             750,400
 
                                 527,538
 
                                527,538
 
                                             -
 
        222,862
 
09/19/26
 
09/30/26
 
PR
 
KEYSTAFL
 
Keystone 4A repair
Keystone 11A repair
Keystone 1B repair
Keystone 2B repair
 
                             750,400
 
                                 198,391
 
                                198,391
 
                                             -
 
        552,009
 
09/01/26
 
09/30/26
 
PR
 
PUC WAHA
 
Puckett Station equipment failure repair - FMJ Reduction
 
                             130,900
 
                                 130,900
 
                                              -
 
                               130,900
 
                      -
 
09/08/26
 
09/11/26
 
SM
 
PECOS
 
Pecos River Station DOT/ESD Tests
 
                         1,195,600
 
                                 123,328
 
                                123,328
 
                                             -
 
    1,072,272
 
09/08/26
 
09/11/26
 
SM
 
GUADLUP
 
Pecos River Station DOT/ESD Tests
 
                         1,168,300
 
                                 101,079
 
                                101,079
 
                                             -
 
    1,067,221
 
09/15/26
 
09/28/26
 
SM
 
CORN LPW
 
Cornudas 3A maintenance - Cancelled
 
                         1,175,500
 
                                               -
 
                                              -
 
                                             -
 
    1,175,500
 
09/29/26
 
09/30/26
 
SM
 
CORN LPW
 
Cornudas 3A maintenance - Cancelled
Hueco Station DOT/ESD Tests
 
                         1,175,500
 
                                 191,169
 
                                191,169
 
                                             -
 
        984,331
 
09/01/26
 
09/07/26
 
SM
 
LORDSBRG
 
Line 1103 pipeline remediation Lordsburg to San Simon - Delayed
San Simon Station equipment failure repair - FMJ Reduction - Revised Capacity Impact Dth/d
 
                             977,700
 
                                 202,515
 
                                              -
 
                               202,515
 
        775,185
 
09/08/26
 
09/27/26
 
SM
 
LORDSBRG
 
Line 1103 pipeline remediation Lordsburg to San Simon - Revised Capacity Impact Dth/d
San Simon Station equipment failure repair - FMJ Reduction - Revised Capacity Impact Dth/d
 
                             977,700
 
                                 448,139
 
                                245,624
 
                               202,515
 
        529,561
 
09/28/26
 
09/29/26
 
SM
 
LORDSBRG
 
Line 1103 pipeline remediation Lordsburg to San Simon - Revised Capacity Impact Dth/d
San Simon Station equipment failure repair - FMJ Reduction - Revised Capacity Impact Dth/d
 
                             977,700
 
                                 448,139
 
                                245,624
 
                               202,515
 
        529,561
 
09/30/26
 
09/30/26
 
SM
 
LORDSBRG
 
Line 1103 pipeline remediation Lordsburg to San Simon - Revised Capacity Impact Dth/d
San Simon Station equipment failure repair - FMJ Reduction - Revised Capacity Impact Dth/d
San Simon Station maintenance - Cancelled
 
                             977,700
 
                                 448,139
 
                                245,624
 
                               202,515
 
        529,561
 
09/24/26
 
09/25/26
 
SM
 
DRAGOON
 
Dragoon Station inspection
 
                             710,200
 
                                 198,027
 
                                198,027
 
                                             -
 
        512,173
 
09/01/26
 
09/30/26
 
PR
 
WA2CORN
 
Gresham Station mechanical failure repair - FMJ Reduction
 
                             734,400
 
                                    67,738
 
                                              -
 
                                  67,738
 
        666,662
 
09/01/26
 
09/03/26
 
SM
 
CORN HPW
 
Lordsburg 1B maintenance
Gresham Station mechanical failure repair - FMJ Reduction
 
                             586,300
 
                                    76,968
 
                                     9,230
 
                                  67,738
 
        509,332
 
09/04/26
 
09/30/26
 
SM
 
CORN HPW
 
Lordsburg 1B maintenance
Gresham Station mechanical failure repair - FMJ Reduction
 
                             586,300
 
                                    76,968
 
                                     9,230
 
                                  67,738
 
        509,332
 
Update
09/01/26
 
09/03/26
 
SM
 
LORDS B
 
Lordsburg 1B maintenance
Gresham Station mechanical failure repair - FMJ Reduction
 
                             580,900
 
                                    75,298
 
                                     7,560
 
                                  67,738
 
        505,602
 
09/04/26
 
09/30/26
 
SM
 
LORDS B
 
Lordsburg 1B maintenance
Gresham Station mechanical failure repair - FMJ Reduction
 
                             580,900
 
                                    75,298
 
                                     7,560
 
                                  67,738
 
        505,602
 
Update
09/01/26
 
09/03/26
 
SM
 
BOWIE
 
Lordsburg 1B maintenance
Gresham Station mechanical failure repair - FMJ Reduction
 
                             579,000
 
                                    75,259
 
                                     7,521
 
                                  67,738
 
        503,741
 
09/04/26
 
09/30/26
 
SM
 
BOWIE
 
Lordsburg 1B maintenance
Gresham Station mechanical failure repair - FMJ Reduction
 
                             579,000
 
                                    75,259
 
                                     7,521
 
                                  67,738
 
        503,741
 
Update
09/01/26
 
09/21/26
 
PR
 
L2000
 
El Paso 4D equipment failure repair - Completed
 
                             608,300
 
                                               -
 
                                              -
 
                                             -
 
        608,300
 
09/22/26
 
09/23/26
 
PR
 
L2000
 
El Paso 4D equipment failure repair - Completed
Cimarron Station inspection
 
                             608,300
 
                                 130,539
 
                                130,539
 
                                             -
 
        477,761
 
09/24/26
 
09/30/26
 
PR
 
L2000
 
El Paso 4D equipment failure repair - Completed
 
                             608,300
 
                                               -
 
                                              -
 
                                             -
 
        608,300
 
09/01/26
 
09/21/26
 
SM
 
CORNL2K
 
El Paso 4D equipment failure repair - Completed
 
                             581,200
 
                                               -
 
                                              -
 
                                             -
 
        581,200
 
09/22/26
 
09/23/26
 
SM
 
CORNL2K
 
El Paso 4D equipment failure repair - Completed
Cimarron Station inspection
 
                             581,200
 
                                 106,195
 
                                106,195
 
                                             -
 
        475,005
 
09/24/26
 
09/30/26
 
SM
 
CORNL2K
 
El Paso 4D equipment failure repair - Completed
 
                             581,200
 
                                               -
 
                                              -
 
                                             -
 
        581,200
 
09/01/26
 
09/30/26
 
SM
 
ELPASO E
 
El Paso 4D equipment failure repair - Completed
 
                             578,900
 
                                               -
 
                                              -
 
                                             -
 
        578,900
 
09/01/26
 
09/21/26
 
SM
 
LORDS C
 
El Paso 4D equipment failure repair - Completed
 
                             574,400
 
                                               -
 
                                              -
 
                                             -
 
        574,400
 
09/22/26
 
09/23/26
 
SM
 
LORDS C
 
El Paso 4D equipment failure repair - Completed
Cimarron Station inspection
 
                             574,400
 
                                 103,774
 
                                103,774
 
                                             -
 
        470,626
 
09/24/26
 
09/30/26
 
SM
 
LORDS C
 
El Paso 4D equipment failure repair - Completed
 
                             574,400
 
                                               -
 
                                              -
 
                                             -
 
        574,400
 
09/01/26
 
09/21/26
 
SM
 
CIMARRON
 
El Paso 4D equipment failure repair - Completed
 
                             572,200
 
                                               -
 
                                              -
 
                                             -
 
        572,200
 
09/22/26
 
09/23/26
 
SM
 
CIMARRON
 
El Paso 4D equipment failure repair - Completed
Cimarron Station inspection
 
                             572,200
 
                                 101,574
 
                                101,574
 
                                             -
 
        470,626
 
09/24/26
 
09/30/26
 
SM
 
CIMARRON
 
El Paso 4D equipment failure repair - Completed
 
                             572,200
 
                                               -
 
                                              -
 
                                             -
 
        572,200
 
In addition to planned outages, this report reflects the repairs and maintenance being performed related to Force Majeure events.
Due to the nature of such events, the dates for the associated repairs and maintenance of those events are assumed to extend until the end of the month.
These repairs and maintenance, however, may extend beyond the end of the month including beyond the current year.
More information on these repairs and maintenance will be posted as a Critical Notice under the Notices section of the Informational Postings tab on the EPNG Electronic Bulletin Board.
Northwest Pipeline

Sumas Compressor Station Deficiency Period Part 2

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Pipeline: Northwest Pipeline
Notice: Sumas Compressor Station Deficiency Period Part 2
Notice ID: 33008

Capacity

Operationally Available
Unsubscribed

Gas Quality

Gas Quality
Gas Quality Tariff Provisions
Gas Quality Sampling Procedures
 Gas Quality Resolution Report
RNG Operating Policy

Index of Customers

Locations

Notices

Critical
Non-Critical
Planned Service Outage
Request to Purchase Releasable Capacity
Waste Heat

Posted Imbalances

Regulatory

FERC Watch
Proposed Tariff Filings

Standards of Conduct

Affiliate Names & Addresses
Affiliate Tariff Waivers
Chief Compliance Officer
Employee Transfers
Implementation Procedures
Information Disclosure
Job Titles & Descriptions
Potential Mergers
Shared Facilities
Voluntary Consent

Tariff

Title Sheet/Section
Table Of Contents
Preliminary Statement
Map
Currently Effective Rates
Rate Schedules
General Terms and Conditions
Form Of Service Agreement
 Entire Tariff
Sheet/Section Index

Transactional Reporting

Capacity Release
Firm
Interruptible

Capacity Release Indices

TSP Capacity Offering

Maintenance Schedule

Commercial Contacts

Agreements/Forms

Portal History

Other

Downloads

Search

Search - Tariff
Search - Rate Schedules
Search - General Terms
Search - Form of Service Agreement
Search - Entire Portal

Customer Activities

Site Map

Northwest Pipeline LLC Notice Detail

Print

Northwest Pipeline LLC

NOTICE # 26-171

Sumas Compressor Station Deficiency Period Part 2

 posted on
 
Sep 1 2026 3:20PM

TSP Name: Northwest Pipeline LLC TSP: 67977322

Critical: Y
Notice Stat Desc: SUPERSEDE
Notice Type Desc: CURTAILMENT
Post D/T: 09/01/2026 3:01 PM MCT
Notice Eff D/T: 09/01/2026 3:01 PM MCT
Notice End D/T: 
Reqrd Rsp Desc: No response required
Rsp D/T: 

Notice ID: 26-171
Prior Notice: 26-162
Subject: Sumas Compressor Station Deficiency Period Part 2

Notice Text:

As indicated in All Shippers Notice #26-162, Northwest is 
currently performing maintenance at the Sumas CS through 
September 09, 2026.
  
 
Primary southbound nomination requests at the Sumas CS have 
exceeded the available capacity of 821,000 Dth/d southbound (or 
whatever Northwest cannot mitigate). Therefore, pursuant to 
Sections 10.2 and 10.3 of Rate Schedule TF-1 in Northwest's 
Tariff, Northwest hereby gives notice of a Deficiency Period 
for Gas Day September 02, 2026. The Deficiency will be 
calculated based on a design capacity of 1,409,000 Dth/d 
southbound. The Deficiency Period will continue until the work 
is completed. Northwest will post on its EBB if unable to 
mitigate volumes each day until the work is completed.
 
Please reference the Maintenance Schedule tab at 
www.northwest.williams.com
 for more information.
 
 
If you have any questions, please call your Commercial Services 
Representative or the hotline at 713-215-6301.
Iroquois Gas Transmission

Capacity Constraint

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Capacity Constraint Effective Timely Cycle, Gas Day September 2, 2026, nominations are sealed from all increases through the following locations: - Brookfield Interconnect with Algonquin Gas Transmission. In addition, the following capacity has been reduced: - Brookfield Interconnect – Park, Interruptible and Secondary receipt nominations are reduced by 100%. If you have any further questions, please contact the Iroquois Scheduling or Gas Control Group. End date 09/03/2026 09:00 AM CCT
NEXUS Gas Transmission (U.S.)

09/01/2026- NEXUS Pipeline Conditions for 09/02/2026

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name: NEXUS Gas Transmission, LLC (U.S.)
Subject: NEXUS Pipeline Conditions for 09/02/2026
Notice Type: Capacity Constraint
Critical Notice Description: Critical notice
Notice Status Description: Initiate
Notice Effective Date: 09/02/2026
Notice End Date: 09/03/2026
Posting Date: 09/01/2026
Notice Identifier: 182433
Required Response Indicator Description: No response required

For Gas Day September 2, 2026, Nexus Gas Transmission, LLC (NEXUS) has approved and scheduled nominations at each pipeline segment and meter station up to NEXUS's operational capacity. The following locations have been restricted due to requested nominations exceeding NEXUS's operational capacity:
Restricted Locations
Scheduled and Sealed
Priority % Restricted
Notes
TABS
Belle River
N/A
100%
100%
100%
100%
100%
100%
41%
Due to DTE Posted Outage
Ypsilanti
N/A
100%
100%
100%
100%
100%
100%
38%
Due to DTE Posted Outage
OFO / Imbalance Notice
OFO
---
Customer Specific OFO
No DP - issued 8/20/2026. 2% / 500 Dth/d Tolerance
Imbalances Warnings
Stay Balanced
Gas Quality:
NEXUS has been informed by TETCO of ongoing gas quality issues at meters N4714, N4733, N4915. TE/NEXUS will require a partial reduction of flow beginning as soon as September 9, 2026, if gas quality issues are not corrected by that date. These meter operators will remain at a reduced flow, and will be subject to further reductions, until the gas entering TE's system is compliant with TE's gas quality standards in its GT&C. The upstream point operators are required to ensure nominations are commensurate with the physical flow, or non-performance confirmation reductions may be required.
Systemwide Notes:
Customers are advised that capacity may become available as the nomination and confirmation process continues throughout the day.
Please contact your Operations Account Representative should you have any questions.
NEXUS Gas Transmission (U.S.)

09/01/2026- NEXUS Pipeline Conditions for 09/02/2026 -- INTRADAY

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name: NEXUS Gas Transmission, LLC (U.S.)
Subject: NEXUS Pipeline Conditions for 09/02/2026 -- INTRADAY
Notice Type: Capacity Constraint
Critical Notice Description: Critical notice
Notice Status Description: Supersede
Notice Effective Date: 09/02/2026
Notice End Date: 09/03/2026
Posting Date: 09/01/2026
Notice Identifier: 182466
Prior Notice Identifier: 182433
Required Response Indicator Description: No response required

For Gas Day September 2, 2026, Nexus Gas Transmission, LLC (NEXUS) has approved and scheduled nominations at each pipeline segment and meter station up to NEXUS's operational capacity. The following locations have been restricted due to requested nominations exceeding NEXUS's operational capacity:
Restricted Locations
Scheduled and Sealed
Priority % Restricted
Notes
TABS
Belle River
N/A
100%
100%
100%
100%
100%
100%
41%
Due to DTE Posted Outage
Ypsilanti
N/A
100%
100%
100%
100%
100%
100%
38%
Due to DTE Posted Outage
Salinville (1)
Yes
OFO / Imbalance Notice
OFO
---
Customer Specific OFO
No DP - issued 8/20/2026. 2% / 500 Dth/d Tolerance
Imbalances Warnings
Stay Balanced
Gas Quality:
NEXUS has been informed by TETCO of ongoing gas quality issues at meters N4714, N4733, N4915. TE/NEXUS will require a partial reduction of flow beginning as soon as September 9, 2026, if gas quality issues are not corrected by that date. These meter operators will remain at a reduced flow, and will be subject to further reductions, until the gas entering TE's system is compliant with TE's gas quality standards in its GT&C. The upstream point operators are required to ensure nominations are commensurate with the physical flow, or non-performance confirmation reductions may be required.
Systemwide Notes:
(1) Due to Intraday Nomination Changes
Customers are advised that capacity may become available as the nomination and confirmation process continues throughout the day.
Please contact your Operations Account Representative should you have any questions.
Columbia Gas Transmission (TCO)

Hubball & Kenova Compressor Station Maintenance, September 8-11, 2026

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name Columbia Gas Transmission, LLC
TSP 054748041
Notice Type Description: Maintenance

Notice Stat Desc: Initiate

Prior Notice: 

Critical: Y

Reqrd Rsp Desc: No Response Required
Post

Notice Effective

Notice End



Response
Post Date: 09/01/26

09/01/26

10/01/26
Subject: Subject: Hubball & Kenova Compressor Station Maintenance, September 8-11, 2026
Author: Author: Dillon Schoolcraft
Notice Text
Columbia Gas Transmission, LLC (TCO) reminds customers of upcoming maintenance at Hubball and Kenova Compressor Stations beginning Tuesday, September 8, 2026, and continuing through Friday, September 11, 2026. In an effort to minimize the commercial impact during the holiday trading period, there will be no commercial restrictions on Gas Day September 8, 2026. 

Based on forecasted operating conditions, TCO does not currently anticipate any reduction to firm nominations during the maintenance; however, firm reductions at the following locations may become necessary:

CNR06 – CHK-Hubball/Horse Ck/Nye

CHSTKENO – Line P North MA16

MAYTHUFF – KA Low MA16

TCO encourages customers to monitor the Construction and Maintenance Schedule for any potential non-firm impact, as well as the Daily Capacity Posting for the specific capacity setting each day of the outage.

Reservation charge credits (RCCs) will be determined per the process set forth in the General Terms and Conditions, Section 38 of TCO’s FERC Gas Tariff (“Tariff”). However, TCO will only issue RCCs if TCO is unable to schedule or deliver primary firm nominated capacity as a result of the outage. In the event RCCs are issued as set forth in the Tariff, shippers will receive RCCs based on its 7-day average usage quantity less any scheduled quantities on the contract. By means of this notice, TCO is establishing which specific Gas Days will be included when determining a shipper’s 7-day average usage quantity pursuant to the provisions in the Tariff.

Please contact your Customer Services Representative with any questions.
Columbia Gas Transmission (TCO)

Line 1711 Pipeline Maintenance, September 8-22, 2026

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name Columbia Gas Transmission, LLC
TSP 054748041
Notice Type Description: Maintenance

Notice Stat Desc: Initiate

Prior Notice: 

Critical: Y

Reqrd Rsp Desc: No Response Required
Post

Notice Effective

Notice End



Response
Post Date: 09/01/26

09/01/26

10/01/26
Subject: Subject: Line 1711 Pipeline Maintenance, September 8-22, 2026
Author: Author: Dillon Schoolcraft
Notice Text
Columbia Gas Transmission, LLC (TCO) reminds customers of maintenance on Line 1711 beginning Tuesday, September 8, 2026, through Tuesday, September 22, 2026. Dut to this maintenance, the impacted locations will be required to be physically shut in on Tuesday, September 8, 2026. However, in an effort to minimize commercial impact for the holiday weekend, the following location will be taken to Zero Total Capacity effective Timely Cycle Gas for Day Wednesday, September 9, 2026;

637095 – MTN GATHERING-HOMER CITY 

TCO encourages customers to reference the Construction and Maintenance Schedule and the Daily Capacity Posting for any non-firm adjustments related to this maintenance. 

Reservation charge credits (RCCs) will be determined per the process set forth in the General Terms and Conditions, Section 38 of TCO’s FERC Gas Tariff (“Tariff”). However, TCO will only issue RCCs if TCO is unable to schedule or deliver primary firm nominated capacity as a result of the outage. In the event RCCs are issued as set forth in the Tariff, shippers will receive RCCs based on its 7-day average usage quantity less any scheduled quantities on the contract. By means of this notice, TCO is establishing which specific Gas Days will be included when determining a shipper’s 7-day average usage quantity pursuant to the provisions in the Tariff.

Please contact your Customer Services Representative with any questions.
Tennessee Gas Pipeline (TGP)

STA 538 - Unit 1C PM

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Interstate
Other
Midstream
Informational Postings
Capacity
Gas Electric Coordination
Gas Quality
Index of Customers
Locations
Notices
Posted Imbalances
Regulatory
Standards of Conduct
Tariff
Transactional Reporting
Info Lookup
Other
Downloads
Search
Customer Activities
Site Map
	
	
NOTICE DETAIL
	
PDF
TEXT
Return To Results
TSP/TSP Name:  1939164-TENNESSEE GAS PIPELINE	Critical: Y
Notice Type Desc (1):  MAINTENANCE	Notice Type Desc (2):  MAINTENANCE
Notice Eff Date/Time:  09/01/2026 7:35:47AM	Notice End Date/Time:  09/02/2026 9:00:00am
Post Date/Time:  9/1/2026 7:35:47 AM	Notice ID: 403907
Reqrd Rsp:  1	Rsp Date/Time:  9/1/2026 12:00:00 AM
Notice Stat Desc:  INITIATE	Prior Notice: 
Subject:  STA 538 - Unit 1C PM
Notice Text:

Project Updates

 

“***Sta 538:  Unit 1C - Preventive Maintenance
--9/2/26 through 9/3/26:  This project will require a unit outage, which will limit throughput through the station and result in restrictions based on customer nominations. 
***
Date Change, Previously scheduled 9/1/26 to 9/2/26.
………………………………”

 

 

If you have any questions, please contact your Scheduler.

..
Florida Gas Transmission

[Florida Gas Transmission] [Operational Alert] Overage Alert Day 15% Tolerance

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Pipeline: Florida Gas Transmission
Notice ID: 68218
Notice Type: Operational Alert
Subject: Overage Alert Day 15% Tolerance
Posted: Sep 1 2026 6:25 AM
Effective: Sep 1 2026 9:00 AM
End Date: Sep 2 2026 9:00 AM

Notice ID: 68218
Notice Type: Operational Alert
Critical: Y
Notice Status Description: Initiate
Reqrd Rsp Desc: No Response Required
Posting Date/Time: Sep 1 2026 6:25 AM
Subject: Overage Alert Day 15% Tolerance
Notice Effective Date/Time: Sep 1 2026 9:00 AM
Notice End Date/Time: Sep 2 2026 9:00 AM
Notice Text: 90-degree temperatures are forecasted in Florida over the next several days and FGT linepack is below target levels; therefore, for the gas day of September 1, 2026, FGT would like to notify their customers in the FGT Market Area that it is issuing an Overage Alert Day at 15% (Fifteen Percent) tolerance.For the gas day of September 1, 2026, FGT will not interrupt previously scheduled Market Area ITS-1 service below the elapsed prorated scheduled quantity.FGT will continue to monitor hourly and daily takes. Please closely monitor your scheduled point quantities versus actual burn point quantities.
Gulf South Pipeline

Unplanned Index 296 Pipeline Maintenance

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Pipeline: Gulf South Pipeline
Notice ID: 5038650
Notice Type: Maintenance
Status: Initiate
Posted: 2026-09-01T11:39:00+00:00
Effective: 2026-09-02T09:00:00+00:00
End: 
Subject: Unplanned Index 296 Pipeline Maintenance

Gulf South Pipeline Notice 5038650
Source Link
All information here is provided as a service and information is not guaranteed to be accurate. PipeRiv is not responsible for any incorrect information.
TSP Name :
Gulf South Pipeline Company, LLC
Category :
Critical
Notice Type Desc :
Maintenance
Notice Stat Desc :
Initiate
Notice ID :
5038650
Prior Notice :
Reqrd Rsp Desc :
No response required
Subject :
Unplanned Index 296 Pipeline Maintenance
TSP :
078444247
Post Date/Time :
09/01/2026 11:39:00 AM
Notice Effective Date/Time :
09/02/2026 09:00:00 AM
Notice End Date/Time :
Response Date/Time :
Critical :
Notice Text :
Gulf South is performing unplanned maintenance on Index 296.
Lower than normal operating conditions are expected, however, the following scheduling group will
be impacted:
Index 296 Harvey West Scheduling Group
Capacity could be impacted by as much as 90,000 dth/d for the duration of the maintenance.
This maintenance has the potential to impact all services, including Primary Firm Service.
Demand charge credits will not be issued during the maintenance period unless Primary Firm
Service is scheduled down during the Timely Nomination Cycle. Any demand charge credits will be
calculated pursuant to Section 6.25 of the General Terms and Conditions of Gulf South`s NGA Gas
Tariff.
As more information is provided, we will update as appropriate.
If you have any questions, please contact your customer service representative.
Notice
Page 1 of 1
09/01/2026 11:40:26 AM
Notice
TSP Name :
Gulf South Pipeline Company, LLC
TSP :
078444247
Category :
Critical
Post Date/Time :
09/01/2026 11:39:00 AM
Notice Type Desc :
Maintenance
Notice Effective Date/Time :
09/02/2026 09:00:00 AM
Notice Stat Desc :
Initiate
Notice End Date/Time :
Notice ID :
5038650
Response Date/Time :
Prior Notice :
Critical :
Reqrd Rsp Desc :
No response required
Subject :
Unplanned Index 296 Pipeline Maintenance
Notice Text :
Gulf South is performing unplanned maintenance on Index 296.
Lower than normal operating conditions are expected, however, the following scheduling group will
be impacted:
Index 296 Harvey West Scheduling Group
Capacity could be impacted by as much as 90,000 dth/d for the duration of the maintenance.
This maintenance has the potential to impact all services, including Primary Firm Service.
Demand charge credits will not be issued during the maintenance period unless Primary Firm
Service is scheduled down during the Timely Nomination Cycle. Any demand charge credits will be
calculated pursuant to Section 6.25 of the General Terms and Conditions of Gulf South`s NGA Gas
Tariff.
As more information is provided, we will update as appropriate.
If you have any questions, please contact your customer service representative.
09/01/2026 11:40:26 AM
Page 1 of 1
Transco

Operational Flow Order - Imbalance

SEV 2/5
Informational

Pre-screen severity 2 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Pipeline: Transco
Notice: Operational Flow Order - Imbalance
Posted: 09/01/2026 14:24:04 CDT
Notice ID: 17231075

TRANSCONTINENTAL GAS PIPE LINE COMPANY, LLC

Critical:
 Y

Notice Eff Date:
 09/01/2026

Notice Eff Time:
 09:00:00 CDT

Notice End Date:
 09/05/2026

Notice End Time:
 09:00:00 CDT

Notice ID:
 17231075

Notice Stat Desc:
 Supersede

Notice Type Desc:
 OFO

Post Date:
 09/01/2026

Post Time:
 14:24:04 CDT

Prior Notice:
 17217327

Reqrd Rsp Desc:
 Immediate response required of an operational nature may be required of impacted shippers

Rsp Date:
 

Rsp Time:
 

TSP:
 007933021

TSP Name:
 TRANSCONTINENTAL GAS PIPE LINE COMPANY, LLC

Notice Text: 
Subject: 
Operational Flow Order - Imbalance
Transco provides notice of limited flexibility to manage imbalances on its system due to extreme hot temperatures forecasted in zone(s) 5 and 6. In order to maintain operational pressures and adequate gas supplies required to provide an efficient and reliable firm service, Transco is issuing an Operational Flow Order (OFO) pursuant to Section 52 of its General Terms and Conditions of it’s Tariff.
 
Please refer to the table below for the effected zones, dates and tolerance percentages.
Beginning Gas Day:
Tuesday,
September 1, 2026
9:00AM CT
Ending Gas Day:
Saturday,
September 5, 2026
9:00 AM CT
OFO Area(s):
Zone 5, 6
Tariff Reference for OFO Issuance:*
(b), (d)
Type of OFO:
Imbalance
Type of Imbalance:
Due From Shipper
Transactions Include:
Deliveries**
Beginning Cycle:
Timely
Tolerance % Allowed (or 1000  dth, Zone whichever  is greater):
Due From Shipper 7%
Affected Shipper(s)  (DUNS #):****
 
Affected Location(s) (DRN  #/Loc ID):*****
All
Retro Scheduling Available
Yes
OBA Subject to OFO:
No
If Yes, OBA Parties   (DUNS #):***
 
 
*Circumstances under which Seller may determine that an OFO must be issued include, but are not limited to in Section 52.2 of Transco's FERC Gas Tariff General Terms and Conditions: 
Responding to an event of force majeure; 
Accommodating capacity limitations resulting from the need to perform maintenance and/or repairs; 
Ensuring current and future storage capabilities and maintenance of line pack; 
Maintaining operational pressures and adequate gas supplies required to provide an efficient and reliable firm service;
Responding to any event which Seller believes in its sole judgment may jeopardize the integrity of its system.
** OFO based on all transactions with deliveries in affected OFO area.                                
***OFO based on all transactions with receipts in affected OFO area.                                 
**** If specific DUNS #s have been identified, only imbalances created by those shippers/OBA parties will be subject to the OFO provisions.
*****If specific DRN #/Loc ID's have been identified, only imbalances created at those location(s) will be subject to the OFO provisions.
This OFO is directed to shippers consistent with Section 52 of Transco's FERC Gas Tariff General Terms and Conditions with a minimum of $50 per dt per day penalty. This OFO will continue until further notice. Buyers with imbalances greater than the allowed tolerance will be subject to penalties specified in Section 52 of Transco's FERC Gas Tariff General Terms and Conditions.                                       
Additional information on Operational Flow Orders is available at this link:         
http://www.1line.williams.com/Transco/files/training/Critical_Day.pdf
                        
Please contact your Transportation Services Representative if you have any questions.
Northwest Pipeline

Buhl CS - Unplanned Maintenance

UNSCORED
Informational
View original notice text
Pipeline: Northwest Pipeline
Notice: Buhl CS - Unplanned Maintenance
Notice ID: 33016

Capacity

Operationally Available
Unsubscribed

Gas Quality

Gas Quality
Gas Quality Tariff Provisions
Gas Quality Sampling Procedures
 Gas Quality Resolution Report
RNG Operating Policy

Index of Customers

Locations

Notices

Critical
Non-Critical
Planned Service Outage
Request to Purchase Releasable Capacity
Waste Heat

Posted Imbalances

Regulatory

FERC Watch
Proposed Tariff Filings

Standards of Conduct

Affiliate Names & Addresses
Affiliate Tariff Waivers
Chief Compliance Officer
Employee Transfers
Implementation Procedures
Information Disclosure
Job Titles & Descriptions
Potential Mergers
Shared Facilities
Voluntary Consent

Tariff

Title Sheet/Section
Table Of Contents
Preliminary Statement
Map
Currently Effective Rates
Rate Schedules
General Terms and Conditions
Form Of Service Agreement
 Entire Tariff
Sheet/Section Index

Transactional Reporting

Capacity Release
Firm
Interruptible

Capacity Release Indices

TSP Capacity Offering

Maintenance Schedule

Commercial Contacts

Agreements/Forms

Portal History

Other

Downloads

Search

Search - Tariff
Search - Rate Schedules
Search - General Terms
Search - Form of Service Agreement
Search - Entire Portal

Customer Activities

Site Map

Northwest Pipeline LLC Notice Detail

Print

Northwest Pipeline LLC

NOTICE # 26-176

Buhl CS - Unplanned Maintenance

 posted on
 
Sep 9 2026 3:36PM

TSP Name: Northwest Pipeline LLC TSP: 67977322

Critical: Y
Notice Stat Desc: INITIATE
Notice Type Desc: MAINTENANCE
Post D/T: 09/09/2026 3:35 PM MCT
Notice Eff D/T: 09/10/2026 3:35 PM MCT
Notice End D/T: 
Reqrd Rsp Desc: No response required
Rsp D/T: 

Notice ID: 26-176
Prior Notice: 
Subject: Buhl CS - Unplanned Maintenance

Notice Text:

Northwest has identified the need for an immediate dig/repair 
near the Buhl CS from the data received from the Burley to 
Snake River ILI runs performed earlier in the year. Initial 
assessments indicate this outage is expected to last up to 2 
weeks to complete the work.
Effective Gas Day September 11, 2026, through Gas Day September 
25, 2026, the available capacity at the Buhl CS (located at MP 
729.8 in Twin Falls County, Idaho) will be limited to 366,000 
Dth/d northbound.
If primary nomination requests through the Buhl CS exceeds 
the available capacity of 366,000 Dth/d northbound (or whatever 
NWP cannot mitigate during any day of the maintenance), 
pursuant to Sections 10.2 and 10.3 of Rate Schedule TF-1 in 
Northwest's Tariff, Northwest will give notice of a Declared 
Deficiency Period based on a design capacity of 578,000 Dth/d 
Northbound. The deficiency period will continue until the work 
has been completed. 
Northwest is doing everything possible to complete the work as 
quickly and safely as possible and will provide updates on our 
EBB as additional information becomes available. 
Please reference the Maintenance Schedule tab at 
www.northwest.williams.com for more information.
If you have any questions, please call your Commercial Services 
Representative or the hotline at 713-215-6301.
Tennessee Gas Pipeline (TGP)

EMERGENT REPAIR AT MLV 258-2 TO 259-2

UNSCORED
Informational
View original notice text
Interstate
Other
Midstream
Informational Postings
Capacity
Gas Electric Coordination
Gas Quality
Index of Customers
Locations
Notices
Posted Imbalances
Regulatory
Standards of Conduct
Tariff
Transactional Reporting
Info Lookup
Other
Downloads
Search
Customer Activities
Site Map
	
	
NOTICE DETAIL
	
PDF
TEXT
Return To Results
TSP/TSP Name:  1939164-TENNESSEE GAS PIPELINE	Critical: Y
Notice Type Desc (1):  MAINTENANCE	Notice Type Desc (2):  MAINTENANCE
Notice Eff Date/Time:  09/09/2026 3:59:52PM	Notice End Date/Time:  09/10/2026 9:00:00am
Post Date/Time:  9/9/2026 3:59:52 PM	Notice ID: 404094
Reqrd Rsp:  1	Rsp Date/Time:  9/9/2026 12:00:00 AM
Notice Stat Desc:  INITIATE	Prior Notice: 
Subject:  EMERGENT REPAIR AT MLV 258-2 TO 259-2
Notice Text:

EMERGENT REPAIR BETWEEN MLV 258-2 TO 259-2 EFFECTIVE 9-9-2026

 

Pursuant to Article XII of the General Terms and Conditions of Tennessee's FERC Gas Tariff, Tennessee is posting notice of an emergent repair issue in Berkshire County MA.  Tennessee has identified an issue which necessitates immediate repairs.  Personnel are onsite and evaluating the repairs. Tennessee is estimating the impact to be up to 550,000 dths pathed through Segment 249 FH.  Based upon current nominations, restrictions through a pro rata portion of Secondary Out of the Path nominations pathed through Segment 249 FH are at risk as early as Timely Cycle for the Gas Day of Friday, September 11, 2026.  Previously scheduled volumes pathed through Segment 249 FH will not be curtailed; however, all increases pathed through Segment 249 FH for the remainder of today's Gas Day, September 9, 2026 and Gas Day Thursday, September 10, 2026 are at risk. 

 

Updates will be posted as more information becomes available.

 

Please contact your Scheduler if you have any questions.

..
Corpus Christi LNG

Quorum Server Maintenance September 09, 2026 – 7:15PM to 8:15PM (CST)

SEV 1/5
Informational

Pre-screen severity 1 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Facility: Corpus Christi LNG
Notice ID: 1991
Notice Type: Computer System Status
Status: Active
Title: Quorum Server Maintenance September 09, 2026 – 7:15PM to 8:15PM (CST)
Effective Date/Time: 2026-09-09T17:02:00
End Date/Time: 2026-12-09T00:00:00
Posted: 2026-09-09T17:05:17.717
Note: Effective/End Date above is the posting's overall coverage window, NOT necessarily one continuous outage -- see Notice Text and/or the embedded image below for the actual per-job schedule.

Notice Text:
To provide you greater support and service, we will be performing server maintenance to the Quorum System.   As the result of this maintenance, the system may be unavailable:   Wednesday September 09, 2026, from 7:15 p.m. – 8:15 p.m. (CST)   Please note that changes made to the Customer Activities Website during this outage may not take effect.   We apologize for any inconvenience this may cause you.     If you have any questions, please contact Customer Services at 713-375-5900 or email Cheniere.CTPL@Cheniere.com .
Columbia Gas Transmission (TCO)

Construction and Maintenance Schedule Posting

SEV 1/5
Informational

Pre-screen severity 1 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name Columbia Gas Transmission, LLC
TSP 054748041
Notice Type Description: Maintenance

Notice Stat Desc: Initiate

Prior Notice: 

Critical: Y

Reqrd Rsp Desc: No Response Required
Post

Notice Effective

Notice End



Response
Post Date: 09/09/26

09/09/26

10/09/26
Subject: Subject: Construction and Maintenance Schedule Posting
Author: Author: Dillon Schoolcraft
Notice Text
As a courtesy, Columbia Gas Transmission, LLC (TCO) hereby notifies customers the Construction and Maintenance Schedule posted under "Construction and Maintenance" on the Informational Postings website has been updated. TCO reminds customers to please check the Maintenance Schedule on a regular basis.

The current schedule has been updated to reflect maintenance activity on the following:

* Revised end date – Line 1758 Pipeline Maintenance – July 8 – September 21, 2026 (Previously scheduled to end on September 5, 2026)

Additionally, the following file(s) can be located on Informational Postings under Construction and Maintenance

TCO Construction and Maintenance Schedule 09-09-2026.pdf
Gulf South Pipeline

Posted Maintenance Events for 09/11/2026 - 09/17/2026

SEV 1/5
Informational

Pre-screen severity 1 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Pipeline: Gulf South Pipeline
Notice ID: 5038688
Notice Type: Maintenance
Status: Initiate
Posted: 2026-09-09T14:23:00+00:00
Effective: 2026-09-11T09:00:00+00:00
End: 2026-09-18T09:00:00+00:00
Subject: Posted Maintenance Events for 09/11/2026 - 09/17/2026

Gulf South Pipeline Notice 5038688
Source Link
All information here is provided as a service and information is not guaranteed to be accurate. PipeRiv is not responsible for any incorrect information.
TSP Name :
Gulf South Pipeline Company, LLC
Category :
Critical/Planned Service Outage
Notice Type Desc :
Maintenance
Notice Stat Desc :
Initiate
Notice ID :
5038688
Prior Notice :
Reqrd Rsp Desc :
No response required
Subject :
Posted Maintenance Events for 09/11/2026 - 09/17/2026
TSP :
078444247
Post Date/Time :
09/09/2026 02:23:00 PM
Notice Effective Date/Time :
09/11/2026 09:00:00 AM
Notice End Date/Time :
09/18/2026 09:00:00 AM
Response Date/Time :
Critical :
Notice Text :
https://reporting.prod.bwpmlp.org/infopost/postings?postingsDocumentId=842066
If you have any questions, please contact your customer service representative.
Notice
Page 1 of 1
09/09/2026 2:23:29 PM
Notice
TSP Name :
Gulf South Pipeline Company, LLC
TSP :
078444247
Category :
Critical/Planned Service Outage
Post Date/Time :
09/09/2026 02:23:00 PM
Notice Type Desc :
Maintenance
Notice Effective Date/Time :
09/11/2026 09:00:00 AM
Notice Stat Desc :
Initiate
Notice End Date/Time :
09/18/2026 09:00:00 AM
Notice ID :
5038688
Response Date/Time :
Prior Notice :
Critical :
Reqrd Rsp Desc :
No response required
Subject :
Posted Maintenance Events for 09/11/2026 - 09/17/2026
Notice Text :
https://reporting.prod.bwpmlp.org/infopost/postings?postingsDocumentId=842066
If you have any questions, please contact your customer service representative.
09/09/2026 2:23:29 PM
Page 1 of 1
Corpus Christi LNG

Quorum Server Maintenance September 10, 2026, 10:15PM to September 11, 2026, 12:00AM

SEV 1/5
Informational

Pre-screen severity 1 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Facility: Corpus Christi LNG
Notice ID: 1987
Notice Type: Computer System Status
Status: Active
Title: Quorum Server Maintenance September 10, 2026, 10:15PM to September 11, 2026, 12:00AM
Effective Date/Time: 2026-09-09T13:54:00
End Date/Time: 2026-10-31T00:00:00
Posted: 2026-09-09T13:56:03.047
Note: Effective/End Date above is the posting's overall coverage window, NOT necessarily one continuous outage -- see Notice Text and/or the embedded image below for the actual per-job schedule.

Notice Text:
To provide you with greater support and service, the Quorum Production Team will be applying the Microsoft monthly server patch. As a result of this maintenance, the system may be unavailable:   Thursday, September 10, 2026, 10:15PM – Friday, September 11, 2026, 12:00AM (CST)   Please note that changes made to the Customer Activities Website during this outage may not take effect. We apologize for any inconvenience this may cause you.   If you have any questions, please contact Customer Services at 713-375-5900 or email Cheniere.CTPL@Cheniere.com .
Mountain Valley Pipeline

EQT Midstream Measurement Software Maintenance 09-11-2026

SEV 1/5
Informational

Pre-screen severity 1 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Pipeline: Mountain Valley Pipeline
Notice ID: 138070
Notice Type: OTHER
Subject: EQT Midstream Measurement Software Maintenance 09-11-2026
Posted: Sep 9, 2026
Effective: Sep 9, 2026
End: Dec 30, 2026
Transco

Pipeline Conditions

SEV 1/5
Informational

Pre-screen severity 1 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Pipeline: Transco
Notice: Pipeline Conditions
Posted: 09/09/2026 10:41:54 CDT
Notice ID: 17255214

TRANSCONTINENTAL GAS PIPE LINE COMPANY, LLC

Critical:
 Y

Notice Eff Date:
 09/09/2026

Notice Eff Time:
 10:41:54 CDT

Notice End Date:
 

Notice End Time:
 

Notice ID:
 17255214

Notice Stat Desc:
 Supersede

Notice Type Desc:
 Oper Alert

Post Date:
 09/09/2026

Post Time:
 10:41:54 CDT

Prior Notice:
 17255191

Reqrd Rsp Desc:
 No response required

Rsp Date:
 

Rsp Time:
 

TSP:
 007933021

TSP Name:
 TRANSCONTINENTAL GAS PIPE LINE COMPANY, LLC

Notice Text: 
Subject: 
Pipeline Conditions
Effective Date: 9/9/2026
 
Available Make Up Quantity (Dts)
 
Zone
Shipper
OBA
Incremental
TT03
TT04
TT03
TT63
TT04
TT64
Park
Loan
1
Y
Y
Y
Y
Y
Y
Y
Y
2
Y
Y
Y
Y
Y
Y
Y
Y
3
Y
Y
Y
Y
Y
Y
Y
Y
4
Y
Y
Y
Y
Y
Y
Y
Y
4A
Y
Y
Y
Y
Y
Y
Y
Y
4B
Y
Y
Y
Y
Y
Y
N/A
N/A
5
Y
Y
Y
Y
Y
Y
Y
Y
6
Y
Y
Y
Y
Y
Y
Y
Y
Leidy Line
Y
Y
Y
Y
Y
Y
N/A
N/A
TT03 - Imbalance Payback From TSP (Due To Shipper/OBA)
TT04 - Imbalance Payback To TSP (Due From Shipper/OBA)
TT63 - Prior Month Imbalance Payback From TSP (Due To OBA)
TT64 - Prior Month Imbalance Payback To TSP (Due From OBA)
 
Park/Loan/ISS: For more information regarding availability, any shipper interested in receiving daily park and loan specifics over ICE chat, and prior to scheduling, please call: Chris 713.215.2566 or Collin 281.253.6885.
Excess WSS Injection - Not Available
Excess GSS Injection - Not Available
Excess ESS Injection - 
Available
Excess GSS Withdrawal - Not Available
Excess WSS Withdrawal - Not Available 
Excess ESS Withdrawal -  Not Available 
WSS/GSS/ESS: For more information, please contact your Transportation Services representative
Pool tolerance - .5%
Transco force balances the pool during the ID 3 cycle
For OFO information - Watch Critical Notices
ANR Pipeline (TC Energy)

TC eConnects SYSTEM MAINTENANCE

SEV 1/5
Informational

Pre-screen severity 1 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name ANR Pipeline Company
TSP 006958581
Notice Type Description: Computer System Status

Notice Stat Desc: Initiate

Prior Notice: 

Critical: Y

Reqrd Rsp Desc: No Response Required
Post

Notice Effective

Notice End



Response
Post Date: 09/09/26

09/09/26

09/10/26
Subject: Subject: TC eConnects SYSTEM MAINTENANCE
Author: Author: Giovanna Lococo
Notice Text
The TC eConnects system will undergo maintenance from Wednesday, September 9, 2026, at 10:00 PM CT to Thursday, September 10, 2026, at 2:00 AM CT (approximately four hours). During this maintenance window, the system may experience intermittent outages. 

EDI files will not be sent or received during this period.

 Once the maintenance is complete, customers should close and restart their browsers to get the most updated version of the TC eConnects application.

 For assistance, please call 1-866-581-6487.
Transco

Pipeline Conditions

SEV 1/5
Informational

Pre-screen severity 1 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Pipeline: Transco
Notice: Pipeline Conditions
Posted: 09/09/2026 10:31:19 CDT
Notice ID: 17255191

TRANSCONTINENTAL GAS PIPE LINE COMPANY, LLC

Critical:
 Y

Notice Eff Date:
 09/09/2026

Notice Eff Time:
 10:31:19 CDT

Notice End Date:
 

Notice End Time:
 

Notice ID:
 17255191

Notice Stat Desc:
 Supersede

Notice Type Desc:
 Oper Alert

Post Date:
 09/09/2026

Post Time:
 10:31:19 CDT

Prior Notice:
 17226094

Reqrd Rsp Desc:
 No response required

Rsp Date:
 

Rsp Time:
 

TSP:
 007933021

TSP Name:
 TRANSCONTINENTAL GAS PIPE LINE COMPANY, LLC

Notice Text: 
Subject: 
Pipeline Conditions
Effective Date: 9/9/2026
 
Available Make Up Quantity (Dts)
 
Zone
Shipper
OBA
Incremental
TT03
TT04
TT03
TT63
TT04
TT64
Park
Loan
1
Y
Y
Y
Y
Y
Y
Y
Y
2
Y
Y
Y
Y
Y
Y
Y
Y
3
Y
Y
Y
Y
Y
Y
Y
Y
4
Y
Y
Y
Y
Y
Y
Y
Y
4A
Y
Y
Y
Y
Y
Y
Y
Y
4B
Y
Y
Y
Y
Y
Y
N/A
N/A
5
Y
Y
Y
Y
Y
Y
Y
Y
6
Y
Y
Y
Y
Y
Y
Y
Y
Leidy Line
Y
Y
Y
Y
Y
Y
N/A
N/A
TT03 - Imbalance Payback From TSP (Due To Shipper/OBA)
TT04 - Imbalance Payback To TSP (Due From Shipper/OBA)
TT63 - Prior Month Imbalance Payback From TSP (Due To OBA)
TT64 - Prior Month Imbalance Payback To TSP (Due From OBA)
 
Park/Loan/ISS: For more information regarding availability, any shipper interested in receiving daily park and loan specifics over ICE chat, and prior to scheduling, please call: Chris 713.215.2566 or Collin 281.253.6885.
Excess WSS Injection - Not Available
Excess GSS Injection - 
Available
Excess ESS Injection - Not Available
Excess GSS Withdrawal - Not Available
Excess WSS Withdrawal - Not Available 
Excess ESS Withdrawal -  Not Available 
WSS/GSS/ESS: For more information, please contact your Transportation Services representative
Pool tolerance - .5%
Transco force balances the pool during the ID 3 cycle
For OFO information - Watch Critical Notices
Gulf South Pipeline

Update: Gulf South Pipeline Segmentation

SEV 1/5
Informational

Pre-screen severity 1 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Pipeline: Gulf South Pipeline
Notice ID: 5038686
Notice Type: Customer Services Update
Status: Initiate
Posted: 2026-09-09T09:08:00+00:00
Effective: 2026-09-09T09:10:00+00:00
End: 
Subject: Update: Gulf South Pipeline Segmentation

Gulf South Pipeline Notice 5038686
Source Link
All information here is provided as a service and information is not guaranteed to be accurate. PipeRiv is not responsible for any incorrect information.
TSP Name :
Gulf South Pipeline Company, LLC
Category :
Critical
Notice Type Desc :
Customer Services Update
Notice Stat Desc :
Initiate
Notice ID :
5038686
Prior Notice :
Reqrd Rsp Desc :
No response required
Subject :
Update: Gulf South Pipeline Segmentation
TSP :
078444247
Post Date/Time :
09/09/2026 09:08:00 AM
Notice Effective Date/Time :
09/09/2026 09:10:00 AM
Notice End Date/Time :
Response Date/Time :
Critical :
Notice Text :
Gulf South Pipeline Company, LLC would like to notify customers of an update to the nomination
process for segmentation transactions.
Effective GD September 10, 2026, all segmentation-related nominations must be submitted using
transaction type 84.
If you have any questions, please contact your customer service representative.
Notice
Page 1 of 1
09/09/2026 9:08:54 AM
Notice
TSP Name :
Gulf South Pipeline Company, LLC
TSP :
078444247
Category :
Critical
Post Date/Time :
09/09/2026 09:08:00 AM
Notice Type Desc :
Customer Services Update
Notice Effective Date/Time :
09/09/2026 09:10:00 AM
Notice Stat Desc :
Initiate
Notice End Date/Time :
Notice ID :
5038686
Response Date/Time :
Prior Notice :
Critical :
Reqrd Rsp Desc :
No response required
Subject :
Update: Gulf South Pipeline Segmentation
Notice Text :
Gulf South Pipeline Company, LLC would like to notify customers of an update to the nomination
process for segmentation transactions.
Effective GD September 10, 2026, all segmentation-related nominations must be submitted using
transaction type 84.
If you have any questions, please contact your customer service representative.
09/09/2026 9:08:54 AM
Page 1 of 1
Columbia Gulf Transmission (CGT)

CAPACITY POSTING - TIM for September 10, 2026

UNSCORED
Informational
View original notice text
TSP Name Columbia Gulf Transmission, LLC
TSP 007854581
Notice Type Description: Capacity Constraint

Notice Stat Desc: Initiate

Prior Notice: 

Critical: Y

Reqrd Rsp Desc: No Response Required
Post

Notice Effective

Notice End



Response
Post Date: 09/09/26

09/09/26

10/09/26
Subject: Subject: CAPACITY POSTING - TIM for September 10, 2026
Author: Author: John Whited
Notice Text
COLUMBIA GULF TRANSMISSION, LLC DAILY CAPACITY POSTING 

Columbia Gulf Transmission LLC (CGT) posts projections of anticipated restrictions at least 24 hours prior to the time when nominations are due. These advance forecasts are subject to change based on actual operating conditions. Customers should submit nominations for Timely Cycle to determine whether the service is available under current conditions. 

============================================================================

============================================================================

FORCE MAJEURE / OFO 

No Force majeure is necessary. 

No Operational Flow Order (OFO) is necessary.

============================================================================

============================================================================

Customers are encouraged to monitor scheduled volumes on the Operationally Available Capacity (OAC) screen on Navigates Informational Postings, as nominations may fluctuate based on market conditions.

============================================================================

============================================================================

----------------------------------------------------------------------------

INTERNAL CONSTRAINTS-- Total Capacity (Net Backhaul):

----------------------------------------------------------------------------

StanSEG – Total Capacity

ClemSEG – Total Capacity  

HartSEG – 2,300,000

HampSEG – 2,150,000

CorinSEG – Total Capacity 

BannSEG – Total Capacity

InvrnSEG – Total Capacity 

ShelSEG – Total Capacity

DelhiSEG – Total Capacity

AlexSEG – 2,450,000  

RayneSEG – Total Capacity

WLSEG – Total Capacity

ELSEG – Total Capacity 

EL300SEG – Total Capacity 

HoumaSEG – Total Capacity

----------------------------------------------------------------------------

INTERNAL CONSTRAINTS-- Total Capacity (Net Forwardhaul):

----------------------------------------------------------------------------

StanSEG – Total Capacity 

ClemSEG – Total Capacity

HartSEG – Total Capacity

HampSEG – Total Capacity

CorinSEG – Total Capacity

BannSEG – Total Capacity

InvrnSEG – Total Capacity

ShelSEG – Total Capacity

DelhiSEG - Total Capacity

AlexSEG – Total Capacity

RayneSEG – Total Capacity

WLSEG – Total Capacity

ELSEG – Total Capacity 

EL300SEG – Total Capacity  

HoumaSEG – Total Capacity

               

----------------------------------------------------------------------------

POINT CONSTRAINTS -- Total Capacity:

----------------------------------------------------------------------------

Note: Points listed are controlled by less than meter capacity.

401 - CROSSTEX-GIBSON - 0

445 - TRANSCO / TERREBONNE - 0

481 - SEA ROBIN-ERATH - 0

3194 - TETCO ADAIR CO., KY (Receipts) - Total Capacity (Primary Only)

4051 - LAFAYETTE - ACADIA - Total Capacity (Primary Only)

4078 - SONAT-SHADYSIDE - Total Capacity (Primary Only) 

4098 - BURLINGTON - TERREBONNE - 0

4118 - FLORIDA GAS - Total Capacity (Primary Only)

4123 - EGAN STOR-ACADIA-REC (Receipts and Deliveries) - 370,000 

4137 - CLECO-TECHE - Total Capacity (Primary Only)

4186 - DISCOVERY GAS TRANSMISSION (Deliveries) - Total Capacity (Primary Only)

4197 - MidWestern Pipeline (Deliveries) - 50,000

4204D - GULF SOUTH DELHI Delivery - Total Capacity (Primary Only)

4208R - SOUTHEASTERN SUPPLY HEADER (SESH) - Receipt - 0

4221 - GULF CROSSING - Total Capacity (Primary Only)

4222 - Texas Gas (Isola) - 0

4315 - BROADMORE RD (Receipts) - 775,000 

5112 - NORAM PERRYVILLE Delivery - Total Capacity (Primary Only) 

----------------------------------------------------------------------------

DUE PIPE AND DUE SHIPPER AVAILABILITY:

----------------------------------------------------------------------------

Due Pipe - Available 

Due Shipper - Not Available

============================================================================

============================================================================

PAL & IT BUSINESS

Representatives are available on a daily basis to discuss PAL transactions with customers who have executed master PAL service agreements. (Reminder: Each PAL transaction including rate, term, quantity and point(s) must be provided for and approved on the Appendix A under the Master PAL Agreement). Customers who are interested in PAL transactions for next-day or longer-term park and/or lend transactions or daily discounted IT paths should contact Diana Roberts at 832-758-0900 (ICE droberts6) or Adam Herndon at 832-689-4510 (ICE adherndon) for more information.  

----------------------------------------------------------------------------

AUTO PAL AVAILABILITY:

----------------------------------------------------------------------------

Effective with EVENING Cycle for each Gas Day, Auto Parks/Loans will be limited to +/- 5,000 Dth. Customers are reminded the intent of AutoPAL service is to utilize nominal quantities to resolve pool imbalances that result from upstream or downstream reductions during the cycle. This service should not be used for parking or loaning large quantities.

AutoPAL Parks and Loan Payback - Available

AutoPAL Loans and Unparks - Available

* Denotes a change from previous posting.
Columbia Gas Transmission (TCO)

CAPACITY POSTING - TIM for September 10, 2026

SEV 1/5
Informational

Pre-screen severity 1 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name Columbia Gas Transmission, LLC
TSP 054748041
Notice Type Description: Capacity Constraint

Notice Stat Desc: Initiate

Prior Notice: 

Critical: Y

Reqrd Rsp Desc: No Response Required
Post

Notice Effective

Notice End



Response
Post Date: 09/09/26

09/09/26

10/09/26
Subject: Subject: CAPACITY POSTING - TIM for September 10, 2026
Author: Author: Dillon Schoolcraft
Notice Text
COLUMBIA GAS TRANSMISSION, LLC DAILY CAPACITY POSTING

Columbia Gas Transmission LLC (TCO) posts projections of anticipated market area restrictions at least 24 hours prior to the time when nominations are due. These advance forecasts are subject to change based on actual operating conditions. Customers desiring non-firm services should submit timely nominations to determine whether the service is available under current conditions.

============================================================================

============================================================================

FORCE MAJEURE / STORAGE CRITICAL / TRANSPORT CRITICAL / OFO / RATABLE TAKES

No Force Majeure is necessary.

No Critical Day for Storage is necessary.

No Critical Day for Transport is necessary.

No Operational Flow Order (OFO) is necessary.

Ratable Takes are not required in any Market Areas; however, power customers should request non-ratable takes by submitting a burn profile through TCeConnects.

============================================================================

============================================================================

PIPELINE RECEIPTS, DELIVERIES, INTERNAL CONSTRAINTS, AND DISPLACEMENT AVAILABILITY

For receipts, deliveries, and internal constraints not specifically listed below, please refer to ebb.tceconnects.com/Info Post/Capacity/Operationally Available for information on available capacity at each receipt and delivery point and ebb.tceconnects.com/Info Post/Capacity/Est Op Avail Cap - Internal Constraint for available non-firm capacity at each internal constraint.

Columbia may, from time to time, have displacement capacity available at various receipt/delivery points. Displacement nominations are scheduled based on operational availability up to an approved amount not to exceed the scheduled volumes in the physical direction of flow of the meter. Please contact your Customer Services, Marketing, or O&L Representative for availability at points not listed on this notice.

============================================================================

============================================================================

----------------------------------------------------------------------------

POINT CONSTRAINTS-- Non-Firm Available Capacity:

---------------------------------------------------------------------------- 

633863 - NFG Hartzfelt Mountain - 11,000

636978 - Pine Glen - 0

637095 - MTN GATHERING-HOMER CITY - 0 Total Capacity

637887 - Exotic – Oblinski - 0

640203 - Wagoner Line K - 25,000

640296 - CLINGERMAN - 0

640297 - Range - Sharp - 0

640496 - Range - Day - 0 

640564 - Amwell – 0

640616 - Anadarko Midstream Beech Creek - 0 

642452 - CMG Majorsville - 0

642569 - Mojo - 0

642831 - Range Mills - 0

642838 - Strabane - 0

642854 - Kryptonite - 0

740178 - Fairfield - REX - 75,000

743064 - NEXUS MR06 - 75,000

743365 - Quarry Road - 25,000

736626 - DPL CENTERVILLE - 10,000

737067 - Darby Plant - 75,000

821590 - THOMAS COFFMAN INC YOUNG - 0 

821917 - A&W-Gandee - 0 

823621 - MOUNTAIN STATE-GRANT - 0

824017- STERLING DRG FETTTY - 0 

824766 - TECHNOLOGY DEVELOPMENT - FIELDS - 0 

825005 - CENTRAL PACIFIC GROUP SNYDER - 0 

826130 - STERLING DRG HARPER - 0 

828516 - DORAN-RAINES #1 - 0

833097 - BOSWELLS TAVERN (75-007219) - 0 (Receipts)

833097 - BOSWELLS TAVERN (75-007219) - 100,000

834263 - MCKOWN-JB YOAK LEASE - 0 

835078 - RYAN #702 - 0 

839166 - Patton - 0 

840226 - BenGay MM - 0 

840254 - Vandalia - 0 Total Capacity

842446 - Spencer H Line Sales - 0 

842866 - Green Energy Stonewall - 0

843105 - Transco Chantilly - 50,000

B10 - CAMBRIDGE-9 - 20,000

B15 - UNIONVILLE-35 - 10,000

B17 - HIGHLAND-36 - 20,000

B18 - MILFORD-21 - 0

B9 - BROAD RUN-19 - 0 (Receipts)

B9 - BROAD RUN-19 - 0 (Deliveries)

BYBEE - BYBEE - 0 (Deliveries)

C10 - PLEASANT - 0

C14 - WAYNESBURG - 20,000 

C15 - UNIONTOWN-35 - 0

C16 - DELMONT-36 - 0 (Receipts)

C16 - DELMONT-36 - 0 (Deliveries)

C22 - EAGLE-25 - 0

C23 - PENNSBURG-23 - 0

C41 - TEXAS EASTERN TETCON - 100,000

C45 - Marietta - 0

C9 - HOOKER-5 - 50,000

* CNR06 - CHK Hubball/Horse Ck/NYE - * Total Capacity (Eff. ID1 Cycle 9/9/2026)

E13 - EMPORIA, VA-34 - 0

E17 - MARTINS CREEK - 21 - 0 (Receipts)

E17 - MARTINS CREEK - 21 - 15,000 (Deliveries)

E2 - ROCKVILLE-30 - 0

E3 - DOWNINGTOWN-29 - 0

E9 - YNG WOMANS CK-RENOVO - 0

MVPWB - MVP Columbia WB - 0 (Receipts)

MVPWB - MVP Columbia WB - 0 (Deliveries)

----------------------------------------------------------------------------

DELIVERY INTERNAL CONSTRAINTS-- Non-Firm Available Capacity:

----------------------------------------------------------------------------

ARTEMAS - Artemas MA25 - 0

BICKBOSW - Bickers MA33 - No Restriction 

CERELANH - Lanham East MA19 - 0 

CERELANW - Lanham West MA19 - 0

* CEREWEST - Ceredo West MA19 - * 0

CORNHART - Corning East MA20 - 0

CRAWNORT - Crawford North MA8 - 0

CSLOSTRI - Lost River CS MA30 - No Restriction

DELMONSO - Delmont South MA36 - 10,000

DOWNEAST - Downingtown East MA24 - 25,000

GRENCSTL - Greencastle MA25 - No Restriction

HELLHANO - Hellertown MA22 - 0

HIGHLAND - Highland MA38 - 10,000

HOPEWELL - Hopewell MA33 - No Restriction

INDEGLAS - Corning West MA20 - 5,548

KAEAST - KA East MA17 - 0

LANPKA - Lanham PKA MA19 - 0

LEACHSEG - Leach MA19 - No Restriction

LOUDOUN - Loudoun MA28 - No Restriction

LOUISA - Louisa MA33 - No Restriction 

MA1SEG - Pavonia to Toledo - 10,000 

MA3SEG - Lima MA3 - 10,000 

MA6SEG - Dayton MA6 – 20,000

MA7SEG - Sandusky MA7 - 60,000 

NORTKENT - Northern Kentucky OA6 - No Restriction

PTJRWARW - Wagoner East MA21 - No Restriction

RUTLEDGE - Rutledge North MA28 - 50,000

SENECA - Seneca MA30 - No Restriction

----------------------------------------------------------------------------

RECEIPT INTERNAL CONSTRAINTS-- Non-Firm Available Capacity:

----------------------------------------------------------------------------

A03LINEH - Cobb Line H MA18 - No Restriction

A03LOW - Cobb Northwest MA18 - No Restriction

A03NORTH - Cobb Northeast MA40 - No Restriction

A03SOUTH - Cobb South MA18 - No Restriction

ADALSMIF - Smithfield to Adaline MA35 - 0

ALLIAREC - Alliance Receipts MA4 - 20,000

BOLDMAN - Boldman MA16 - 0

* CHSTKENO - Line P North MA16 - * 25,000 (Eff. ID1 Cycle 9/9/2026)

CLENWAYN - Clendenin to Waynesburg MA35 - 0

COBBA03 - Cobb CS MA18 - No Restriction

CRAWSOUT - Crawford South MA8 - No Restriction

DELMRENO - Delmont MA36 - No Restriction

DOWNWEST - Downingtown West MA24 - 0

EASTON - Easton MA21 - 0

GRANHAML - KA High MA19 - 25,000

HANCOCK - Hancock MA20 - 0

KA1SCBYB - KA1 Station Camp MA13 - 5,500

KAWEST - KA West MA17 - 0

LEBANON - Lebanon MA6 - 50,000 

LONEOAKA - Lone Oak A MA41 - 0

LONEOAKB - Lone Oak B MA41 - 0 

LXPSEG - LXPSEG MA41 - 0

MAYTHUFF - KA Low MA16 - 0 

MXPSEG - MXPSEG MA42 - 0

RUTSOUTH - Rutledge South MA28 - 0 

SHERWODA - Sherwood A MA42 - 0

SHERWODB - Sherwood B MA42 - 100,000 

SMITHFLD - Smithfield MA35 - 0

TANNDELM - Line 1711 MA35 - 0

WALGROVE - Walgrove MA18 - No Restriction

WAYNESNO - Waynesburg North MA35 - 0

 

----------------------------------------------------------------------------

DISPLACEMENT AVAILABILITY-- Non-Firm Available Capacity:

----------------------------------------------------------------------------

843067 - Cornwell - 100,000 

C14 - WAYNESBURG - 30,000

C22 - EAGLE-25 - 25,000

C23 - PENNSBURG-23 - 0

C4 - TETCO LEBANON-6 - 0

E2 - ROCKVILLE-30 - 0

LOUDOUN - LOUDOUN LNG - 0

----------------------------------------------------------------------------

TRANSFER METERS-- Non-Firm Available Capacity:

----------------------------------------------------------------------------

TMBOSWLL - TM Boswells Tavern MA33 - 500,000

TMBRDRUN - TM Broad Run MA19 - 500,000

TMCEREDO - TM Ceredo MA19 - 500,000

TMCHANTY - TM Chantilly MA30 - 500,000

TMEAGLE - TM Eagle MA25 - 500,000

TMLEACH - TM Leach MA19 - 500,000

TMLOSTRI - TM Lost River MA30 - 500,000

TMLOUDN - TM Loudoun MA30 - 500,000

TMLXP - TM LXP MA41 - 500,000

TMMXP - TM MXP MA42 - 500,000

----------------------------------------------------------------------------

LOGICAL METERS-- Non-Firm Available Capacity:

----------------------------------------------------------------------------

MLAPLGRV – Mainline Apple Grove - 500,000

MLCRWFRD - Mainline Crawford - 500,000

MLDRYCRE - Mainline Dry Creek - 500,000

MLEAGLE - Mainline Eagle - 500,000

MLLEACH - Mainline Leach - 500,000

MLLOUDOU - Mainline Loudoun - 500,000

MLLXPMAJ - Mainline LXP Majorsville - 500,000

MLNEWALB - Mainline New Albany - 500,000 

MLPETERS - Mainline Petersburg - 500,000

MLSDRCRK - Mainline Saunders Creek - 500,000

----------------------------------------------------------------------------

DUE PIPE AND DUE SHIPPER AVAILABILITY:

----------------------------------------------------------------------------

OP AREA 01 - Due Pipe - 0, Due Shipper - No Restriction

OP AREA 02 - Due Pipe - 0, Due Shipper - No Restriction

OP AREA 03 - Due Pipe - 0, Due Shipper - No Restriction

OP AREA 04 - Due Pipe - 0, Due Shipper - No Restriction 

OP AREA 05 - Due Pipe - 0, Due Shipper - No Restriction

OP AREA 06 - Due Pipe - 0, Due Shipper - No Restriction

OP AREA 07 - Due Pipe - 0, Due Shipper - No Restriction

OP AREA 08 - Due Pipe - 0, Due Shipper - No Restriction 

OP AREA 10 - Due Pipe - 0, Due Shipper - No Restriction

============================================================================

============================================================================

PAL & IT BUSINESS

Representatives are available daily to discuss PAL transactions with customers who have executed Master PAL Agreements. (Reminder: Each PAL transaction including rate, term, quantity and point(s) must be provided for and approved on the Appendix A under the Master PAL Agreement).Customers who are interested in discounted PAL transactions for next-day or long-term park and/or lend transactions or daily discounted IT paths should contact Diana Roberts at 832-320-5454 (ICE droberts6) or Adam Herndon at 832-689-4510 (ICE adherndon) for more information.

AUTO PAL AVAILABILITY

Effective with EVENING Cycle for each Gas Day, Auto Parks/Loans will be limited to +/-5,000 Dth.Customers are reminded the intent of AutoPAL service is to utilize nominal quantities to resolve pool imbalances that result from upstream or downstream reductions during the cycle.This service should not be used for parking or loaning large quantities.

The following services are eligible for Auto Park/Loan Paybacks and Auto Loan/Park Withdrawals:

IPP

SPP

A01 - Kenova

A02 - Flat Top

A03 - Cobb

A04 - Alexander 

A05 - Delmont 

A06 - McClellandtown

A08 - Crawford

A09 - York 

A10 - Dungannon 

A11 - Binghamton

A12 - Mountaineer Xpress

* Denotes a change from previous posting
Kern River Gas Transmission

Kern River - Line Pack Has Returned to Normal

UNSCORED
Informational
View original notice text
TSP Name: KERN RIVER GAS TRANSMISSION COMPANY
TSP DUNS: 621617372
Notice Identifier: 20260449
Prior Notice Identifier: 20260448
Notice Type:  Pipe Cond
Notice Status: 3
Posting Date: 09/04/2026 07:24
Notice Effective Date: 09/04/2026 07:24
Notice End Date: 09/05/2026 07:24
Subject: Kern River - Line Pack Has Returned to Normal

Notice Text:
Services Portal > Informational Postings > Notices > Critical Skip to main content // // Menu Informational Postings Informational Postings Capacity Operationally Available Unsubscribed Capacity Allocation Log Gas Quality Gas Quality Report Gas Quality Methodology Gas Quality Tariff Provisions Biomethane Operating Policy Mojave Gas Quality Interconnect Party Gas Quality Index of Customers Locations Pooling Locations Notices Critical Non-Critical Planned Service Outage Request to Purchase Releasable Capacity Waste Heat Capacity Release Indices Posted Imbalances Regulatory Standards of Conduct Affiliate Names & Addresses Affiliate Tariff Waivers Chief Compliance Officer Employee Transfers Implementation Procedures Information Disclosure Job Titles & Descriptions Potential Mergers Shared Facilities Voluntary Consent Tariff Title Sheet/Section Table of Contents Preliminary Statement Map Currently Effective Rates Rate Schedules General Terms and Conditions Form of Service Agreement Entire Tariff Sheet/Section Index Transactional Reporting Firm Interruptible Capacity Release Maps System Map High Desert Lateral Wyoming Receipts Nevada Deliveries California Deliveries Utah Deliveries Downloads Search Customer Activities Site Map Customer Activities Nominations Nomination Confirmation Scheduled Quantity -Scheduled Quantity for Shipper -Scheduled Quantity for Operator -View Scheduling Results Flowing Gas Pre-determined Allocation Allocation -Shipper Imbalance -Allocation for Operator Imbalance -TSA Imbalance History -OBA Imbalance History -Shipper Imbalance Measurement -Measurement Information Netting and Trading -Net Imbal -Auth to Post Imbal -Post Imbal Dwnld -Imbal Trd Invoicing Invoice Payment Remittance Statement of Account Negotiated Rate Details Park and Loan Imbalance Rate Case Reports Capacity Release Offers Bids Awards Pre-approved Bidders List Recall Reput Contracts Agreement Request Contract Maintenance Pooling Contracts Transportation Sales Support -Contact Manager -Fuel and L&U Matrix -Hist Fuel and L&U Rates -Capacity Release Log -Contact Us -Notices -Tariff -Rapids Tips & Tricks Rapids Setup -New Customer Setup Form -Rapids Installation -Firewall Settings Informational Postings Site Map Transportation Sales News Announcements Presentations Customer Information Agreements and Forms FERC 809/NAESB 3.0 Info Miscellaneous Info Contact Us Contact List //PRN 15119 KevinH Refactor how the menu works, apply IE PDF preview overlay fix (function($){ $(document).ready(function(){ $('.accordion').each(function(index,value){ var parent = $(value).parent(); var parentId = index; if (!!parent.attr('id')) parentId = parent.attr('id').split('-')[2]; $(value).parent().attr('id','acc-parent-' + parentId); $(value).find('> .accordion-toggle' ).attr('data-target','#acc-body-' + index); $(value).find('> .accordion-body').attr('data-parent','#acc-parent-' + parentId).attr('href','#acc-body-' + index); }); $('.nav .accordion-toggle').on('click', function(event){ var target = $(event.target), parent = target.parent().parent(), parentId = parent.attr('id'); $('[data-parent*="#' + parentId + '"]').each(function(index,value){ if ( $(value).hasClass('in') ) { $(value).collapse('toggle'); } }); $('[href="' + target.attr('data-target') + '"]').collapse('toggle'); if (target.hasClass('collapsed')) { parent.find('.collapsed').removeClass('collapsed'); parent.find('.in').prev().addClass('collapsed'); } else { parent.find('.collapsed').removeClass('collapsed'); parent.find('.in').prev().addClass('collapsed'); target.addClass('collapsed'); } return false; }); if (window.navigator.userAgent.indexOf("MSIE ") > 0 || !!navigator.userAgent.match(/Trident.*rv\:11\./) && ($('.objectPDF').length > 0) ) { $('#navdttg').addClass('ie-pdf-fix'); $('.nav > .accordion').each(function(index,value){ $(value).append(' '); }); $('.nav > .accordion > .accordion-toggle').on('click', function (event) { var target = $(event.target); $('.ie-accordion-fix').removeClass('ie-accordion-fix'); if (target.hasClass('collapsed')) { $('.ie-accordion-fix').removeClass('ie-accordion-fix'); target.parent().addClass('ie-accordion-fix'); } else $('.ie-accordion-fix').removeClass('ie-accordion-fix'); }); function adjustHeight(event) { $('.ie-accordion-fix').height(function(){ return parseInt($('.ie-accordion-fix > .accordion-body').height()) + 20; }); $('html').animate({ scrollTop: 1 },20); } $('.accordion-toggle').on('click', function (event) { $('.ie-accordion-fix').off('shown'); $('.ie-accordion-fix .accordion').off('shown'); $('.ie-accordion-fix').on('shown', adjustHeight); $('.ie-accordion-fix .accordion').on('shown', adjustHeight); }); } }); })(jQuery); Launch Rapids A critical error has occurred. Please check the Event Viewer for further details. ©2026 Kern River Gas Transmission Company. All rights reserved.
Northwest Pipeline

Sumas Meter Upgrade Part 2 - Maintenance Complete

SEV 1/5
Informational

Pre-screen severity 1 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Pipeline: Northwest Pipeline
Notice: Sumas Meter Upgrade Part 2 - Maintenance Complete
Notice ID: 33015

Capacity

Operationally Available
Unsubscribed

Gas Quality

Gas Quality
Gas Quality Tariff Provisions
Gas Quality Sampling Procedures
 Gas Quality Resolution Report
RNG Operating Policy

Index of Customers

Locations

Notices

Critical
Non-Critical
Planned Service Outage
Request to Purchase Releasable Capacity
Waste Heat

Posted Imbalances

Regulatory

FERC Watch
Proposed Tariff Filings

Standards of Conduct

Affiliate Names & Addresses
Affiliate Tariff Waivers
Chief Compliance Officer
Employee Transfers
Implementation Procedures
Information Disclosure
Job Titles & Descriptions
Potential Mergers
Shared Facilities
Voluntary Consent

Tariff

Title Sheet/Section
Table Of Contents
Preliminary Statement
Map
Currently Effective Rates
Rate Schedules
General Terms and Conditions
Form Of Service Agreement
 Entire Tariff
Sheet/Section Index

Transactional Reporting

Capacity Release
Firm
Interruptible

Capacity Release Indices

TSP Capacity Offering

Maintenance Schedule

Commercial Contacts

Agreements/Forms

Portal History

Other

Downloads

Search

Search - Tariff
Search - Rate Schedules
Search - General Terms
Search - Form of Service Agreement
Search - Entire Portal

Customer Activities

Site Map

Northwest Pipeline LLC Notice Detail

Print

Northwest Pipeline LLC

NOTICE # 26-175

Sumas Meter Upgrade Part 2 - Maintenance Complete

 posted on
 
Sep 8 2026 1:45PM

TSP Name: Northwest Pipeline LLC TSP: 67977322

Critical: Y
Notice Stat Desc: SUPERSEDE
Notice Type Desc: MAINTENANCE
Post D/T: 09/08/2026 1:40 PM MCT
Notice Eff D/T: 09/08/2026 1:40 PM MCT
Notice End D/T: 
Reqrd Rsp Desc: No response required
Rsp D/T: 

Notice ID: 26-175
Prior Notice: 26-162
Subject: Sumas Meter Upgrade Part 2 - Maintenance Complete

Notice Text:

Northwest Pipeline would like to inform its customers that the 
Sumas Meter Upgrade Part 2 outage posted on Northwest’s website 
from Gas Day September 02, 2026, through Gas Day September 09, 
2026, and referenced in Notice #26-162 will be completed by the 
end of Gas Day September 08, 2026. 
Northwest will begin accepting nominations up to the design of 
1,409,000 Dth/d southbound through the Sumas CS (located at MP 
1484.48 in Whatcom County, Washington) effective for the Timely 
cycle for Gas Day September 09, 2026. This notice will also 
formally end the current deficiency period at the Sumas CS 
referenced in Notice #26-171. 
Please reference the Maintenance Schedule tab at 
www.northwest.williams.com for more information.
If you have any questions, please call your Commercial Services 
Representative or the hotline at 713-215-6301.
El Paso Natural Gas (EPGD)

[MAINTENANCE] TGP SUMMER MAINTENANCE MTG 9-22-2026

UNSCORED
Informational
View original notice text
Pipeline: El Paso Natural Gas (EPGD)
Notice Type: MAINTENANCE
Subject: TGP SUMMER MAINTENANCE MTG 9-22-2026
Posted: 09/08/2026 6:49:30AM
Effective: 09/08/2026 6:49:30AM
End Date: 09/09/2026 9:00:00AM

TSP/TSP Name:  1939164-TENNESSEE GAS PIPELINE Critical: Y
Notice Type Desc (1):  MAINTENANCE Notice Type Desc (2):  MAINTENANCE
Notice Eff Date/Time:  09/08/2026 6:49:30AM Notice End Date/Time:  09/09/2026 9:00:00am
Post Date/Time:  9/8/2026 6:49:30 AM Notice ID: 404060
Reqrd Rsp:  1 Rsp Date/Time:  9/8/2026 12:00:00 AM
Notice Stat Desc:  INITIATE Prior Notice: 
Subject:  TGP SUMMER MAINTENANCE MTG 9-22-2026
Notice Text:
TGP's 2026 SUMMER MAINTENANCE TEAMS MEETING 9-22-2026
Tennessee Gas Pipeline Company, LLC (“Tennessee”) will be hosting its next 2026 TEAMS Summer Maintenance meeting to provide customers and other interested parties an overview of Tennessee's upcoming Summer Scheduled Maintenance for the remaining days of September and all of October and November 2026 today, Tuesday, September 22, 2026, from 1:30 PM CST to 2:30 PM CST via TEAMS only.  Additionally, there will be a review of upcoming scheduled maintenance on the Stagecoach, Arlington and Twin Tier systems.  There will be a question and answer segment immediately following.
Please see TEAMS info below:
TGP Summer Maintenance and Outages TEAMS Meeting
 
Join on your computer, mobile app or room device
________________________________________________________________________________
Microsoft Teams meeting
Join: https://teams.microsoft.com/meet/23579493131869?p=w4N7s4IHBI1GQNbITK
Meeting ID: 235 794 931 318 69
Passcode: Vg6AB2AN
Need help | System reference
Dial in by phone
+1 346-410-0970,,694003306# United States, Houston
Find a local number
Phone conference ID: 694 003 306#
For organizers: Meeting options | Reset dial-in PIN
________________________________________________________________________________
Texas Eastern Transmission (TETCO)

09/08/2026- Lebanon Compressor Station Unplanned Outage -- COMPLETE

SEV 1/5
Informational

Pre-screen severity 1 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name: Texas Eastern Transmission, LP
Subject: Lebanon Compressor Station Unplanned Outage -- COMPLETE
Notice Type: Capacity Constraint
Critical Notice Description: Critical notice
Notice Status Description: Supersede
Notice Effective Date: 09/08/2026
Notice End Date: 12/07/2026
Posting Date: 09/08/2026
Notice Identifier: 182691
Prior Notice Identifier: 182224
Required Response Indicator Description: No response required

Notice Text:
Texas Eastern has completed the previously posted Lebanon compressor station (Lebanon) unplanned outage and the compressor station has been returned to normal operations.
As a reminder, for Gas Day September 10, 2026, upper 24" capacities will be lowered due to planned posted outages.
Please refer to the TE Major Outage Overview for further information.
Effective immediately, all restrictions associated with this outage have been lifted.
Please contact your Operations Account Representative if you have any questions.
Tuscarora Gas Transmission

TCPLUS System Maintenance

SEV 1/5
Informational

Pre-screen severity 1 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name: Tuscarora Gas Transmission Company
Notice ID: 717
TSP: 808168645
Notice Type: Computer Stat
Notice Status: Initiate
Posting Date/Time: 09/08/2026 09:18
Notice Eff Date: 09/08/2026
Notice Eff Time: 09:25
Notice End Date: 09/09/2026
Notice End Time: 08:59
Critical: No
Required Response: No response required

Subject: TCPLUS System Maintenance

Message Text:
A scheduled system outage required for maintenance will begin Tuesday, September 8, 2026 at 10:00 PM CST. Maintenance should be completed by Wednesday, September 9, 2026 at 12:00 AM CST. During this time TCPLUS system will be unavailable. For assistance please call 1-866-581-6487.
North Baja Pipeline

TCPLUS System Maintenance

SEV 1/5
Informational

Pre-screen severity 1 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name: North Baja Pipeline, LLC
Notice ID: 729
TSP: 030353283
Notice Type: Computer Stat
Notice Status: Initiate
Posting Date/Time: 09/08/2026 09:30
Notice Eff Date: 09/08/2026
Notice Eff Time: 09:35
Notice End Date: 09/09/2026
Notice End Time: 08:59
Critical: No
Required Response: No response required

Subject: TCPLUS System Maintenance

Message Text:
A scheduled system outage required for maintenance will begin Tuesday, September 8, 2026 at 10:00 PM CST. Maintenance should be completed by Wednesday, September 9, 2026 at 12:00 AM CST. During this time TCPLUS system will be unavailable. For assistance please call 1-866-581-6487.
Gas Transmission Northwest

TCPLUS System Maintenance

SEV 1/5
Informational

Pre-screen severity 1 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name: Gas Transmission Northwest LLC
Notice ID: 1634
TSP: 006912885
Notice Type: Computer Stat
Notice Status: Initiate
Posting Date/Time: 09/08/2026 09:20
Notice Eff Date: 09/08/2026
Notice Eff Time: 09:25
Notice End Date: 09/09/2026
Notice End Time: 08:59
Critical: No
Required Response: No response required

Subject: TCPLUS System Maintenance

Message Text:
A scheduled system outage required for maintenance will begin Tuesday, September 8, 2026 at 10:00 PM CST. Maintenance should be completed by Wednesday, September 9, 2026 at 12:00 AM CST. During this time TCPLUS system will be unavailable. For assistance please call 1-866-581-6487.
Great Lakes Gas Transmission

TCPLUS System Maintenance

SEV 1/5
Informational

Pre-screen severity 1 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name: Great Lakes Gas Transmission Limited Partnership
Notice ID: 1227
TSP: 046077343
Notice Type: Computer Stat
Notice Status: Initiate
Posting Date/Time: 09/08/2026 09:20
Notice Eff Date: 09/08/2026
Notice Eff Time: 09:25
Notice End Date: 09/09/2026
Notice End Time: 08:59
Critical: No
Required Response: No response required

Subject: TCPLUS System Maintenance

Message Text:
A scheduled system outage required for maintenance will begin Tuesday, September 8, 2026 at 10:00 PM CST. Maintenance should be completed by Wednesday, September 9, 2026 at 12:00 AM CST. During this time TCPLUS system will be unavailable. For assistance please call 1-866-581-6487.
Tuscarora Gas Transmission

HIGHER BTU GAS on Tuscarora (Posted: 9/8/26)

SEV 1/5
Informational

Pre-screen severity 1 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name: Tuscarora Gas Transmission Company
Notice ID: 716
TSP: 808168645
Notice Type: Gas Qual
Notice Status: Initiate
Posting Date/Time: 09/08/2026 08:52
Notice Eff Date: 09/08/2026
Notice Eff Time: 08:55
Notice End Date: 09/11/2026
Notice End Time: 08:59
Critical: Yes
Required Response: No response required

Subject: HIGHER BTU GAS on Tuscarora (Posted: 9/8/26)

Message Text:
Higher BTU Gas on Tuscarora GTN is expecting to receive higher BTU gas (peaking at 1079 BTU) which will flow through to Tuscarora. The higher BTU range will be as follows: Tuscarora Higher BTU Gas Projected Arrival Date Start Higher BTU Gas Projected Arrival Date End Tracy 01 9/9/26 7:04 AM 9/10/26 10:44 AM Tracy CC 9/9/26 7:04 AM 9/10/26 10:44 AM Barrick 9/9/26 7:04 AM 9/10/26 10:44 AM *Times are in PST Please direct any questions to your Account Coordinator, Customer Service Representative, or the Nominations and Scheduling hotline @ 888-750-6275.
Gas Transmission Northwest

HIGHER BTU GAS on GTN (Posted: 9/8/26)

SEV 1/5
Informational

Pre-screen severity 1 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name: Gas Transmission Northwest LLC
Notice ID: 1633
TSP: 006912885
Notice Type: Gas Qual
Notice Status: Initiate
Posting Date/Time: 09/08/2026 08:48
Notice Eff Date: 09/08/2026
Notice Eff Time: 08:50
Notice End Date: 09/11/2026
Notice End Time: 08:59
Critical: Yes
Required Response: No response required

Subject: HIGHER BTU GAS on GTN (Posted: 9/8/26)

Message Text:
Higher BTU Gas on GTN GTN is expecting to receive higher BTU gas (peaking at 1079 BTU) at its Kingsgate interconnect with Foothills B.C. System. The higher BTU range will be as follows: GTN Location Higher BTU Gas Projected Arrival Date Start Higher BTU Gas Projected Arrival Date End Kingsgate 9/6/26 6:20 PM 9/7/26 10:00 PM Rathdrum 9/6/26 10:53 PM 9/8/26 2:33 AM Spokane 9/6/26 11:37 PM 9/8/26 3:17 AM Palouse 9/7/26 2:48 AM 9/8/26 6:28 AM Stanfield 9/7/26 7:54 AM 9/8/26 11:34 AM Calpine 9/7/26 8:13 AM 9/8/26 11:53 AM South Hermiston 9/7/26 8:46 AM 9/8/26 12:26 PM Coyote Springs Lateral 9/7/26 9:34 AM 9/8/26 1:14 PM Bend 9/7/26 6:59 PM 9/8/26 10:39 PM Medford Lateral 9/8/26 4:32 AM 9/9/26 8:12 AM Tuscarora 9/8/26 5:21 AM 9/9/26 9:01 AM Malin/PG&E 9/8/26 5:21 AM 9/9/26 9:01 AM *Times are in PST Please direct any questions to your Account Coordinator, Customer Service Representative, or the Nominations and Scheduling hotline @ 888-750-6275.
ANR Pipeline (TC Energy)

LIFTED: CAPACITY REDUCTION Michigan Leg South - St. John Eastbound

SEV 1/5
Informational

Pre-screen severity 1 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name ANR Pipeline Company
TSP 006958581
Notice Type Description: Maintenance

Notice Stat Desc: Supersede

Prior Notice: 26210024

Critical: Y

Reqrd Rsp Desc: No Response Required
Post

Notice Effective

Notice End



Response
Post Date: 09/08/26

09/08/26

09/10/26
Subject: Subject: LIFTED: CAPACITY REDUCTION Michigan Leg South - St. John Eastbound
Author: Author: T0000106
Notice Text
Effective immediately, ANR has completed the maintenance at St. John Eastbound (LOC #FPSTJNEB) in the Michigan Leg South area and capacity will be reinstated to 1,325 MMcf/d.

Please direct any questions to your Account Coordinator, Customer Service Representative, or the Nominations and Scheduling hotline @ 800-827-5267
Columbia Gulf Transmission (CGT)

CAPACITY POSTING - TIM for September 9, 2026

UNSCORED
Informational
View original notice text
TSP Name Columbia Gulf Transmission, LLC
TSP 007854581
Notice Type Description: Capacity Constraint

Notice Stat Desc: Initiate

Prior Notice: 

Critical: Y

Reqrd Rsp Desc: No Response Required
Post

Notice Effective

Notice End



Response
Post Date: 09/08/26

09/08/26

10/08/26
Subject: Subject: CAPACITY POSTING - TIM for September 9, 2026
Author: Author: John Whited
Notice Text
COLUMBIA GULF TRANSMISSION, LLC DAILY CAPACITY POSTING 

Columbia Gulf Transmission LLC (CGT) posts projections of anticipated restrictions at least 24 hours prior to the time when nominations are due. These advance forecasts are subject to change based on actual operating conditions. Customers should submit nominations for Timely Cycle to determine whether the service is available under current conditions. 

============================================================================

============================================================================

FORCE MAJEURE / OFO 

No Force majeure is necessary. 

No Operational Flow Order (OFO) is necessary.

============================================================================

============================================================================

Customers are encouraged to monitor scheduled volumes on the Operationally Available Capacity (OAC) screen on Navigates Informational Postings, as nominations may fluctuate based on market conditions.

============================================================================

============================================================================

----------------------------------------------------------------------------

INTERNAL CONSTRAINTS-- Total Capacity (Net Backhaul):

----------------------------------------------------------------------------

StanSEG – Total Capacity

ClemSEG – Total Capacity  

HartSEG – * 2,300,000

HampSEG – * 2,150,000

CorinSEG – Total Capacity 

BannSEG – * Total Capacity

InvrnSEG – Total Capacity 

ShelSEG – Total Capacity

DelhiSEG – Total Capacity

AlexSEG – * 2,450,000  

RayneSEG – Total Capacity

WLSEG – Total Capacity

ELSEG – Total Capacity 

EL300SEG – Total Capacity 

HoumaSEG – Total Capacity

----------------------------------------------------------------------------

INTERNAL CONSTRAINTS-- Total Capacity (Net Forwardhaul):

----------------------------------------------------------------------------

StanSEG – Total Capacity 

ClemSEG – Total Capacity

HartSEG – Total Capacity

HampSEG – Total Capacity

CorinSEG – Total Capacity

BannSEG – Total Capacity

InvrnSEG – Total Capacity

ShelSEG – Total Capacity

DelhiSEG - Total Capacity

AlexSEG – Total Capacity

RayneSEG – Total Capacity

WLSEG – Total Capacity

ELSEG – Total Capacity 

EL300SEG – Total Capacity  

HoumaSEG – Total Capacity

               

----------------------------------------------------------------------------

POINT CONSTRAINTS -- Total Capacity:

----------------------------------------------------------------------------

Note: Points listed are controlled by less than meter capacity.

401 - CROSSTEX-GIBSON - 0

445 - TRANSCO / TERREBONNE - 0

481 - SEA ROBIN-ERATH - 0

3194 - TETCO ADAIR CO., KY (Receipts) - Total Capacity (Primary Only)

4051 - LAFAYETTE - ACADIA - Total Capacity (Primary Only)

4078 - SONAT-SHADYSIDE - Total Capacity (Primary Only) 

4098 - BURLINGTON - TERREBONNE - 0

4118 - FLORIDA GAS - Total Capacity (Primary Only)

4123 - EGAN STOR-ACADIA-REC (Receipts and Deliveries) - 370,000 

4137 - CLECO-TECHE - Total Capacity (Primary Only)

4186 - DISCOVERY GAS TRANSMISSION (Deliveries) - Total Capacity (Primary Only)

4197 - MidWestern Pipeline (Deliveries) - 50,000

4204D - GULF SOUTH DELHI Delivery - Total Capacity (Primary Only)

4208R - SOUTHEASTERN SUPPLY HEADER (SESH) - Receipt - 0

4221 - GULF CROSSING - Total Capacity (Primary Only)

4222 - Texas Gas (Isola) - 0

4315 - BROADMORE RD (Receipts) - 775,000 

5112 - NORAM PERRYVILLE Delivery - Total Capacity (Primary Only) 

----------------------------------------------------------------------------

DUE PIPE AND DUE SHIPPER AVAILABILITY:

----------------------------------------------------------------------------

Due Pipe - Available 

Due Shipper - Not Available

============================================================================

============================================================================

PAL & IT BUSINESS

Representatives are available on a daily basis to discuss PAL transactions with customers who have executed master PAL service agreements. (Reminder: Each PAL transaction including rate, term, quantity and point(s) must be provided for and approved on the Appendix A under the Master PAL Agreement). Customers who are interested in PAL transactions for next-day or longer-term park and/or lend transactions or daily discounted IT paths should contact Diana Roberts at 832-758-0900 (ICE droberts6) or Adam Herndon at 832-689-4510 (ICE adherndon) for more information.  

----------------------------------------------------------------------------

AUTO PAL AVAILABILITY:

----------------------------------------------------------------------------

Effective with EVENING Cycle for each Gas Day, Auto Parks/Loans will be limited to +/- 5,000 Dth. Customers are reminded the intent of AutoPAL service is to utilize nominal quantities to resolve pool imbalances that result from upstream or downstream reductions during the cycle. This service should not be used for parking or loaning large quantities.

AutoPAL Parks and Loan Payback - Available

AutoPAL Loans and Unparks - Available

* Denotes a change from previous posting.
Columbia Gas Transmission (TCO)

LIFTED: Critical Day for Storage Injections: Eff. ID1 Tuesday, September 8, 2026

SEV 1/5
Informational

Pre-screen severity 1 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name Columbia Gas Transmission, LLC
TSP 054748041
Notice Type Description: Storage

Notice Stat Desc: Supersede

Prior Notice: 26239009

Critical: Y

Reqrd Rsp Desc: No Response Required
Post

Notice Effective

Notice End



Response
Post Date: 09/08/26

09/08/26

10/08/26
Subject: Subject: LIFTED: Critical Day for Storage Injections: Eff. ID1 Tuesday, September 8, 2026
Author: Author: Dillon Schoolcraft
Notice Text
LIFTED: Critical Day for Storage Injections: Eff. ID1 Tuesday, September 8, 2026

Columbia Gas Transmission, LLC (TCO) shippers are advised that based on forecasted supply and markets, TCO is hereby lifting the Critical Day for Storage Injections effective intraday for Intraday Gas Day Tuesday, September 8, 2026. Although the Critical Day is lifted, TCO reserves the right to issue Critical Days as future conditions warrant.  

Please contact your Customer Services Representative if you have any questions. 

***Previous Posting***

Columbia Gas Transmission, LLC (TCO) notifies customers that Critical Days for storage injections are necessary effective Gas Day Saturday, September 5, 2026, and continuing until further notice.

 

Based on forecasted supply, reduced market demand, above-average storage levels, and firm storage injection requirements, Transporter projects that all available storage injection capacity will be required to meet firm service obligations. Transporter projects no availability of interruptible storage injection services. Due pipe nominations will be scheduled to zero. Storage withdrawal services are not impacted by this notice.

 

The following daily penalties will apply:

 

FSS MDIQ

 

-Shipper shall pay a penalty of $5.00 per Dth for all quantities injected in excess of 110% of the applicable Contract MDIQ.

 

FSS SCQ

 

-Shipper shall pay a penalty of $5.00 per Dth for all quantities injected in excess of its SCQ.

 

The following monthly penalties will apply:

 

FSS MMIQ

 

-Shipper shall pay a penalty of $5.00 per Dth for all quantities injected in excess of 105% of the applicable MMIQ.

 

This notice describes the events leading up to the declaration of a Critical Day, as required in General Terms and Conditions, Section 19.7 of Columbia Gas Transmission's FERC Gas Tariff.

 

Please contact your Customer Services Representative with any questions.
Tennessee Gas Pipeline (TGP)

TGP SUMMER MAINTENANCE MTG 9-22-2026

SEV 1/5
Informational

Pre-screen severity 1 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Interstate
Other
Midstream
Informational Postings
Capacity
Gas Electric Coordination
Gas Quality
Index of Customers
Locations
Notices
Posted Imbalances
Regulatory
Standards of Conduct
Tariff
Transactional Reporting
Info Lookup
Other
Downloads
Search
Customer Activities
Site Map
	
	
NOTICE DETAIL
	
PDF
TEXT
Return To Results
TSP/TSP Name:  1939164-TENNESSEE GAS PIPELINE	Critical: Y
Notice Type Desc (1):  MAINTENANCE	Notice Type Desc (2):  MAINTENANCE
Notice Eff Date/Time:  09/08/2026 6:49:30AM	Notice End Date/Time:  09/09/2026 9:00:00am
Post Date/Time:  9/8/2026 6:49:30 AM	Notice ID: 404060
Reqrd Rsp:  1	Rsp Date/Time:  9/8/2026 12:00:00 AM
Notice Stat Desc:  INITIATE	Prior Notice: 
Subject:  TGP SUMMER MAINTENANCE MTG 9-22-2026
Notice Text:

TGP's 2026 SUMMER MAINTENANCE TEAMS MEETING 9-22-2026

Tennessee Gas Pipeline Company, LLC (“Tennessee”) will be hosting its next 2026 TEAMS Summer Maintenance meeting to provide customers and other interested parties an overview of Tennessee's upcoming Summer Scheduled Maintenance for the remaining days of September and all of October and November 2026 today, Tuesday, September 22, 2026, from 1:30 PM CST to 2:30 PM CST via TEAMS only.  Additionally, there will be a review of upcoming scheduled maintenance on the Stagecoach, Arlington and Twin Tier systems.  There will be a question and answer segment immediately following.

Please see TEAMS info below:

TGP Summer Maintenance and Outages TEAMS Meeting

 

Join on your computer, mobile app or room device

________________________________________________________________________________

Microsoft Teams meeting

Join: https://teams.microsoft.com/meet/23579493131869?p=w4N7s4IHBI1GQNbITK

Meeting ID: 235 794 931 318 69

Passcode: Vg6AB2AN

Need help | System reference

Dial in by phone

+1 346-410-0970,,694003306# United States, Houston

Find a local number

Phone conference ID: 694 003 306#

For organizers: Meeting options | Reset dial-in PIN

________________________________________________________________________________

 

..
MountainWest (multi-pipeline)

[MountainWest Pipeline (MWP)] [MOUNTAINWEST PIPELINE OFO] MOUNTAINWEST PIPELINE OFO

SEV 1/5
Informational

Pre-screen severity 1 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Pipeline: MountainWest Pipeline (MWP)
Notice ID: 39131
Notice Type: MOUNTAINWEST PIPELINE OFO
Subject: MOUNTAINWEST PIPELINE OFO
Posted: 09/03/2026 12:30 PM
Effective: 09/05/2026 09:00 AM
End Date: 39131

MountainWest Pipeline Customer Access myQuorum Login Access Agreements User Access Requests Transmission Services MountainWest Pipeline Informational Postings Capacity Gas Quality Index of Customers Locations Notices Critical Non-Critical Planned Services Outages Request to Purchase Releasable Capacity Waste Heat Posted Imbalances Standards of Conduct Tariff Transactional Reporting Other Downloads Search Customer Activites Site Map System Operations MWP Home MountainWest Overthrust Pipeline White River Hub System Wide Notices - MountainWest Pipeline TSP Name: MountainWest Pipeline, LLC TSP: 092027077 Critical: Y Notice Type Desc Post Date/Time Notice Eff Date/Time Notice ID Subject Rsp Date/Time Notice Stat Prior Notice Reqrd Rsp OFO 09/03/2026 12:30 PM 09/05/2026 09:00 AM 39131 MOUNTAINWEST PIPELINE OFO 1 5 All listed times are CCT MOUNTAINWEST PIPELINE OFO Beginning Gas Day September 5, 2026 Timely cycle lasting through Gas Day September 8, 2026: MountainWest Pipeline, LLC (MWP) is experiencing low line pack. MWP is issuing an OFO pursuant to MWP’s tariff sections 12.13 and 12.14. No imbalance nominations at MAP 9996 will be allowed. All receipt and delivery points will be held to nomination, and cuts will be implemented as necessary for any point not on rate. MWP’s tariff can be found at https://www.mwpipe.com/Tariff/MWP If you have any questions, please contact your MWP Marketing or Contract Services Representative or Scheduling on the Customer Service Hotline at 801-584-6034. MountainWest Pipeline Home | Contact Us | Code of Business Conduct & Ethics | Site Map © 2009–2026 MountainWest Pipeline
Algonquin Gas Transmission

09/03/2026- AGT Pipeline Conditions for 09/04/2026

UNSCORED
Informational
View original notice text
TSP Name: Algonquin Gas Transmission, LLC
Subject: AGT Pipeline Conditions for 09/04/2026
Notice Type: Capacity Constraint
Critical Notice Description: Critical notice
Notice Status Description: Initiate
Notice Effective Date: 09/04/2026
Notice End Date: 09/05/2026
Posting Date: 09/03/2026
Notice Identifier: 182527
Required Response Indicator Description: No response required

For Gas Day September 4, 2026, Algonquin Gas Transmission (AGT) has approved and scheduled nominations at each pipeline segment and meter station up to AGT's operational capacity. The following locations have been restricted due to requested nominations exceeding AGT's operational capacity:
Restricted Locations
Scheduled and Sealed
Priority % Restricted
Notes
Stony Point
100%
100%
42%
Cromwell
100%
100%
53%
Burrillville
100%
100%
31%
Weymouth
100%
100%
98%
Iroquois Deliveries
100%
100%
51%
Iroquois Receipts
100%
100%
52%
Hanover West
100%
100%
21%
Mendon Receipts
100%
100%
100%
100%
81%
Lincoln Receipts
100%
100%
31%
Lincoln Deliveries
Yes
G System
100%
100%
34%
C System
Yes
Centerville-Transco Receipts (1)
100%
100%
11%
I-8 West to East
Yes
No-Notice Restrictions
---
OFO / Imbalance Notice
System Wide OFO
---
Customer Specific OFO
---
Meter Specific OFO
---
Customer Specific Hourly OFO
---
Imbalances Warnings
Stay Balanced
FERC Order 698
Yes
Systemwide Notes:
(1) AGT has scheduled Transco Centerville receipts to the design meter capacity of 222,526 Dth/d.
AGT requests that customers/point operators on AGT be aware of the impact non-ratable hourly takes from the system may have in causing delivery pressures reaching lower than desired levels.
AGT's system is not designed to sustain delivery pressures above contract levels while making non-ratable/accelerated deliveries above scheduled quantities for more than 6 consecutive hours, to be followed by flows below scheduled quantity for the balance of any 24-hour period. If customers/point operators don't manage hourly takes from the system, 1) delivery pressures will be impacted and /or 2) AGT may be required to impose further restrictions or courses of action in order to maintain the operational integrity of the system.
AGT may be required to issue system specific, meter specific and/or hourly OFO's pursuant to General Terms and Conditions Section 26.7(d) to impose further restrictions in order to maintain the operational integrity of the system.
Customers are advised that capacity may become available as the nomination and confirmation process continues throughout the day.
Please contact your Operations Account Representative should you have any questions.
Tuscarora Gas Transmission

HIGHER BTU GAS on Tuscarora (Posted: 9/4/26)

UNSCORED
Informational
View original notice text
Notice Category: Critical
Notice Type: Gas Qual
Notice Status: Initiate
Posting Date/Time: 09/04/2026 12:47
Notice Eff Date/Time: 09/04/2026 13:48

Subject: HIGHER BTU GAS on Tuscarora (Posted: 9/4/26)
Gas Transmission Northwest

HIGHER BTU GAS on GTN (Posted: 9/4/26)

UNSCORED
Informational
View original notice text
Notice Category: Critical
Notice Type: Gas Qual
Notice Status: Initiate
Posting Date/Time: 09/04/2026 12:44
Notice Eff Date/Time: 09/04/2026 13:46

Subject: HIGHER BTU GAS on GTN (Posted: 9/4/26)
Algonquin Gas Transmission

09/04/2026- AGT Pipeline Conditions for 09/05/2026

UNSCORED
Informational
View original notice text
TSP Name: Algonquin Gas Transmission, LLC
Subject: AGT Pipeline Conditions for 09/05/2026
Notice Type: Capacity Constraint
Critical Notice Description: Critical notice
Notice Status Description: Initiate
Notice Effective Date: 09/05/2026
Notice End Date: 09/06/2026
Posting Date: 09/04/2026
Notice Identifier: 182576
Required Response Indicator Description: No response required

For Gas Day September 5, 2026, Algonquin Gas Transmission (AGT) has approved and scheduled nominations at each pipeline segment and meter station up to AGT's operational capacity. The following locations have been restricted due to requested nominations exceeding AGT's operational capacity:
Restricted Locations
Scheduled and Sealed
Priority % Restricted
Notes
Stony Point
100%
100%
55%
Cromwell
100%
100%
51%
Burrillville
100%
100%
26%
Weymouth
100%
100%
99%
Iroquois Deliveries
100%
100%
56%
Iroquois Receipts
100%
100%
41%
Hanover West
100%
100%
21%
Mendon Receipts
100%
100%
100%
100%
82%
Lincoln Receipts
100%
100%
31%
Lincoln Deliveries
Yes
G System
100%
100%
29%
C System
Yes
Centerville-Transco Receipts (1)
100%
100%
I-8 West to East
Yes
No-Notice Restrictions
---
OFO / Imbalance Notice
System Wide OFO
No DS - System Wide issued 9/05/26. 500 Dth / 5% Tolerance
Customer Specific OFO
---
Meter Specific OFO
---
Customer Specific Hourly OFO
---
Imbalances Warnings
---
FERC Order 698
Yes
Systemwide Notes:
(1) AGT has scheduled Transco Centerville receipts to the design meter capacity of 222,526 Dth/d.
AGT requests that customers/point operators on AGT be aware of the impact non-ratable hourly takes from the system may have in causing delivery pressures reaching lower than desired levels.
AGT's system is not designed to sustain delivery pressures above contract levels while making non-ratable/accelerated deliveries above scheduled quantities for more than 6 consecutive hours, to be followed by flows below scheduled quantity for the balance of any 24-hour period. If customers/point operators don't manage hourly takes from the system, 1) delivery pressures will be impacted and /or 2) AGT may be required to impose further restrictions or courses of action in order to maintain the operational integrity of the system.
AGT may be required to issue system specific, meter specific and/or hourly OFO's pursuant to General Terms and Conditions Section 26.7(d) to impose further restrictions in order to maintain the operational integrity of the system.
Customers are advised that capacity may become available as the nomination and confirmation process continues throughout the day.
Please contact your Operations Account Representative should you have any questions.
East Tennessee Natural Gas

09/05/2026- ETNG Pipeline Conditions for 09/06/2026

UNSCORED
Informational
View original notice text
TSP Name: East Tennessee Natural Gas, LLC
Subject: ETNG Pipeline Conditions for 09/06/2026
Notice Type: Capacity Constraint
Critical Notice Description: Critical notice
Notice Status Description: Initiate
Notice Effective Date: 09/06/2026
Notice End Date: 09/07/2026
Posting Date: 09/05/2026
Notice Identifier: 182599
Required Response Indicator Description: No response required

For Gas Day September 6, 2026, East Tennessee Natural Gas (ETNG) has approved and scheduled nominations at each pipeline segment and meter station up to ETNG's operational capacity. The following locations have been restricted due to requested nominations exceeding ETNG's operational capacity:
Restricted Locations
Scheduled and Sealed
Priority % Restricted
Notes
Deliveries To Texas Eastern
100%
100%
100%
100%
Topside South
100%
100%
82%
Fordtown West - Westbound
Yes
Flatwoods East - Westbound
Yes
OFO / Imbalance Notice
OFO
---
Customer Specific OFO
---
Hourly Customer Specific OFO
---
Action Alert
---
Imbalances Warnings
Stay Balanced
Systemwide Notes:
ETNG requires any imbalance payback be coordinated through your Operations Account Representative.
If necessary, ETNG will utilize any provision of its tariff to ensure system integrity including the issuance of customer specific or system wide OFOs.
Effective October 1, 2025, MR 59200 - SNG Whitfield will be restricted to 0 Dth / d until further notice due to SNG pressures being lower than ETNG's typical operating pressure. Also, effective October 1, 2025, MR 59311 - SNG Bradley will be limited to its meter capacity of 31,000 Dth/d.
Customers are advised that capacity may become available as the nomination and confirmation process continues throughout the day.
Please contact your Operations Account Representative should you have any questions.
El Paso Natural Gas (EPNG)

[OPERATIONAL FLOW ORDER] SOC Lifted - System Wide DRAFT

SEV 1/5
Informational

Pre-screen severity 1 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Pipeline: El Paso Natural Gas (EPNG)
Notice Type: OPERATIONAL FLOW ORDER
Subject: SOC Lifted - System Wide DRAFT
Posted: 09/06/2026 8:08:36AM
Effective: 09/06/2026 8:08:36AM
End Date: 09/07/2026 9:00:00AM

TSP/TSP Name:  8001703-EL PASO NATURAL GAS CO. L.L.C. Critical: Y
Notice Type Desc (1):  OPERATIONAL FLOW ORDER Notice Type Desc (2):  OFO
Notice Eff Date/Time:  09/06/2026 8:08:36AM Notice End Date/Time:  09/07/2026 9:00:00am
Post Date/Time:  9/6/2026 8:08:36 AM Notice ID: 629557
Reqrd Rsp:  5 Rsp Date/Time: 
Notice Stat Desc:  SUPERSEDE Prior Notice:  629548
Subject:  SOC Lifted - System Wide DRAFT
Notice Text:
SOC Lifted – System Wide DRAFT Condition
 
The Strained Operating Condition (“SOC”) for a Draft condition issued on September 5, 2026, (Critical Notice No. 629548) will be lifted effective Gas Day September 6, 2026.  As such the SOC was in effect for Gas Day September 5, 2026, only.
 
Customer response has been sufficient to increase EPNG's linepack to acceptable levels.
 
Delivery point operators are encouraged to continue to deliver gas according to their scheduled quantities.
 
For scheduling questions, please call your scheduling representative at (800) 238-3764.
 
For operational and capacity questions, please call Russ Pyeatt at (719) 520-3729, Dan English at (719) 520-4722, Morgan McCasland at (719) 520-4339, or John Althoff at (719) 667-7750.
  
For media inquiries, please contact media relations at newsroom@kindermorgan.com.
North Baja Pipeline

North Baja Transition to TC eConnects – Nominations & Scheduling Training

SEV 1/5
Informational

Pre-screen severity 1 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Notice Category: Non-Critical
Notice Type: Cust Svc
Notice Status: Initiate
Posting Date/Time: 09/02/2026 11:30
Notice Eff Date/Time: 09/02/2026 11:30

Subject: North Baja Transition to TC eConnects – Nominations & Scheduling Training
Algonquin Gas Transmission

09/01/2026- AGT Pipeline Conditions for 09/02/2026

UNSCORED
Informational
View original notice text
TSP Name: Algonquin Gas Transmission, LLC
Subject: AGT Pipeline Conditions for 09/02/2026
Notice Type: Capacity Constraint
Critical Notice Description: Critical notice
Notice Status Description: Initiate
Notice Effective Date: 09/02/2026
Notice End Date: 09/03/2026
Posting Date: 09/01/2026
Notice Identifier: 182464
Required Response Indicator Description: No response required

For Gas Day September 2, 2026, Algonquin Gas Transmission (AGT) has approved and scheduled nominations at each pipeline segment and meter station up to AGT's operational capacity. The following locations have been restricted due to requested nominations exceeding AGT's operational capacity:
Restricted Locations
Scheduled and Sealed
Priority % Restricted
Notes
Stony Point
100%
100%
60%
Cromwell
100%
100%
57%
Burrillville
100%
100%
36%
Weymouth
100%
100%
98%
Iroquois Deliveries
100%
100%
59%
Iroquois Receipts
100%
100%
46%
Hanover West
100%
100%
21%
Mendon Receipts
100%
100%
100%
100%
84%
Lincoln Receipts
100%
100%
33%
Lincoln Deliveries
Yes
G System
100%
100%
33%
C System
Yes
Centerville-Transco Receipts (1)
100%
100%
I-8 West to East
Yes
No-Notice Restrictions
---
OFO / Imbalance Notice
System Wide OFO
---
Customer Specific OFO
---
Meter Specific OFO
---
Customer Specific Hourly OFO
---
Imbalances Warnings
Stay Balanced
FERC Order 698
Yes
Systemwide Notes:
(1) AGT has scheduled Transco Centerville receipts to the design meter capacity of 222,526 Dth/d.
AGT requests that customers/point operators on AGT be aware of the impact non-ratable hourly takes from the system may have in causing delivery pressures reaching lower than desired levels.
AGT's system is not designed to sustain delivery pressures above contract levels while making non-ratable/accelerated deliveries above scheduled quantities for more than 6 consecutive hours, to be followed by flows below scheduled quantity for the balance of any 24-hour period. If customers/point operators don't manage hourly takes from the system, 1) delivery pressures will be impacted and /or 2) AGT may be required to impose further restrictions or courses of action in order to maintain the operational integrity of the system.
AGT may be required to issue system specific, meter specific and/or hourly OFO's pursuant to General Terms and Conditions Section 26.7(d) to impose further restrictions in order to maintain the operational integrity of the system.
Customers are advised that capacity may become available as the nomination and confirmation process continues throughout the day.
Please contact your Operations Account Representative should you have any questions.
MountainWest (multi-pipeline)

[MountainWest Pipeline (MWP)] [2026 CLAY BASIN FALL INJECTION TEST] 2026 CLAY BASIN FALL INJECTION TEST

SEV 1/5
Informational

Pre-screen severity 1 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Pipeline: MountainWest Pipeline (MWP)
Notice ID: 39151
Notice Type: 2026 CLAY BASIN FALL INJECTION TEST
Subject: 2026 CLAY BASIN FALL INJECTION TEST
Posted: 09/04/2026 03:40 PM
Effective: 09/15/2026 09:00 AM
End Date: 39151

MountainWest Pipeline Customer Access myQuorum Login Access Agreements User Access Requests Transmission Services MountainWest Pipeline Informational Postings Capacity Gas Quality Index of Customers Locations Notices Critical Non-Critical Planned Services Outages Request to Purchase Releasable Capacity Waste Heat Posted Imbalances Standards of Conduct Tariff Transactional Reporting Other Downloads Search Customer Activites Site Map System Operations MWP Home MountainWest Overthrust Pipeline White River Hub System Wide Notices - MountainWest Pipeline TSP Name: MountainWest Pipeline, LLC TSP: 092027077 Critical: Y Notice Type Desc Post Date/Time Notice Eff Date/Time Notice ID Subject Rsp Date/Time Notice Stat Prior Notice Reqrd Rsp STORAGE/OFO/PLND OUTAGE 09/04/2026 03:40 PM 09/15/2026 09:00 AM 39151 2026 CLAY BASIN FALL INJECTION TEST 1 5 All listed times are CCT 2026 CLAY BASIN FALL INJECTION TEST MountainWest Pipeline (MWP) has scheduled the annual Clay Basin Injection Test for gas days October 6 through October 14, 2026. Listed below is the schedule for this year’s test (All references are for gas days): • September 15 MWP will issue Operational Flow Orders to all FSS customers indicating their required injection volumes. • October 3 through October 5: Reservoir conditioning begins. No withdrawals allowed. • October 6: The reservoir will be conditioned at a constant injection rate of 78,750 Dth for 24 hours. • October 7: Reservoir test at a constant injection rate of 105,000 Dth for 24 hours. • October 8 through October 14: Field shut in. Only in-place transfer nominations will be processed. • October 15: Field returns to normal at 8:00 AM. If you have any questions, please contact your MWP Marketing or Contract Services Representative or the Customer Service Hotline at 801-584-6034. MountainWest Pipeline Home | Contact Us | Code of Business Conduct & Ethics | Site Map © 2009–2026 MountainWest Pipeline
North Baja Pipeline

Notice of North Baja TC eConnects System Conversion Filing

SEV 1/5
Informational

Pre-screen severity 1 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Notice Category: Non-Critical
Notice Type: Other
Notice Status: Initiate
Posting Date/Time: 09/01/2026 16:10
Notice Eff Date/Time: 09/01/2026 16:11

Subject: Notice of North Baja TC eConnects System Conversion Filing
Steckman Ridge

09/01/2026- SR Storage Conditions for 9/2/2026

UNSCORED
Informational
View original notice text
TSP Name: Steckman Ridge, LP
Subject: SR Storage Conditions for 9/2/2026
Notice Type: Capacity Constraint
Critical Notice Description: Critical notice
Notice Status Description: Initiate
Notice Effective Date: 09/02/2026
Notice End Date: 09/03/2026
Posting Date: 09/01/2026
Notice Identifier: 182443
Required Response Indicator Description: No response required

Notice Text:
The following restriction will be in place on the Steckman Ridge system for Gas Day September 2, 2026:
Steckman Ridge has restricted a portion of excess injections. No increases in injections will be accepted except to comply with NAESB bump guidelines.
Customers are advised that capacity may become available as the nomination and confirmation process continues throughout the day.
Please contact your Operations Account Representative if you have any questions.
Steckman Ridge

09/02/2026- SR Storage Conditions for 09/03/2026

UNSCORED
Informational
View original notice text
TSP Name: Steckman Ridge, LP
Subject: SR Storage Conditions for 09/03/2026
Notice Type: Capacity Constraint
Critical Notice Description: Critical notice
Notice Status Description: Initiate
Notice Effective Date: 09/03/2026
Notice End Date: 09/04/2026
Posting Date: 09/02/2026
Notice Identifier: 182480
Required Response Indicator Description: No response required

Notice Text:
The following restriction will be in place on the Steckman Ridge system for Gas Day September 3, 2026:
Steckman Ridge has restricted a portion of excess injections. No increases in injections will be accepted except to comply with NAESB bump guidelines.
Customers are advised that capacity may become available as the nomination and confirmation process continues throughout the day.
Please contact your Operations Account Representative if you have any questions.
Steckman Ridge

09/03/2026- SR Storage Conditions for 9/4/2026

UNSCORED
Informational
View original notice text
TSP Name: Steckman Ridge, LP
Subject: SR Storage Conditions for 9/4/2026
Notice Type: Capacity Constraint
Critical Notice Description: Critical notice
Notice Status Description: Initiate
Notice Effective Date: 09/04/2026
Notice End Date: 09/05/2026
Posting Date: 09/03/2026
Notice Identifier: 182525
Required Response Indicator Description: No response required

Notice Text:
The following restriction will be in place on the Steckman Ridge system for Gas Day September 4, 2026:
Steckman Ridge has restricted a portion of excess injections. No increases in injections will be accepted except to comply with NAESB bump guidelines.
Customers are advised that capacity may become available as the nomination and confirmation process continues throughout the day.
Please contact your Operations Account Representative if you have any questions.
Southeast Supply Header

09/01/2026- SESH Pipeline Conditions for 9/2/2026

UNSCORED
Informational
View original notice text
TSP Name: Southeast Supply Header, LLC
Subject: SESH Pipeline Conditions for 9/2/2026
Notice Type: Capacity Constraint
Critical Notice Description: Critical notice
Notice Status Description: Initiate
Notice Effective Date: 09/02/2026
Notice End Date: 09/03/2026
Posting Date: 09/01/2026
Notice Identifier: 182441
Required Response Indicator Description: No response required

For Gas Day September 2, 2026, Southeast Supply Header (SESH) has approved and scheduled nominations at each pipeline segment and meter station up to SESH's operational capacity. The following locations have been restricted due to requested nominations exceeding SESH's operational capacity:
Restricted Locations
Scheduled and Sealed
Priority % Restricted
Notes
Gwinville
Yes
Gwinville East
100%
OFO / Imbalance Notice
OFO
---
Customer Specific OFO
---
Imbalances Warnings
No DP - System Wide
Systemwide Notes:
SESH has limited operational flexibility to manage imbalances. As a result, SESH requires all delivery point operators to keep actual daily takes out of the system equal to or less than scheduled quantities regardless of their cumulative imbalance position unless otherwise coordinated with your operations account representative.
Customers are advised that capacity may become available as the nomination and confirmation process continues throughout the day.
Please contact your Operations Account Representative should you have any questions.
Southeast Supply Header

09/02/2026- SESH Pipeline Conditions for 09/03/2026

UNSCORED
Informational
View original notice text
TSP Name: Southeast Supply Header, LLC
Subject: SESH Pipeline Conditions for 09/03/2026
Notice Type: Capacity Constraint
Critical Notice Description: Critical notice
Notice Status Description: Initiate
Notice Effective Date: 09/03/2026
Notice End Date: 09/04/2026
Posting Date: 09/02/2026
Notice Identifier: 182481
Required Response Indicator Description: No response required

For Gas Day September 3, 2026, Southeast Supply Header (SESH) has approved and scheduled nominations at each pipeline segment and meter station up to SESH's operational capacity. The following locations have been restricted due to requested nominations exceeding SESH's operational capacity:
Restricted Locations
Scheduled and Sealed
Priority % Restricted
Notes
Gwinville
100%
Gwinville East
85%
OFO / Imbalance Notice
OFO
---
Customer Specific OFO
---
Imbalances Warnings
No DP - System Wide
Systemwide Notes:
SESH has limited operational flexibility to manage imbalances. As a result, SESH requires all delivery point operators to keep actual daily takes out of the system equal to or less than scheduled quantities regardless of their cumulative imbalance position unless otherwise coordinated with your operations account representative.
Customers are advised that capacity may become available as the nomination and confirmation process continues throughout the day.
Please contact your Operations Account Representative should you have any questions.
Southeast Supply Header

09/03/2026- SESH Pipeline Conditions for 9/4/2026

UNSCORED
Informational
View original notice text
TSP Name: Southeast Supply Header, LLC
Subject: SESH Pipeline Conditions for 9/4/2026
Notice Type: Capacity Constraint
Critical Notice Description: Critical notice
Notice Status Description: Initiate
Notice Effective Date: 09/04/2026
Notice End Date: 09/05/2026
Posting Date: 09/03/2026
Notice Identifier: 182518
Required Response Indicator Description: No response required

For Gas Day September 4, 2026, Southeast Supply Header (SESH) has approved and scheduled nominations at each pipeline segment and meter station up to SESH's operational capacity. The following locations have been restricted due to requested nominations exceeding SESH's operational capacity:
Restricted Locations
Scheduled and Sealed
Priority % Restricted
Notes
Gwinville
100%
Gwinville East
Yes
OFO / Imbalance Notice
OFO
---
Customer Specific OFO
---
Imbalances Warnings
No DP - System Wide
Systemwide Notes:
SESH has limited operational flexibility to manage imbalances. As a result, SESH requires all delivery point operators to keep actual daily takes out of the system equal to or less than scheduled quantities regardless of their cumulative imbalance position unless otherwise coordinated with your operations account representative.
Customers are advised that capacity may become available as the nomination and confirmation process continues throughout the day.
Please contact your Operations Account Representative should you have any questions.
ANR Pipeline (TC Energy)

MAINTENANCE SCHEDULE for ANR Pipeline

SEV 1/5
Informational

Pre-screen severity 1 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name ANR Pipeline Company
TSP 006958581
Notice Type Description: Planned Service Outage

Notice Stat Desc: Supersede

Prior Notice: 26205012

Critical: Y

Reqrd Rsp Desc: No Response Required
Post

Notice Effective

Notice End



Response
Post Date: 09/04/26

09/04/26

12/01/26
Subject: Subject: MAINTENANCE SCHEDULE for ANR Pipeline
Author: Author: T0000106
Notice Text
ANR Pipeline Maintenance Schedule has been updated as of 9/4/26.

 

Please refer to the Maintenance Schedule found on ANR Informational Postings under Construction and Maintenance. 

 

Please note that the information posted is proposed and subject to change.  

 

Please direct any questions to your Account Coordinator, Customer Service Representative, or the Nominations and Scheduling hotline @ 800-827-5267
Columbia Gulf Transmission (CGT)

COMPLETED: Means Valve Replacement (StanSEG), Effective ID2 for September 4, 2026

SEV 1/5
Informational

Pre-screen severity 1 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name Columbia Gulf Transmission, LLC
TSP 007854581
Notice Type Description: Maintenance

Notice Stat Desc: Supersede

Prior Notice: 26151012

Critical: Y

Reqrd Rsp Desc: No Response Required
Post

Notice Effective

Notice End



Response
Post Date: 09/04/26

09/04/26

10/04/26
Subject: Subject: COMPLETED: Means Valve Replacement (StanSEG), Effective ID2 for September 4, 2026
Author: Author: Tyler King
Notice Text
Columbia Gulf Transmission, LLC (CGT) notifies customers the Means valve replacement maintenance is complete. As a result, the backhaul capacity through StanSEG has been reinstated to Total Capacity effective Intraday 2 Cycle for Gas Day September 4, 2026, and Timely Cycle for Gas Day September 5, 2026. 

Please contact your Customer Services Representative with any questions. 

  

***Previous Posting***





Columbia Gulf Transmission LLC (CGT) notifies customers of upcoming valve replacement in Means, Kentucky beginning on Thursday, August 27, 2026, through Thursday, September 3, 2026. As a result, the backhaul capacity through StanSEG will be reduced to a level between 1,950,000 and 2,200,000 Dth effective Timely Cycle for Gas Day Thursday, August 27, 2026.

CGT anticipates this restriction may result in curtailments to Interruptible, Secondary Firm, and Primary Firm services. Please see the details provided below for more information.

StanSEG

·        Estimated Capacity Setting: 1,950,000 – 2,200,000 Dth

·        Design Capacity: 2,344,656 Dth

·        Posted Percentage: 83-94%

Due to the potential impact to firm service, CGT encourages customers to monitor the scheduled volumes on the Operationally Available Capacity screen on Informational Postings, as nominations can fluctuate based on market conditions. 

Reservation Charge Credits (RCCs) will be determined per the process set forth in the General Terms and Conditions, Section 40 of CGT’s FERC Gas Tariff (Tariff). By means of this notice, CGT is establishing the 7-day Average Usage Quantity to be the period of June 13-19, 2026, pursuant to the provisions in the Tariff. 

Please contact your Customer Services Representative with any questions.
Columbia Gas Transmission (TCO)

Construction and Maintenance Schedule Posting

SEV 1/5
Informational

Pre-screen severity 1 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name Columbia Gas Transmission, LLC
TSP 054748041
Notice Type Description: Maintenance

Notice Stat Desc: Initiate

Prior Notice: 

Critical: Y

Reqrd Rsp Desc: No Response Required
Post

Notice Effective

Notice End



Response
Post Date: 09/04/26

09/04/26

10/04/26
Subject: Subject: Construction and Maintenance Schedule Posting
Author: Author: Jonah Skiles
Notice Text
As a courtesy, Columbia Gas Transmission, LLC (TCO) hereby notifies customers the Construction and Maintenance Schedule posted under "Construction and Maintenance" on the Informational Postings website has been updated. TCO reminds customers to please check the Maintenance Schedule on a regular basis.     

The current schedule has been updated to reflect maintenance activity on the following:

 

*Revised Dates – Hubball Compressor Station Maintenance – September 8, 2026 (Previously Scheduled for September 8-11, 2026)

*Revised Dates – SM80 Pipeline Maintenance west of Saunders Creek – September 10-26, 2026 (Previously Scheduled for September 9-26, 2026)

*Revised Dates – SM102 Pipe Replacement – September 30 - October 7, 2026 (Previously Scheduled for September 30 - October 11, 2026)

*Revised Dates – Summerfield Compressor Station ESD and Maintenance – October 27-28, 2026 (Previously Scheduled for October 2026)

Additionally, the following file(s) can be located on Informational Postings under Construction and Maintenance









Additionally, the following file(s) can be located on Informational Postings under Construction and Maintenance

TCO Construction and Maintenance Schedule 09-04-2026.pdf
Corpus Christi LNG

CTPL AUGUST 2026 Invoices

SEV 1/5
Informational

Pre-screen severity 1 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Facility: Corpus Christi LNG
Notice ID: 1985
Notice Type: Billing and Payments
Status: Active
Title: CTPL AUGUST 2026 Invoices
Effective Date/Time: 2026-09-04T09:49:00
End Date/Time: 2026-12-04T00:00:00
Posted: 2026-09-04T09:50:09.273
Note: Effective/End Date above is the posting's overall coverage window, NOT necessarily one continuous outage -- see Notice Text and/or the embedded image below for the actual per-job schedule.

Notice Text:
Cheniere Creole Trail Pipeline, L.P.’s AUGUST 2026 invoices are now available online.   Customers may view their invoices in MyQuorum. To avoid interest charges, payment of the AUGUST 2026 invoice must be made on or before the 10 th day of receiving this notice. If you have any problems viewing your invoice or if you have any questions, please contact Customer Services at 713-375-5900 or email  Cheniere.CTPL@Cheniere.com .
Kern River Gas Transmission

Kern River - Warning - Line Pack is Trending High

SEV 1/5
Informational

Pre-screen severity 1 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name: KERN RIVER GAS TRANSMISSION COMPANY
TSP DUNS: 621617372
Notice Identifier: 20260448
Prior Notice Identifier:
Notice Type:  Pipe Cond
Notice Status: 3
Posting Date: 09/02/2026 16:16
Notice Effective Date: 09/02/2026 16:16
Notice End Date: 09/17/2026 16:16
Subject: Kern River - Warning - Line Pack is Trending High

Notice Text:
Services Portal > Informational Postings > Notices > Critical Skip to main content // // Menu Informational Postings Informational Postings Capacity Operationally Available Unsubscribed Capacity Allocation Log Gas Quality Gas Quality Report Gas Quality Methodology Gas Quality Tariff Provisions Biomethane Operating Policy Mojave Gas Quality Interconnect Party Gas Quality Index of Customers Locations Pooling Locations Notices Critical Non-Critical Planned Service Outage Request to Purchase Releasable Capacity Waste Heat Capacity Release Indices Posted Imbalances Regulatory Standards of Conduct Affiliate Names & Addresses Affiliate Tariff Waivers Chief Compliance Officer Employee Transfers Implementation Procedures Information Disclosure Job Titles & Descriptions Potential Mergers Shared Facilities Voluntary Consent Tariff Title Sheet/Section Table of Contents Preliminary Statement Map Currently Effective Rates Rate Schedules General Terms and Conditions Form of Service Agreement Entire Tariff Sheet/Section Index Transactional Reporting Firm Interruptible Capacity Release Maps System Map High Desert Lateral Wyoming Receipts Nevada Deliveries California Deliveries Utah Deliveries Downloads Search Customer Activities Site Map Customer Activities Nominations Nomination Confirmation Scheduled Quantity -Scheduled Quantity for Shipper -Scheduled Quantity for Operator -View Scheduling Results Flowing Gas Pre-determined Allocation Allocation -Shipper Imbalance -Allocation for Operator Imbalance -TSA Imbalance History -OBA Imbalance History -Shipper Imbalance Measurement -Measurement Information Netting and Trading -Net Imbal -Auth to Post Imbal -Post Imbal Dwnld -Imbal Trd Invoicing Invoice Payment Remittance Statement of Account Negotiated Rate Details Park and Loan Imbalance Rate Case Reports Capacity Release Offers Bids Awards Pre-approved Bidders List Recall Reput Contracts Agreement Request Contract Maintenance Pooling Contracts Transportation Sales Support -Contact Manager -Fuel and L&U Matrix -Hist Fuel and L&U Rates -Capacity Release Log -Contact Us -Notices -Tariff -Rapids Tips & Tricks Rapids Setup -New Customer Setup Form -Rapids Installation -Firewall Settings Informational Postings Site Map Transportation Sales News Announcements Presentations Customer Information Agreements and Forms FERC 809/NAESB 3.0 Info Miscellaneous Info Contact Us Contact List //PRN 15119 KevinH Refactor how the menu works, apply IE PDF preview overlay fix (function($){ $(document).ready(function(){ $('.accordion').each(function(index,value){ var parent = $(value).parent(); var parentId = index; if (!!parent.attr('id')) parentId = parent.attr('id').split('-')[2]; $(value).parent().attr('id','acc-parent-' + parentId); $(value).find('> .accordion-toggle' ).attr('data-target','#acc-body-' + index); $(value).find('> .accordion-body').attr('data-parent','#acc-parent-' + parentId).attr('href','#acc-body-' + index); }); $('.nav .accordion-toggle').on('click', function(event){ var target = $(event.target), parent = target.parent().parent(), parentId = parent.attr('id'); $('[data-parent*="#' + parentId + '"]').each(function(index,value){ if ( $(value).hasClass('in') ) { $(value).collapse('toggle'); } }); $('[href="' + target.attr('data-target') + '"]').collapse('toggle'); if (target.hasClass('collapsed')) { parent.find('.collapsed').removeClass('collapsed'); parent.find('.in').prev().addClass('collapsed'); } else { parent.find('.collapsed').removeClass('collapsed'); parent.find('.in').prev().addClass('collapsed'); target.addClass('collapsed'); } return false; }); if (window.navigator.userAgent.indexOf("MSIE ") > 0 || !!navigator.userAgent.match(/Trident.*rv\:11\./) && ($('.objectPDF').length > 0) ) { $('#navdttg').addClass('ie-pdf-fix'); $('.nav > .accordion').each(function(index,value){ $(value).append(' '); }); $('.nav > .accordion > .accordion-toggle').on('click', function (event) { var target = $(event.target); $('.ie-accordion-fix').removeClass('ie-accordion-fix'); if (target.hasClass('collapsed')) { $('.ie-accordion-fix').removeClass('ie-accordion-fix'); target.parent().addClass('ie-accordion-fix'); } else $('.ie-accordion-fix').removeClass('ie-accordion-fix'); }); function adjustHeight(event) { $('.ie-accordion-fix').height(function(){ return parseInt($('.ie-accordion-fix > .accordion-body').height()) + 20; }); $('html').animate({ scrollTop: 1 },20); } $('.accordion-toggle').on('click', function (event) { $('.ie-accordion-fix').off('shown'); $('.ie-accordion-fix .accordion').off('shown'); $('.ie-accordion-fix').on('shown', adjustHeight); $('.ie-accordion-fix .accordion').on('shown', adjustHeight); }); } }); })(jQuery); Launch Rapids A critical error has occurred. Please check the Event Viewer for further details. ©2026 Kern River Gas Transmission Company. All rights reserved.
Southern Natural Gas

[OPERATIONAL FLOW ORDER] OFO DAILY CD1 DS219 EFF 9-5 LIFTED 9-8

UNSCORED
Informational
View original notice text
Pipeline: Southern Natural Gas
Notice Type: OPERATIONAL FLOW ORDER
Subject: OFO DAILY CD1 DS219 EFF 9-5 LIFTED 9-8
Posted: 09/04/2026 6:40:20AM
Effective: 09/04/2026 6:40:20AM
End Date: 09/05/2026 9:00:00AM

TSP/TSP Name:  1939164-TENNESSEE GAS PIPELINE Critical: Y
Notice Type Desc (1):  OPERATIONAL FLOW ORDER Notice Type Desc (2):  OFO
Notice Eff Date/Time:  09/04/2026 6:40:20AM Notice End Date/Time:  09/05/2026 9:00:00am
Post Date/Time:  9/4/2026 6:40:20 AM Notice ID: 403974
Reqrd Rsp:  1 Rsp Date/Time:  9/4/2026 12:00:00 AM
Notice Stat Desc:  SUPERSEDE Prior Notice:  403291
Subject:  OFO DAILY CD1 DS219 EFF 9-5 LIFTED 9-8
Notice Text:
OFO DAILY CRITICAL DAY 1 DS OF STA 219 EFFECTIVE 9-5-2026
 
Due to forecasted milder weather with associated lesser demand moving into the Northeast areas of its system, in order to protect the operational integrity of its system, effective for the Gas Day (“GD”) of Saturday, September 5, 2026 Tennessee Gas Pipeline Company, L.L.C. (“Tennessee”) is implementing an OFO Daily Critical Day (“CD”) 1 for all areas East of STA 219 for over-deliveries into the system or under-takes out of the system pursuant to Article X of the General Terms and Conditions of Tennessee's FERC NGA Gas Tariff.  Tennessee is lifting the OFO Daily Critical Day 1 for all areas East of STA 219 effective for the Gas Day of Tuesday, September 8, 2026 and until further notice.
 
This OFO will be effective for LMS-PA, SA contracts acting as balancing parties and LMS-MA Balancing Parties only.
 
Please refer to the table below for the affected areas and dates, and the actions required:
Zone
 
GD 9-4-26
 
GD 9-5-26 through 9-7-2026
 
GD 9-8-26 and until further notice
Zone 0
 
No OFO
 
No OFO
 
No OFO
Zone L
 
Critical Day 1
500 Line Only
(Includes Segments 527, 529, 530 Only)
·         Receipts do not underdeliver
·         Deliveries do not overtake
 
Critical Day 1
500 Line Only
(Includes Segments 527, 529, 530 Only)
·         Receipts do not underdeliver
·         Deliveries do not overtake
 
Critical Day 1
500 Line Only
(Includes Segments 527, 529, 530 Only)
·         Receipts do not underdeliver
·         Deliveries do not overtake
Zone 1
 
Critical Day 1
500 Line Only
(Includes Segments 534, 539 Only)
·         Receipts do not underdeliver
·         Deliveries do not overtake
 
Critical Day 1
500 Line Only
(Includes Segments 534, 539 Only)
·         Receipts do not underdeliver
·         Deliveries do not overtake
 
Critical Day 1
500 Line Only
(Includes Segments 534, 539 Only)
·         Receipts do not underdeliver
·         Deliveries do not overtake
Zone 2
 
No OFO
 
No OFO
 
No OFO
Zone 3
 
No OFO
 
No OFO
 
No OFO
Zone 4
 
No OFO
 
Critical Day 1
All Areas East and North of STA 219 Only
·         Receipts do not overdeliver
·         Deliveries do not undertake
 
No OFO
Zone 5
 
No OFO
 
Critical Day 1
All Areas
·         Receipts do not overdeliver
·         Deliveries do not undertake
 
No OFO
Zone 6
 
No OFO
 
Critical Day 1
All Areas
·         Receipts do not overdeliver
·         Deliveries do not undertake
 
No OFO
CD 1 PENALTY: $5.00 + applicable Regional Daily Spot Price per Dth for quantities in excess of the tolerance
CD 1 TOLERANCE:  Greater of 2% of scheduled quantities or 500 Dth
 
Balancing between OBA points in separate pipeline regions or across meters not located in the OFO area will not be permitted.
 
In the event this OFO is not sufficient to maintain the operational integrity of its system, Tennessee may escalate to calling a Critical Day II, a Balancing Alert, Meter Specific OFO(s) or Hourly OFO(s), or taking any other actions that may be permitted or required by Tennessee's Tariff.  
 
Please contact your Scheduling Representative if you have any questions.
Columbia Gulf Transmission (CGT)

CAPACITY POSTING - TIM for September 5, through September 8, 2026

UNSCORED
Informational
View original notice text
TSP Name Columbia Gulf Transmission, LLC
TSP 007854581
Notice Type Description: Capacity Constraint

Notice Stat Desc: Initiate

Prior Notice: 

Critical: Y

Reqrd Rsp Desc: No Response Required
Post

Notice Effective

Notice End



Response
Post Date: 09/04/26

09/04/26

10/04/26
Subject: Subject: CAPACITY POSTING - TIM for September 5, through September 8, 2026
Author: Author: John Whited
Notice Text
COLUMBIA GULF TRANSMISSION, LLC DAILY CAPACITY POSTING 

Columbia Gulf Transmission LLC (CGT) posts projections of anticipated restrictions at least 24 hours prior to the time when nominations are due. These advance forecasts are subject to change based on actual operating conditions. Customers should submit nominations for Timely Cycle to determine whether the service is available under current conditions. 

============================================================================

============================================================================

FORCE MAJEURE / OFO 

No Force majeure is necessary. 

No Operational Flow Order (OFO) is necessary.

============================================================================

============================================================================

Customers are encouraged to monitor scheduled volumes on the Operationally Available Capacity (OAC) screen on Navigates Informational Postings, as nominations may fluctuate based on market conditions.

============================================================================

============================================================================

----------------------------------------------------------------------------

INTERNAL CONSTRAINTS-- Total Capacity (Net Backhaul):

----------------------------------------------------------------------------

StanSEG – 1,950,000 

ClemSEG – Total Capacity  

HartSEG – Total Capacity

HampSEG – Total Capacity

CorinSEG – Total Capacity 

BannSEG – 2,300,000

InvrnSEG – Total Capacity 

ShelSEG – Total Capacity

DelhiSEG – Total Capacity

AlexSEG – Total Capacity  

RayneSEG – Total Capacity

WLSEG – Total Capacity

ELSEG – Total Capacity 

EL300SEG – Total Capacity 

HoumaSEG – Total Capacity

----------------------------------------------------------------------------

INTERNAL CONSTRAINTS-- Total Capacity (Net Forwardhaul):

----------------------------------------------------------------------------

StanSEG – Total Capacity 

ClemSEG – Total Capacity

HartSEG – Total Capacity

HampSEG – Total Capacity

CorinSEG – Total Capacity

BannSEG – Total Capacity

InvrnSEG – Total Capacity

ShelSEG – Total Capacity

DelhiSEG - Total Capacity

AlexSEG – Total Capacity

RayneSEG – Total Capacity

WLSEG – Total Capacity

ELSEG – Total Capacity 

EL300SEG – Total Capacity  

HoumaSEG – Total Capacity

               

----------------------------------------------------------------------------

POINT CONSTRAINTS -- Total Capacity:

----------------------------------------------------------------------------

Note: Points listed are controlled by less than meter capacity.

401 - CROSSTEX-GIBSON - 0

445 - TRANSCO / TERREBONNE - 0

481 - SEA ROBIN-ERATH - 0

3194 - TETCO ADAIR CO., KY (Receipts) - Total Capacity (Primary Only)

4051 - LAFAYETTE - ACADIA - Total Capacity (Primary Only)

4078 - SONAT-SHADYSIDE - Total Capacity (Primary Only) 

4098 - BURLINGTON - TERREBONNE - 0

4118 - FLORIDA GAS - Total Capacity (Primary Only)

4123 - EGAN STOR-ACADIA-REC (Receipts and Deliveries) - 370,000 

4137 - CLECO-TECHE - Total Capacity (Primary Only)

4186 - DISCOVERY GAS TRANSMISSION (Deliveries) - Total Capacity (Primary Only)

4197 - MidWestern Pipeline (Deliveries) - 50,000

4204D - GULF SOUTH DELHI Delivery - Total Capacity (Primary Only)

4208R - SOUTHEASTERN SUPPLY HEADER (SESH) - Receipt - 0

4221 - GULF CROSSING - Total Capacity (Primary Only)

4222 - Texas Gas (Isola) - 0

4315 - BROADMORE RD (Receipts) - 775,000 

5112 - NORAM PERRYVILLE Delivery - Total Capacity (Primary Only) 

----------------------------------------------------------------------------

DUE PIPE AND DUE SHIPPER AVAILABILITY:

----------------------------------------------------------------------------

Due Pipe - Available 

Due Shipper - Not Available

============================================================================

============================================================================

PAL & IT BUSINESS

Representatives are available on a daily basis to discuss PAL transactions with customers who have executed master PAL service agreements. (Reminder: Each PAL transaction including rate, term, quantity and point(s) must be provided for and approved on the Appendix A under the Master PAL Agreement). Customers who are interested in PAL transactions for next-day or longer-term park and/or lend transactions or daily discounted IT paths should contact Diana Roberts at 832-758-0900 (ICE droberts6) or Adam Herndon at 832-689-4510 (ICE adherndon) for more information.  

----------------------------------------------------------------------------

AUTO PAL AVAILABILITY:

----------------------------------------------------------------------------

Effective with EVENING Cycle for each Gas Day, Auto Parks/Loans will be limited to +/- 5,000 Dth. Customers are reminded the intent of AutoPAL service is to utilize nominal quantities to resolve pool imbalances that result from upstream or downstream reductions during the cycle. This service should not be used for parking or loaning large quantities.

AutoPAL Parks and Loan Payback - Available

AutoPAL Loans and Unparks - Available

* Denotes a change from previous posting.
Algonquin Gas Transmission

09/01/2026- Hanover to Stoney Point Line 30B Valve Section 6 Investigation -- COMPLETE

SEV 1/5
Informational

Pre-screen severity 1 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name: Algonquin Gas Transmission, LLC
Subject: Hanover to Stoney Point Line 30B Valve Section 6 Investigation -- COMPLETE
Notice Type: Capacity Constraint
Critical Notice Description: Critical notice
Notice Status Description: Initiate
Notice Effective Date: 09/01/2026
Notice End Date: 11/30/2026
Posting Date: 09/01/2026
Notice Identifier: 182430
Required Response Indicator Description: No response required

Notice Text:
Algonquin Gas Transmission (AGT) has completed the previously posted HANA-STON L30 VS-06 detailed investigation and the line has returned to normal operations.
Effective immediately, all restrictions associated with this outage have been lifted.
Please contact your Operations Account Representative if you have any questions.
Columbia Gulf Transmission (CGT)

UPDATE: Mainline-200 Pipeline Maintenance (BannSEG)

UNSCORED
Informational
View original notice text
TSP Name Columbia Gulf Transmission, LLC
TSP 007854581
Notice Type Description: Maintenance

Notice Stat Desc: Supersede

Prior Notice: 26151013

Critical: Y

Reqrd Rsp Desc: No Response Required
Post

Notice Effective

Notice End



Response
Post Date: 09/03/26

09/03/26

10/03/26
Subject: Subject: UPDATE: Mainline-200 Pipeline Maintenance (BannSEG)
Author: Author: Dillon Schoolcraft
Notice Text
Columbia Gulf Transmission, LLC (CGT) notifies customers the maintenance on Mainline-200 between the 607 Valve Set and the 608 Valve Set is ongoing. Based on current operating conditions, the maintenance is now tentatively scheduled to continue through Gas Day Wednesday, August 9, 2026. 

Reservation Charge Credits (RCCs) will be determined per the process set forth in the General Terms and Conditions, Section 40 of CGT’s FERC Gas Tariff (Tariff).

Please contact your Customer Services Representative with any questions.

***Previous Posting***

Columbia Gulf Transmission LLC (CGT) notifies customers of upcoming pipeline maintenance on Mainline-200 beginning on Thursday, August 27, 2026, through Sunday, September 6, 2026. As a result, the backhaul capacity through BannSEG will be reduced to a level between 2,300,000 – 2,350,000 Dth effective Timely Cycle for Gas Day Thursday, August 27, 2026. 

CGT anticipates this restriction may result in curtailments to Interruptible, Secondary Firm, and Primary Firm services. Please see the details provided below for more information.

BannSEG

·       Estimated Capacity Setting: 2,300,000 – 2,350,000 Dth 

·       Design Capacity: 2,540,256 Dth

·       Posted Percentage: 91-93%

Due to the potential impact to firm service, CGT encourages customers to monitor the scheduled volumes on the Operationally Available Capacity screen on Informational Postings, as nominations can fluctuate based on market conditions. 

Reservation Charge Credits (RCCs) will be determined per the process set forth in the General Terms and Conditions, Section 40 of CGT’s FERC Gas Tariff (Tariff). By means of this notice, CGT is establishing the 7-day Average Usage Quantity to be the period of June 13-19, 2026, pursuant to the provisions in the Tariff. 

Please contact your Customer Services Representative with any questions.
Tennessee Gas Pipeline (TGP)

TGP Outage Impact Report

SEV 1/5
Informational

Pre-screen severity 1 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Interstate
Other
Midstream
Informational Postings
Capacity
Gas Electric Coordination
Gas Quality
Index of Customers
Locations
Notices
Posted Imbalances
Regulatory
Standards of Conduct
Tariff
Transactional Reporting
Info Lookup
Other
Downloads
Search
Customer Activities
Site Map
	
	
NOTICE DETAIL
	
PDF
TEXT
Return To Results
TSP/TSP Name:  1939164-TENNESSEE GAS PIPELINE	Critical: Y
Notice Type Desc (1):  MAINTENANCE	Notice Type Desc (2):  MAINTENANCE
Notice Eff Date/Time:  09/03/2026 2:43:49PM	Notice End Date/Time:  09/04/2026 9:00:00am
Post Date/Time:  9/3/2026 2:43:49 PM	Notice ID: 403958
Reqrd Rsp:  1	Rsp Date/Time:  9/3/2026 12:00:00 AM
Notice Stat Desc:  INITIATE	Prior Notice: 
Subject:  TGP Outage Impact Report
Notice Text:

 

	

 

	

 

	

 

	

 

	

 

	

 

	

-Primary impact restrictions may be necessary




 

	

 

	

 

	

TGP - Outage Impact Report

	

 

	

 

	

 

	

-Major impact restrictions may be necessary




 

	

 

	

Seven Day Forecast (updated 09/03/26)

	

 

	

 

	

-Minor impact restrictions may be necessary depending on flow conditions




 

	

 

	

 

	

 

	

 

	

-Little to no impact, though minor outages may cause incremental reductions




Station / Seg

	

Est Nominal

Operating Capacity (Thousand Dth)

	

Monday

(9/7)

	

Tuesday

(9/8)

	

Wednesday

(9/9)

	

Thursday

(9/10)

	

Friday

(9/11)

	

Saturday

(9/12)

	

Sunday

(9/13)

	

 

Primary Outage(s) that may Impact Throughput




Est. Operational Capacity (Operational Impact) - Thousand Dth




Station 409 (Donna Line) (segment 490

FH)

	

 

564

	

 

564

	

 

564

	

 

564

	

 

564

	

 

564

	

 

564

	

 

564

	

 




Station 1

(segment 101 BH)

	

 

399

	

 

399

	

207

(192)

	

207

(192)

	

207

(192)

	

207

(192)

	

207

(192)

	

207

(192)

	

MLV 2-2 to MLV 3-2: Anomaly Remediation (9/8/2026 - 9/18/2026)




Station 17

(segment 117 FH)

	

 

1,122

	

1100

(22)

	

1100

(22)

	

1100

(22)

	

1100

(22)

	

1100

(22)

	

1100

(22)

	

1100

(22)

	

MLV 19-1 TO MLV 20-1A: Pipe Replacement (M) (8/6/2026 - 9/18/2026)




Station 25

(segment 125 FH)

	

 

1,078

	

 

1,078

	

 

1,078

	

 

1,078

	

 

1,078

	

 

1,078

	

 

1,078

	

 

1,078

	

 




Station 47

(segment 143 FH)

	

 

1,343

	

 

1,343

	

1045

(298)

	

 

1,343

	

1045

(298)

	

 

1,343

	

 

1,343

	

 

1,343

	

MLV 47-4D to MLV 54-4S: Pig Run - AFD Combo (M) (9/8/2026) MLV 47-4D to MLV 54-4S: Pig Run - EMAT (M) (9/10/2026)




Station 63

(segment 163 FH)

	

 

1,242

	

1117

(125)

	

1117

(125)

	

1117

(125)

	

1117

(125)

	

1117

(125)

	

1117

(125)

	

1117

(125)

	

MLV 54-3 to MLV 106-3: Emergent Repair - CAO (2/26/2026 - 12/31/2026)




Station 823

(segment 823 BH)

	

 

734

	

 

734

	

 

734

	

 

734

	

 

734

	

 

734

	

 

734

	

 

734

	

 




Station 834

(segment 834 BH)

	

 

683

	

670

(13)

	

670

(13)

	

670

(13)

	

670

(13)

	

670

(13)

	

 

683

	

 

683

	

Sta 834: Unit 4A - Replace Lubrication System (9/7/2026 - 9/11/2026)




Station 534 South of Pool (segment 530 BH)

	

 

1,550

	

 

985

(565)

	

 

985

(565)

	

 

985

(565)

	

 

985

(565)

	

 

985

(565)

	

 

985

(565)

	

 

985

(565)

	

MLV 533-2 to MLV 534-2: Pipe Replacement (M) (6/4/2026 - 9/17/2026)




Station 860

(segment 548 BH)

	

 

1,593

	

 

1405

(188)

	

 

1405

(188)

	

 

1405

(188)

	

 

1405

(188)

	

 

1405

(188)

	

 

1405

(188)

	

 

1405

(188)

	

Sta 542: Unit 2A - Emergent Repair (4/7/2026 - 9/30/2026) Sta 542: Unit 3A - Emergent Repair (3/26/2026 - 9/18/2026) Sta 546: Unit 7A - Metal in Oil (7/14/2025 - 9/30/2026)

Sta 555: Unit 1B - Hot Gas Path (8/10/2026 - 9/18/2026)




Station 860 North (Segment 860 BH)

	

 

1,530

	

 

1180

(350)

	

 

1180

(350)

	

 

1180

(350)

	

 

1180

(350)

	

 

1180

(350)

	

 

1180

(350)

	

 

1180

(350)

	

Sta 563: Unit 1A - Emergent Repair (8/28/2026 - 9/18/2026) Sta 860: Unit 1A - Aftercooler Jacket Water Inspection (6/17/2025 -

12/31/2026)




 

Station 110

(segment 187 BH)

(south thru Kentucky)

	

 

 

 

2,685

	

 

 

2424

(261)

	

 

 

2424

(261)

	

 

 

2424

(261)

	

 

 

2424

(261)

	

 

 

2424

(261)

	

 

 

2436

(249)

	

 

 

2441

(244)

	

MLV 104-1 to MLV 105-1: Anomaly Remediation (8/6/2026 - 9/12/2026) MLV 109-4 to MLV 110-4: Pipe Replacement (8/10/2026 - 9/11/2026)

MLV 110-2 to MLV 114-2: CAO - Force Majeure (M) (7/14/2026 - 12/31/2026)

MLV 54-3 to MLV 106-3: Emergent Repair - CAO (2/26/2026 - 12/31/2026) MLV 96-3BR to MLV 96-3BL: Spike Test (7/27/2026 - 9/18/2026)

Sta 106: Unit 1C - Engine Maintenance (8/26/2026 - 9/10/2026) Sta 87: Unit 3D - Power side Overhaul (6/22/2026 - 9/30/2026)




Station 114

(segment 114 BH)

	

 

907

	

 

393

(514)

	

 

393

(514)

	

 

393

(514)

	

 

393

(514)

	

 

393

(514)

	

 

907

	

 

907

	

MLV 117-3 to MLV 118-3: Special Permit Pipe Replacement (8/18/2026 - 9/11/2026)

MLV 119-2 to MLV 119-2A: Special Permit Pipe Replacement (8/18/2026 -

9/11/2026)




Station 204

(Segment 204 BH)

	

 

1,828

	

1700

(128)

	

1695

(133)

	

1700

(128)

	

1695

(133)

	

 

1,828

	

 

1,828

	

 

1,828

	

MLV 214-3 to MLV 219-3: Pig Run - Cal/IMU/MFL-A Combo (M) (9/10/2026)

MLV 214-3 to MLV 219-3: Pig Run - Gauge/Cleaning (M) (9/8/2026) Sta 209 Cambridge: Unit 13A - Install Barring Jack (9/7/2026 - 9/10/2026)




Station 230C (segment 296

FH)

	

 

743

	

 

743

	

 

743

	

370

(373)

	

370

(373)

	

 

743

	

 

743

	

 

743

	

Sta 230C: Scrubber / Filter Inspection (M) (9/9/2026 - 9/10/2026)




Station 245

(segment 245 FH)

	

 

986

	

970

(16)

	

970

(16)

	

970

(16)

	

970

(16)

	

970

(16)

	

970

(16)

	

970

(16)

	

Sta 245: Unit 1A & 2A - Exhaust System & HP Fuel (4/27/2026 - 11/1/2026)




Station 261 Discharge East (segment 261 FH)

	

 

888

	

 

715

(173)

	

 

715

(173)

	

 

715

(173)

	

 

715

(173)

	

 

715

(173)

	

 

715

(173)

	

 

715

(173)

	

Sta 264 Charlton: Unit 1C - Engine Maintenance (8/24/2026 - 10/16/2026)




Station 307

(segment 307 BH)

	

 

1,153

	

 

1,153

	

960

(193)

	

 

1,153

	

 

1,153

	

 

1,153

	

 

1,153

	

 

1,153

	

Station 310 Smethport: Annual ESD Test (9/8/2026)




 

 

Station 313 Discharge (segment 399 FH)

	

 

 

 

 

797

	

 

 

 

590

(207)

	

 

 

 

590

(207)

	

 

 

 

590

(207)

	

 

 

 

590

(207)

	

 

 

 

590

(207)

	

 

 

 

590

(207)

	

 

 

 

590

(207)

	

MLV 313A-101A to MLV 313A-401: Anomaly Remediation (M) (9/7/2026 - 9/19/2026)

MLV 313A-101L to MLV 313A-101A: Anomaly Remediation (M) (9/7/2026 - 9/19/2026)

MLV 313A-403 to MLV 313A-404: Anomaly Remediation (M) (9/7/2026 - 9/19/2026)

MLV 313A-405A to MLV 313A-406: Anomaly Remediation (M) (9/7/2026 - 9/19/2026)




Station 315

(segment 315 BH)

	

 

1,823

	

 

1,823

	

 

1,823

	

 

1,823

	

 

1,823

	

 

1,823

	

 

1,823

	

 

1,823

	

 




Station 321

(segment 321 FH)

	

 

2,102

	

 

2,102

	

1940

(162)

	

1940

(162)

	

1940

(162)

	

 

2,102

	

 

2,102

	

 

2,102

	

Sta 321: Unit 1C - Buffer Air Seal (9/8/2026 - 9/10/2026)




MLV 324

(segment 324 FH)

	

 

1,767

	

 

1,767

	

 

1,767

	

 

1,767

	

 

1,767

	

 

1,767

	

 

1,767

	

 

1,767

	

 




MLV 336 East

(segment 336 FH)

	

 

153

	

 

153

	

 

153

	

137

(16)

	

137

(16)

	

137

(16)

	

137

(16)

	

137

(16)

	

MLV 329AS-1 to MLV 329AD-1: Valve Replacement - MLV 329-1 (M) (9/9/2026 10/9/2026)




This document is updated on a weekly basis and outage schedules/impacts are subject to change as the week progresses.

Dates posted on DART should be deemed correct in the event of conflicts between DART posted dates and dates on this report.

The impacts sheet are based on steady-state hydraulic models assuming recent operating flows, conditions, and various unit outages.




 

	

 

	

 

	

-Primary impact restrictions may be necessary




 

	

TGP - Outage Impact Report

	

 

	

-Major impact restrictions may be necessary




 

	

September 2026 (updated 09/03/26)

	

 

	

-Minor impact restrictions may be necessary depending on flow conditions




 

	

 

	

 

	

-Little to no impact, though minor outages may cause incremental reductions




Station # / Lateral

	

Est Nominal

Operating Capacity (Thousand Dth)

	

Week 1

(8/31 - 9/6)

	

Week 2

(9/7 - 9/13)

	

Week 3

(9/14 - 9/20)

	

Week 4

(9/21 - 9/27)

	

 

Primary Outage(s)




Est. Operational Capacity (Operational Impact) - Thousand Dth




 

 

Station 409A (Alamo) (segment 492 FH)

	

 

 

 

 

274

	

 

	

 

	

 

 

 

 

215

(59)

	

 

 

 

 

125

(149)

	

MLV 409-1 to MLV 406-1: Spike Test (M) (9/14/2026 - 10/31/2026)

MLV 409A-101.1 to MLV 409A-103: Pig Runs - Cleaning / Gauge (M) (9/21/2026) MLV 409A-101.1 to MLV 409A-103: Pig Runs - Cleaning / Gauge (M) (9/22/2026) MLV 409A-101.1 to MLV 409A-103: Pig Runs - Cleaning / Gauge (M) (9/23/2026) MLV 409A-101.1 to MLV 409A-103: Pig Runs - EMAT (M) (9/25/2026)

MLV 409A-101.1 to MLV 409A-103: Pig Runs - MFL-C (M) (9/24/2026)




Station 409 (Donna Line) (segment 490 FH)

	

 

564

	

 

	

 

	

 

564

	

 

564

	

 




Station 1

(segment 101 BH)

	

 

399

	

 

	

 

	

207

(192)

	

300

(99)

	

Sta 1: Station Power Protection System (9/22/2026) MLV 1-1D to MLV 5-1: Spike Test (M) (9/21/2026 - 11/2/2026)

MLV 2-2 to MLV 3-2: Anomaly Remediation (9/8/2026 - 9/18/2026)




 

Station 17

(segment 117 FH)

	

 

 

1,122

	

 

	

 

	

 

1100

(22)

	

 

1085

(37)

	

MLV 17-1D to MLV 20-1A: Pig Run - Chemical Cleaning (9/21/2026) MLV 17-1D to MLV 20-1A: Pig Run - EMAT (9/24/2026)

MLV 17-1D to MLV 20-1A: Pig Run - GAUGE PLATE (9/22/2026) MLV 17-1D to MLV 20-1A: Pig Run - MFL-C (9/23/2026)

MLV 19-1 TO MLV 20-1A: Pipe Replacement (M) (8/6/2026 - 9/18/2026)




Station 25

(segment 125 FH)

	

 

1,078

	

 

	

 

	

 

1,078

	

 

1,078

	

 




Station 40 KN South (segment 501 FH)

	

 

267

	

 

	

 

	

 

200

(67)

	

 

267

	

Sta 500C1: Unit 1A - Engine Inspection (9/14/2026 - 9/18/2026)




Station 47

(segment 143 FH)

	

 

1,343

	

 

	

 

	

 

1,343

	

 

1,343

	

 




Station 63

(segment 163 FH)

	

 

1,242

	

 

	

 

	

 

1117

(125)

	

 

1117

(125)

	

MLV 54-3 to MLV 106-3: Emergent Repair - CAO (2/26/2026 - 12/31/2026) MLV 82-2C to MLV 83-2: Anomaly Remediation (9/21/2026 - 9/26/2026) MLV 83-1A to MLV 83-1: Anomaly Remediation (9/14/2026 - 9/19/2026)

MLV 84-3 to MLV 85-3: Anomaly Remedition (9/22/2026 - 9/27/2026)




Station 823

(segment 823 BH)

	

 

734

	

 

	

 

	

 

734

	

 

734

	

 




Station 834

(segment 834 BH)

	

 

683

	

 

	

 

	

 

670

(13)

	

 

670

(13)

	

Sta 834: Unit 1A - Replace Insulation Blanket (9/14/2026 - 9/15/2026) Sta 834: Unit 2A - Replace Insulation Blanket (9/16/2026 - 9/17/2026) Sta 834: Unit 3A - Replace Insulation Blanket (9/18/2026 - 9/19/2026)

Sta 834: Unit 4A - Replace Insulation Blanket (9/21/2026 - 9/22/2026)




Station 534 South of Pool (segment 530 BH)

	

 

1,550

	

 

	

 

	

 

985

(565)

	

 

1,550

	

MLV 533-2 to MLV 534-2: Pipe Replacement (M) (6/4/2026 - 9/17/2026)




 

 

 

Station 860

(segment 548 BH)

	

 

 

 

 

1,593

	

 

	

 

	

 

 

 

 

935

(658)

	

 

 

 

 

1577

(16)

	

MLV 546-2 to MLV 547-2: Line Recoat (9/14/2026 - 9/18/2026)

Sta 542: Unit 2A - Emergent Repair (4/7/2026 - 9/30/2026) Sta 542: Unit 3A - Emergent Repair (3/26/2026 - 9/18/2026)

Sta 546: Annual ESD Tests & Maintenance (9/14/2026 - 9/18/2026) Sta 546: Unit 7A - Metal in Oil (7/14/2025 - 9/30/2026)

Sta 555: Scrubber/Filter/Separator Clean, Inspect & Filter Change (9/14/2026 - 9/17/2026)

Sta 555: Unit 1B - Hot Gas Path (8/10/2026 - 9/18/2026) Sta 555: Unit 4A - Engine Maintenance (9/21/2026 - 9/24/2026)




Station 860 North (Segment 860 BH)

	

 

1,874

	

 

	

 

	

 

1524

(350)

	

 

1846

(28)

	

Sta 563: Unit 1A - Emergent Repair (8/28/2026 - 9/18/2026)

Sta 860: Unit 1A - Aftercooler Jacket Water Inspection (6/17/2025 - 12/31/2026) Sta 860: Unit 1B - Replace Turbocharger (9/21/2026 - 9/25/2026)




 

 

Station 110

(segment 187 BH)

(south thru Kentucky)

	

 

 

 

 

2,685

	

 

	

 

	

 

 

 

 

2400

(285)

	

 

 

 

 

2405

(280)

	

MLV 105-1 to MLV 105-1A: Anomaly Remediation (9/14/2026 - 9/25/2026) MLV 109-5 to MLV 109-5A: Pipe Replacement (9/14/2026 - 10/12/2026) MLV 109-5A to MLV 110-5: Pipe Replacement (9/14/2026 - 10/12/2026) MLV 110-2 to MLV 114-2: CAO - Force Majeure (M) (7/14/2026 - 12/31/2026)

MLV 54-3 to MLV 106-3: Emergent Repair - CAO (2/26/2026 - 12/31/2026) MLV 93-4 to MLV 94-4: Anomaly Remediation (M) (9/14/2026 - 9/21/2026) MLV 96-3BR to MLV 96-3BL: Spike Test (7/27/2026 - 9/18/2026)

Sta 106: Unit 2D - 4K Solar Turbine Inspection (9/16/2026 - 9/18/2026) Sta 87: Unit 3D - Power side Overhaul (6/22/2026 - 9/30/2026)




Station 114

(segment 114 BH)

	

 

907

	

 

	

 

	

812

(95)

	

 

907

	

Sta 119A: Unit 1A - Solar Turbine Inspection (9/14/2026 - 9/16/2026)




 

	

 

	

 

	

-Primary impact restrictions may be necessary




 

	

TGP - Outage Impact Report

	

 

	

-Major impact restrictions may be necessary




 

	

September 2026 (updated 09/03/26)

	

 

	

-Minor impact restrictions may be necessary depending on flow conditions




 

	

 

	

 

	

-Little to no impact, though minor outages may cause incremental reductions




Station # / Lateral

	

Est Nominal

Operating Capacity (Thousand Dth)

	

Week 1

(8/31 - 9/6)

	

Week 2

(9/7 - 9/13)

	

Week 3

(9/14 - 9/20)

	

Week 4

(9/21 - 9/27)

	

 

Primary Outage(s)




Est. Operational Capacity (Operational Impact) - Thousand Dth




Station 204

(Segment 204 BH)

	

 

1,828

	

 

	

 

	

 

1,828

	

 

1,828

	

 




Station 245

(segment 245 FH)

	

 

986

	

 

	

 

	

970

(16)

	

970

(16)

	

Sta 245: Unit 1A & 2A - Exhaust System & HP Fuel (4/27/2026 - 11/1/2026)




Station 261 Discharge East (segment 261 FH)

	

 

888

	

 

	

 

	

 

715

(173)

	

 

555

(333)

	

Sta 264 Charlton: Annual ESD Test (9/23/2026 - 9/24/2026)

Sta 264 Charlton: Unit 1C - Engine Maintenance (8/24/2026 - 10/16/2026)




Station 307

(segment 307 BH)

	

 

1,153

	

 

	

 

	

 

1,153

	

1010

(143)

	

Sta 310: Unit 1A - Water Washes and Borescope (9/21/2026 - 9/22/2026)




 

 

Station 313 Discharge (segment 399 FH)

	

 

 

 

 

797

	

 

	

 

	

 

 

 

590

(207)

	

 

 

 

 

797

	

MLV 313A-101A to MLV 313A-401: Anomaly Remediation (M) (9/7/2026 - 9/19/2026)

MLV 313A-101L to MLV 313A-101A: Anomaly Remediation (M) (9/7/2026 - 9/19/2026)

MLV 313A-403 to MLV 313A-404: Anomaly Remediation (M) (9/7/2026 - 9/19/2026)

MLV 313A-405A to MLV 313A-406: Anomaly Remediation (M) (9/7/2026 - 9/19/2026)




Station 315

(segment 315 BH)

	

 

1,823

	

 

	

 

	

1675

(148)

	

 

1,823

	

Sta 315: Unit 1B - Water Washes and Borescope (9/16/2026 - 9/17/2026) Sta 315: Unit 2A - Water Washes and Borescope (9/14/2026 - 9/15/2026)




Station 321

(segment 321 FH)

	

 

2,102

	

 

	

 

	

 

2,102

	

1830

(272)

	

Sta 323: Station Outage (9/21/2026 - 9/24/2026)




MLV 324

(segment 324 FH)

	

 

1,767

	

 

	

 

	

 

1,767

	

 

1,767

	

 




MLV 336 East

(segment 336 FH)

	

 

153

	

 

	

 

	

137

(16)

	

137

(16)

	

MLV 329AS-1 to MLV 329AD-1: Valve Replacement - MLV 329-1 (M) (9/9/2026 - 10/9/2026)




This document is updated on a weekly basis and outage schedules/impacts are subject to change as the week progresses.

Dates posted on DART should be deemed correct in the event of conflicts between DART posted dates and dates on this report.

The impacts sheet are based on steady-state hydraulic models assuming recent operating flows, conditions, and various unit outages.

 

	

 

	

 

	

 

	

 

	

-Primary impact restrictions may be necessary




 

	

 

	

TGP - Outage Impact Report

	

 

	

 

	

-Major impact restrictions may be necessary




 

	

October 2026 (updated 09/03/26)

	

 

	

 

	

-Minor impact restrictions may be necessary depending on flow conditions




 

	

 

	

 

	

 

	

-Little to no impact, though minor outages may cause incremental reductions




Station # / Lateral

	

Est Nominal

Operating Capacity (Thousand Dth)

	

Week 1

(9/28 - 10/4)

	

Week 2

(10/5 - 10/11)

	

Week 3

(10/12 - 10/18)

	

Week 4

(10/19 - 10/25)

	

Week 5

(10/26 - 11/1)

	

 

Primary Outage(s)




Est. Operational Capacity (Operational Impact) - Thousand Dth




Station 409A (Alamo) (segment 492 FH)

	

 

274

	

 

215

(59)

	

 

215

(59)

	

 

215

(59)

	

 

215

(59)

	

 

215

(59)

	

MLV 409-1 to MLV 406-1: Spike Test (M) (9/14/2026 - 10/31/2026)




Station 409 (Donna Line) (segment 490 FH)

	

 

564

	

 

564

	

 

564

	

 

564

	

 

564

	

 

564

	

 




Station 1

(segment 101 BH)

	

 

399

	

300

(99)

	

300

(99)

	

300

(99)

	

300

(99)

	

300

(99)

	

MLV 1-1D to MLV 5-1: Spike Test (M) (9/21/2026 - 11/2/2026)




Station 9

(segment 109 BH)

	

 

1,027

	

 

1,027

	

 

1,027

	

 

1,027

	

640

(387)

	

 

1,027

	

MLV 9-2S to MLV 1-2: Pig Runs - Cleaning / Maintenance (M) (10/22/2026) MLV 9-3 to MLV 5-3: Pig Run - Maintenance (M) (10/21/2026)




 

 

Station 17

(segment 117 FH)

	

 

 

 

1,122

	

 

 

 

1,122

	

 

 

985

(137)

	

 

 

980

(142)

	

 

 

1100

(22)

	

 

 

 

1,122

	

MLV 17-2D to MLV 20-2A: Pig Run - Chemical Cleaning (10/19/2026 - 10/20/2026)

MLV 17-2D to MLV 20-2A: Pig Run - GAUGE (10/21/2026) MLV 17-2D to MLV 20-2A: Pig Run - MFL-A (10/22/2026)

MLV 32-2D TO MLV 40-2S: Pig Runs - Maintenance (10/8/2026) MLV 32-3D to MLV 40-3S: Pig Runs - Maintenance (10/13/2026) Sta 25: Annual ESD Test (10/13/2026)




Station 25

(segment 125 FH)

	

 

1,078

	

 

1,078

	

 

1,078

	

 

1,078

	

 

1,078

	

 

1,078

	

 




 

Station 47

(segment 143 FH)

	

 

 

1,343

	

 

1025

(318)

	

 

1025

(318)

	

 

1290

(53)

	

 

1300

(43)

	

 

 

1,343

	

MLV 58-2 to MLV 59-2: Anomaly Remediation (10/10/2026 - 10/20/2026) Sta 47: Scrubber/Filter/Separator Cleaning/Inspection/Changeout (9/28/2026 -

10/2/2026)

Sta 47: Station Transformer Maintenance (10/6/2026)

Sta 47: Unit 1D - 16K hour Overhaul (10/5/2026 - 10/15/2026)




Station 63

(segment 163 FH)

	

 

1,242

	

 

1117

(125)

	

 

1117

(125)

	

 

1117

(125)

	

 

1117

(125)

	

 

1117

(125)

	

MLV 54-3 to MLV 106-3: Emergent Repair - CAO (2/26/2026 - 12/31/2026) MLV 82-1 to MLV 87-1: Pig Run - AFD/Cal/IMU (10/8/2026)

MLV 82-1 to MLV 87-1: Pig Run - Cleaning / Gauge (10/6/2026)

MLV 82-1 to MLV 87-1: Pig Run - EMAT (10/13/2026)




Station 823

(segment 823 BH)

	

 

734

	

 

734

	

 

734

	

 

734

	

 

734

	

 

734

	

 




Station 527

(segment 527 BH)

	

 

2,395

	

 

2,395

	

2285

(110)

	

2020

(375)

	

 

2,395

	

 

2,395

	

Sta. 527 Port Sulphur: Building C - Medium Voltage Electrical Testing (10/5/2026 - 10/9/2026)

Sta 529: Unit 1A - Solar Inspection (10/12/2026 - 10/15/2026)




Station 534

(segment 534 BH)

	

 

1,909

	

 

1,909

	

 

1,909

	

1770

(139)

	

 

1,909

	

 

1,909

	

Sta 538: Boost Pump Vibration Upgrade (10/12/2026 - 10/15/2026)




 

Station 860

(segment 548 BH)

	

 

 

1,593

	

 

1577

(16)

	

 

1375

(218)

	

 

 

1,593

	

 

1181

(412)

	

 

 

1,593

	

Sta 542 Dekalb: Annual ESD Test (10/20/2026 - 10/22/2026) Sta 542: Unit 2A - Emergent Repair (4/7/2026 - 9/30/2026) Sta 546: Unit 7A - Metal in Oil (7/14/2025 - 9/30/2026)

Sta 550 Hamilton: Annual ESD Test (10/5/2026 - 10/9/2026)

Sta 550: Unit 1B - Juction Box Rewire & Unit Valves (9/28/2026 - 10/9/2026)




Station 860 North (Segment 860 BH)

	

 

1,874

	

 

1846

(28)

	

 

1846

(28)

	

 

1475

(399)

	

 

1475

(399)

	

 

1475

(399)

	

MLV 560-2 to MLV 563-2: Pipe Replacements (M) (10/15/2026 - 10/26/2026) Sta 860: Unit 1A - Aftercooler Jacket Water Inspection (6/17/2025 - 12/31/2026)




 

 

 

 

 

Station 110

(segment 187 BH)

(south thru Kentucky)

	

 

 

 

 

 

 

 

2,685

	

 

 

 

 

 

 

2043

(642)

	

 

 

 

 

 

 

2043

(642)

	

 

 

 

 

 

 

2400

(285)

	

 

 

 

 

 

 

2428

(257)

	

 

 

 

 

 

 

1822

(863)

	

MLV 103-3 to MLV 105-3: Crossover Upgrade (10/1/2026 - 10/7/2026) MLV 104-3 to MLV 106-3S: HDD at Kentucky River (10/1/2026 - 10/7/2026) MLV 109-3A to MLV 110-3: Pipe Replacement (10/14/2026 - 10/30/2026) MLV 109-5 to MLV 109-5A: Pipe Replacement (9/14/2026 - 10/12/2026) MLV 109-5A to MLV 110-5: Pipe Replacement (9/14/2026 - 10/12/2026)

MLV 110-2 to MLV 114-2: CAO - Force Majeure (M) (7/14/2026 - 12/31/2026)

MLV 54-3 to MLV 106-3: Emergent Repair - CAO (2/26/2026 - 12/31/2026) MLV 867-2 to MLV 868-2: Anomaly Remediation (10/19/2026 - 10/24/2026) MLV 870-2 to MLV 870-2R: Anomaly Remediation (10/12/2026 - 10/17/2026) MLV 97-3 to MLV 106-3: Pig Run - Cleaning / Gauge (10/27/2026)

MLV 97-3 to MLV 106-3: Pig Run - MFL-S (10/29/2026)

Sta 87: Unit 3D - Power side Overhaul (6/22/2026 - 9/30/2026)

Sta 875: Unit 1A- 8K Solar Turbine Inspection (10/27/2026 - 10/29/2026) Sta 96: Unit 2D Replace Compressor Valves (10/12/2026 - 10/15/2026)




Station 114

(segment 114 BH)

	

 

907

	

 

907

	

853

(54)

	

 

907

	

 

907

	

 

907

	

Sta 118A Tyler Mountain: Annual ESD Test (10/5/2026 - 10/6/2026)




 

 

 

 

Station 204

(Segment 204 BH)

	

 

 

 

 

 

1,828

	

 

 

 

 

1375

(453)

	

 

 

 

 

 

1,828

	

 

 

 

 

1755

(73)

	

 

 

 

 

1755

(73)

	

 

 

 

 

1530

(298)

	

MLV 209-2 to MLV 214-2: Pig Run - Chem Cleaning (10/26/2026) MLV 209-2 to MLV 214-2: Pig Run - Chem Cleaning (10/27/2026) MLV 209-2 to MLV 214-2: Pig Run - Chem Cleaning (10/28/2026) MLV 209-2 to MLV 214-2: Pig Run - Chem Cleaning (10/29/2026) MLV 209-2 to MLV 214-2: Pig Run - Chem Cleaning (10/30/2026) MLV 214-1 to MLV 219-1: Pig Run - Cal/IMU (10/20/2026)

MLV 214-1 to MLV 219-1: Pig Run - Gauge/Cleaning (10/15/2026) MLV 214-1 to MLV 219-1: Pig Run - MFL-C (10/22/2026)

Sta 204: Scrubber Filter Change (10/1/2026 - 10/3/2026) Sta 209 Cambridge: Scrubber Filter (9/28/2026 - 9/30/2026)




 

TGP - Outage Impact Report October 2026 (updated 09/03/26)

	

-Primary impact restrictions may be necessary




-Major impact restrictions may be necessary




-Minor impact restrictions may be necessary depending on flow conditions




-Little to no impact, though minor outages may cause incremental reductions




Station # / Lateral

	

Est Nominal

Operating Capacity (Thousand Dth)

	

Week 1

(9/28 - 10/4)

	

Week 2

(10/5 - 10/11)

	

Week 3

(10/12 - 10/18)

	

Week 4

(10/19 - 10/25)

	

Week 5

(10/26 - 11/1)

	

 

Primary Outage(s)




Est. Operational Capacity (Operational Impact) - Thousand Dth




Station 233

(segment 233 FH)

	

 

459

	

355

(104)

	

 

459

	

 

459

	

 

459

	

 

459

	

MLV 233-2 to MLV 235-2: Pig Run (9/30/2026)




Station 245

(segment 245 FH)

	

 

986

	

970

(16)

	

970

(16)

	

970

(16)

	

970

(16)

	

760

(226)

	

Sta 245: Unit 1A & 2A - Exhaust System & HP Fuel (4/27/2026 - 11/1/2026) Sta 245-1 to MLV 249-1: Pig Run - EMAT (10/28/2026)

Sta 245-1 to MLV 249-1: Pig Run - MFL-C - Rerun (10/27/2026)




Station 261 Discharge East (segment 261 FH)

	

 

888

	

 

500

(388)

	

 

715

(173)

	

 

555

(333)

	

 

888

	

 

888

	

Sta 261 Agawam: Annual ESD test (M) (9/28/2026 - 10/2/2026)

Sta 264 Charlton: Unit 1C - Engine Maintenance (8/24/2026 - 10/16/2026) Sta 264: Oil System (10/12/2026 - 10/16/2026)




 

Station 307

(segment 307 BH)

	

 

 

1,153

	

 

775

(378)

	

 

695

(458)

	

 

765

(388)

	

 

 

1,153

	

 

 

1,153

	

MLV 302-2 to MLV 303-2: Anomaly Remediation (9/28/2026 - 10/10/2026) Sta 219: Annual ESD Test & Scrubber Maintenance (10/12/2026 - 10/16/2026)

Sta 303A: Unit 1A - Water Wash (10/6/2026 - 10/7/2026) Sta 307: Unit 4A - Trabon (9/29/2026 - 10/2/2026)




Station 313 Discharge (segment 399 FH)

	

 

797

	

 

797

	

 

797

	

 

797

	

 

797

	

 

797

	

Sta 405A: Unit 1A - 4k Waterwash (10/13/2026)

Sta 405A: Unit 1A - 8K Solar Turbine Inspection (10/14/2026)




Station 315

(segment 315 BH)

	

 

1,823

	

 

1,823

	

 

1,823

	

 

1,823

	

 

1,823

	

 

1,823

	

 




MLV 324

(segment 324 FH)

	

 

1,767

	

1450

(317)

	

 

1,767

	

 

1,767

	

1550

(217)

	

 

1,767

	

MLV 325-1 to MLV 329-1: Pig runs - Cleaning/Gauge (M) (10/19/2026) MLV 325-1 to MLV 329-1: Pig runs - EMAT (M) (10/20/2026)

Sta 325: Station Outage (9/29/2026 - 10/1/2026)




MLV 336 East

(segment 336 FH)

	

 

153

	

137

(16)

	

137

(16)

	

 

153

	

 

153

	

 

153

	

MLV 329AS-1 to MLV 329AD-1: Valve Replacement - MLV 329-1 (M) (9/9/2026 - 10/9/2026)




Cranston Lateral South

(segment 281

FH)

	

 

187

	

 

187

	

 

187

	

 

125

(62)

	

 

187

	

 

187

	

Sta 265: Unit 1A - Replace Lube Oil Fan (10/12/2026)




Station 405 HC Line (segment 299 FH)

	

 

794

	

 

794

	

 

794

	

 

670

(124)

	

 

794

	

 

794

	

Sta 405A: Unit 1A - 4k Waterwash (10/13/2026) ; Sta 405A: Unit 1A - 8K Solar Turbine Inspection (10/14/2026)




Station 224

(segment 224 FH)

	

 

388

	

 

388

	

200

(188)

	

 

388

	

 

388

	

 

388

	

MLV 229-2 to MLV 232-2: Pig runs - Maintenance (M) (10/6/2026)




This document is updated on a weekly basis and outage schedules/impacts are subject to change as the week progresses. Dates posted on DART should be deemed correct in the event of conflicts between DART posted dates and dates on this report.

The impacts sheet are based on steady-state hydraulic models assuming recent operating flows, conditions, and various unit outages.

 

	

 

	

 

	

-Primary impact restrictions may be necessary




 

	

TGP - Outage Impact Report

	

 

	

-Major impact restrictions may be necessary




 

	

November 2026 (updated 09/03/26)

	

 

	

-Minor impact restrictions may be necessary depending on flow conditions




 

	

 

	

 

	

-Little to no impact, though minor outages may cause incremental reductions




Station # / Lateral

	

Est Nominal

Operating Capacity (Thousand Dth)

	

Week 1

(11/2 - 11/8)

	

Week 2

(11/9 - 11/15)

	

Week 3

(11/16 - 11/22)

	

Week 4

(11/23 - 11/29)

	

 

Primary Outage(s)




Est. Operational Capacity (Operational Impact) - Thousand Dth




Station 409 (Donna Line) (segment 490 FH)

	

 

587

	

 

587

	

 

587

	

 

587

	

 

587

	

 




MLV 406

(segment 406 BH)

	

 

479

	

 

479

	

440

(39)

	

267

(212)

	

 

479

	

MLV 400-1 to MLV 409-1: Pig Run - Maintenance Cleaning (M) (11/10/2026) MLV 400-2 to MLV 409-2: Pig Run - Maintenance Cleaning (M) (11/17/2026)




Station 1

(segment 101 BH)

	

 

438

	

357

(81)

	

252

(186)

	

 

438

	

 

438

	

MLV 1-1D to MLV 5-1: Spike Test (M) (9/21/2026 - 11/2/2026)

MLV 1-1D to MLV 9-1S: Pig Run - Maintenance / Cleaning (M) (11/10/2026)




Station 17

(segment 117 FH)

	

 

1,138

	

 

1,138

	

 

1,138

	

 

1,138

	

 

1,138

	

 




Station 25

(segment 125 FH)

	

 

1,095

	

 

1,095

	

 

1,095

	

 

1,095

	

 

1,095

	

 




Station 40 South

(segment 132 FH)

	

 

1,294

	

 

1,294

	

 

1,294

	

915

(379)

	

 

1,294

	

Sta 32: Annual ESD Test (11/17/2026 - 11/18/2026)




Station 47

(segment 143 FH)

	

 

1,428

	

1350

(78)

	

1350

(78)

	

 

1,428

	

 

1,428

	

MLV 61-3 to MLV 62-3: Pipe Replacements (11/2/2026 - 11/13/2026)




Station 63

(segment 163 FH)

	

 

1,192

	

871

(321)

	

1067

(125)

	

1067

(125)

	

1067

(125)

	

MLV 54-3 to MLV 106-3: Emergent Repair - CAO (2/26/2026 - 12/31/2026) MLV 71-3D to MLV 74-3: Pig Runs - Cleaning / Gauge (11/3/2026)

MLV 71-3D to MLV 74-3: Pig Runs - TDW MDS (11/5/2026)




Station 823

(segment 823 BH)

	

 

758

	

210

(548)

	

 

758

	

 

758

	

 

758

	

Sta 827 to Sta 823: Pig Run - Maintenance (M) (11/5/2026) Sta 834 to Sta 827: Maintenance Pig (M) (11/5/2026)




Station 860

(segment 548 BH)

	

 

1,665

	

 

1,665

	

 

1,665

	

 

1,665

	

 

1,665

	

 




 

Station 860 North (Segment 860 BH)

	

 

 

2,059

	

 

 

2031

(28)

	

 

 

2031

(28)

	

 

 

2031

(28)

	

 

 

2031

(28)

	

Sta 860: Unit 1A - Aftercooler Jacket Water Inspection (6/17/2025 - 12/31/2026) Sta 860: Unit 1C - 4K/Turbine Waterwash/Boroscope (11/2/2026 - 11/3/2026) Sta 860: Unit 2C - 4K/Turbine Waterwash/Boroscope (11/3/2026 - 11/4/2026)




Station 110

(segment 187 BH)

(south thru

Kentucky)

	

 

 

2,594

	

 

1951

(643)

	

 

2327

(267)

	

 

2327

(267)

	

 

2327

(267)

	

MLV 110-2 to MLV 114-2: CAO - Force Majeure (M) (7/14/2026 - 12/31/2026)

MLV 54-3 to MLV 106-3: Emergent Repair - CAO (2/26/2026 - 12/31/2026) MLV 97-3 to MLV 106-3: Pig Run - EMAT (11/5/2026)

MLV 97-3 to MLV 106-3: Pig Run - MFL-C (11/3/2026)




Station 114

(segment 114 BH)

	

 

946

	

858

(88)

	

 

946

	

 

946

	

 

946

	

Sta 118A: Solar Turbine Inspection (11/2/2026 - 11/4/2026)




 

Station 204

(Segment 204 BH)

	

 

 

1,888

	

 

 

1765

(123)

	

 

 

1425

(463)

	

 

 

1425

(463)

	

 

 

1,888

	

MLV 204-4 to MLV 209-4: Pig Run - Cal/IMU (11/12/2026) MLV 204-4 to MLV 209-4: Pig Run - EMAT (11/19/2026) MLV 204-4 to MLV 209-4: Pig Run - Gauge (11/10/2026) MLV 204-4 to MLV 209-4: Pig Run - MFL-C (11/17/2026) MLV 209-2 to MLV 214-2: Pig Run - CAL/IMU (11/3/2026) MLV 209-2 to MLV 214-2: Pig Run - EMAT (11/5/2026)




Station 245

(segment 245 FH)

	

 

1,043

	

 

1,043

	

 

1,043

	

 

1,043

	

 

1,043

	

 




Station 261 Discharge East (segment 261 FH)

	

 

1,034

	

 

1,034

	

 

1,034

	

 

1,034

	

 

1,034

	

 




Station 307

(segment 307 BH)

	

 

1,203

	

 

1,203

	

 

1,203

	

 

1,203

	

 

1,203

	

 




Station 313 Discharge (segment 399 FH)

	

 

810

	

 

810

	

 

810

	

 

810

	

 

810

	

 




Station 315

(segment 315 BH)

	

 

1,885

	

 

1,885

	

 

1,885

	

 

1,885

	

 

1,885

	

 




MLV 324

(segment 324 FH)

	

 

1,883

	

 

1,883

	

 

1,883

	

 

1,883

	

 

1,883

	

 




 

	

 

	

 

	

-Primary impact restrictions may be necessary




 

	

TGP - Outage Impact Report

	

 

	

-Major impact restrictions may be necessary




 

	

November 2026 (updated 09/03/26)

	

 

	

-Minor impact restrictions may be necessary depending on flow conditions




 

	

 

	

 

	

-Little to no impact, though minor outages may cause incremental reductions




Station # / Lateral

	

Est Nominal

Operating Capacity (Thousand Dth)

	

Week 1

(11/2 - 11/8)

	

Week 2

(11/9 - 11/15)

	

Week 3

(11/16 - 11/22)

	

Week 4

(11/23 - 11/29)

	

 

Primary Outage(s)




Est. Operational Capacity (Operational Impact) - Thousand Dth




This document is updated on a weekly basis and outage schedules/impacts are subject to change as the week progresses.

Dates posted on DART should be deemed correct in the event of conflicts between DART posted dates and dates on this report.

The impacts sheet are based on steady-state hydraulic models assuming recent operating flows, conditions, and various unit outages.


						
..
Transco

2026 Major Construction and Maintenance Projects

SEV 1/5
Informational

Pre-screen severity 1 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Pipeline: Transco
Notice: 2026 Major Construction and Maintenance Projects
Posted: 09/03/2026 15:26:06 CDT
Notice ID: 17238008

TRANSCONTINENTAL GAS PIPE LINE COMPANY, LLC

Critical:
 Y

Notice Eff Date:
 09/03/2026

Notice Eff Time:
 15:26:06 CDT

Notice End Date:
 

Notice End Time:
 

Notice ID:
 17238008

Notice Stat Desc:
 Supersede

Notice Type Desc:
 Maint

Post Date:
 09/03/2026

Post Time:
 15:26:06 CDT

Prior Notice:
 17213846

Reqrd Rsp Desc:
 No response required

Rsp Date:
 

Rsp Time:
 

TSP:
 007933021

TSP Name:
 TRANSCONTINENTAL GAS PIPE LINE COMPANY, LLC

Notice Text: 
Subject: 
2026 Major Construction and Maintenance Projects
Please be advised that Transco’s major construction and maintenance schedule for projects that are currently planned for 2026 has been updated and can be accessed using the link below. Note the addition of a tab specifically dedicated to Pipeline Inspection (ILI) Activities. The link to the maintenance schedule will also be available on the informational postings portion of the 
1Line portal
 under the operational information tab.

While significant effort has been made to provide dates for the 2026 schedule, the dates and duration of the planned work are subject to change. Transco will provide revisions to the maintenance schedule as updated information is available.

Some of this work will affect the availability of interruptible transportation services (IT and secondary FT). The extent of this impact will depend on operating conditions at the time of the outage. If a maintenance activity is expected to affect the availability of transportation services, additional information will be posted prior to commencement of that activity.

Click 
here
 to access the 2026 Maintenance Schedule link.
Natural Gas Pipeline (NGPL)

[MAINTENANCE] OUTAGE IMPACT REPORT 9-3-26

SEV 1/5
Informational

Pre-screen severity 1 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Pipeline: Natural Gas Pipeline (NGPL)
Notice Type: MAINTENANCE
Subject: OUTAGE IMPACT REPORT 9-3-26
Posted: 09/03/2026 2:23:23PM
Effective: 09/03/2026 2:23:23PM
End Date: 09/04/2026 9:00:00AM

TSP/TSP Name:  6931794-NATURAL GAS PIPELINE CO. Critical: Y
Notice Type Desc (1):  MAINTENANCE Notice Type Desc (2):  MAINTENANCE
Notice Eff Date/Time:  09/03/2026 2:23:23PM Notice End Date/Time:  09/04/2026 9:00:00am
Post Date/Time:  9/3/2026 2:23:23 PM Notice ID: 47200
Reqrd Rsp:  1 Rsp Date/Time:  9/3/2026 12:00:00 AM
Notice Stat Desc:  INITIATE Prior Notice: 
Subject:  OUTAGE IMPACT REPORT 9-3-26
Notice Text:
OUTAGE IMPACT REPORT UPDATE
 
Natural has posted an updated Outage Impact Report on its website.
 
The report outlines scheduled projects that may affect customers and includes:
 
·         Impacted pipeline segments
·         Estimated start and finish dates
·         Brief project descriptions
·         Anticipated shipper impacts
 
Changes to existing projects and newly added projects are highlighted in yellow for easy reference.  In addition, Natural will continue to post detailed updates on specific maintenance projects with direct shipper impacts on its interactive website as needed.  The full maintenance plan is accessible via Natural's portal page or by clicking the link below:
 
Outage Impact Report -9-3-26
 
If you have any questions, please contact your Account Director or Scheduling Representative.
Trunkline Gas Company

[Trunkline Gas Company] [Force Majeure] TGC Force Majeure Lifted: Kountze Station Additional Power Outages

SEV 1/5
Informational

Pre-screen severity 1 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Pipeline: Trunkline Gas Company
Notice ID: 68344
Notice Type: Force Majeure
Subject: TGC Force Majeure Lifted: Kountze Station Additional Power Outages
Posted: 2026-09-03 14:18:00.0
Effective: 2026-09-03 14:18:00.0
End Date: 

Notice ID: 68344
Notice Type: MAJ
Critical: Y
Reqrd Rsp Desc: No Response Required
Posting Date/Time: 2026-09-03 14:18:00.0
Subject: TGC Force Majeure Lifted: Kountze Station Additional Power Outages
Notice Effective Date/Time: 2026-09-03 14:18:00.0
Notice End Date/Time: 2200-01-01 00:00:00.0
Notice Text: 09/03/2026 TGC Force Majeure Lifted: Kountze Station Additional Power Outages Effective immediately, Trunkline has lifted the second Notice of Force Majeure for the Kountze Station Power Outages. If you have any questions, please contact your Customer Service or Marketing Representative.
El Paso Natural Gas (EPNG)

[FORCE MAJEURE] Force Majeure Lifted–Seligman C Station

SEV 1/5
Informational

Pre-screen severity 1 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Pipeline: El Paso Natural Gas (EPNG)
Notice Type: FORCE MAJEURE
Subject: Force Majeure Lifted–Seligman C Station
Posted: 09/03/2026 10:01:03AM
Effective: 09/03/2026 10:01:03AM
End Date: 09/04/2026 9:00:00AM

TSP/TSP Name:  8001703-EL PASO NATURAL GAS CO. L.L.C. Critical: Y
Notice Type Desc (1):  FORCE MAJEURE Notice Type Desc (2):  FORCE MAJEURE
Notice Eff Date/Time:  09/03/2026 10:01:03AM Notice End Date/Time:  09/04/2026 9:00:00am
Post Date/Time:  9/3/2026 10:01:03 AM Notice ID: 629528
Reqrd Rsp:  5 Rsp Date/Time: 
Notice Stat Desc:  TERMINATE Prior Notice:  629431
Subject:  Force Majeure Lifted–Seligman C Station
Notice Text:
Force Majeure Lifted – Seligman “C” Station
 
El Paso Natural Gas Company, L.L.C. (EPNG) has resolved the Force Majeure event declared on Tuesday, August 25, 2026 (Reference Critical Notice No. 629431) associated with its Seligman “C” Compressor Station located in Yavapai County, Arizona. As such, EPNG will be increasing the capacity through the NORTH ML constraint effective September 3, 2026, Intraday 1 Cycle, (Cycle 3).
EPNG will be posting an updated maintenance notice to reflect the increased capacity through the NORTH ML constraint.
This incident constitutes an event of Force Majeure under Section 11.3 of the General Terms and Conditions of EPNG's FERC Gas Tariff.
For scheduling questions, please call your scheduling representative at (800) 238-3764.
For operational and capacity information, please call Russ Pyeatt at (719) 520-3729, Dan English at (719) 520-4722, Morgan McCasland at (719) 520-4339 or John Althoff at (719) 667-7750.
For media inquiries, please contact media relations at media_relations@kindermorgan.com.
EGTS

Steuben Station Maintenance Completed

SEV 1/5
Informational

Pre-screen severity 1 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Pipeline: EGTS
Notice ID: 1013344
Subject: Steuben Station Maintenance Completed
Notice Type: Notices
Posted: 2026-09-03T12:39:48.816
Effective: 2026-09-03T15:00:00
naesbNoticeTypeDescription: Capacity Constraint
subcategory: Critical
tspDefinedNoticeTypeDescription: Maintenance
Columbia Gulf Transmission (CGT)

CAPACITY POSTING - TIM for September 4, 2026

UNSCORED
Informational
View original notice text
TSP Name Columbia Gulf Transmission, LLC
TSP 007854581
Notice Type Description: Capacity Constraint

Notice Stat Desc: Initiate

Prior Notice: 

Critical: Y

Reqrd Rsp Desc: No Response Required
Post

Notice Effective

Notice End



Response
Post Date: 09/03/26

09/03/26

10/03/26
Subject: Subject: CAPACITY POSTING - TIM for September 4, 2026
Author: Author: Dillon Schoolcraft
Notice Text
COLUMBIA GULF TRANSMISSION, LLC DAILY CAPACITY POSTING 

Columbia Gulf Transmission LLC (CGT) posts projections of anticipated restrictions at least 24 hours prior to the time when nominations are due. These advance forecasts are subject to change based on actual operating conditions. Customers should submit nominations for Timely Cycle to determine whether the service is available under current conditions. 

============================================================================

============================================================================

FORCE MAJEURE / OFO 

No Force majeure is necessary. 

No Operational Flow Order (OFO) is necessary.

============================================================================

============================================================================

Customers are encouraged to monitor scheduled volumes on the Operationally Available Capacity (OAC) screen on Navigates Informational Postings, as nominations may fluctuate based on market conditions.

============================================================================

============================================================================

----------------------------------------------------------------------------

INTERNAL CONSTRAINTS-- Total Capacity (Net Backhaul):

----------------------------------------------------------------------------

StanSEG – 1,950,000 

ClemSEG – Total Capacity  

HartSEG – Total Capacity

HampSEG – Total Capacity

CorinSEG – Total Capacity 

BannSEG – 2,300,000

InvrnSEG – Total Capacity 

ShelSEG – Total Capacity

DelhiSEG – Total Capacity

AlexSEG – Total Capacity  

RayneSEG – Total Capacity

WLSEG – Total Capacity

ELSEG – Total Capacity 

EL300SEG – Total Capacity 

HoumaSEG – Total Capacity

----------------------------------------------------------------------------

INTERNAL CONSTRAINTS-- Total Capacity (Net Forwardhaul):

----------------------------------------------------------------------------

StanSEG – Total Capacity 

ClemSEG – Total Capacity

HartSEG – Total Capacity

HampSEG – Total Capacity

CorinSEG – Total Capacity

BannSEG – Total Capacity

InvrnSEG – Total Capacity

ShelSEG – Total Capacity

DelhiSEG - Total Capacity

AlexSEG – Total Capacity

RayneSEG – Total Capacity

WLSEG – Total Capacity

ELSEG – Total Capacity 

EL300SEG – Total Capacity  

HoumaSEG – Total Capacity

               

----------------------------------------------------------------------------

POINT CONSTRAINTS -- Total Capacity:

----------------------------------------------------------------------------

Note: Points listed are controlled by less than meter capacity.

401 - CROSSTEX-GIBSON - 0

445 - TRANSCO / TERREBONNE - 0

481 - SEA ROBIN-ERATH - 0

3194 - TETCO ADAIR CO., KY (Receipts) - Total Capacity (Primary Only)

4051 - LAFAYETTE - ACADIA - Total Capacity (Primary Only)

4078 - SONAT-SHADYSIDE - Total Capacity (Primary Only) 

4098 - BURLINGTON - TERREBONNE - 0

4118 - FLORIDA GAS - Total Capacity (Primary Only)

4123 - EGAN STOR-ACADIA-REC (Receipts and Deliveries) - 370,000 

4137 - CLECO-TECHE - Total Capacity (Primary Only)

4186 - DISCOVERY GAS TRANSMISSION (Deliveries) - Total Capacity (Primary Only)

4197 - MidWestern Pipeline (Deliveries) - 50,000

4204D - GULF SOUTH DELHI Delivery - Total Capacity (Primary Only)

4208R - SOUTHEASTERN SUPPLY HEADER (SESH) - Receipt - 0

4221 - GULF CROSSING - Total Capacity (Primary Only)

4222 - Texas Gas (Isola) - 0

4315 - BROADMORE RD (Receipts) - 775,000 

5112 - NORAM PERRYVILLE Delivery - Total Capacity (Primary Only) 

----------------------------------------------------------------------------

DUE PIPE AND DUE SHIPPER AVAILABILITY:

----------------------------------------------------------------------------

Due Pipe - Available 

Due Shipper - Not Available

============================================================================

============================================================================

PAL & IT BUSINESS

Representatives are available on a daily basis to discuss PAL transactions with customers who have executed master PAL service agreements. (Reminder: Each PAL transaction including rate, term, quantity and point(s) must be provided for and approved on the Appendix A under the Master PAL Agreement). Customers who are interested in PAL transactions for next-day or longer-term park and/or lend transactions or daily discounted IT paths should contact Diana Roberts at 832-758-0900 (ICE droberts6) or Adam Herndon at 832-689-4510 (ICE adherndon) for more information.  

----------------------------------------------------------------------------

AUTO PAL AVAILABILITY:

----------------------------------------------------------------------------

Effective with EVENING Cycle for each Gas Day, Auto Parks/Loans will be limited to +/- 5,000 Dth. Customers are reminded the intent of AutoPAL service is to utilize nominal quantities to resolve pool imbalances that result from upstream or downstream reductions during the cycle. This service should not be used for parking or loaning large quantities.

AutoPAL Parks and Loan Payback - Available

AutoPAL Loans and Unparks - Available

* Denotes a change from previous posting.
Corpus Christi LNG

CTPL - Annual Charge Adjustment (ACA) Charge Effective October 1, 2026

SEV 1/5
Informational

Pre-screen severity 1 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Facility: Corpus Christi LNG
Notice ID: 1981
Notice Type: Rates and Charges
Status: Active
Title: CTPL - Annual Charge Adjustment (ACA) Charge Effective October 1, 2026
Effective Date/Time: 2026-09-02T08:59:00
End Date/Time: 2026-12-31T00:00:00
Posted: 2026-09-02T09:03:51.53
Note: Effective/End Date above is the posting's overall coverage window, NOT necessarily one continuous outage -- see Notice Text and/or the embedded image below for the actual per-job schedule.

Notice Text:
Effective October 1, 2026, and until further notice, the Annual Charge Adjustment (ACA) Rate charged by Cheniere Creole Trail Pipeline, L.P. (CTPL), as calculated and published by the Federal Energy Regulatory Commission, will change to $0.0013/Dth from the current rate of $0.0015/Dth.     If you should have any questions, please do not hesitate to contact Customer Services at 713-375-5900 or email Cheniere.CTPL@Cheniere.com .
Columbia Gulf Transmission (CGT)

CAPACITY POSTING - TIM for September 3, 2026

UNSCORED
Informational
View original notice text
TSP Name Columbia Gulf Transmission, LLC
TSP 007854581
Notice Type Description: Capacity Constraint

Notice Stat Desc: Initiate

Prior Notice: 

Critical: Y

Reqrd Rsp Desc: No Response Required
Post

Notice Effective

Notice End



Response
Post Date: 09/02/26

09/02/26

10/02/26
Subject: Subject: CAPACITY POSTING - TIM for September 3, 2026
Author: Author: Zachery Heaver
Notice Text
COLUMBIA GULF TRANSMISSION, LLC DAILY CAPACITY POSTING 

Columbia Gulf Transmission LLC (CGT) posts projections of anticipated restrictions at least 24 hours prior to the time when nominations are due. These advance forecasts are subject to change based on actual operating conditions. Customers should submit nominations for Timely Cycle to determine whether the service is available under current conditions. 

============================================================================

============================================================================

FORCE MAJEURE / OFO 

No Force majeure is necessary. 

No Operational Flow Order (OFO) is necessary.

============================================================================

============================================================================

Customers are encouraged to monitor scheduled volumes on the Operationally Available Capacity (OAC) screen on Navigates Informational Postings, as nominations may fluctuate based on market conditions.

============================================================================

============================================================================

----------------------------------------------------------------------------

INTERNAL CONSTRAINTS-- Total Capacity (Net Backhaul):

----------------------------------------------------------------------------

StanSEG – 1,950,000 

ClemSEG – Total Capacity  

HartSEG – Total Capacity

HampSEG – Total Capacity

CorinSEG – Total Capacity 

BannSEG – 2,300,000

InvrnSEG – Total Capacity 

ShelSEG – Total Capacity

DelhiSEG – Total Capacity

AlexSEG – Total Capacity  

RayneSEG – Total Capacity

WLSEG – Total Capacity

ELSEG – Total Capacity 

EL300SEG – Total Capacity 

HoumaSEG – Total Capacity

----------------------------------------------------------------------------

INTERNAL CONSTRAINTS-- Total Capacity (Net Forwardhaul):

----------------------------------------------------------------------------

StanSEG – Total Capacity 

ClemSEG – Total Capacity

HartSEG – Total Capacity

HampSEG – Total Capacity

CorinSEG – Total Capacity

BannSEG – Total Capacity

InvrnSEG – Total Capacity

ShelSEG – Total Capacity

DelhiSEG - Total Capacity

AlexSEG – Total Capacity

RayneSEG – Total Capacity

WLSEG – Total Capacity

ELSEG – Total Capacity 

EL300SEG – Total Capacity  

HoumaSEG – Total Capacity

               

----------------------------------------------------------------------------

POINT CONSTRAINTS -- Total Capacity:

----------------------------------------------------------------------------

Note: Points listed are controlled by less than meter capacity.

401 - CROSSTEX-GIBSON - 0

445 - TRANSCO / TERREBONNE - 0

481 - SEA ROBIN-ERATH - 0

3194 - TETCO ADAIR CO., KY (Receipts) - Total Capacity (Primary Only)

4051 - LAFAYETTE - ACADIA - Total Capacity (Primary Only)

4078 - SONAT-SHADYSIDE - Total Capacity (Primary Only) 

4098 - BURLINGTON - TERREBONNE - 0

4118 - FLORIDA GAS - Total Capacity (Primary Only)

4123 - EGAN STOR-ACADIA-REC (Receipts and Deliveries) - 370,000 

4137 - CLECO-TECHE - Total Capacity (Primary Only)

4186 - DISCOVERY GAS TRANSMISSION (Deliveries) - Total Capacity (Primary Only)

4197 - MidWestern Pipeline (Deliveries) - 50,000

4204D - GULF SOUTH DELHI Delivery - Total Capacity (Primary Only)

4208R - SOUTHEASTERN SUPPLY HEADER (SESH) - Receipt - 0

4221 - GULF CROSSING - Total Capacity (Primary Only)

4222 - Texas Gas (Isola) - 0

4315 - BROADMORE RD (Receipts) - 775,000 

5112 - NORAM PERRYVILLE Delivery - Total Capacity (Primary Only) 

----------------------------------------------------------------------------

DUE PIPE AND DUE SHIPPER AVAILABILITY:

----------------------------------------------------------------------------

Due Pipe - Available 

Due Shipper - Not Available

============================================================================

============================================================================

PAL & IT BUSINESS

Representatives are available on a daily basis to discuss PAL transactions with customers who have executed master PAL service agreements. (Reminder: Each PAL transaction including rate, term, quantity and point(s) must be provided for and approved on the Appendix A under the Master PAL Agreement). Customers who are interested in PAL transactions for next-day or longer-term park and/or lend transactions or daily discounted IT paths should contact Diana Roberts at 832-758-0900 (ICE droberts6) or Adam Herndon at 832-689-4510 (ICE adherndon) for more information.  

----------------------------------------------------------------------------

AUTO PAL AVAILABILITY:

----------------------------------------------------------------------------

Effective with EVENING Cycle for each Gas Day, Auto Parks/Loans will be limited to +/- 5,000 Dth. Customers are reminded the intent of AutoPAL service is to utilize nominal quantities to resolve pool imbalances that result from upstream or downstream reductions during the cycle. This service should not be used for parking or loaning large quantities.

AutoPAL Parks and Loan Payback - Available

AutoPAL Loans and Unparks - Available

* Denotes a change from previous posting.
Northwest Pipeline

Overrun Entitlement Warning Lifted

SEV 1/5
Informational

Pre-screen severity 1 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Pipeline: Northwest Pipeline
Notice: Overrun Entitlement Warning Lifted
Notice ID: 33005

Capacity

Operationally Available
Unsubscribed

Gas Quality

Gas Quality
Gas Quality Tariff Provisions
Gas Quality Sampling Procedures
 Gas Quality Resolution Report
RNG Operating Policy

Index of Customers

Locations

Notices

Critical
Non-Critical
Planned Service Outage
Request to Purchase Releasable Capacity
Waste Heat

Posted Imbalances

Regulatory

FERC Watch
Proposed Tariff Filings

Standards of Conduct

Affiliate Names & Addresses
Affiliate Tariff Waivers
Chief Compliance Officer
Employee Transfers
Implementation Procedures
Information Disclosure
Job Titles & Descriptions
Potential Mergers
Shared Facilities
Voluntary Consent

Tariff

Title Sheet/Section
Table Of Contents
Preliminary Statement
Map
Currently Effective Rates
Rate Schedules
General Terms and Conditions
Form Of Service Agreement
 Entire Tariff
Sheet/Section Index

Transactional Reporting

Capacity Release
Firm
Interruptible

Capacity Release Indices

TSP Capacity Offering

Maintenance Schedule

Commercial Contacts

Agreements/Forms

Portal History

Other

Downloads

Search

Search - Tariff
Search - Rate Schedules
Search - General Terms
Search - Form of Service Agreement
Search - Entire Portal

Customer Activities

Site Map

Northwest Pipeline LLC Notice Detail

Print

Northwest Pipeline LLC

NOTICE # 26-168

Overrun Entitlement Warning Lifted

 posted on
 
Sep 1 2026 8:02AM

TSP Name: Northwest Pipeline LLC TSP: 67977322

Critical: Y
Notice Stat Desc: SUPERSEDE
Notice Type Desc: PIPELINE CONDITIONS
Post D/T: 09/01/2026 8:00 AM MCT
Notice Eff D/T: 09/01/2026 8:00 AM MCT
Notice End D/T: 
Reqrd Rsp Desc: No response required
Rsp D/T: 

Notice ID: 26-168
Prior Notice: 26-158
Subject: Overrun Entitlement Warning Lifted

Notice Text:

Effective immediately, Northwest is lifting the Overrun 
Entitlement Warning that was originally issued in All Shipper’s 
Notice 26-158.
Northwest requests that shippers continue to be diligent in 
managing their supply and demand needs.
If you have any questions, please call your Commercial Services 
Representative or the hotline at 713-215-6301.
Northwest Pipeline

Sumas Meter Upgrade Part 1 - Deficiency Period Ending

SEV 1/5
Informational

Pre-screen severity 1 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
Pipeline: Northwest Pipeline
Notice: Sumas Meter Upgrade Part 1 - Deficiency Period Ending
Notice ID: 33007

Capacity

Operationally Available
Unsubscribed

Gas Quality

Gas Quality
Gas Quality Tariff Provisions
Gas Quality Sampling Procedures
 Gas Quality Resolution Report
RNG Operating Policy

Index of Customers

Locations

Notices

Critical
Non-Critical
Planned Service Outage
Request to Purchase Releasable Capacity
Waste Heat

Posted Imbalances

Regulatory

FERC Watch
Proposed Tariff Filings

Standards of Conduct

Affiliate Names & Addresses
Affiliate Tariff Waivers
Chief Compliance Officer
Employee Transfers
Implementation Procedures
Information Disclosure
Job Titles & Descriptions
Potential Mergers
Shared Facilities
Voluntary Consent

Tariff

Title Sheet/Section
Table Of Contents
Preliminary Statement
Map
Currently Effective Rates
Rate Schedules
General Terms and Conditions
Form Of Service Agreement
 Entire Tariff
Sheet/Section Index

Transactional Reporting

Capacity Release
Firm
Interruptible

Capacity Release Indices

TSP Capacity Offering

Maintenance Schedule

Commercial Contacts

Agreements/Forms

Portal History

Other

Downloads

Search

Search - Tariff
Search - Rate Schedules
Search - General Terms
Search - Form of Service Agreement
Search - Entire Portal

Customer Activities

Site Map

Northwest Pipeline LLC Notice Detail

Print

Northwest Pipeline LLC

NOTICE # 26-170

Sumas Meter Upgrade Part 1 - Deficiency Period Ending

 posted on
 
Sep 1 2026 12:11PM

TSP Name: Northwest Pipeline LLC TSP: 67977322

Critical: Y
Notice Stat Desc: SUPERSEDE
Notice Type Desc: MAINTENANCE
Post D/T: 09/01/2026 11:53 AM MCT
Notice Eff D/T: 09/01/2026 11:53 AM MCT
Notice End D/T: 
Reqrd Rsp Desc: No response required
Rsp D/T: 

Notice ID: 26-170
Prior Notice: 26-167
Subject: Sumas Meter Upgrade Part 1 - Deficiency Period Ending

Notice Text:

Northwest will complete the Sumas Meter Upgrade Part 1 on 
schedule as referenced in Notice ID 26-156. This will end the  
current Deficiency Period referenced in Notice ID 26-167 at the 
completion of Gas Day September 01, 2026.
As a reminder, the Sumas Meter Upgrade Part 2 referenced in All 
Shipper Notice #26-162 will further limit the available 
capacity at the Sumas CS to 821,000 Dth/d southbound beginning 
Gas Day September 02, 2026, through Gas Day September 09, 2026.
If you have any questions, please contact your Commercial 
Services Representative or the hotline at 713-215-6301.
Texas Eastern Transmission (TETCO)

09/01/2026- Pollard to Oran Line 1 Valve Section 3 Isolation -- COMPLETE

SEV 1/5
Informational

Pre-screen severity 1 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name: Texas Eastern Transmission, LP
Subject: Pollard to Oran Line 1 Valve Section 3 Isolation -- COMPLETE
Notice Type: Capacity Constraint
Critical Notice Description: Critical notice
Notice Status Description: Initiate
Notice Effective Date: 09/01/2026
Notice End Date: 11/30/2026
Posting Date: 09/01/2026
Notice Identifier: 182422
Required Response Indicator Description: No response required

Notice Text:
Texas Eastern has completed the previously posted Pollard to Oran Line 1 VS 3 isolation (August 25 - September 3) and the line has been returned to normal operations.
Effective immediately, all restrictions associated with this outage have been lifted.
Please contact your Operations Account Representative if you have any questions.
Northern Border Pipeline (NBPL)

Construction and Maintenance Schedule - Updated September 1, 2026

SEV 1/5
Informational

Pre-screen severity 1 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name Northern Border Pipeline Company
TSP 021632583
Notice Type Description: Maintenance

Notice Stat Desc: Initiate

Prior Notice: 

Critical: Y

Reqrd Rsp Desc: No Response Required
Post

Notice Effective

Notice End



Response
Post Date: 09/01/26

09/01/26

03/31/27
Subject: Subject: Construction and Maintenance Schedule - Updated September 1, 2026
Author: Author: Mark Begley
Notice Text
As a courtesy, Northern Border Pipeline (NBPL) hereby notifies customers of the Construction and Maintenance Schedule posted under "Construction and Maintenance" on the Informational Postings website. NBPL reminds customers to please check the Maintenance Schedule on a regular basis.

Changes since last posting:

·       Add – Estelline Station 11 Lube Oil Line Check Valve Replacement on 9/2

·       Date Change – Garvin Station 12 Lube Oil Valve Work from 9/18 to 9/3

·       Description Change – Saint Anthony Station 7 Filters Replacement on 9/10

·       Remove – Garvin Station 12 Fall Outage on 9/24 





Additionally, the following file(s) can be located on Informational Postings under Construction and Maintenance

2026 NBPL maintenance schedule 090126.pdf
Millennium Pipeline (MPC)

LIFTED: Line A5 at Bennetts Creek Maintenance September 1, 2026

SEV 1/5
Informational

Pre-screen severity 1 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name Millennium Pipeline Company, L.L.C.
TSP 607821050
Notice Type Description: Maintenance

Notice Stat Desc: Supersede

Prior Notice: 26202010

Critical: Y

Reqrd Rsp Desc: No Response Required
Post

Notice Effective

Notice End



Response
Post Date: 09/01/26

09/01/26

10/01/26
Subject: Subject: LIFTED: Line A5 at Bennetts Creek Maintenance September 1, 2026
Author: Author: Ulises Osorio
Notice Text
Millennium Pipeline Company (MPC) notifies customers that the Line A5 at (Bennetts Creek) Maintenance has been completed as of Tuesday, September 1, 2026.

As a result, effective Intraday 1 Cycle (ID1) Gas Day Tuesday, September 1st Independence (Loc prop 634444) will be reinstated back to Total Capacity.

***Previous Posting***

Millennium Pipeline Company (MPC) would like to notify customers that the pipeline maintenance at Line A5 at Bennetts Creek has been extended. 

* Revised end date: August 18th – September 2nd, 2026 (Previously scheduled to end on August 31st, 2026)

MPC will continue to provide updates as necessary and appreciates customers' cooperation during this maintenance activity.

If you have questions, please contact Customer Services at 866-581-6487.

***Previous Posting***

Millennium Pipeline Company (MPC) would like to remind customers of the upcoming pipeline maintenance at Line A5 at Bennetts Creek beginning with the Timely cycle for Gas Day Tuesday, August 18, 2026.  

Segment(s) Restriction(s) 

 There are no segment restrictions necessary for this outage

Point(s) Restriction(s)

The following location(s) will be reduced to 0 Total capacity (Receipts and Deliveries) for the duration of the maintenance: 

Independence (Loc prop 634444) 

AutoPAL Availability

At this time, AutoPAL remains available.

As a reminder to customers, the intent of the AutoPAL service is to utilize nominal quantities to resolve minor pool imbalances that result from small upstream or downstream reductions during the Gas Day. These quantities are then paid back the next cycle of the Gas Day.

MPC will monitor AutoPAL activity and reserves the right to make AutoPAL unavailable.

RCC’s

Reservation Charge Credits will be determined per the process set forth in Section 15 of MPC’s FERC Gas tariff.

Questions

If you have questions, please contact Customer Services at 866-581-6487.

Please continue to monitor our Critical Notices for updates on progress as well.
Columbia Gulf Transmission (CGT)

CAPACITY POSTING - TIM for September 2, 2026

UNSCORED
Informational
View original notice text
TSP Name Columbia Gulf Transmission, LLC
TSP 007854581
Notice Type Description: Capacity Constraint

Notice Stat Desc: Initiate

Prior Notice: 

Critical: Y

Reqrd Rsp Desc: No Response Required
Post

Notice Effective

Notice End



Response
Post Date: 09/01/26

09/01/26

10/01/26
Subject: Subject: CAPACITY POSTING - TIM for September 2, 2026
Author: Author: Zachery Heaver
Notice Text
COLUMBIA GULF TRANSMISSION, LLC DAILY CAPACITY POSTING 

Columbia Gulf Transmission LLC (CGT) posts projections of anticipated restrictions at least 24 hours prior to the time when nominations are due. These advance forecasts are subject to change based on actual operating conditions. Customers should submit nominations for Timely Cycle to determine whether the service is available under current conditions. 

============================================================================

============================================================================

FORCE MAJEURE / OFO 

No Force majeure is necessary. 

No Operational Flow Order (OFO) is necessary.

============================================================================

============================================================================

Customers are encouraged to monitor scheduled volumes on the Operationally Available Capacity (OAC) screen on Navigates Informational Postings, as nominations may fluctuate based on market conditions.

============================================================================

============================================================================

----------------------------------------------------------------------------

INTERNAL CONSTRAINTS-- Total Capacity (Net Backhaul):

----------------------------------------------------------------------------

StanSEG – 1,950,000 

ClemSEG – Total Capacity  

HartSEG – Total Capacity

HampSEG – Total Capacity

CorinSEG – Total Capacity 

BannSEG – 2,300,000

InvrnSEG – Total Capacity 

ShelSEG – Total Capacity

DelhiSEG – Total Capacity

AlexSEG – Total Capacity  

RayneSEG – Total Capacity

WLSEG – Total Capacity

ELSEG – Total Capacity 

EL300SEG – Total Capacity 

HoumaSEG – Total Capacity

----------------------------------------------------------------------------

INTERNAL CONSTRAINTS-- Total Capacity (Net Forwardhaul):

----------------------------------------------------------------------------

StanSEG – Total Capacity 

ClemSEG – Total Capacity

HartSEG – Total Capacity

HampSEG – Total Capacity

CorinSEG – Total Capacity

BannSEG – Total Capacity

InvrnSEG – Total Capacity

ShelSEG – Total Capacity

DelhiSEG - Total Capacity

AlexSEG – Total Capacity

RayneSEG – Total Capacity

WLSEG – Total Capacity

ELSEG – Total Capacity 

EL300SEG – Total Capacity  

HoumaSEG – Total Capacity

               

----------------------------------------------------------------------------

POINT CONSTRAINTS -- Total Capacity:

----------------------------------------------------------------------------

Note: Points listed are controlled by less than meter capacity.

401 - CROSSTEX-GIBSON - 0

445 - TRANSCO / TERREBONNE - 0

481 - SEA ROBIN-ERATH - 0

3194 - TETCO ADAIR CO., KY (Receipts) - Total Capacity (Primary Only)

4051 - LAFAYETTE - ACADIA - Total Capacity (Primary Only)

4078 - SONAT-SHADYSIDE - Total Capacity (Primary Only) 

4098 - BURLINGTON - TERREBONNE - 0

4118 - FLORIDA GAS - Total Capacity (Primary Only)

4123 - EGAN STOR-ACADIA-REC (Receipts and Deliveries) - 370,000 

4137 - CLECO-TECHE - Total Capacity (Primary Only)

4186 - DISCOVERY GAS TRANSMISSION (Deliveries) - Total Capacity (Primary Only)

4197 - MidWestern Pipeline (Deliveries) - 50,000

4204D - GULF SOUTH DELHI Delivery - Total Capacity (Primary Only)

4208R - SOUTHEASTERN SUPPLY HEADER (SESH) - Receipt - 0

4221 - GULF CROSSING - Total Capacity (Primary Only)

4222 - Texas Gas (Isola) - 0

4315 - BROADMORE RD (Receipts) - 775,000 

5112 - NORAM PERRYVILLE Delivery - Total Capacity (Primary Only) 

----------------------------------------------------------------------------

DUE PIPE AND DUE SHIPPER AVAILABILITY:

----------------------------------------------------------------------------

Due Pipe - Available 

Due Shipper - Not Available

============================================================================

============================================================================

PAL & IT BUSINESS

Representatives are available on a daily basis to discuss PAL transactions with customers who have executed master PAL service agreements. (Reminder: Each PAL transaction including rate, term, quantity and point(s) must be provided for and approved on the Appendix A under the Master PAL Agreement). Customers who are interested in PAL transactions for next-day or longer-term park and/or lend transactions or daily discounted IT paths should contact Diana Roberts at 832-758-0900 (ICE droberts6) or Adam Herndon at 832-689-4510 (ICE adherndon) for more information.  

----------------------------------------------------------------------------

AUTO PAL AVAILABILITY:

----------------------------------------------------------------------------

Effective with EVENING Cycle for each Gas Day, Auto Parks/Loans will be limited to +/- 5,000 Dth. Customers are reminded the intent of AutoPAL service is to utilize nominal quantities to resolve pool imbalances that result from upstream or downstream reductions during the cycle. This service should not be used for parking or loaning large quantities.

AutoPAL Parks and Loan Payback - Available

AutoPAL Loans and Unparks - Available

* Denotes a change from previous posting.
Columbia Gas Transmission (TCO)

CAPACITY POSTING - TIM for September 2, 2026

SEV 1/5
Informational

Pre-screen severity 1 -- below full-score threshold.

Below alert threshold -- no detailed analysis performed.
Reroute: Not assessed.
View original notice text
TSP Name Columbia Gas Transmission, LLC
TSP 054748041
Notice Type Description: Capacity Constraint

Notice Stat Desc: Initiate

Prior Notice: 

Critical: Y

Reqrd Rsp Desc: No Response Required
Post

Notice Effective

Notice End



Response
Post Date: 09/01/26

09/01/26

10/01/26
Subject: Subject: CAPACITY POSTING - TIM for September 2, 2026
Author: Author: Dillon Schoolcraft
Notice Text
COLUMBIA GAS TRANSMISSION, LLC DAILY CAPACITY POSTING

Columbia Gas Transmission LLC (TCO) posts projections of anticipated market area restrictions at least 24 hours prior to the time when nominations are due. These advance forecasts are subject to change based on actual operating conditions. Customers desiring non-firm services should submit timely nominations to determine whether the service is available under current conditions.

============================================================================

============================================================================

FORCE MAJEURE / STORAGE CRITICAL / TRANSPORT CRITICAL / OFO / RATABLE TAKES

No Force Majeure is necessary.

No Critical Day for Storage is necessary. 

No Critical Day for Transport is necessary.

No Operational Flow Order (OFO) is necessary.

Ratable Takes are not required in any Market Areas; however, power customers should request non-ratable takes by submitting a burn profile through TCeConnects.

============================================================================

============================================================================

PIPELINE RECEIPTS, DELIVERIES, INTERNAL CONSTRAINTS, AND DISPLACEMENT AVAILABILITY

For receipts, deliveries, and internal constraints not specifically listed below, please refer to ebb.tceconnects.com/Info Post/Capacity/Operationally Available for information on available capacity at each receipt and delivery point and ebb.tceconnects.com/Info Post/Capacity/Est Op Avail Cap - Internal Constraint for available non-firm capacity at each internal constraint.

Columbia may, from time to time, have displacement capacity available at various receipt/delivery points. Displacement nominations are scheduled based on operational availability up to an approved amount not to exceed the scheduled volumes in the physical direction of flow of the meter. Please contact your Customer Services, Marketing, or O&L Representative for availability at points not listed on this notice.

============================================================================

============================================================================

----------------------------------------------------------------------------

POINT CONSTRAINTS-- Non-Firm Available Capacity:

---------------------------------------------------------------------------- 

633863 - NFG Hartzfelt Mountain - 11,000

640203 - Wagoner Line K - 25,000

640296 - CLINGERMAN - 0

640297 - Range - Sharp - 0

640496 - Range - Day - 0 

640564 - Amwell - 0

642452 - CMG Majorsville - 0

642569 - Mojo - 0

642831 - Range Mills - 0

642838 - Strabane - 0

642854 - Kryptonite - 0

740178 - Fairfield - REX - 75,000

743064 - NEXUS MR06 - 75,000

743365 - Quarry Road - 25,000

736626 - DPL CENTERVILLE - 10,000

737067 - Darby Plant - 75,000

821590 - THOMAS COFFMAN INC YOUNG - 0 

821917 - A&W-Gandee - 0 

823621 - MOUNTAIN STATE-GRANT - 0

824017- STERLING DRG FETTTY - 0 

824766 - TECHNOLOGY DEVELOPMENT - FIELDS - 0 

825005 - CENTRAL PACIFIC GROUP SNYDER - 0 

826130 - STERLING DRG HARPER - 0 

828516 - DORAN-RAINES #1 - 0

833097 - BOSWELLS TAVERN (75-007219) - 0 (Receipts)

833097 - BOSWELLS TAVERN (75-007219) - 100,000

834263 - MCKOWN-JB YOAK LEASE - 0 

835078 - RYAN #702 - 0 

839166 - Patton - 0 

840226 - BenGay MM - 0 

840254 - Vandalia - 0 Total Capacity

842446 - Spencer H Line Sales - 0 

842866 - Green Energy Stonewall - 0

843105 - Transco Chantilly - 50,000

B10 - CAMBRIDGE-9 - 20,000

B15 - UNIONVILLE-35 - 10,000

B17 - HIGHLAND-36 - 20,000

B18 - MILFORD-21 - 0

B9 - BROAD RUN-19 - 0 (Receipts)

B9 - BROAD RUN-19 - 0 (Deliveries)

BYBEE - BYBEE - 0 (Deliveries)

C10 - PLEASANT - 0

C14 - WAYNESBURG - 20,000 

C15 - UNIONTOWN-35 - 0

C16 - DELMONT-36 - 0 (Receipts)

C16 - DELMONT-36 - 0 (Deliveries)

C22 - EAGLE-25 - 0

C23 - PENNSBURG-23 - 0

C41 - TEXAS EASTERN TETCON - 0

C45 - Marietta - 0

C9 - HOOKER-5 - 50,000

E13 - EMPORIA, VA-34 - 0

E17 - MARTINS CREEK - 21 - 0 (Receipts)

E17 - MARTINS CREEK - 21 - 15,000 (Deliveries)

E2 - ROCKVILLE-30 - 0

E3 - DOWNINGTOWN-29 - 0

E9 - YNG WOMANS CK-RENOVO - 0

G8 - EAST LYNN-16 - 0 

MVPWB - MVP Columbia WB - 0 (Receipts)

MVPWB - MVP Columbia WB - 0 (Deliveries)

----------------------------------------------------------------------------

DELIVERY INTERNAL CONSTRAINTS-- Non-Firm Available Capacity:

----------------------------------------------------------------------------

ARTEMAS - Artemas MA25 - 0

BICKBOSW - Bickers MA33 - No Restriction 

CERELANH - Lanham East MA19 - 0 

CERELANW - Lanham West MA19 - 0

CORNHART - Corning East MA20 - 0

CRAWNORT - Crawford North MA8 - 0

CSLOSTRI - Lost River CS MA30 - No Restriction

DELMONSO - Delmont South MA36 - 10,000

DOWNEAST - Downingtown East MA24 - 25,000

GRENCSTL - Greencastle MA25 - No Restriction

HELLHANO - Hellertown MA22 - 0

HIGHLAND - Highland MA38 - 10,000

HOPEWELL - Hopewell MA33 - No Restriction

INDEGLAS - Corning West MA20 - 5,548

KAEAST - KA East MA17 - 0

LANPKA - Lanham PKA MA19 - 0

LEACHSEG - Leach MA19 - No Restriction

LOUDOUN - Loudoun MA28 - No Restriction

LOUISA - Louisa MA33 - No Restriction 

MA1SEG - Pavonia to Toledo - 10,000 

MA3SEG - Lima MA3 - 10,000 

MA6SEG - Dayton MA6 – 20,000

MA7SEG - Sandusky MA7 - 60,000 

NORTKENT - Northern Kentucky OA6 - No Restriction

PTJRWARW - Wagoner East MA21 - No Restriction

RUTLEDGE - Rutledge North MA28 - 50,000

SENECA - Seneca MA30 - No Restriction

----------------------------------------------------------------------------

RECEIPT INTERNAL CONSTRAINTS-- Non-Firm Available Capacity:

----------------------------------------------------------------------------

A03LINEH - Cobb Line H MA18 - No Restriction

A03LOW - Cobb Northwest MA18 - No Restriction

A03NORTH - Cobb Northeast MA40 - No Restriction

A03SOUTH - Cobb South MA18 - No Restriction

ADALSMIF - Smithfield to Adaline MA35 - 0

ALLIAREC - Alliance Receipts MA4 - 20,000

BOLDMAN - Boldman MA16 - 0

CHSTKENO - Line P North MA16 - 25,000 

CLENWAYN - Clendenin to Waynesburg MA35 - 0

COBBA03 - Cobb CS MA18 - No Restriction

CRAWSOUT - Crawford South MA8 - No Restriction

DELMRENO - Delmont MA36 - No Restriction

DOWNWEST - Downingtown West MA24 - 0

EASTON - Easton MA21 - 0

GRANHAML - KA High MA19 - 25,000

HANCOCK - Hancock MA20 - 0

KA1SCBYB - KA1 Station Camp MA13 - 5,500

KAWEST - KA West MA17 - 0

LEBANON - Lebanon MA6 - 50,000 

LONEOAKA - Lone Oak A MA41 - 0

LONEOAKB - Lone Oak B MA41 - 0 

LXPSEG - LXPSEG MA41 - 0

MAYTHUFF - KA Low MA16 - 0 

MXPSEG - MXPSEG MA42 - 0

RUTSOUTH - Rutledge South MA28 - 0 

SHERWODA - Sherwood A MA42 - 0

SHERWODB - Sherwood B MA42 - 100,000 

SMITHFLD - Smithfield MA35 - 0

TANNDELM - Line 1711 MA35 - 0

WALGROVE - Walgrove MA18 - No Restriction

WAYNESNO - Waynesburg North MA35 - 0

 

----------------------------------------------------------------------------

DISPLACEMENT AVAILABILITY-- Non-Firm Available Capacity:

----------------------------------------------------------------------------

843067 - Cornwell - 100,000 

C14 - WAYNESBURG - 30,000

C22 - EAGLE-25 - 25,000

C23 - PENNSBURG-23 - 0

C4 - TETCO LEBANON-6 - 0

E2 - ROCKVILLE-30 - 0

LOUDOUN - LOUDOUN LNG - 0

----------------------------------------------------------------------------

TRANSFER METERS-- Non-Firm Available Capacity:

----------------------------------------------------------------------------

TMBOSWLL - TM Boswells Tavern MA33 - 500,000

TMBRDRUN - TM Broad Run MA19 - 500,000

TMCEREDO - TM Ceredo MA19 - 500,000

TMCHANTY - TM Chantilly MA30 - 500,000

TMEAGLE - TM Eagle MA25 - 500,000

TMLEACH - TM Leach MA19 - 500,000

TMLOSTRI - TM Lost River MA30 - 500,000

TMLOUDN - TM Loudoun MA30 - 500,000

TMLXP - TM LXP MA41 - 500,000

TMMXP - TM MXP MA42 - 500,000

----------------------------------------------------------------------------

LOGICAL METERS-- Non-Firm Available Capacity:

----------------------------------------------------------------------------

MLAPLGRV – Mainline Apple Grove - 500,000

MLCRWFRD - Mainline Crawford - 500,000

MLDRYCRE - Mainline Dry Creek - 500,000

MLEAGLE - Mainline Eagle - 500,000

MLLEACH - Mainline Leach - 500,000

MLLOUDOU - Mainline Loudoun - 500,000

MLLXPMAJ - Mainline LXP Majorsville - 500,000

MLNEWALB - Mainline New Albany - 500,000 

MLPETERS - Mainline Petersburg - 500,000

MLSDRCRK - Mainline Saunders Creek - 500,000

----------------------------------------------------------------------------

DUE PIPE AND DUE SHIPPER AVAILABILITY:

----------------------------------------------------------------------------

OP AREA 01 - Due Pipe - 0, Due Shipper - No Restriction

OP AREA 02 - Due Pipe - 0, Due Shipper - No Restriction

OP AREA 03 - Due Pipe - 0, Due Shipper - No Restriction

OP AREA 04 - Due Pipe - 0, Due Shipper - No Restriction 

OP AREA 05 - Due Pipe - 0, Due Shipper - No Restriction

OP AREA 06 - Due Pipe - 0, Due Shipper - No Restriction

OP AREA 07 - Due Pipe - 0, Due Shipper - No Restriction

OP AREA 08 - Due Pipe - 0, Due Shipper - No Restriction 

OP AREA 10 - Due Pipe - 0, Due Shipper - No Restriction

============================================================================

============================================================================

PAL & IT BUSINESS

Representatives are available daily to discuss PAL transactions with customers who have executed Master PAL Agreements. (Reminder: Each PAL transaction including rate, term, quantity and point(s) must be provided for and approved on the Appendix A under the Master PAL Agreement).Customers who are interested in discounted PAL transactions for next-day or long-term park and/or lend transactions or daily discounted IT paths should contact Diana Roberts at 832-320-5454 (ICE droberts6) or Adam Herndon at 832-689-4510 (ICE adherndon) for more information.

AUTO PAL AVAILABILITY

Effective with EVENING Cycle for each Gas Day, Auto Parks/Loans will be limited to +/-5,000 Dth.Customers are reminded the intent of AutoPAL service is to utilize nominal quantities to resolve pool imbalances that result from upstream or downstream reductions during the cycle.This service should not be used for parking or loaning large quantities.

The following services are eligible for Auto Park/Loan Paybacks and Auto Loan/Park Withdrawals:

IPP

SPP

A01 - Kenova

A02 - Flat Top

A03 - Cobb

A04 - Alexander 

A05 - Delmont 

A06 - McClellandtown

A08 - Crawford

A09 - York 

A10 - Dungannon 

A11 - Binghamton

A12 - Mountaineer Xpress

* Denotes a change from previous posting
September 2026
248 notices
August 2026
2480 notices
July 2026
719 notices
June 2026
757 notices
May 2026
683 notices
April 2026
1007 notices
March 2026
896 notices